Ahmed F. Hegazy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ahmed F. Hegazy has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- A. Dave Nagpal
Schulich School of Medicine and Dentistry, Western University, Ontario, Canada; Division of Cardiac Surgery, Department of Surgery, Western University / London Health Sciences Center, London, Ontario; Critical Care Western, Western University / London Health Sciences Center, London, Ontario
2 shared publications Andrej Markota
Medical Intensive Care Unit, University Medical Center Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
2 shared publications- Daniel Bainbridge
Department of Anesthesiology and Perioperative Medicine, Department of Medicine, Division of Critical Care, Western University, London, Ontario, Canada
2 shared publications - Erik Kulstad
University of Texas Southwestern Medical Center
2 shared publications Fadi Elias
2 shared publicationsJohn Harlock
2 shared publications
Latest Publications
- 11 August 2025
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 69 (8) , e70104
High‐Flow Tracheal Oxygen for Weaning Mechanically Ventilated Tracheostomized Critically Ill Patients: A Retrospective Study
Background: Patients requiring invasive mechanical ventilation (MV) encounter significant morbidity and mortality in the ICU. High‐flow tracheal oxygen (HFTO) is used in tracheostomized patients to facilitate MV weaning. However, its impact on clinical outcomes is unclear. We aimed to assess the efficacy of early versus rescue HFTO in tracheostomized patients for successful MV weaning.Methods: This retrospective, cohort study, included MV tracheostomized patients between 2018 and 2024, who received HFTO for MV weaning. The early group received HFTO as the initial modality of MV weaning, while the rescue group received HFTO after failing initial attempts of conventional oxygen therapy delivered through a tracheal mask. The WIND (Weaning according to a New Definition) criteria was used to stratify patients into short, difficult, and prolonged weaning. The primary outcome was successful MV liberation at 60 days from the first successful separation attempt (tolerating ≥ 1 h off MV). Secondary outcomes included ventilator‐free days (VFDs) at 60 days and factors associated with successful MV weaning.Results: A total of 77 patients were included, with a median APACHE II of 17 (IQR 12–21). The most common reason for ICU admission was acute respiratory failure (n = 40, 51.9%). Median duration of invasive MV was 19 (IQR 13–28) days. Most patients were classified either as prolonged 51 (66.2%) or difficult weaning 18 (23.4%). Overall, 57 (74.0%) patients were successfully weaned from MV at 60 days. Two‐thirds of patients received rescue HFTO, while one‐third received early HFTO. Early and rescue HFTO showed no difference in successful MV weaning rates (76.9% vs. 72.5%, p = 0.679) or VFDs at 60 days (29.0, IQR 20.8–42.2 days vs. 27.4 IQR 14.3–50.8 days, p = 0.702). Male gender (OR 0.24, 95% CI 0.06–0.88) and hypertension (OR 0.24, 95% CI 0.07–0.82) were associated with lower odds of successful MV weaning.Conclusion: The timing of HFTO initiation (early vs. rescue) in tracheostomized patients may not have an impact on the rate of liberation from MV at 60 days. Future research should explore whether earlier implementation of HFTO enhances MV weaning.Editorial Comment: In this retrospective study, timing of high‐flow tracheal oxygen did not have an association with time of weaning from mechanical ventilation in tracheostomized adult patients in this cohort.
- 11 August 2025
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 69 (8) , e70104
High‐Flow Tracheal Oxygen for Weaning Mechanically Ventilated Tracheostomized Critically Ill Patients: A Retrospective Study
Background: Patients requiring invasive mechanical ventilation (MV) encounter significant morbidity and mortality in the ICU. High‐flow tracheal oxygen (HFTO) is used in tracheostomized patients to facilitate MV weaning. However, its impact on clinical outcomes is unclear. We aimed to assess the efficacy of early versus rescue HFTO in tracheostomized patients for successful MV weaning.Methods: This retrospective, cohort study, included MV tracheostomized patients between 2018 and 2024, who received HFTO for MV weaning. The early group received HFTO as the initial modality of MV weaning, while the rescue group received HFTO after failing initial attempts of conventional oxygen therapy delivered through a tracheal mask. The WIND (Weaning according to a New Definition) criteria was used to stratify patients into short, difficult, and prolonged weaning. The primary outcome was successful MV liberation at 60 days from the first successful separation attempt (tolerating ≥ 1 h off MV). Secondary outcomes included ventilator‐free days (VFDs) at 60 days and factors associated with successful MV weaning.Results: A total of 77 patients were included, with a median APACHE II of 17 (IQR 12–21). The most common reason for ICU admission was acute respiratory failure (n = 40, 51.9%). Median duration of invasive MV was 19 (IQR 13–28) days. Most patients were classified either as prolonged 51 (66.2%) or difficult weaning 18 (23.4%). Overall, 57 (74.0%) patients were successfully weaned from MV at 60 days. Two‐thirds of patients received rescue HFTO, while one‐third received early HFTO. Early and rescue HFTO showed no difference in successful MV weaning rates (76.9% vs. 72.5%, p = 0.679) or VFDs at 60 days (29.0, IQR 20.8–42.2 days vs. 27.4 IQR 14.3–50.8 days, p = 0.702). Male gender (OR 0.24, 95% CI 0.06–0.88) and hypertension (OR 0.24, 95% CI 0.07–0.82) were associated with lower odds of successful MV weaning.Conclusion: The timing of HFTO initiation (early vs. rescue) in tracheostomized patients may not have an impact on the rate of liberation from MV at 60 days. Future research should explore whether earlier implementation of HFTO enhances MV weaning.Editorial Comment: In this retrospective study, timing of high‐flow tracheal oxygen did not have an association with time of weaning from mechanical ventilation in tracheostomized adult patients in this cohort.
