Sumit Arun Raurale
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sumit Arun Raurale has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Gordon Lightbody
INFANT Research Centre, University College Cork, Cork, Ireland
6 shared publicationsGeraldine B. Boylan
INFANT Research Centre, University College Cork, Cork, Ireland
5 shared publicationsJohn M. O'Toole
INFANT Research Centre, Ireland
5 shared publications- Jesus Martinez del Rincon
Centre for Secure Information Technologies (CSIT), Queen’s University Belfast, Belfast, United Kingdom of Great Britain and Northern Ireland
4 shared publications John McAllister
Centre for Data Science and Scalable Computing (DSSC), Institute of Electronics, Communications and Information Technology (ECIT), Queen’s University Belfast, Belfast, U.K.
3 shared publications- John McAllister
Queen's University Belfast, Belfast, United Kingdom
3 shared publications
Latest Publications
- Open Access
- 10 March 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-8
Neonatal EEG graded for severity of background abnormalities in hypoxic-ischaemic encephalopathy
This report describes a set of neonatal electroencephalogram (EEG) recordings graded according to the severity of abnormalities in the background pattern. The dataset consists of 169 hours of multichannel EEG from 53 neonates recorded in a neonatal intensive care unit. All neonates received a diagnosis of hypoxic-ischaemic encephalopathy (HIE), the most common cause of brain injury in full term infants. For each neonate, multiple 1-hour epochs of good quality EEG were selected and then graded for background abnormalities. The grading system assesses EEG attributes such as amplitude, continuity, sleep–wake cycling, symmetry and synchrony, and abnormal waveforms. Background severity was then categorised into 4 grades: normal or mildly abnormal EEG, moderately abnormal EEG, majorly abnormal EEG, and inactive EEG. The data can be used as a reference set of multi-channel EEG for neonates with HIE, for EEG training purposes, or for developing and evaluating automated grading algorithms.
- 10 March 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-8
Open AccessNeonatal EEG graded for severity of background abnormalities in hypoxic-ischaemic encephalopathy
This report describes a set of neonatal electroencephalogram (EEG) recordings graded according to the severity of abnormalities in the background pattern. The dataset consists of 169 hours of multichannel EEG from 53 neonates recorded in a neonatal intensive care unit. All neonates received a diagnosis of hypoxic-ischaemic encephalopathy (HIE), the most common cause of brain injury in full term infants. For each neonate, multiple 1-hour epochs of good quality EEG were selected and then graded for background abnormalities. The grading system assesses EEG attributes such as amplitude, continuity, sleep–wake cycling, symmetry and synchrony, and abnormal waveforms. Background severity was then categorised into 4 grades: normal or mildly abnormal EEG, moderately abnormal EEG, majorly abnormal EEG, and inactive EEG. The data can be used as a reference set of multi-channel EEG for neonates with HIE, for EEG training purposes, or for developing and evaluating automated grading algorithms.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 70 (1) , 17-26
Wearable Antennas for Human Identification at 2.45 GHz
In this article, antenna sensitivity to the human body was investigated for the purpose of user identification. Through numerical and experimental analysis, the variation of the antenna return loss was measured while interacting with multiple human bodies at 2.45 GHz. A new antenna is proposed, which distributes the field within the tissue, enhancing the identification accuracy of the machine learning algorithm. Experiments conducted on six human subjects gave the classification accuracy of approximately 98%. To overcome the reduction in radiation efficiency, a layered stacked-patch design is introduced, which increases the radiation efficiency to 27% for the close-fitting wearable antenna.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 70 (1) , 17-26
Wearable Antennas for Human Identification at 2.45 GHz
In this article, antenna sensitivity to the human body was investigated for the purpose of user identification. Through numerical and experimental analysis, the variation of the antenna return loss was measured while interacting with multiple human bodies at 2.45 GHz. A new antenna is proposed, which distributes the field within the tissue, enhancing the identification accuracy of the machine learning algorithm. Experiments conducted on six human subjects gave the classification accuracy of approximately 98%. To overcome the reduction in radiation efficiency, a layered stacked-patch design is introduced, which increases the radiation efficiency to 27% for the close-fitting wearable antenna.
