Carlos Uribe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos Uribe has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
- Arman Rahmim
The University of British Columbia
23 shared publications - François Bénard
BC Cancer Agency
13 shared publications Anna Celler
Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
7 shared publicationsJulia Brosch-Lenz
Institute of Nuclear Medicine, Glen Burnie, USA
7 shared publicationsArman Rahmim
Department of Integrative Oncology, Bc Cancer Research Institute, Vancouver, Canada
6 shared publications- Fereshteh Yousefirizi
Department of Basic and Translational Research, BC Cancer Research Institute, Vancouver, BC V5Z 1L3, Canada
5 shared publications
Latest Publications
- 30 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4)
Beyond the tumor: Recurrence-prone radiomics for prognostication in negative PSMA PET/CT scans of prostate cancer
Purpose: Prostate-specific membrane antigen (PSMA) PET/CT is routinely used to restage prostate cancer (PCa) in patients with biochemical recurrence (BCR), yet negative scans may still harbor subclinical disease. This study investigated whether radiomics features extracted from recurrence-prone organs on negative [¹⁸F]DCFPyL PET/CT can predict clinical progression (CP) and clinical progression-free survival (CPFS). Materials and Methods: We performed a post-hoc analysis of 132 patients with BCR (mean age, 74.5 years) who had negative [¹⁸F]DCFPyL PET/CT scans and received no further treatment after imaging. Recurrence-prone organs, defined as anatomical sites at highest risk for prostate cancer recurrence (prostate bed, lymph nodes, bones, liver, and lungs), were segmented using nnU-Net (TotalSegmentator), and radiomics features were extracted. Machine learning models (XGBoost) and Cox proportional hazards models were evaluated using nested cross-validation (5-fold outer, 3-fold inner). External validation across two independent centers was performed after ComBat harmonization. The effect of reader-assigned diagnostic certainty on predictive performance was also examined. Only recurrence-prone organs were analyzed, as prior studies have shown that more than 80% of PCa recurrences arise in these regions. Results: Median PSA at imaging was 0.74 ng/mL. During a median follow-up of 25.5 months, 42 of 132 patients (31.8%) developed progression. The concordance index improved from 0.65 using clinical variables alone to 0.74 when PET, CT, and clinical features were combined (p < 0.05). Predictive performance was strongly influenced by diagnostic certainty, with moderate-certainty negative scans showing higher accuracy than high-certainty negative scans. Radiomics features derived from negative PSMA PET/CT reflected systemic recurrence risk and were associated with early lung metastases. External validation demonstrated less than 10% reduction in performance despite inter-center differences. Conclusion: Radiomics signatures from recurrence-prone organs on negative PSMA PET/CT may reveal subclinical disease and provide complementary biomarkers for risk stratification in BCR patients.
- 30 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4)
Beyond the tumor: Recurrence-prone radiomics for prognostication in negative PSMA PET/CT scans of prostate cancer
Purpose: Prostate-specific membrane antigen (PSMA) PET/CT is routinely used to restage prostate cancer (PCa) in patients with biochemical recurrence (BCR), yet negative scans may still harbor subclinical disease. This study investigated whether radiomics features extracted from recurrence-prone organs on negative [¹⁸F]DCFPyL PET/CT can predict clinical progression (CP) and clinical progression-free survival (CPFS). Materials and Methods: We performed a post-hoc analysis of 132 patients with BCR (mean age, 74.5 years) who had negative [¹⁸F]DCFPyL PET/CT scans and received no further treatment after imaging. Recurrence-prone organs, defined as anatomical sites at highest risk for prostate cancer recurrence (prostate bed, lymph nodes, bones, liver, and lungs), were segmented using nnU-Net (TotalSegmentator), and radiomics features were extracted. Machine learning models (XGBoost) and Cox proportional hazards models were evaluated using nested cross-validation (5-fold outer, 3-fold inner). External validation across two independent centers was performed after ComBat harmonization. The effect of reader-assigned diagnostic certainty on predictive performance was also examined. Only recurrence-prone organs were analyzed, as prior studies have shown that more than 80% of PCa recurrences arise in these regions. Results: Median PSA at imaging was 0.74 ng/mL. During a median follow-up of 25.5 months, 42 of 132 patients (31.8%) developed progression. The concordance index improved from 0.65 using clinical variables alone to 0.74 when PET, CT, and clinical features were combined (p < 0.05). Predictive performance was strongly influenced by diagnostic certainty, with moderate-certainty negative scans showing higher accuracy than high-certainty negative scans. Radiomics features derived from negative PSMA PET/CT reflected systemic recurrence risk and were associated with early lung metastases. External validation demonstrated less than 10% reduction in performance despite inter-center differences. Conclusion: Radiomics signatures from recurrence-prone organs on negative PSMA PET/CT may reveal subclinical disease and provide complementary biomarkers for risk stratification in BCR patients.
