Srinivas Gude
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Srinivas Gude has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chia-Chi Chu
National Tsing Hua University
8 shared publications - Mohanraj Bellie Subramani
Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan
2 shared publications - Josep Maria Guerrero
Zhejiang University
1 shared publication Kuan-Chu Lin
Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan, R.O.C.
1 shared publicationRiver Chen
Advanced Product & Technology, Delta Electronics Inc., Taoyuan, Taiwan
1 shared publicationSam Li
Advanced Product & Technology, Delta Electronics Inc., Taoyuan, Taiwan
1 shared publication
Latest Publications
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 3525-3537
An Enhanced Performance of Stationary Reference Frame Controlled Three-Phase Vienna Rectifier Under Grid Voltage Disturbances
This paper introduces a novel control strategy for enhancing the performance of the three-phase Vienna rectifier when faced with grid voltage disturbances. Unlike conventional methods, which typically employ three control loops for current regulation, capacitor voltage balance, and output voltage control, the proposed approach integrates a fundamental frequency positive sequence (FFPS) extractor into the output voltage control loop. By incorporating Multiple Delayed Signal Cancellation (MDSC) filters as FFPS extractors, the system can isolate the FFPS component of the reference three-phase grid currents. Additionally, the design of the output voltage controller, employing MDSC filters, is optimized symmetrically. Real-time simulations with case studies validate the effectiveness of this control method in mitigating current total harmonic distortion (THD), reducing capacitor ripple voltages, and minimizing output voltage ripple, particularly in the presence of grid voltage disturbances.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 3525-3537
An Enhanced Performance of Stationary Reference Frame Controlled Three-Phase Vienna Rectifier Under Grid Voltage Disturbances
This paper introduces a novel control strategy for enhancing the performance of the three-phase Vienna rectifier when faced with grid voltage disturbances. Unlike conventional methods, which typically employ three control loops for current regulation, capacitor voltage balance, and output voltage control, the proposed approach integrates a fundamental frequency positive sequence (FFPS) extractor into the output voltage control loop. By incorporating Multiple Delayed Signal Cancellation (MDSC) filters as FFPS extractors, the system can isolate the FFPS component of the reference three-phase grid currents. Additionally, the design of the output voltage controller, employing MDSC filters, is optimized symmetrically. Real-time simulations with case studies validate the effectiveness of this control method in mitigating current total harmonic distortion (THD), reducing capacitor ripple voltages, and minimizing output voltage ripple, particularly in the presence of grid voltage disturbances.
- Open Access
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 162327-162346
A Comparative Analysis of MDSC-Based Phasor Estimation Technique for Digital Relays in Power System Protection
Decaying DC offset frequently emerges as a major issue in power systems, especially under fault conditions. This leads to a distortion in the current waveform associated with the fault, which could significantly challenge protective and control mechanisms, possibly leading to their malfunction or breakdown. These decaying DC components (DDCs) complicate the extraction of critical parameters such as the current magnitude and phase angle of the fundamental frequency component from fault signals, which is crucial for the accurate operation of protective relays. Discrete Fourier Transform (DFT)-based algorithms are frequently used for phasor estimation, but their accuracy suffers when confronted with decaying DC components (DDCs) in power system fault currents. The low sampling rate further exacerbates the inaccuracy of DFT-based estimations, leading to inaccurate fault detection by protective relays. This paper comprehensively reviews three innovative methods that leverage the Multiple Delayed Signal Cancellation (MDSC) filter to overcome these limitations. The MDSC-based phasor estimation effectively attenuates the DDC component, enabling precise and rapid phasor estimation, benefiting from its higher sampling rate, and enhancing accuracy in relaying applications. The theoretical foundations of each method are analyzed, with an emphasis on their unique advantages and potential applications in digital relaying and power system protection. This review provides valuable insights into the latest advancements in DDC elimination, offering a pathway to more reliable and efficient fault analysis in power systems. Numerical and simulation tests unequivocally demonstrated the effectiveness of the proposed approach by showcasing its superior performance compared to four other phasor estimation methods. The proposed methods demonstrated exceptional performance in conditions plagued by multiple DDCs, harmonics, noise, and off-nominal frequency achieving fast and precise phasor estimation.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 162327-162346