- Open Access
- 4 January 2024
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 39 (7) , 623-627
Postarrest Care Bundle Improves Quality of Care and Clinical Outcomes in the Normothermia Era
Purpose: Temperature targets in patients with cardiac arrest and return of spontaneous circulation (ROSC) have changed. Changes to higher temperature targets have been associated with higher breakthrough fevers and mortality. A post-ROSC normothermia bundle was developed to improve compliance with temperature targets. Methods: In August 2021, “ad hoc” normothermia at the discretion of the attending intensivist was initiated. In December 2021, a post-ROSC normothermia protocol was implemented, incorporating a rigorous, stepwise approach to fever prevention (temperature ≥ 37.8). We conducted a before-after cohort study of all adult patients post-ROSC who survived to intensive care unit admission between August 1, 2021, and April 1, 2022. They were divided into “ad hoc” and “protocol” groups. Clinical outcomes compared included fevers, active cooling, and paralytic use. Results: Fifty-eight post-ROSC patients were admitted; 24 in the “ad hoc” and 34 in the “protocol” groups. Patient demographics were similar between groups. The “ad hoc” group had more shockable rhythms (67% vs 24%, P = .001) and cardiac catheterizations (42% vs 15%, P = .03). The “protocol” group were significantly less likely to have a fever at 40 h (6% vs 40%, P < .001) and 72 h (14% vs 65%, P ≤ .001). Patients in the normothermia “protocol” used significantly less neuromuscular blocking agents (24% vs 50%, P = .05). The normothermia “protocol” resulted in similar mortality (56% vs 58%, P = 1.0). Conclusion: Use of a normothermia “protocol” resulted in fewer fevers and less neuromuscular blocker administration compared to “ad hoc” management. A protocolized approach for improved quality of care should be considered in institutions adopting normothermia.
- 4 January 2024
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 39 (7) , 623-627
Open AccessPostarrest Care Bundle Improves Quality of Care and Clinical Outcomes in the Normothermia Era
Purpose: Temperature targets in patients with cardiac arrest and return of spontaneous circulation (ROSC) have changed. Changes to higher temperature targets have been associated with higher breakthrough fevers and mortality. A post-ROSC normothermia bundle was developed to improve compliance with temperature targets. Methods: In August 2021, “ad hoc” normothermia at the discretion of the attending intensivist was initiated. In December 2021, a post-ROSC normothermia protocol was implemented, incorporating a rigorous, stepwise approach to fever prevention (temperature ≥ 37.8). We conducted a before-after cohort study of all adult patients post-ROSC who survived to intensive care unit admission between August 1, 2021, and April 1, 2022. They were divided into “ad hoc” and “protocol” groups. Clinical outcomes compared included fevers, active cooling, and paralytic use. Results: Fifty-eight post-ROSC patients were admitted; 24 in the “ad hoc” and 34 in the “protocol” groups. Patient demographics were similar between groups. The “ad hoc” group had more shockable rhythms (67% vs 24%, P = .001) and cardiac catheterizations (42% vs 15%, P = .03). The “protocol” group were significantly less likely to have a fever at 40 h (6% vs 40%, P < .001) and 72 h (14% vs 65%, P ≤ .001). Patients in the normothermia “protocol” used significantly less neuromuscular blocking agents (24% vs 50%, P = .05). The normothermia “protocol” resulted in similar mortality (56% vs 58%, P = 1.0). Conclusion: Use of a normothermia “protocol” resulted in fewer fevers and less neuromuscular blocker administration compared to “ad hoc” management. A protocolized approach for improved quality of care should be considered in institutions adopting normothermia.
