Ki Hoon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ki Hoon Kim has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Dong Hwee Kim
Department of Physical Medicine and Rehabilitation, College of Medicine, Korea University, Ansan, Republic of Korea
23 shared publications - Byung Kyu Park
Department of Physical Medicine and Rehabilitation, Korea University College of Medicine, Seoul, Korea
10 shared publications - Hong Bum Park
Department of Physical Medicine and Rehabilitation, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, Korea
7 shared publications - Im Joo Rhyu
Department of Anatomy, Korea University College of Medicine, Seoul, Korea
6 shared publications - Dasom Kim
Department of Anatomy, Korea University College of Medicine, Seoul, Korea
4 shared publications - Chae Hyeon Ryou
Department of Physical Medicine and Rehabilitation, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, Korea
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8697
Assisted–Unassisted Walking Differential Across Three Configurations of a Powered Modular Gait Orthosis: Hip, Knee–Ankle–Foot, and Both Combined
Background/Objectives: Wearable powered gait orthoses are prescribed as assistive equipment, on the premise that torque at an impaired joint improves walking while the device is worn; the device also adds mass. Where a hip module and a knee–ankle–foot module can be worn together, the combined configuration places the mass of both on one limb, and whether its walking cost exceeds that of either module alone has not been tested under a common protocol. Methods: We analysed individual participant data from two previously published prospective studies, neither of which compared configurations. Forty-three adults with central neurological gait impairment, enrolled during 2024, were trained over six supervised sessions with a bilateral hip orthosis (HO, n = 13), a unilateral knee–ankle–foot orthosis (KAFO, n = 15), or both worn together (HKAFO, n = 15); the primary 6MWT analysis was performed on the complete-case subsample (n = 41, with HO n = 12, KAFO n = 14, HKAFO n = 15). The assisted–unassisted differential was computed per participant as (device-assisted − unassisted)/unassisted × 100; negative values indicate a shorter distance with the device. Results: No statistically significant baseline differences were detected across the three groups. The six-minute walk differential was larger for the HKAFO than for either single-region configuration at baseline (−24.9% versus −6.0% and −7.6%; Kruskal–Wallis p = 0.008) and after six sessions (−17.1% versus −5.9% and −4.3%; p = 0.012), whereas the two single-region configurations were indistinguishable at both assessments (p = 0.397 and 0.916). Short-distance gait speed did not differ between configurations (p = 0.290 and 0.457). Conclusions: The walking cost of the combined configuration was associated with a larger assisted–unassisted differential than that of either constituent module. We propose that this reflects the mass carried on a single limb rather than a shortfall in assistance, a reading these data support but cannot establish in the absence of kinematic or metabolic measurements. These findings should be regarded as hypothesis-generating and require prospective replication in a larger, adequately powered cohort.
- 1 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8697
Open AccessAssisted–Unassisted Walking Differential Across Three Configurations of a Powered Modular Gait Orthosis: Hip, Knee–Ankle–Foot, and Both Combined
Background/Objectives: Wearable powered gait orthoses are prescribed as assistive equipment, on the premise that torque at an impaired joint improves walking while the device is worn; the device also adds mass. Where a hip module and a knee–ankle–foot module can be worn together, the combined configuration places the mass of both on one limb, and whether its walking cost exceeds that of either module alone has not been tested under a common protocol. Methods: We analysed individual participant data from two previously published prospective studies, neither of which compared configurations. Forty-three adults with central neurological gait impairment, enrolled during 2024, were trained over six supervised sessions with a bilateral hip orthosis (HO, n = 13), a unilateral knee–ankle–foot orthosis (KAFO, n = 15), or both worn together (HKAFO, n = 15); the primary 6MWT analysis was performed on the complete-case subsample (n = 41, with HO n = 12, KAFO n = 14, HKAFO n = 15). The assisted–unassisted differential was computed per participant as (device-assisted − unassisted)/unassisted × 100; negative values indicate a shorter distance with the device. Results: No statistically significant baseline differences were detected across the three groups. The six-minute walk differential was larger for the HKAFO than for either single-region configuration at baseline (−24.9% versus −6.0% and −7.6%; Kruskal–Wallis p = 0.008) and after six sessions (−17.1% versus −5.9% and −4.3%; p = 0.012), whereas the two single-region configurations were indistinguishable at both assessments (p = 0.397 and 0.916). Short-distance gait speed did not differ between configurations (p = 0.290 and 0.457). Conclusions: The walking cost of the combined configuration was associated with a larger assisted–unassisted differential than that of either constituent module. We propose that this reflects the mass carried on a single limb rather than a shortfall in assistance, a reading these data support but cannot establish in the absence of kinematic or metabolic measurements. These findings should be regarded as hypothesis-generating and require prospective replication in a larger, adequately powered cohort.