Open AccessA Comparative Analysis of MDSC-Based Phasor Estimation Technique for Digital Relays in Power System Protection
Decaying DC offset frequently emerges as a major issue in power systems, especially under fault conditions. This leads to a distortion in the current waveform associated with the fault, which could significantly challenge protective and control mechanisms, possibly leading to their malfunction or breakdown. These decaying DC components (DDCs) complicate the extraction of critical parameters such as the current magnitude and phase angle of the fundamental frequency component from fault signals, which is crucial for the accurate operation of protective relays. Discrete Fourier Transform (DFT)-based algorithms are frequently used for phasor estimation, but their accuracy suffers when confronted with decaying DC components (DDCs) in power system fault currents. The low sampling rate further exacerbates the inaccuracy of DFT-based estimations, leading to inaccurate fault detection by protective relays. This paper comprehensively reviews three innovative methods that leverage the Multiple Delayed Signal Cancellation (MDSC) filter to overcome these limitations. The MDSC-based phasor estimation effectively attenuates the DDC component, enabling precise and rapid phasor estimation, benefiting from its higher sampling rate, and enhancing accuracy in relaying applications. The theoretical foundations of each method are analyzed, with an emphasis on their unique advantages and potential applications in digital relaying and power system protection. This review provides valuable insights into the latest advancements in DDC elimination, offering a pathway to more reliable and efficient fault analysis in power systems. Numerical and simulation tests unequivocally demonstrated the effectiveness of the proposed approach by showcasing its superior performance compared to four other phasor estimation methods. The proposed methods demonstrated exceptional performance in conditions plagued by multiple DDCs, harmonics, noise, and off-nominal frequency achieving fast and precise phasor estimation.
- 24 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (1) , 740-751
Dynamic Performance Enhancement of Single-Phase and Two-Phase Enhanced Phase-Locked Loops by Using In-Loop Multiple Delayed Signal Cancellation Filters
The estimation of phase-angle, frequency, and amplitude are vital for the control of grid-connected power electronic systems in both single-phase and three-phase systems. The single-phase enhanced phase-locked loop (1P-EPLL) and two-phase enhanced phase-locked loop (2P-EPLL) techniques can be used to estimate single-phase and three-phase grid voltage quantities, respectively. However, under the presence of harmonics, unbalance, and dc offsets, the estimated quantities by these enhanced phase-locked loops (EPLLs) may contain periodic ripples. These periodic ripples are eliminated by using multiple delayed signal cancellation (MDSC) filters in the phase-angle estimation loop and amplitude estimation loop of these EPLLs. To improve the dynamic responses of MDSC-based EPLLs, proportional-integral (PI) controller is replaced with a proportional-integral-derivative (PID) controller. The design guidelines for choosing the control parameters are provided. The MDSC filters in the EPLLs are realized both in direct-form and recursive-form structures. The proposed EPLLs are verified experimentally by using real-time system and compared with recent advanced EPLLs.
- 24 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (1) , 740-751
Dynamic Performance Enhancement of Single-Phase and Two-Phase Enhanced Phase-Locked Loops by Using In-Loop Multiple Delayed Signal Cancellation Filters
The estimation of phase-angle, frequency, and amplitude are vital for the control of grid-connected power electronic systems in both single-phase and three-phase systems. The single-phase enhanced phase-locked loop (1P-EPLL) and two-phase enhanced phase-locked loop (2P-EPLL) techniques can be used to estimate single-phase and three-phase grid voltage quantities, respectively. However, under the presence of harmonics, unbalance, and dc offsets, the estimated quantities by these enhanced phase-locked loops (EPLLs) may contain periodic ripples. These periodic ripples are eliminated by using multiple delayed signal cancellation (MDSC) filters in the phase-angle estimation loop and amplitude estimation loop of these EPLLs. To improve the dynamic responses of MDSC-based EPLLs, proportional-integral (PI) controller is replaced with a proportional-integral-derivative (PID) controller. The design guidelines for choosing the control parameters are provided. The MDSC filters in the EPLLs are realized both in direct-form and recursive-form structures. The proposed EPLLs are verified experimentally by using real-time system and compared with recent advanced EPLLs.