- Open Access
- 19 March 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 046007
Grading hypoxic-ischemic encephalopathy in neonatal EEG with convolutional neural networks and quadratic time–frequency distributions
Objective. To develop an automated system to classify the severity of hypoxic-ischaemic encephalopathy injury (HIE) in neonates from the background electroencephalogram (EEG). Approach. By combining a quadratic time–frequency distribution (TFD) with a convolutional neural network, we develop a system that classifies 4 EEG grades of HIE. The network learns directly from the two-dimensional TFD through 3 independent layers with convolution in the time, frequency, and time–frequency directions. Computationally efficient algorithms make it feasible to transform each 5 min epoch to the time–frequency domain by controlling for oversampling to reduce both computation and computer memory. The system is developed on EEG recordings from 54 neonates. Then the system is validated on a large unseen dataset of 338 h of EEG recordings from 91 neonates obtained across multiple international centres. Main results. The proposed EEG HIE-grading system achieves a leave-one-subject-out testing accuracy of 88.9% and kappa of 0.84 on the development dataset. Accuracy for the large unseen test dataset is 69.5% (95% confidence interval, CI: 65.3%–73.6%) and kappa of 0.54, which is a significant ( P < 0.001 ) improvement over a state-of-the-art feature-based method with an accuracy of 56.8% (95% CI: 51.4%–61.7%) and kappa of 0.39. Performance of the proposed system was unaffected when the number of channels in testing was reduced from 8 to 2—accuracy for the large validation dataset remained at 69.5% (95% CI: 65.5%–74.0%). Significance. The proposed system outperforms the state-of-the-art machine learning algorithms for EEG grade classification on a large multi-centre unseen dataset, indicating the potential to assist clinical decision making for neonates with HIE.
- 19 March 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 046007
Open AccessGrading hypoxic-ischemic encephalopathy in neonatal EEG with convolutional neural networks and quadratic time–frequency distributions
Objective. To develop an automated system to classify the severity of hypoxic-ischaemic encephalopathy injury (HIE) in neonates from the background electroencephalogram (EEG). Approach. By combining a quadratic time–frequency distribution (TFD) with a convolutional neural network, we develop a system that classifies 4 EEG grades of HIE. The network learns directly from the two-dimensional TFD through 3 independent layers with convolution in the time, frequency, and time–frequency directions. Computationally efficient algorithms make it feasible to transform each 5 min epoch to the time–frequency domain by controlling for oversampling to reduce both computation and computer memory. The system is developed on EEG recordings from 54 neonates. Then the system is validated on a large unseen dataset of 338 h of EEG recordings from 91 neonates obtained across multiple international centres. Main results. The proposed EEG HIE-grading system achieves a leave-one-subject-out testing accuracy of 88.9% and kappa of 0.84 on the development dataset. Accuracy for the large unseen test dataset is 69.5% (95% confidence interval, CI: 65.3%–73.6%) and kappa of 0.54, which is a significant ( P < 0.001 ) improvement over a state-of-the-art feature-based method with an accuracy of 56.8% (95% CI: 51.4%–61.7%) and kappa of 0.39. Performance of the proposed system was unaffected when the number of channels in testing was reduced from 8 to 2—accuracy for the large validation dataset remained at 69.5% (95% CI: 65.5%–74.0%). Significance. The proposed system outperforms the state-of-the-art machine learning algorithms for EEG grade classification on a large multi-centre unseen dataset, indicating the potential to assist clinical decision making for neonates with HIE.
- Open Access
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 12256-12266
EMG Biometric Systems Based on Different Wrist-Hand Movements
Electromyogram (EMG) acquisition and analysis is growing in importance with human attempts to interact with and control equipment such as robots, prostheses or virtual environments. In some cases, only approved users should be permitted these capabilities. For these applications, securing EMG-based control is a major open question - to the best of the authors’ knowledge, no prior art exists which can identify individuals from a wide range of wrist-hand gestures EMG readings within the wearable device. This paper addresses this problem. Techniques are presented which allow EMG to be used as a biometric, allowing users to verify themselves. An EMG-sensing armband attached to the lower forearm is used to anonymously authenticate users as a member of an approved group, or to identify themselves uniquely. For the development of extensive biometric system, three EMG datasets with similar EMG sensing in different sessions were exploited. For verification, accuracy of up to 93% is achieved, with 92% achieved for identification. The system is also shown to operate in real-time on an ARM Cortex A-53 embedded processor suitable for housing in an EMG wearable device, incurring latencies of 1.06 ms and 1.61 ms for verification and identification respectively. These metrics are comfortably sufficient for use in real-time, battery-powered EMG authentication devices.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 12256-12266
Open AccessEMG Biometric Systems Based on Different Wrist-Hand Movements
Electromyogram (EMG) acquisition and analysis is growing in importance with human attempts to interact with and control equipment such as robots, prostheses or virtual environments. In some cases, only approved users should be permitted these capabilities. For these applications, securing EMG-based control is a major open question - to the best of the authors’ knowledge, no prior art exists which can identify individuals from a wide range of wrist-hand gestures EMG readings within the wearable device. This paper addresses this problem. Techniques are presented which allow EMG to be used as a biometric, allowing users to verify themselves. An EMG-sensing armband attached to the lower forearm is used to anonymously authenticate users as a member of an approved group, or to identify themselves uniquely. For the development of extensive biometric system, three EMG datasets with similar EMG sensing in different sessions were exploited. For verification, accuracy of up to 93% is achieved, with 92% achieved for identification. The system is also shown to operate in real-time on an ARM Cortex A-53 embedded processor suitable for housing in an EMG wearable device, incurring latencies of 1.06 ms and 1.61 ms for verification and identification respectively. These metrics are comfortably sufficient for use in real-time, battery-powered EMG authentication devices.