- 12 September 2021
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 49 (5) , 389-394
Inferior vena cava assessment in term pregnant women using ultrasound: A comparison of the subcostal and right upper quadrant views
Point-of-care ultrasound can be used at the bedside to assess the haemodynamic status and fluid responsiveness of a pregnant woman. Previous studies demonstrated that views from the apical and parasternal windows are readily obtainable in labouring women. However, using the subcostal window to assess the inferior vena cava can be challenging because of the gravid uterus. A potential alternative is the right upper quadrant transhepatic window. We sought to compare visualisation of the inferior vena cava via the subcostal and right upper quadrant windows, in full-term pregnant women. This was a prospective pilot study carried out in a tertiary academic obstetric centre. Thirty pregnant non-labouring women at full term were recruited. In each patient, the inferior vena cava was visualised through both the subcostal and the right upper quadrant windows. Time to acquire each image, acquisition success rates and ease of obtaining images were compared for both approaches. Image quality was then reviewed and rated by two independent expert reviewers. There was a significant difference in the time required to obtain each view; subcostal median (interquartile range): 52 (35–59) seconds, right upper quadrant median (interquartile range): 23 (11–55) seconds (P=0.0045). Operator-defined successful image acquisition was 100% for the right upper quadrant window compared to 80% for the subcostal window. Ease of obtaining the view, as rated by the operator, was significantly easier in the right upper quadrant window compared to the subcostal window (P P=0.0213 and P=0.0005, respectively). Inter-rater agreement ranged between good (Cohen’s kappa coefficient 0.64) for right upper quadrant windows to fair (Cohen’s kappa coefficient 0.29) for subcostal windows. Inferior vena cava visualisation in term pregnant patients may take less time, be easier and provide better quality images when the right upper quadrant window is used compared to the subcostal window.
- 12 September 2021
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 49 (5) , 389-394
Inferior vena cava assessment in term pregnant women using ultrasound: A comparison of the subcostal and right upper quadrant views
Point-of-care ultrasound can be used at the bedside to assess the haemodynamic status and fluid responsiveness of a pregnant woman. Previous studies demonstrated that views from the apical and parasternal windows are readily obtainable in labouring women. However, using the subcostal window to assess the inferior vena cava can be challenging because of the gravid uterus. A potential alternative is the right upper quadrant transhepatic window. We sought to compare visualisation of the inferior vena cava via the subcostal and right upper quadrant windows, in full-term pregnant women. This was a prospective pilot study carried out in a tertiary academic obstetric centre. Thirty pregnant non-labouring women at full term were recruited. In each patient, the inferior vena cava was visualised through both the subcostal and the right upper quadrant windows. Time to acquire each image, acquisition success rates and ease of obtaining images were compared for both approaches. Image quality was then reviewed and rated by two independent expert reviewers. There was a significant difference in the time required to obtain each view; subcostal median (interquartile range): 52 (35–59) seconds, right upper quadrant median (interquartile range): 23 (11–55) seconds (P=0.0045). Operator-defined successful image acquisition was 100% for the right upper quadrant window compared to 80% for the subcostal window. Ease of obtaining the view, as rated by the operator, was significantly easier in the right upper quadrant window compared to the subcostal window (P P=0.0213 and P=0.0005, respectively). Inter-rater agreement ranged between good (Cohen’s kappa coefficient 0.64) for right upper quadrant windows to fair (Cohen’s kappa coefficient 0.29) for subcostal windows. Inferior vena cava visualisation in term pregnant patients may take less time, be easier and provide better quality images when the right upper quadrant window is used compared to the subcostal window.