- Open Access
- 31 August 2026
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 28 (2) , 17-24
Lewis-Sumner Syndrome Mimicking Idiopathic Brachial Plexopathy: A Case Report with Electrophysiological, Ultrasonographic, and Magnetic Resonance Imaging Findings
Multifocal acquired demyelinating sensory and motor neuropathy (MADSAM), also known as Lewis-Sumner syndrome, is a rare subtype of chronic inflammatory demyelinating polyradiculoneuropathy. We report a patient who initially presented with features suggestive of idiopathic brachial plexopathy and was ultimately diagnosed with MADSAM. A 43-year-old man presented with a 3-year history of progressive weakness in the right distal upper extremity and paresthesia in the fingers and forearm. Initial nerve conduction studies revealed characteristic demyelinating features, including definite conduction block in the right upper extremity. Ultrasonography showed swelling of the cervical roots of the brachial plexus, and magnetic resonance imaging (MRI) demonstrated increased signal intensity and multifocal swelling of the right C5–C8 roots and brachial plexus trunks. Additional nerve conduction studies of the lower extremities revealed conduction block and temporal dispersion of the right tibial nerve around the popliteal fossa. Right sciatic and tibial nerve swelling was also demonstrated on knee MRI. The patient was ultimately diagnosed with MADSAM and received oral corticosteroids and intravenous immunoglobulin treatment. This report emphasizes the need to integrate electrodiagnostic, ultrasonographic, and MRI findings when evaluating a patient with symptoms suggestive of brachial plexopathy, particularly because this rare inflammatory neuropathy is treatable.
- 31 August 2026
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 28 (2) , 17-24
Open AccessLewis-Sumner Syndrome Mimicking Idiopathic Brachial Plexopathy: A Case Report with Electrophysiological, Ultrasonographic, and Magnetic Resonance Imaging Findings
Multifocal acquired demyelinating sensory and motor neuropathy (MADSAM), also known as Lewis-Sumner syndrome, is a rare subtype of chronic inflammatory demyelinating polyradiculoneuropathy. We report a patient who initially presented with features suggestive of idiopathic brachial plexopathy and was ultimately diagnosed with MADSAM. A 43-year-old man presented with a 3-year history of progressive weakness in the right distal upper extremity and paresthesia in the fingers and forearm. Initial nerve conduction studies revealed characteristic demyelinating features, including definite conduction block in the right upper extremity. Ultrasonography showed swelling of the cervical roots of the brachial plexus, and magnetic resonance imaging (MRI) demonstrated increased signal intensity and multifocal swelling of the right C5–C8 roots and brachial plexus trunks. Additional nerve conduction studies of the lower extremities revealed conduction block and temporal dispersion of the right tibial nerve around the popliteal fossa. Right sciatic and tibial nerve swelling was also demonstrated on knee MRI. The patient was ultimately diagnosed with MADSAM and received oral corticosteroids and intravenous immunoglobulin treatment. This report emphasizes the need to integrate electrodiagnostic, ultrasonographic, and MRI findings when evaluating a patient with symptoms suggestive of brachial plexopathy, particularly because this rare inflammatory neuropathy is treatable.
- Open Access
- 7 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (10) , 3580
Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses
Background: Wearable powered gait orthoses offer a clinically flexible alternative to treadmill-based robotic systems, yet evidence on different device configurations matched to the site of neuromuscular impairment remains limited. Methods: In this multicenter prospective pilot study, 75 participants with neurological gait impairment were allocated to a hip orthosis (HO; n = 39) or a knee–ankle–foot orthosis (KAFO; n = 36) group based on clinical assessment of predominant gait pattern. Both groups completed six overground gait-training sessions over three weeks. Primary outcomes were the Six-Minute Walk Test (6MWT) and Ten-Meter Walk Test (10MWT), assessed without (WO) and with (WITH) the device. Secondary outcomes were the Berg Balance Scale (BBS), Timed Up and Go Test (TUG), and Dynamic Gait Index (DGI), all assessed without the device. Wilcoxon signed-rank tests were used for pre-to-post comparisons. Results: Both groups demonstrated significant improvements in primary walking outcomes, with consistent gains in unassisted (WO) 6MWT and 10MWT performance across groups and in device-assisted (WITH) 10MWT speed; the one exception was a small statistically significant but clinically negligible decrease in device-assisted 6MWT in the KAFO group (−4.1 m, below established MCID). In the KAFO group, BBS improved by a median of 5.5 points (43.5 to 49.0, p = 0.0005), TUG decreased by 5.1 s (p < 0.001), and DGI improved by 6.0 points (p = 0.002); all three changes exceeded published minimum detectable change thresholds. In the HO group, pre-to-post differences in BBS (+1.0), TUG (+0.8 s; an unfavorable direction), and DGI (−2.0; an unfavorable direction) were statistically detectable but small in absolute magnitude, fell at or below published thresholds for minimum detectable change, and should not be interpreted as clinically meaningful improvement. The WO-WITH performance gap in the KAFO group narrowed substantially after training, with 10MWT time no longer differing significantly between conditions at post-training (p = 0.116). Conclusions: Six sessions of gait pattern-matched powered gait orthosis training produced clinically meaningful within-group improvements in walking outcomes in both groups. In the KAFO group, balance and functional mobility outcomes also showed clinically meaningful improvements; in the HO group, balance and functional mobility outcomes showed only statistically detectable but clinically non-meaningful fluctuations around near-ceiling baseline scores. Walking benefits generalized to unassisted ambulation in both groups. These findings support the feasibility of an individualized orthosis prescription framework and provide a basis for future randomized controlled trials.