- 28 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 6103-6106
Grading the severity of hypoxic-ischemic encephalopathy in newborn EEG using a convolutional neural network
Electroencephalography (EEG) is a valuable clinical tool for grading injury caused by lack of blood and oxygen to the brain during birth. This study presents a novel end-to-end architecture, using a deep convolutional neural network, that learns hierarchical representations within raw EEG data. The system classifies 4 grades of hypoxic-ischemic encephalopathy and is evaluated on a multi-channel EEG dataset of 63 hours from 54 newborns. The proposed method achieves a testing accuracy of 79.6% with one-step voting and 81.5% with two-step voting. These results show how a feature-free approach can be used to classify different grades of injury in newborn EEG with comparable accuracy to existing feature-based systems. Automated grading of newborn background EEG could help with the early identification of those infants in need of interventional therapies such as hypothermia.
- 28 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 6103-6106
Grading the severity of hypoxic-ischemic encephalopathy in newborn EEG using a convolutional neural network
Electroencephalography (EEG) is a valuable clinical tool for grading injury caused by lack of blood and oxygen to the brain during birth. This study presents a novel end-to-end architecture, using a deep convolutional neural network, that learns hierarchical representations within raw EEG data. The system classifies 4 grades of hypoxic-ischemic encephalopathy and is evaluated on a multi-channel EEG dataset of 63 hours from 54 newborns. The proposed method achieves a testing accuracy of 79.6% with one-step voting and 81.5% with two-step voting. These results show how a feature-free approach can be used to classify different grades of injury in newborn EEG with comparable accuracy to existing feature-based systems. Automated grading of newborn background EEG could help with the early identification of those infants in need of interventional therapies such as hypothermia.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2020, 5984-5987
Identifying tracé alternant activity in neonatal EEG using an inter-burst detection approach
Electroencephalography (EEG) is an important clinical tool for reviewing sleep wake cycling in neonates in intensive care. Tracé alternant (TA) - a characteristic pattern of EEG activity during quiet sleep in term neonates - is defined by alternating periods of short-duration, high-voltage activity (bursts) separated by lower-voltage activity (inter-bursts). This study presents a novel approach for detecting TA activity by first detecting the inter-bursts and then processing the temporal map of the bursts and inter-bursts. EEG recordings from 72 healthy term neonates were used to develop and evaluate performance of 1) an inter-burst detection method which is then used for 2) detection of TA activity. First, multiple amplitude and spectral features were combined using a support vector machine (SVM) to classify bursts from inter-bursts within TA activity, resulting in a median area under the operating characteristic curve (AUC) of 0.95 (95% confidence interval, CI: 0.93 to 0.98). Second, post-processing of the continuous SVM output, the confidence score, was used to produce a TA envelope. This envelope was used to detect TA activity within the continuous EEG with a median AUC of 0.84 (95% CI: 0.80 to 0.88). These results validate how an inter-burst detection approach combined with post processing can be used to classify TA activity. Detecting the presence or absence of TA will help quantify disruption of the clinically important sleep - wake cycle.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2020, 5984-5987
Identifying tracé alternant activity in neonatal EEG using an inter-burst detection approach
Electroencephalography (EEG) is an important clinical tool for reviewing sleep wake cycling in neonates in intensive care. Tracé alternant (TA) - a characteristic pattern of EEG activity during quiet sleep in term neonates - is defined by alternating periods of short-duration, high-voltage activity (bursts) separated by lower-voltage activity (inter-bursts). This study presents a novel approach for detecting TA activity by first detecting the inter-bursts and then processing the temporal map of the bursts and inter-bursts. EEG recordings from 72 healthy term neonates were used to develop and evaluate performance of 1) an inter-burst detection method which is then used for 2) detection of TA activity. First, multiple amplitude and spectral features were combined using a support vector machine (SVM) to classify bursts from inter-bursts within TA activity, resulting in a median area under the operating characteristic curve (AUC) of 0.95 (95% confidence interval, CI: 0.93 to 0.98). Second, post-processing of the continuous SVM output, the confidence score, was used to produce a TA envelope. This envelope was used to detect TA activity within the continuous EEG with a median AUC of 0.84 (95% CI: 0.80 to 0.88). These results validate how an inter-burst detection approach combined with post processing can be used to classify TA activity. Detecting the presence or absence of TA will help quantify disruption of the clinically important sleep - wake cycle.