- Open Access
- 23 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145005
Kernel-based Maximum likelihood reconstruction of attenuation and activity (MLAA) in SPECT imaging for improved attenuation correction and activity quantification: Simulation, phantom and patient validation studies
Objective: Quantitative SPECT/CT for radiopharmaceutical therapy relies on accurate attenuation map (µ-map). Because attenuation is energy dependent, CT-derived maps must be converted to radionuclide-specific values, typically via bilinear scaling (BLS), which can introduce bias to activity quantification. To address this, we investigate the application of a kernel-based maximum-likelihood attenuation and activity (MLAA) algorithm that incorporates CT-derived anatomical features and SPECT emission data to improve µ-map accuracy. Approach: The MLAA algorithm jointly estimates µ-map and activity distribution by maximizing the Poisson log likelihood. Activity is updated using standard OSEM, while the µ-map is refined via gradient ascent from a CT-derived initialization. However, standard MLAA suffers from attenuation–activity crosstalk. To mitigate this effect, we introduce kernel MLAA, incorporating CT-based features to enhance attenuation–activity separation and constrain µ-map updates. Performance was evaluated using Monte Carlo simulations and experimental data from both a NEMA phantom and a patient scan. The entire method is implemented in the PyTomography platform, which is publicly available and GPU-accelerated for efficient 3D reconstruction. Main results: In simulations, standard MLAA exhibited strong crosstalk artifacts, whereas kernel MLAA substantially suppressed these artifacts and reduced µ-map bias, achieving an approximately 84% decrease in liver voxel-wise MAE compared with BLS. It also improved activity quantification accuracy, with the recovery-coefficient bias converging to 0.90%±0.34% across 20 noise realizations. The simulated iodinated contrast–induced activity bias decreased from 18.11% to 1.51%. Phantom and patient data validated that kernel MLAA restored perturbed µ-values, reducing mean bias from 13.6% to 0.6% (phantom) and from 13.7% to 0.3% (patient). Noise remained controlled across iterations, whereas standard MLAA tended to amplify noise. Significance: Kernel MLAA provides a robust approach for improving attenuation correction in quantitative SPECT by automatically detecting and correcting µ-map bias, offering a potential solution when CT-derived attenuation maps are biased or unreliable.
- 23 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145005
Open AccessKernel-based Maximum likelihood reconstruction of attenuation and activity (MLAA) in SPECT imaging for improved attenuation correction and activity quantification: Simulation, phantom and patient validation studies
Objective: Quantitative SPECT/CT for radiopharmaceutical therapy relies on accurate attenuation map (µ-map). Because attenuation is energy dependent, CT-derived maps must be converted to radionuclide-specific values, typically via bilinear scaling (BLS), which can introduce bias to activity quantification. To address this, we investigate the application of a kernel-based maximum-likelihood attenuation and activity (MLAA) algorithm that incorporates CT-derived anatomical features and SPECT emission data to improve µ-map accuracy. Approach: The MLAA algorithm jointly estimates µ-map and activity distribution by maximizing the Poisson log likelihood. Activity is updated using standard OSEM, while the µ-map is refined via gradient ascent from a CT-derived initialization. However, standard MLAA suffers from attenuation–activity crosstalk. To mitigate this effect, we introduce kernel MLAA, incorporating CT-based features to enhance attenuation–activity separation and constrain µ-map updates. Performance was evaluated using Monte Carlo simulations and experimental data from both a NEMA phantom and a patient scan. The entire method is implemented in the PyTomography platform, which is publicly available and GPU-accelerated for efficient 3D reconstruction. Main results: In simulations, standard MLAA exhibited strong crosstalk artifacts, whereas kernel MLAA substantially suppressed these artifacts and reduced µ-map bias, achieving an approximately 84% decrease in liver voxel-wise MAE compared with BLS. It also improved activity quantification accuracy, with the recovery-coefficient bias converging to 0.90%±0.34% across 20 noise realizations. The simulated iodinated contrast–induced activity bias decreased from 18.11% to 1.51%. Phantom and patient data validated that kernel MLAA restored perturbed µ-values, reducing mean bias from 13.6% to 0.6% (phantom) and from 13.7% to 0.3% (patient). Noise remained controlled across iterations, whereas standard MLAA tended to amplify noise. Significance: Kernel MLAA provides a robust approach for improving attenuation correction in quantitative SPECT by automatically detecting and correcting µ-map bias, offering a potential solution when CT-derived attenuation maps are biased or unreliable.