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 5383-5394
Recursive Implementation of Multiple Delayed Signal Cancellation Operators and Their Applications in Prefiltered and In-Loop Filtered PLLs Under Adverse Grid Conditions
Phase-locked loops (PLLs) are widely utilized for grid synchronization and control of power electronic converters. More recently, both in-loop filtered and pre-filtered based PLLs have become more popular due to their prompt and accurate estimations of grid voltage quantities. In the past, an advanced filter viz., multiple delayed signal cancellation (MDSC) operators, have been successfully investigated in both $\alpha\beta$ -frame and $dq$ -frame for extracting fundamental-frequency positive-sequence (FFPS) grid voltage quantities by using conventional synchronous reference frame (SRF)-PLL. These operators can provide more flexibility to configure the delay time and undesired harmonics in comparison with the existing cascaded delayed signal cancellation (CDSC) operators. In this paper, the recursive-form structures of MDSC operators are analysed, which are derived from the direct-form MDSC realizations. The recursive-form structures of MDSC operators are simple in implementation when compared to direct-form realizations. With the recursive-form MDSC implementations, both pre-filtered MDSC-PLL and in-loop filtered MDSC-PLL will be investigated in details. The design guidelines of these recursive-form based MDSC-PLLs are presented. Comparison studies of the proposed PLLs and the validation of their dynamic performances are done by experimental verifications.- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 5383-5394
Recursive Implementation of Multiple Delayed Signal Cancellation Operators and Their Applications in Prefiltered and In-Loop Filtered PLLs Under Adverse Grid Conditions
Phase-locked loops (PLLs) are widely utilized for grid synchronization and control of power electronic converters. More recently, both in-loop filtered and pre-filtered based PLLs have become more popular due to their prompt and accurate estimations of grid voltage quantities. In the past, an advanced filter viz., multiple delayed signal cancellation (MDSC) operators, have been successfully investigated in both $\alpha\beta$ -frame and $dq$ -frame for extracting fundamental-frequency positive-sequence (FFPS) grid voltage quantities by using conventional synchronous reference frame (SRF)-PLL. These operators can provide more flexibility to configure the delay time and undesired harmonics in comparison with the existing cascaded delayed signal cancellation (CDSC) operators. In this paper, the recursive-form structures of MDSC operators are analysed, which are derived from the direct-form MDSC realizations. The recursive-form structures of MDSC operators are simple in implementation when compared to direct-form realizations. With the recursive-form MDSC implementations, both pre-filtered MDSC-PLL and in-loop filtered MDSC-PLL will be investigated in details. The design guidelines of these recursive-form based MDSC-PLLs are presented. Comparison studies of the proposed PLLs and the validation of their dynamic performances are done by experimental verifications.- 8 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 7122-7133
Single-Phase Enhanced Phase-Locked Loops Based on Multiple Delayed Signal Cancellation Filters for Micro-Grid Applications
The grid voltage information such as the phase-angle, the frequency, and the amplitude, is crucial for the design of synchronization and control of power converters in the micro-grid. The conventional approach to estimate the grid voltage information is accomplished by phase-locked loop (PLL) techniques. Among various existing PLL techniques, filter-based PLLs can provide more accurate estimations even under adverse grid conditions. In this paper, a new single-phase filtering technique based on multiple delayed signal cancellation (MDSC) is proposed for extracting both in-phase and quadrature components of the selected harmonic order of the single-phase grid voltage signal. This MDSC technique can be realized in both the direct-form and the recursive-form. In comparison with existing single-phase cascaded delayed signal cancellation (CDSC) techniques, this MDSC technique utilizes less memory for the extraction of grid voltage fundamental frequency component. The proposed MDSC filter can be applied as a pre-filter to the enhanced phase-locked loop (EPLL) for the prompt and accurate estimations of the grid voltage information under adverse grid conditions. Both frequency adaptive and non-adaptive MDSC based EPLL schemes are proposed in this paper. To validate the effectiveness of the proposed methods, experiments are conducted on the MDSC based EPLLs and compared with the CDSC-EPLL under various grid voltage disturbances.
- 8 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 7122-7133
Single-Phase Enhanced Phase-Locked Loops Based on Multiple Delayed Signal Cancellation Filters for Micro-Grid Applications
The grid voltage information such as the phase-angle, the frequency, and the amplitude, is crucial for the design of synchronization and control of power converters in the micro-grid. The conventional approach to estimate the grid voltage information is accomplished by phase-locked loop (PLL) techniques. Among various existing PLL techniques, filter-based PLLs can provide more accurate estimations even under adverse grid conditions. In this paper, a new single-phase filtering technique based on multiple delayed signal cancellation (MDSC) is proposed for extracting both in-phase and quadrature components of the selected harmonic order of the single-phase grid voltage signal. This MDSC technique can be realized in both the direct-form and the recursive-form. In comparison with existing single-phase cascaded delayed signal cancellation (CDSC) techniques, this MDSC technique utilizes less memory for the extraction of grid voltage fundamental frequency component. The proposed MDSC filter can be applied as a pre-filter to the enhanced phase-locked loop (EPLL) for the prompt and accurate estimations of the grid voltage information under adverse grid conditions. Both frequency adaptive and non-adaptive MDSC based EPLL schemes are proposed in this paper. To validate the effectiveness of the proposed methods, experiments are conducted on the MDSC based EPLLs and compared with the CDSC-EPLL under various grid voltage disturbances.