- Open Access
Grading the severity of hypoxic-ischemic encephalopathy in newborn EEG using a convolutional neural network
Electroencephalography (EEG) is a valuable clinical tool for grading injury caused by lack of blood and oxygen to the brain during birth. This study presents a novel end-to-end architecture, using a deep convolutional neural network, that learns hierarchical representations within raw EEG data. The system classifies 4 grades of hypoxic-ischemic encephalopathy and is evaluated on a multi-channel EEG dataset of 63 hours from 54 newborns. The proposed method achieves a testing accuracy of 79.6% with one-step voting and 81.5% with two-step voting. These results show how a feature-free approach can be used to classify different grades of injury in newborn EEG with comparable accuracy to existing feature-based systems. Automated grading of newborn background EEG could help with the early identification of those infants in need of interventional therapies such as hypothermia.
Open AccessGrading the severity of hypoxic-ischemic encephalopathy in newborn EEG using a convolutional neural network
Electroencephalography (EEG) is a valuable clinical tool for grading injury caused by lack of blood and oxygen to the brain during birth. This study presents a novel end-to-end architecture, using a deep convolutional neural network, that learns hierarchical representations within raw EEG data. The system classifies 4 grades of hypoxic-ischemic encephalopathy and is evaluated on a multi-channel EEG dataset of 63 hours from 54 newborns. The proposed method achieves a testing accuracy of 79.6% with one-step voting and 81.5% with two-step voting. These results show how a feature-free approach can be used to classify different grades of injury in newborn EEG with comparable accuracy to existing feature-based systems. Automated grading of newborn background EEG could help with the early identification of those infants in need of interventional therapies such as hypothermia.
- Open Access
Identifying trace alternant activity in neonatal EEG using an inter-burst detection approach
Electroencephalography (EEG) is an important clinical tool for reviewing sleep-wake cycling in neonates in intensive care. Trace alternant (TA)-a characteristic pattern of EEG activity during quiet sleep in term neonates-is defined by alternating periods of short-duration, high-voltage activity (bursts) separated by lower-voltage activity (inter-bursts). This study presents a novel approach for detecting TA activity by first detecting the inter-bursts and then processing the temporal map of the bursts and inter-bursts. EEG recordings from 72 healthy term neonates were used to develop and evaluate performance of 1) an inter-burst detection method which is then used for 2) detection of TA activity. First, multiple amplitude and spectral features were combined using a support vector machine (SVM) to classify bursts from inter-bursts within TA activity, resulting in a median area under the operating characteristic curve (AUC) of 0.95 (95% confidence interval, CI: 0.93 to 0.98). Second, post-processing of the continuous SVM output, the confidence score, was used to produce a TA envelope. This envelope was used to detect TA activity within the continuous EEG with a median AUC of 0.84 (95% CI: 0.80 to 0.88). These results validate how an inter-burst detection approach combined with post processing can be used to classify TA activity. Detecting the presence or absence of TA will help quantify disruption of the clinically important sleep-wake cycle.