- Open Access
- 12 March 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
An international study of factors affecting variability of dosimetry calculations, part 5: impact of segmentation methods
Background: Individualized radiopharmaceutical therapies guided by patient-specific absorbed dose assessments using imaging have the potential to improve both efficacy and safety. Understanding sources of variability in absorbed dose calculations is critical for standardization. The Society of Nuclear Medicine and Molecular Imaging Dosimetry Task Force launched the 177 Lu Dosimetry Challenge to evaluate variability across different steps within the dosimetry workflow. This work aimed to assess the variability in absorbed doses due to differences in segmentation methods. Methods: Anonymized datasets from two patients treated with 177 Lu-DOTATATE, including serial SPECT/CT scans, were made available online. Participants were asked to segment healthy organs and lesions and perform dosimetry calculations. In a subsequent task, participants were provided with standardized segmented VOIs and asked to perform dosimetry based on these pre-defined regions. Variability in segmentation was assessed by comparing absorbed dose estimates across two scenarios: participant-generated segmentations versus predefined reference segmentations. Relative absorbed dose variability was quantified using the quartile coefficient of dispersion (QCD) and interquartile range. Results: Variability in absorbed dose (measured as QCD difference between absorbed doses from participant-generated segmentations and those from reference segmentations) for kidneys was less than 5% in simple cases and 10.6% for more challenging scenarios (i.e. presence of intraparenchymal cysts, cortical defects). Lesion segmentation exhibited higher variability, with absorbed dose variability reaching up to 22.4%. Conclusions: Segmentation significantly contributes to variability in absorbed dose estimates, particularly for lesions and for kidneys with anatomical complexities. Standardizing segmentation protocols and providing training on advanced segmentation methods are essential to reduce variability.
- 12 March 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessAn international study of factors affecting variability of dosimetry calculations, part 5: impact of segmentation methods
Background: Individualized radiopharmaceutical therapies guided by patient-specific absorbed dose assessments using imaging have the potential to improve both efficacy and safety. Understanding sources of variability in absorbed dose calculations is critical for standardization. The Society of Nuclear Medicine and Molecular Imaging Dosimetry Task Force launched the 177 Lu Dosimetry Challenge to evaluate variability across different steps within the dosimetry workflow. This work aimed to assess the variability in absorbed doses due to differences in segmentation methods. Methods: Anonymized datasets from two patients treated with 177 Lu-DOTATATE, including serial SPECT/CT scans, were made available online. Participants were asked to segment healthy organs and lesions and perform dosimetry calculations. In a subsequent task, participants were provided with standardized segmented VOIs and asked to perform dosimetry based on these pre-defined regions. Variability in segmentation was assessed by comparing absorbed dose estimates across two scenarios: participant-generated segmentations versus predefined reference segmentations. Relative absorbed dose variability was quantified using the quartile coefficient of dispersion (QCD) and interquartile range. Results: Variability in absorbed dose (measured as QCD difference between absorbed doses from participant-generated segmentations and those from reference segmentations) for kidneys was less than 5% in simple cases and 10.6% for more challenging scenarios (i.e. presence of intraparenchymal cysts, cortical defects). Lesion segmentation exhibited higher variability, with absorbed dose variability reaching up to 22.4%. Conclusions: Segmentation significantly contributes to variability in absorbed dose estimates, particularly for lesions and for kidneys with anatomical complexities. Standardizing segmentation protocols and providing training on advanced segmentation methods are essential to reduce variability.