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3832-3844
Three-Phase PLLs by Using Frequency Adaptive Multiple Delayed Signal Cancellation Prefilters Under Adverse Grid Conditions
Phase-locked loops (PLLs) are the most widely adopted techniques for synchronization of distributed generation units to the utility grid. However, when the grid voltage is polluted with severe unbalances and harmonics, the accuracy and performance of the conventional PLL will be deteriorated. This paper proposes a novel filtering technique, called the multiple delayed signal cancellation (MDSC), for improving the dynamic performance of the conventional synchronous reference frame (SRF)-PLL under adverse three-phase grid conditions. Theoretical developments of dq-frame and αβ-frame MDSC operators are investigated. The analysis shows that these MDSC operators can provide more flexibility to configure the lowest undesired harmonics. Since the MDSC operators possess multiple delayed signals in parallel, the delay time introduced by the operators can be reduced by selecting a suitable number of transfer delays. Therefore, the MDSC operators can be configured to have less delay time in comparison with the cascaded delayed signal cancellation operators with the same harmonic elimination capability. These two MDSC operators are utilized as a prefiltering stage to the conventional SRF-PLL to improve the dynamic responses. Since MDSC operators are dependent on grid frequency excursions, a new frequency adaptation scheme for the MDSC operators is also proposed for providing fast grid frequency estimations in designing the MDSC prefilter based PLLs. Experimental verifications demonstrate the effectiveness of the proposed PLLs and provide good dynamic responses when compared with the recent advanced PLLs.
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3832-3844
Three-Phase PLLs by Using Frequency Adaptive Multiple Delayed Signal Cancellation Prefilters Under Adverse Grid Conditions
Phase-locked loops (PLLs) are the most widely adopted techniques for synchronization of distributed generation units to the utility grid. However, when the grid voltage is polluted with severe unbalances and harmonics, the accuracy and performance of the conventional PLL will be deteriorated. This paper proposes a novel filtering technique, called the multiple delayed signal cancellation (MDSC), for improving the dynamic performance of the conventional synchronous reference frame (SRF)-PLL under adverse three-phase grid conditions. Theoretical developments of dq-frame and αβ-frame MDSC operators are investigated. The analysis shows that these MDSC operators can provide more flexibility to configure the lowest undesired harmonics. Since the MDSC operators possess multiple delayed signals in parallel, the delay time introduced by the operators can be reduced by selecting a suitable number of transfer delays. Therefore, the MDSC operators can be configured to have less delay time in comparison with the cascaded delayed signal cancellation operators with the same harmonic elimination capability. These two MDSC operators are utilized as a prefiltering stage to the conventional SRF-PLL to improve the dynamic responses. Since MDSC operators are dependent on grid frequency excursions, a new frequency adaptation scheme for the MDSC operators is also proposed for providing fast grid frequency estimations in designing the MDSC prefilter based PLLs. Experimental verifications demonstrate the effectiveness of the proposed PLLs and provide good dynamic responses when compared with the recent advanced PLLs.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 5293-5305
Dynamic Performance Improvement of Multiple Delayed Signal Cancelation Filters Based Three-Phase Enhanced-PLL
Phase-locked loop (PLL) techniques are widely utilized for synchronization and control of grid-connected power electronic systems for estimation of phase angle, frequency, and amplitude of the grid voltage. Recently, an advanced scheme called the three-phase enhanced PLL (3P-EPLL) has been proposed for estimating the grid voltage information. However, recent studies have shown that this 3P-EPLL cannot provide accurate estimations under adverse grid conditions, especially when the grid voltage is polluted with harmonics, dc offsets, and unbalance. This paper proposes an improved scheme of 3P-EPLL. A novel filtering technique called the multiple delayed signal cancelation (MDSC) is integrated into both the phase-angle estimation loop, and the amplitude estimation loop of the 3P-EPLL for eliminating periodic ripples due to harmonics and unbalance in the grid voltage. MDSC filters can indeed provide more flexibility to configure the lowest undesired harmonics, and can have less delay time in the digital implementations when compared with moving average filters and cascaded delayed signal cancelation filters. Thus, the fast response time of the filter is expected. To improve the dynamic performance of the 3P-EPLL, the proportional-integral-derivative controller is used instead of the conventional proportional-integral controller. Comprehensive analysis of the MDSC-based 3P-EPLL is investigated. Both simulations and experimental studies are conducted to validate the prompt dynamic performance of the proposed MDSC-based 3P-EPLL.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 5293-5305