- 7 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (10) , 3580
Open AccessPattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses
Background: Wearable powered gait orthoses offer a clinically flexible alternative to treadmill-based robotic systems, yet evidence on different device configurations matched to the site of neuromuscular impairment remains limited. Methods: In this multicenter prospective pilot study, 75 participants with neurological gait impairment were allocated to a hip orthosis (HO; n = 39) or a knee–ankle–foot orthosis (KAFO; n = 36) group based on clinical assessment of predominant gait pattern. Both groups completed six overground gait-training sessions over three weeks. Primary outcomes were the Six-Minute Walk Test (6MWT) and Ten-Meter Walk Test (10MWT), assessed without (WO) and with (WITH) the device. Secondary outcomes were the Berg Balance Scale (BBS), Timed Up and Go Test (TUG), and Dynamic Gait Index (DGI), all assessed without the device. Wilcoxon signed-rank tests were used for pre-to-post comparisons. Results: Both groups demonstrated significant improvements in primary walking outcomes, with consistent gains in unassisted (WO) 6MWT and 10MWT performance across groups and in device-assisted (WITH) 10MWT speed; the one exception was a small statistically significant but clinically negligible decrease in device-assisted 6MWT in the KAFO group (−4.1 m, below established MCID). In the KAFO group, BBS improved by a median of 5.5 points (43.5 to 49.0, p = 0.0005), TUG decreased by 5.1 s (p < 0.001), and DGI improved by 6.0 points (p = 0.002); all three changes exceeded published minimum detectable change thresholds. In the HO group, pre-to-post differences in BBS (+1.0), TUG (+0.8 s; an unfavorable direction), and DGI (−2.0; an unfavorable direction) were statistically detectable but small in absolute magnitude, fell at or below published thresholds for minimum detectable change, and should not be interpreted as clinically meaningful improvement. The WO-WITH performance gap in the KAFO group narrowed substantially after training, with 10MWT time no longer differing significantly between conditions at post-training (p = 0.116). Conclusions: Six sessions of gait pattern-matched powered gait orthosis training produced clinically meaningful within-group improvements in walking outcomes in both groups. In the KAFO group, balance and functional mobility outcomes also showed clinically meaningful improvements; in the HO group, balance and functional mobility outcomes showed only statistically detectable but clinically non-meaningful fluctuations around near-ceiling baseline scores. Walking benefits generalized to unassisted ambulation in both groups. These findings support the feasibility of an individualized orthosis prescription framework and provide a basis for future randomized controlled trials.
- Open Access
- 31 December 2025
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 27 (3) , 47-54
Improving Diagnostic Accuracy for Diabetic Neuropathy: Implementation and Evaluation of an Electrodiagnostic Protocol
Objective: Diabetic distal symmetric polyneuropathy (DSPN) is a common complication of type 2 diabetes mellitus (T2DM) that requires accurate and reliable diagnostic approaches. Existing diagnostic criteria lack sufficient specificity, creating the need for the development of a novel electrodiagnostic protocol. This study aimed to validate the clinical utility of this protocol.Methods: A retrospective analysis was performed in 220 patients with T2DM who were referred for DSPN screening. Nerve conduction studies (NCS) parameters, including compound muscle action potential (CMAP) of the tibial and peroneal nerves, sensory nerve action potential (SNAP) of the sural nerve, and F-waves, were systematically reviewed. Electrodiagnostic findings were correlated with neuropathic symptoms, duration of diabetes, and glycated hemoglobin levels.Results: Based on NCS findings, patients were stratified into normal, early, mild, moderate, and severe DSPN groups. Significant associations were identified between DSPN severity, symptom burden, and specific electrophysiological parameters, particularly tibial CMAP and sural SNAP amplitudes. The protocol enabled structured disease categorization and demonstrated strong diagnostic applicability across the full spectrum of DSPN severity.Conclusion: The proposed electrodiagnostic protocol provides a systematic and efficient approach for diagnosing DSPN in patients with T2DM. It highlights the diagnostic relevance of selected NCS parameters in relation to clinical symptomatology. Further prospective validation in larger and more diverse populations is warranted.