- Open Access
Pre-Treatment PET Radiomics for Prediction of Disease-Free Survival in Cervical Cancer
Background: Cervical cancer remains a major global health concern, with high recurrence rates in advanced stages. [18F]FDG PET/CT provides prognostic biomarkers such as SUV, MTV, and TLG, though these are not routinely integrated into clinical protocols. Radiomics offers quantitative analysis of tumor heterogeneity, supporting risk stratification. Purpose: To evaluate the prognostic value of clinical and radiomic features for disease-free survival (DFS) in locoregionally advanced cervical cancer using machine learning (ML). Methods: Sixty-three patients (mean age 47.9 ± 14.5 years) were diagnosed between 2015 and 2020. Radiomic features were extracted from pre-treatment PET/CT (IBSI-compliant PyRadiomics). Clinical variables included age, T-stage, Dmax, lymph node involvement, SUVmax, and TMTV. Forty-two models were built by combining six feature-selection techniques (UCI, MD, MI, VH, VH.VIMP, IBMA) with seven ML algorithms (CoxPH, CB, GLMN, GLMB, RSF, ST, EV) using nested 3-fold cross-validation with bootstrap resampling. External validation was performed on 95 patients (mean age 50.6 years, FIGO IIB–IIIB) from an independent cohort with different preprocessing protocols. Results: Recurrence occurred in 31.7% (n = 20). SUVmax of lymph nodes, lymph node involvement, and TMTV were the most predictive individual features (C-index ≤ 0.77). The highest performance was achieved by UCI + EV/GLMB on combined clinical + radiomic features (C-index = 0.80, p < 0.05). For single feature sets, IBMA + RSF performed best for clinical (C-index = 0.72), and VH.VIMP + GLMN for radiomics (C-index = 0.71). External validation confirmed moderate generalizability (best C-index = 0.64). Conclusions: UCI-based feature selection with GLMB or EV yielded the best predictive accuracy, while VH.VIMP + GLMN offered superior external generalizability for radiomics-only models. These findings support the feasibility of integrating radiomics and ML for individualized DFS risk stratification in cervical cancer.
Open AccessPre-Treatment PET Radiomics for Prediction of Disease-Free Survival in Cervical Cancer
Background: Cervical cancer remains a major global health concern, with high recurrence rates in advanced stages. [18F]FDG PET/CT provides prognostic biomarkers such as SUV, MTV, and TLG, though these are not routinely integrated into clinical protocols. Radiomics offers quantitative analysis of tumor heterogeneity, supporting risk stratification. Purpose: To evaluate the prognostic value of clinical and radiomic features for disease-free survival (DFS) in locoregionally advanced cervical cancer using machine learning (ML). Methods: Sixty-three patients (mean age 47.9 ± 14.5 years) were diagnosed between 2015 and 2020. Radiomic features were extracted from pre-treatment PET/CT (IBSI-compliant PyRadiomics). Clinical variables included age, T-stage, Dmax, lymph node involvement, SUVmax, and TMTV. Forty-two models were built by combining six feature-selection techniques (UCI, MD, MI, VH, VH.VIMP, IBMA) with seven ML algorithms (CoxPH, CB, GLMN, GLMB, RSF, ST, EV) using nested 3-fold cross-validation with bootstrap resampling. External validation was performed on 95 patients (mean age 50.6 years, FIGO IIB–IIIB) from an independent cohort with different preprocessing protocols. Results: Recurrence occurred in 31.7% (n = 20). SUVmax of lymph nodes, lymph node involvement, and TMTV were the most predictive individual features (C-index ≤ 0.77). The highest performance was achieved by UCI + EV/GLMB on combined clinical + radiomic features (C-index = 0.80, p < 0.05). For single feature sets, IBMA + RSF performed best for clinical (C-index = 0.72), and VH.VIMP + GLMN for radiomics (C-index = 0.71). External validation confirmed moderate generalizability (best C-index = 0.64). Conclusions: UCI-based feature selection with GLMB or EV yielded the best predictive accuracy, while VH.VIMP + GLMN offered superior external generalizability for radiomics-only models. These findings support the feasibility of integrating radiomics and ML for individualized DFS risk stratification in cervical cancer.