Dynamic Performance Improvement of Multiple Delayed Signal Cancelation Filters Based Three-Phase Enhanced-PLL
Phase-locked loop (PLL) techniques are widely utilized for synchronization and control of grid-connected power electronic systems for estimation of phase angle, frequency, and amplitude of the grid voltage. Recently, an advanced scheme called the three-phase enhanced PLL (3P-EPLL) has been proposed for estimating the grid voltage information. However, recent studies have shown that this 3P-EPLL cannot provide accurate estimations under adverse grid conditions, especially when the grid voltage is polluted with harmonics, dc offsets, and unbalance. This paper proposes an improved scheme of 3P-EPLL. A novel filtering technique called the multiple delayed signal cancelation (MDSC) is integrated into both the phase-angle estimation loop, and the amplitude estimation loop of the 3P-EPLL for eliminating periodic ripples due to harmonics and unbalance in the grid voltage. MDSC filters can indeed provide more flexibility to configure the lowest undesired harmonics, and can have less delay time in the digital implementations when compared with moving average filters and cascaded delayed signal cancelation filters. Thus, the fast response time of the filter is expected. To improve the dynamic performance of the 3P-EPLL, the proportional-integral-derivative controller is used instead of the conventional proportional-integral controller. Comprehensive analysis of the MDSC-based 3P-EPLL is investigated. Both simulations and experimental studies are conducted to validate the prompt dynamic performance of the proposed MDSC-based 3P-EPLL.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
An efficient method for small-signal stability assessment of P − ƒ/Q − V̇ droop control in an isolated micro-grid
An efficient method for small-signal stability assessment of P − ƒ/Q − V̇ droop control methods for multiple converters in an isolated micro-grid (MG) is proposed in this paper. A MG model described with arbitrary number of converters is explored first. If there are more number of converters in a chosen MG, only dominant eigenvalues related to droop control are of primary interest. Therefore, constructing a reduced-order model to speed up the small-signal stability assessment becomes necessary. By extending the previous work of MG with P − ƒ/Q − V droop control, a reduced-order model of MG with P − ƒ/Q − V̇ droop control is investigated under mild assumptions. Such a simplified model will facilitate to compute the poles and zeros of the closed-loop systems and provide more physical insight to examine the relationship between dominant eigenvalues and each droop control gain. As the mathematical analysis of conventional P − ƒ/Q − V droop control provides the characteristic polynomials contributed by P − ƒ and Q − V droop controls, the P − ƒ/Q − V̇ droop control also provides a similar characteristic polynomials contributed by P − ƒ and Q − V̇ droop controls. These characteristic polynomials of the system helps MG operators for better tuning of each droop gain for stable operation of MG. A detailed study of actual plant model and the reduced-order plant model are investigated. Both simulation and experimental results are presented to validate the proposed method.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
An efficient method for small-signal stability assessment of P − ƒ/Q − V̇ droop control in an isolated micro-grid
An efficient method for small-signal stability assessment of P − ƒ/Q − V̇ droop control methods for multiple converters in an isolated micro-grid (MG) is proposed in this paper. A MG model described with arbitrary number of converters is explored first. If there are more number of converters in a chosen MG, only dominant eigenvalues related to droop control are of primary interest. Therefore, constructing a reduced-order model to speed up the small-signal stability assessment becomes necessary. By extending the previous work of MG with P − ƒ/Q − V droop control, a reduced-order model of MG with P − ƒ/Q − V̇ droop control is investigated under mild assumptions. Such a simplified model will facilitate to compute the poles and zeros of the closed-loop systems and provide more physical insight to examine the relationship between dominant eigenvalues and each droop control gain. As the mathematical analysis of conventional P − ƒ/Q − V droop control provides the characteristic polynomials contributed by P − ƒ and Q − V droop controls, the P − ƒ/Q − V̇ droop control also provides a similar characteristic polynomials contributed by P − ƒ and Q − V̇ droop controls. These characteristic polynomials of the system helps MG operators for better tuning of each droop gain for stable operation of MG. A detailed study of actual plant model and the reduced-order plant model are investigated. Both simulation and experimental results are presented to validate the proposed method.