Open AccessIdentifying trace alternant activity in neonatal EEG using an inter-burst detection approach
Electroencephalography (EEG) is an important clinical tool for reviewing sleep-wake cycling in neonates in intensive care. Trace alternant (TA)-a characteristic pattern of EEG activity during quiet sleep in term neonates-is defined by alternating periods of short-duration, high-voltage activity (bursts) separated by lower-voltage activity (inter-bursts). This study presents a novel approach for detecting TA activity by first detecting the inter-bursts and then processing the temporal map of the bursts and inter-bursts. EEG recordings from 72 healthy term neonates were used to develop and evaluate performance of 1) an inter-burst detection method which is then used for 2) detection of TA activity. First, multiple amplitude and spectral features were combined using a support vector machine (SVM) to classify bursts from inter-bursts within TA activity, resulting in a median area under the operating characteristic curve (AUC) of 0.95 (95% confidence interval, CI: 0.93 to 0.98). Second, post-processing of the continuous SVM output, the confidence score, was used to produce a TA envelope. This envelope was used to detect TA activity within the continuous EEG with a median AUC of 0.84 (95% CI: 0.80 to 0.88). These results validate how an inter-burst detection approach combined with post processing can be used to classify TA activity. Detecting the presence or absence of TA will help quantify disruption of the clinically important sleep-wake cycle.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Signal Processing
- Vol. 68 (1053587X) , 2713-2723
Real-Time Embedded EMG Signal Analysis for Wrist-Hand Pose Identification
Electromyographic (EMG) signals sensed at the skin surface on the forearm can be used to accurately infer wrist- hand poses. However, this is only possible when the EMG sensors are carefully placed over specific arm muscles. This cannot be guaranteed for wearable devices, which could acquire EMG from anywhere on the forearm. As a result, these devices detect fewer poses, less accurately. In addition, the complexity of the time-frequency analysis used in placed-sensor systems precludes real-time detection using the simple embedded processors on EMG wearables. This paper describes an approach which resolves both these shortcomings. It shows that, when random sensor placement is adopted, wrist-hand movement detection with performance equal the state-of-the-art can be achieved, with only 10% of the computational complexity. This latter property allows the first real-time wrist-hand movement detector using only simple embedded processors; specifically when using on ARM Cortex- A53 processor, execution time is lowered by 90% against the state-of-the-art, with no reduction in detection performance. It is shown how this can be further reduced by 30% by using fewer EMG channels or features, whilst maintaining good detection performance. To the best of the authors' knowledge, this is the first record of real-time high-performance wrist-hand movement detection for standalone, battery-powered EMG wearables.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Signal Processing
- Vol. 68 (1053587X) , 2713-2723
Real-Time Embedded EMG Signal Analysis for Wrist-Hand Pose Identification
Electromyographic (EMG) signals sensed at the skin surface on the forearm can be used to accurately infer wrist- hand poses. However, this is only possible when the EMG sensors are carefully placed over specific arm muscles. This cannot be guaranteed for wearable devices, which could acquire EMG from anywhere on the forearm. As a result, these devices detect fewer poses, less accurately. In addition, the complexity of the time-frequency analysis used in placed-sensor systems precludes real-time detection using the simple embedded processors on EMG wearables. This paper describes an approach which resolves both these shortcomings. It shows that, when random sensor placement is adopted, wrist-hand movement detection with performance equal the state-of-the-art can be achieved, with only 10% of the computational complexity. This latter property allows the first real-time wrist-hand movement detector using only simple embedded processors; specifically when using on ARM Cortex- A53 processor, execution time is lowered by 90% against the state-of-the-art, with no reduction in detection performance. It is shown how this can be further reduced by 30% by using fewer EMG channels or features, whilst maintaining good detection performance. To the best of the authors' knowledge, this is the first record of real-time high-performance wrist-hand movement detection for standalone, battery-powered EMG wearables.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 4125-4128
Suitability of an inter-burst detection method for grading hypoxic-ischemic encephalopathy in newborn EEG
Electroencephalography (EEG) is an important clinical tool for grading injury caused by lack of oxygen or blood to the brain during birth. Characteristics of low-voltage waveforms, known as inter-bursts, are related to different grades of injury. This study assesses the suitability of an existing inter-burst detection method, developed from preterm infants born <30 weeks of gestational age, to detect inter-bursts in term infants. Different features from the temporal organisation of the inter-bursts are combined using a multi-layer perceptron (MLP) machine learning algorithm to classify four grades of injury in the EEG. We find that the best performing feature, percentage of inter-bursts, has an accuracy of 59.3%. Combining this with the maximum duration of inter-bursts in the MLP produces a testing accuracy of 77.8%, with similar performance to existing multi-feature methods. These results validate the use of the preterm detection method in term EEG and show how simple measures of the inter-burst interval can be used to classify different grades of injury.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 4125-4128
Suitability of an inter-burst detection method for grading hypoxic-ischemic encephalopathy in newborn EEG
Electroencephalography (EEG) is an important clinical tool for grading injury caused by lack of oxygen or blood to the brain during birth. Characteristics of low-voltage waveforms, known as inter-bursts, are related to different grades of injury. This study assesses the suitability of an existing inter-burst detection method, developed from preterm infants born <30 weeks of gestational age, to detect inter-bursts in term infants. Different features from the temporal organisation of the inter-bursts are combined using a multi-layer perceptron (MLP) machine learning algorithm to classify four grades of injury in the EEG. We find that the best performing feature, percentage of inter-bursts, has an accuracy of 59.3%. Combining this with the maximum duration of inter-bursts in the MLP produces a testing accuracy of 77.8%, with similar performance to existing multi-feature methods. These results validate the use of the preterm detection method in term EEG and show how simple measures of the inter-burst interval can be used to classify different grades of injury.