- Open Access
- 11 September 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (10) , 1528-1537
Summary: SNMMI/ACNM Procedure Standard for Posttreatment Imaging of 177Lu-Based Radiopharmaceuticals
- 11 September 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (10) , 1528-1537
Open AccessSummary: SNMMI/ACNM Procedure Standard for Posttreatment Imaging of 177Lu-Based Radiopharmaceuticals
- Open Access
- 8 July 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-29
S-values for bone marrow dosimetry in preclinical radiopharmaceutical studies with rodents
Background: Development of novel radiopharmaceuticals involves dosimetry calculations to validate safety and aid with selection of those that should be translated into the clinical environment. Dosimetry is critical for limiting radiation damage to organs at risk. The bone marrow is a limiting organ in radiopharmaceutical therapies (RPTs) for metastatic prostate cancer, for example, but there is room for improvement of bone marrow dosimetry in preclinical studies. Bone marrow S-values for Lutetium-177 (177Lu) in rodents have been published but they have not included tumor xenografts inoculated in the shoulder, which is how radiopharmaceuticals are often tested. Here, we aim at performing Monte Carlo simulations on digital mice phantoms including tumor xenografts, and to determine new bone marrow S-values that can potentially improve our understanding of the effect of RPTs in blood cells. Methods: S-values for 177Lu were simulated in the 4D Mouse Whole Body (MOBY) phantom, a hybrid voxel-based mouse model, using GATE v9.3 MC toolkit. Two phantoms of different resolutions and equal mass were created. 3D dose distributions were simulated and the corresponding organ to organ S-values were calculated. The resulting S-values were validated against reference values from OLINDA v2.2.3. Later, tumours of varying sizes were placed in the left shoulder and tumour-to-organ S-values were calculated from MC simulations with a 177Lu source placed uniformly in these tumours. Results: The phantoms simulated here differed from the OLINDA phantom in both organ mass and geometry for many tissues; S-value deviations from OLINDA were correlated with these differences, as reported in previous studies, and ranged from 2% for the kidney self-dose in the higher resolution (HR) phantom to 477% for S(skeleton←spleen) in the lower resolution (LR) phantom. S-values were simulated for the bone marrow in both phantoms; cross-dose values were greatest from the skeleton, brain, and lungs, while cross-doses from the simulated tumours were approximately constant at 3 × 10–15 Gy Bq−1 s−1 across all tumour sizes. The components of the skeleton receiving the greatest tumour cross-doses from the tumours were the spine, skull and marrow. S-values targeting the bone marrow were compared to similar values from a previous study, whose phantom differed in tissue composition—discrepancies ranged from 6% for S(BM←kidneys) at LR to 87% for S(BM←BM) at HR. In general, relative uncertainty in dose and dose factor deposited from one tissue to another was inversely proportional to the corresponding S-value magnitude, and lower uncertainties were yielded from simulations in the LR, large-voxel phantom. Conclusion: Using the MOBY digital mouse phantom, we simulated bone marrow S-values for 177Lu. We hope these values help researchers perform preclinical dosimetry in rodents including bone marrow and tumor xenografts and facilitate the translation of novel radiopharmaceuticals.
- 8 July 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-29
Open AccessS-values for bone marrow dosimetry in preclinical radiopharmaceutical studies with rodents
Background: Development of novel radiopharmaceuticals involves dosimetry calculations to validate safety and aid with selection of those that should be translated into the clinical environment. Dosimetry is critical for limiting radiation damage to organs at risk. The bone marrow is a limiting organ in radiopharmaceutical therapies (RPTs) for metastatic prostate cancer, for example, but there is room for improvement of bone marrow dosimetry in preclinical studies. Bone marrow S-values for Lutetium-177 (177Lu) in rodents have been published but they have not included tumor xenografts inoculated in the shoulder, which is how radiopharmaceuticals are often tested. Here, we aim at performing Monte Carlo simulations on digital mice phantoms including tumor xenografts, and to determine new bone marrow S-values that can potentially improve our understanding of the effect of RPTs in blood cells. Methods: S-values for 177Lu were simulated in the 4D Mouse Whole Body (MOBY) phantom, a hybrid voxel-based mouse model, using GATE v9.3 MC toolkit. Two phantoms of different resolutions and equal mass were created. 3D dose distributions were simulated and the corresponding organ to organ S-values were calculated. The resulting S-values were validated against reference values from OLINDA v2.2.3. Later, tumours of varying sizes were placed in the left shoulder and tumour-to-organ S-values were calculated from MC simulations with a 177Lu source placed uniformly in these tumours. Results: The phantoms simulated here differed from the OLINDA phantom in both organ mass and geometry for many tissues; S-value deviations from OLINDA were correlated with these differences, as reported in previous studies, and ranged from 2% for the kidney self-dose in the higher resolution (HR) phantom to 477% for S(skeleton←spleen) in the lower resolution (LR) phantom. S-values were simulated for the bone marrow in both phantoms; cross-dose values were greatest from the skeleton, brain, and lungs, while cross-doses from the simulated tumours were approximately constant at 3 × 10–15 Gy Bq−1 s−1 across all tumour sizes. The components of the skeleton receiving the greatest tumour cross-doses from the tumours were the spine, skull and marrow. S-values targeting the bone marrow were compared to similar values from a previous study, whose phantom differed in tissue composition—discrepancies ranged from 6% for S(BM←kidneys) at LR to 87% for S(BM←BM) at HR. In general, relative uncertainty in dose and dose factor deposited from one tissue to another was inversely proportional to the corresponding S-value magnitude, and lower uncertainties were yielded from simulations in the LR, large-voxel phantom. Conclusion: Using the MOBY digital mouse phantom, we simulated bone marrow S-values for 177Lu. We hope these values help researchers perform preclinical dosimetry in rodents including bone marrow and tumor xenografts and facilitate the translation of novel radiopharmaceuticals.