- 31 December 2025
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 27 (3) , 47-54
Open AccessImproving Diagnostic Accuracy for Diabetic Neuropathy: Implementation and Evaluation of an Electrodiagnostic Protocol
Objective: Diabetic distal symmetric polyneuropathy (DSPN) is a common complication of type 2 diabetes mellitus (T2DM) that requires accurate and reliable diagnostic approaches. Existing diagnostic criteria lack sufficient specificity, creating the need for the development of a novel electrodiagnostic protocol. This study aimed to validate the clinical utility of this protocol.Methods: A retrospective analysis was performed in 220 patients with T2DM who were referred for DSPN screening. Nerve conduction studies (NCS) parameters, including compound muscle action potential (CMAP) of the tibial and peroneal nerves, sensory nerve action potential (SNAP) of the sural nerve, and F-waves, were systematically reviewed. Electrodiagnostic findings were correlated with neuropathic symptoms, duration of diabetes, and glycated hemoglobin levels.Results: Based on NCS findings, patients were stratified into normal, early, mild, moderate, and severe DSPN groups. Significant associations were identified between DSPN severity, symptom burden, and specific electrophysiological parameters, particularly tibial CMAP and sural SNAP amplitudes. The protocol enabled structured disease categorization and demonstrated strong diagnostic applicability across the full spectrum of DSPN severity.Conclusion: The proposed electrodiagnostic protocol provides a systematic and efficient approach for diagnosing DSPN in patients with T2DM. It highlights the diagnostic relevance of selected NCS parameters in relation to clinical symptomatology. Further prospective validation in larger and more diverse populations is warranted.
- Open Access
- 31 December 2023
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 25 (3) , 111-115
Ultrasonographic Evaluation of the Needle Insertion Site for the Flexor Pollicis Longus Using the Flexor Carpi Radialis Tendon
Objective: In needle electromyography (EMG), the flexor pollicis longus (FPL) muscle is important for diagnosing anterior interosseous nerve syndrome and proximal median neuropathy. However, different methods have been proposed for needle EMG placement in the FPL. This study aimed to determine the optimal needle insertion position for the examination of the FPL via needle EMG under ultrasound guidance.Methods: This study included 15 men (30 upper limbs) and 13 women (26 upper limbs). At the mid-forearm level, the angles between the vertical line descending from the radial side of the flexor carpi radialis (FCR) tendon and radial artery (angle A), flexor digitorum profundus 1 (angle B), and median nerve (MN) (angle C) were measured. Angle D was defined as the average of angles A and B.Results: The median value of angle D was –19.8°. The probability of radial artery injury at an angle D of 10° was 10.7%. The likelihood of MN injury was 7.1%.Conclusion: Needle insertion through the FCR tendon is relatively safe, although the risk of neurovascular injury remains. Therefore, an ultrasound examination could be considered as an assistive method.
- 31 December 2023
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 25 (3) , 111-115
Open AccessUltrasonographic Evaluation of the Needle Insertion Site for the Flexor Pollicis Longus Using the Flexor Carpi Radialis Tendon
Objective: In needle electromyography (EMG), the flexor pollicis longus (FPL) muscle is important for diagnosing anterior interosseous nerve syndrome and proximal median neuropathy. However, different methods have been proposed for needle EMG placement in the FPL. This study aimed to determine the optimal needle insertion position for the examination of the FPL via needle EMG under ultrasound guidance.Methods: This study included 15 men (30 upper limbs) and 13 women (26 upper limbs). At the mid-forearm level, the angles between the vertical line descending from the radial side of the flexor carpi radialis (FCR) tendon and radial artery (angle A), flexor digitorum profundus 1 (angle B), and median nerve (MN) (angle C) were measured. Angle D was defined as the average of angles A and B.Results: The median value of angle D was –19.8°. The probability of radial artery injury at an angle D of 10° was 10.7%. The likelihood of MN injury was 7.1%.Conclusion: Needle insertion through the FCR tendon is relatively safe, although the risk of neurovascular injury remains. Therefore, an ultrasound examination could be considered as an assistive method.