- 1 February 2020
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 36 (2) , 313-316
Critical Care Management of the Acute Postimplant LVAD Patient
- 1 February 2020
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 36 (2) , 313-316
Critical Care Management of the Acute Postimplant LVAD Patient
- Open Access
- 4 April 2019
- Published by Springer Nature in BMC Health Services Research
- Vol. 19 (1) , 214
Identifying barriers to the use of ultrasound in the perioperative period: a survey of southwestern Ontario anesthesiologists
Ultrasound (US) can be used for many perioperative procedures, but evidence is lacking as to its frequency of use and barrier of application. The objectives of this survey were to determine i) how often US guidance was used perioperatively for vascular access placement, nerve blocks, and heart and lung assessment, and ii) to identify the barriers and the limitations of using US amongst anesthesiologists in southwestern Ontario. We conducted a web-based survey in over 40 academic or community hospitals at southwestern Ontario. Of 266 surveys sent, 66 complete surveys were obtained (response rate of 25%). Most respondents (> 80%) reported that US was commonly used for central venous catheter (CVC) insertion, followed by regional blocks; the uses were less frequent for neuraxial blockade and cardiopulmonary assessment. Most respondents wanted to use US more frequently as part of their practice and felt that they already had adequate US training. However, most respondents (59%) reported limited access to US machines in their working institutes as being the major barrier to incorporating US in their daily practice. The most common uses of US in anesthesia practice in southwestern Ontario were for CVC insertion and regional blocks. Most anesthesiologists in southwestern Ontario are interested to incorporate US in their daily practice but most were limited by the lack of US resources. Apparently, only providing knowledge and skills teaching may not be sufficient to further improve the US utilization in our region; a matched administrative effort appears to be the next challenge.
- 4 April 2019
- Published by Springer Nature in BMC Health Services Research
- Vol. 19 (1) , 214
Open AccessIdentifying barriers to the use of ultrasound in the perioperative period: a survey of southwestern Ontario anesthesiologists
Ultrasound (US) can be used for many perioperative procedures, but evidence is lacking as to its frequency of use and barrier of application. The objectives of this survey were to determine i) how often US guidance was used perioperatively for vascular access placement, nerve blocks, and heart and lung assessment, and ii) to identify the barriers and the limitations of using US amongst anesthesiologists in southwestern Ontario. We conducted a web-based survey in over 40 academic or community hospitals at southwestern Ontario. Of 266 surveys sent, 66 complete surveys were obtained (response rate of 25%). Most respondents (> 80%) reported that US was commonly used for central venous catheter (CVC) insertion, followed by regional blocks; the uses were less frequent for neuraxial blockade and cardiopulmonary assessment. Most respondents wanted to use US more frequently as part of their practice and felt that they already had adequate US training. However, most respondents (59%) reported limited access to US machines in their working institutes as being the major barrier to incorporating US in their daily practice. The most common uses of US in anesthesia practice in southwestern Ontario were for CVC insertion and regional blocks. Most anesthesiologists in southwestern Ontario are interested to incorporate US in their daily practice but most were limited by the lack of US resources. Apparently, only providing knowledge and skills teaching may not be sufficient to further improve the US utilization in our region; a matched administrative effort appears to be the next challenge.
- 5 January 2019
- Published by Springer Nature
- p. 457-469
Pulmonary Ultrasound
- Open Access
- 30 October 2018
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (3) , 346-347
Anaesthesia, Intensive Care and Perioperative Medicine A-Z: An Encyclopaedia of Principles and Practice, 6th Edition
- 30 October 2018
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (3) , 346-347
Open AccessAnaesthesia, Intensive Care and Perioperative Medicine A-Z: An Encyclopaedia of Principles and Practice, 6th Edition
- Open Access
- 1 March 2018
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 183 (suppl_1) , 162-168
Retrospective Analysis of Esophageal Heat Transfer for Active Temperature Management in Post-cardiac Arrest, Refractory Fever, and Burn Patients
Core temperature management is an important aspect of critical care; preventing unintentional hypothermia, reducing fever, and inducing therapeutic hypothermia when appropriate are each tied to positive health outcomes. The purpose of this study is to evaluate the performance of a new temperature management device that uses the esophageal environment to conduct heat transfer. De-identified patient data were aggregated from three clinical sites where an esophageal heat transfer device (EHTD) was used to provide temperature management. The device was evaluated against temperature management guidelines and best practice recommendations, including performance during induction, maintenance, and cessation of therapy. Across all active cooling protocols, the average time-to-target was 2.37 h and the average maintenance phase was 22.4 h. Patients spent 94.9% of the maintenance phase within ±1.0°C and 67.2% within ±0.5°C (574 and 407 measurements, respectively, out of 605 total). For warming protocols, all of the patient temperature readings remained above 36°C throughout the surgical procedure (average 4.66 h). The esophageal heat transfer device met performance expectations across a range of temperature management applications in intensive care and burn units. Patients met and maintained temperature goals without any reported adverse events.