- Open Access
Computer-Aided Detection (CADe) of Small Metastatic Prostate Cancer Lesions on 3D PSMA PET Volumes Using Multi-Angle Maximum Intensity Projections
Objectives: We aimed to develop and evaluate a novel computer-aided detection (CADe) approach for identifying small metastatic biochemically recurrent (BCR) prostate cancer (PCa) lesions on PSMA-PET images, utilizing multi-angle Maximum Intensity Projections (MA-MIPs) and state-of-the-art (SOTA) object detection algorithms. Methods: We fine-tuned and evaluated 16 SOTA object detection algorithms (selected across four main categories of model types) applied to MA-MIPs as extracted from rotated 3D PSMA-PET volumes. Predicted 2D bounding boxes were back-projected to the original 3D space using the Ordered Subset Expectation Maximization (OSEM) algorithm. A fine-tuned Medical Segment-Anything Model (MedSAM) was then also used to segment the identified lesions within the bounding boxes. Results: The proposed method achieved a high detection performance for this difficult task, with the FreeAnchor model reaching an F1-score of 0.69 and a recall of 0.74. It outperformed several 3D methods in efficiency while maintaining comparable accuracy. Strong recall rates were observed for clinically relevant areas, such as local relapses (0.82) and bone metastases (0.80). Conclusion: Our fully automated CADe tool shows promise in assisting physicians as a “second reader” for detecting small metastatic BCR PCa lesions on PSMA-PET images. By leveraging the strength and computational efficiency of 2D models while preserving 3D spatial information of the PSMA-PET volume, the proposed approach has the potential to improve detectability and reduce workload in cancer diagnosis and management.
Open AccessComputer-Aided Detection (CADe) of Small Metastatic Prostate Cancer Lesions on 3D PSMA PET Volumes Using Multi-Angle Maximum Intensity Projections
Objectives: We aimed to develop and evaluate a novel computer-aided detection (CADe) approach for identifying small metastatic biochemically recurrent (BCR) prostate cancer (PCa) lesions on PSMA-PET images, utilizing multi-angle Maximum Intensity Projections (MA-MIPs) and state-of-the-art (SOTA) object detection algorithms. Methods: We fine-tuned and evaluated 16 SOTA object detection algorithms (selected across four main categories of model types) applied to MA-MIPs as extracted from rotated 3D PSMA-PET volumes. Predicted 2D bounding boxes were back-projected to the original 3D space using the Ordered Subset Expectation Maximization (OSEM) algorithm. A fine-tuned Medical Segment-Anything Model (MedSAM) was then also used to segment the identified lesions within the bounding boxes. Results: The proposed method achieved a high detection performance for this difficult task, with the FreeAnchor model reaching an F1-score of 0.69 and a recall of 0.74. It outperformed several 3D methods in efficiency while maintaining comparable accuracy. Strong recall rates were observed for clinically relevant areas, such as local relapses (0.82) and bone metastases (0.80). Conclusion: Our fully automated CADe tool shows promise in assisting physicians as a “second reader” for detecting small metastatic BCR PCa lesions on PSMA-PET images. By leveraging the strength and computational efficiency of 2D models while preserving 3D spatial information of the PSMA-PET volume, the proposed approach has the potential to improve detectability and reduce workload in cancer diagnosis and management.
- Open Access
- 23 March 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (4) , 449
Novel 177Lu-Labeled [Thz14]Bombesin(6–14) Derivatives with Low Pancreas Accumulation for Targeting Gastrin-Releasing Peptide Receptor-Expressing Cancer
Background/Objectives: Gastrin-releasing peptide receptor is a promising target for cancer diagnosis and therapy. However, the high pancreas uptake of reported GRPR-targeted radioligands limits their clinical applications. Our group previously reported one 68Ga-labeled GRPR antagonist, [68Ga]Ga-TacsBOMB5 (68Ga-DOTA-Pip-[D-Phe6,NMe-Gly11,Leu13ψThz14]Bombesin(6–14)), and two agonists, [68Ga]Ga-LW01110 (68Ga-DOTA-Pip-[D-Phe6,Tle10,NMe-His12,Thz14]Bombesin(6–14)) and [68Ga]Ga-LW01142 (68Ga-DOTA-Pip-[D-Phe6,His7,Tle10,NMe-His12,Thz14]Bombesin(6–14)) showing minimal pancreas uptake. Thus, in this study, we prepared their 177Lu-labeled analogs, evaluated their therapeutic potentials, and compared them with the clinically evaluated [177Lu]Lu-AMBA. Methods: GRPR binding affinities were determined by in vitro competition binding assay using PC-3 prostate cancer cells. Longitudinal SPECT/CT imaging and ex vivo biodistribution studies were conducted in PC-3 tumor-bearing mice. Dosimetry data were calculated from the biodistribution results. Results: The Ki(GRPR) values of Lu-TacsBOMB5, Lu-LW01110, Lu-LW01142, and Lu-AMBA were 12.6 ± 1.02, 3.07 ± 0.15, 2.37 ± 0.28, and 0.33 ± 0.16 nM, respectively. SPECT/CT images and biodistribution results demonstrated good tumor accumulation of [177Lu]Lu-TacsBOMB5, [177Lu]Lu-LW01110, and [177Lu]Lu-LW01142 at early time points with rapid clearance over time. The pancreas uptake of all three [Thz14]Bombesin(6–14)-derived ligands was significantly lower than that of [177Lu]Lu-AMBA at all time points. The calculated absorbed doses of [177Lu]Lu-TacsBOMB5, [177Lu]Lu-LW01110, and [177Lu]Lu-LW01142 in PC-3 tumor xenografts were 87.1, 312, and 312 mGy/MBq, respectively, higher than that of [177Lu]Lu-AMBA (79.1 mGy/MBq), but lower than that of the previously reported [177Lu]Lu-RM2 (429 mGy/MBq). Conclusions: Our data suggest that [177Lu]Lu-TacsBOMB5 and [177Lu]Lu-LW01142 reduce radiation exposure to the pancreas. However, further optimizations are needed for both radioligands to prolong their tumor retention and enhance treatment efficacy.