- 1 March 2018
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 183 (suppl_1) , 162-168
Open AccessRetrospective Analysis of Esophageal Heat Transfer for Active Temperature Management in Post-cardiac Arrest, Refractory Fever, and Burn Patients
Core temperature management is an important aspect of critical care; preventing unintentional hypothermia, reducing fever, and inducing therapeutic hypothermia when appropriate are each tied to positive health outcomes. The purpose of this study is to evaluate the performance of a new temperature management device that uses the esophageal environment to conduct heat transfer. De-identified patient data were aggregated from three clinical sites where an esophageal heat transfer device (EHTD) was used to provide temperature management. The device was evaluated against temperature management guidelines and best practice recommendations, including performance during induction, maintenance, and cessation of therapy. Across all active cooling protocols, the average time-to-target was 2.37 h and the average maintenance phase was 22.4 h. Patients spent 94.9% of the maintenance phase within ±1.0°C and 67.2% within ±0.5°C (574 and 407 measurements, respectively, out of 605 total). For warming protocols, all of the patient temperature readings remained above 36°C throughout the surgical procedure (average 4.66 h). The esophageal heat transfer device met performance expectations across a range of temperature management applications in intensive care and burn units. Patients met and maintained temperature goals without any reported adverse events.
- 1 February 2018
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 34 (2) , 156-167
Cardiac Intensive Care Unit Management of Patients After Cardiac Arrest: Now the Real Work Begins
- 1 February 2018
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 34 (2) , 156-167
Cardiac Intensive Care Unit Management of Patients After Cardiac Arrest: Now the Real Work Begins
- Open Access
- 21 November 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 129,p. e56579
Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Controlling patient temperature is important for a wide variety of clinical conditions. Cooling to normal or below normal body temperature is often performed for neuroprotection after ischemic insult (e.g. hemorrhagic stroke, subarachnoid hemorrhage, cardiac arrest, or other hypoxic injury). Cooling from febrile states treats fever and reduces the negative effects of hyperthermia on injured neurons. Patients are warmed in the operating room to prevent inadvertent perioperative hypothermia, which is known to cause increased blood loss, wound infections, and myocardial injury, while also prolonging recovery time. There are many reported approaches for temperature management, including improvised methods that repurpose standard supplies (e.g., ice, chilled saline, fans, blankets) but more sophisticated technologies designed for temperature management are typically more successful in delivering an optimized protocol. Over the last decade, advanced technologies have developed around two heat transfer methods: surface devices (water blankets, forced-air warmers) or intravascular devices (sterile catheters requiring vascular placement). Recently, a novel device became available that is placed in the esophagus, analogous to a standard orogastric tube, that provides efficient heat transfer through the patient's core. The device connects to existing heat exchange units to allow automatic patient temperature management via a servo mechanism, using patient temperature from standard temperature sensors (rectal, Foley, or other core temperature sensors) as the input variable. This approach eliminates vascular placement complications (deep venous thrombosis, central line associated bloodstream infection), reduces obstruction to patient access, and causes less shivering when compared to surface approaches. Published data have also shown a high degree of accuracy and maintenance of target temperature using the esophageal approach to temperature management. Therefore, the purpose of this method is to provide a low-risk alternative method for controlling patient temperature in critical care settings.
- 21 November 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 129,p. e56579
Open AccessEsophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Controlling patient temperature is important for a wide variety of clinical conditions. Cooling to normal or below normal body temperature is often performed for neuroprotection after ischemic insult (e.g. hemorrhagic stroke, subarachnoid hemorrhage, cardiac arrest, or other hypoxic injury). Cooling from febrile states treats fever and reduces the negative effects of hyperthermia on injured neurons. Patients are warmed in the operating room to prevent inadvertent perioperative hypothermia, which is known to cause increased blood loss, wound infections, and myocardial injury, while also prolonging recovery time. There are many reported approaches for temperature management, including improvised methods that repurpose standard supplies (e.g., ice, chilled saline, fans, blankets) but more sophisticated technologies designed for temperature management are typically more successful in delivering an optimized protocol. Over the last decade, advanced technologies have developed around two heat transfer methods: surface devices (water blankets, forced-air warmers) or intravascular devices (sterile catheters requiring vascular placement). Recently, a novel device became available that is placed in the esophagus, analogous to a standard orogastric tube, that provides efficient heat transfer through the patient's core. The device connects to existing heat exchange units to allow automatic patient temperature management via a servo mechanism, using patient temperature from standard temperature sensors (rectal, Foley, or other core temperature sensors) as the input variable. This approach eliminates vascular placement complications (deep venous thrombosis, central line associated bloodstream infection), reduces obstruction to patient access, and causes less shivering when compared to surface approaches. Published data have also shown a high degree of accuracy and maintenance of target temperature using the esophageal approach to temperature management. Therefore, the purpose of this method is to provide a low-risk alternative method for controlling patient temperature in critical care settings.