- 23 March 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (4) , 449
Open AccessNovel 177Lu-Labeled [Thz14]Bombesin(6–14) Derivatives with Low Pancreas Accumulation for Targeting Gastrin-Releasing Peptide Receptor-Expressing Cancer
Background/Objectives: Gastrin-releasing peptide receptor is a promising target for cancer diagnosis and therapy. However, the high pancreas uptake of reported GRPR-targeted radioligands limits their clinical applications. Our group previously reported one 68Ga-labeled GRPR antagonist, [68Ga]Ga-TacsBOMB5 (68Ga-DOTA-Pip-[D-Phe6,NMe-Gly11,Leu13ψThz14]Bombesin(6–14)), and two agonists, [68Ga]Ga-LW01110 (68Ga-DOTA-Pip-[D-Phe6,Tle10,NMe-His12,Thz14]Bombesin(6–14)) and [68Ga]Ga-LW01142 (68Ga-DOTA-Pip-[D-Phe6,His7,Tle10,NMe-His12,Thz14]Bombesin(6–14)) showing minimal pancreas uptake. Thus, in this study, we prepared their 177Lu-labeled analogs, evaluated their therapeutic potentials, and compared them with the clinically evaluated [177Lu]Lu-AMBA. Methods: GRPR binding affinities were determined by in vitro competition binding assay using PC-3 prostate cancer cells. Longitudinal SPECT/CT imaging and ex vivo biodistribution studies were conducted in PC-3 tumor-bearing mice. Dosimetry data were calculated from the biodistribution results. Results: The Ki(GRPR) values of Lu-TacsBOMB5, Lu-LW01110, Lu-LW01142, and Lu-AMBA were 12.6 ± 1.02, 3.07 ± 0.15, 2.37 ± 0.28, and 0.33 ± 0.16 nM, respectively. SPECT/CT images and biodistribution results demonstrated good tumor accumulation of [177Lu]Lu-TacsBOMB5, [177Lu]Lu-LW01110, and [177Lu]Lu-LW01142 at early time points with rapid clearance over time. The pancreas uptake of all three [Thz14]Bombesin(6–14)-derived ligands was significantly lower than that of [177Lu]Lu-AMBA at all time points. The calculated absorbed doses of [177Lu]Lu-TacsBOMB5, [177Lu]Lu-LW01110, and [177Lu]Lu-LW01142 in PC-3 tumor xenografts were 87.1, 312, and 312 mGy/MBq, respectively, higher than that of [177Lu]Lu-AMBA (79.1 mGy/MBq), but lower than that of the previously reported [177Lu]Lu-RM2 (429 mGy/MBq). Conclusions: Our data suggest that [177Lu]Lu-TacsBOMB5 and [177Lu]Lu-LW01142 reduce radiation exposure to the pancreas. However, further optimizations are needed for both radioligands to prolong their tumor retention and enhance treatment efficacy.
- Open Access
- 20 March 2025
- Published by The Open Journal in Journal of Open Source Software
- Vol. 10 (107) , 7361
RT-utils: A Minimal Python Library for RT-struct Manipulation
In the pursuit of automated and precise analysis of medical images using artificial intelligence, we introduce RT-utils, a specialized Python library designed to simplify the handling of radiotherapy imaging data. Medical images are commonly stored in the DICOM standard (Digital Imaging and Communications in Medicine), which is the universal format for sharing medical imaging information. In radiotherapy, the region of interests (ROIs) around the critical structures like tumors and surrounding organs are represented as detailed contours within DICOM files, specifically in what is known as the RTSTRUCT files (Radiotherapy Structure). RT-utils excels at converting these complex polygonal contours into straightforward binary masks. These masks are essentially grids where each point indicates the presence or absence of a structure, making them ideal for computational processing. By transforming DICOM radiotherapy structures into standardized data formats like NumPy arrays and SimpleITK images, RT-utils streamline the input for AI-based segmentation techniques and radiomics analysis, which are methods used to extract quantitative features from medical images. Since its inception in 2020, RT-utils has been widely adopted to simplify complex data processing tasks in medical imaging. It offers researchers and developers a powerful tool to enhance their workflows, ultimately driving significant advancements in medical image analysis and contributing to improved patient care.
- 20 March 2025
- Published by The Open Journal in Journal of Open Source Software
- Vol. 10 (107) , 7361
Open AccessRT-utils: A Minimal Python Library for RT-struct Manipulation
In the pursuit of automated and precise analysis of medical images using artificial intelligence, we introduce RT-utils, a specialized Python library designed to simplify the handling of radiotherapy imaging data. Medical images are commonly stored in the DICOM standard (Digital Imaging and Communications in Medicine), which is the universal format for sharing medical imaging information. In radiotherapy, the region of interests (ROIs) around the critical structures like tumors and surrounding organs are represented as detailed contours within DICOM files, specifically in what is known as the RTSTRUCT files (Radiotherapy Structure). RT-utils excels at converting these complex polygonal contours into straightforward binary masks. These masks are essentially grids where each point indicates the presence or absence of a structure, making them ideal for computational processing. By transforming DICOM radiotherapy structures into standardized data formats like NumPy arrays and SimpleITK images, RT-utils streamline the input for AI-based segmentation techniques and radiomics analysis, which are methods used to extract quantitative features from medical images. Since its inception in 2020, RT-utils has been widely adopted to simplify complex data processing tasks in medical imaging. It offers researchers and developers a powerful tool to enhance their workflows, ultimately driving significant advancements in medical image analysis and contributing to improved patient care.