- Open Access
- 31 December 2023
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 25 (3) , 125-128
Electrophysiological and Ultrasonographic Evaluation of Palmar Digital Nerve Injury in Distal Finger
Electrophysiological evaluation of distal lesions in the palmar digital branch of the median nerve presents a significant challenge. We present a case of lateral palmar digital neuropathy of the median nerve, which was confirmed through clinical, electrophysiological, and ultrasonographic assessments. A 54-year-old woman was referred to our electrophysiology laboratory for persistent numbness and a tingling sensation on the radial side of the distal phalanx of her left second finger. She had a laceration injury on the middle phalanx of the second finger and underwent neurorrhaphy of the lateral branch of the palmar digital nerve 8 months ago. Sensory nerve conduction studies, both antidromic and orthodromic, showed low amplitude responses for the lateral branch of the palmar digital nerve. Ultrasonography revealed swelling of this nerve branch within the middle phalanx of the second finger. When patients report sensory symptoms in a specific area, it is important to evaluate for potential cutaneous nerve injuries using electrophysiological studies. Additionally, high-resolution ultrasonography is a valuable tool for investigating small cutaneous nerve lesions, even in the distal finger.
- 31 December 2023
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 25 (3) , 125-128
Open AccessElectrophysiological and Ultrasonographic Evaluation of Palmar Digital Nerve Injury in Distal Finger
Electrophysiological evaluation of distal lesions in the palmar digital branch of the median nerve presents a significant challenge. We present a case of lateral palmar digital neuropathy of the median nerve, which was confirmed through clinical, electrophysiological, and ultrasonographic assessments. A 54-year-old woman was referred to our electrophysiology laboratory for persistent numbness and a tingling sensation on the radial side of the distal phalanx of her left second finger. She had a laceration injury on the middle phalanx of the second finger and underwent neurorrhaphy of the lateral branch of the palmar digital nerve 8 months ago. Sensory nerve conduction studies, both antidromic and orthodromic, showed low amplitude responses for the lateral branch of the palmar digital nerve. Ultrasonography revealed swelling of this nerve branch within the middle phalanx of the second finger. When patients report sensory symptoms in a specific area, it is important to evaluate for potential cutaneous nerve injuries using electrophysiological studies. Additionally, high-resolution ultrasonography is a valuable tool for investigating small cutaneous nerve lesions, even in the distal finger.
- Open Access
- 31 August 2023
- Published by Korean Academy of Rehabilitation Medicine in Annals of Rehabilitation Medicine
- Vol. 47 (4) , 231-233
Diabetic Distal Symmetric Sensorimotor Polyneuropathy: A Proposal of New Electrodiagnostic Evaluation
- 31 August 2023
- Published by Korean Academy of Rehabilitation Medicine in Annals of Rehabilitation Medicine
- Vol. 47 (4) , 231-233
Open AccessDiabetic Distal Symmetric Sensorimotor Polyneuropathy: A Proposal of New Electrodiagnostic Evaluation
- Open Access
- 26 April 2023
- Published by XMLink in Journal of Clinical Neurology
- Vol. 19 (4) , 376-380
Ultrasonographic Evaluation of the Optimal Needle Position in the Supinator Muscle
Park HB, et al. J Clin Neurol. 2023 Apr;19:e35. https://doi.org/10.3988/jcn.2022.0206
- 26 April 2023
- Published by XMLink in Journal of Clinical Neurology
- Vol. 19 (4) , 376-380
Open AccessUltrasonographic Evaluation of the Optimal Needle Position in the Supinator Muscle
Park HB, et al. J Clin Neurol. 2023 Apr;19:e35. https://doi.org/10.3988/jcn.2022.0206
- Open Access
- 31 October 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (11) , 2177
A Proposed Safe Electromyographic Needle Insertion Technique for the Flexor Pollicis Longus Muscle Using Arterial Pulse Palpation: Preliminary Study with Ultrasonography
Electromyographic needle access to the flexor pollicis longus (FPL) is challenging because of the risk of injuries to the superficial radial nerve (SRN) or radial artery (RA), which run close to the FPL. This study aimed to investigate the safe electromyographic needle insertion point of the FPL using a newly proposed RA pulse palpation method. Fifty forearms of 25 healthy individuals were studied. At the junction of the middle and distal third of the forearm, an RA pulse was palpated, and 5 mm lateral to the pulse was determined as the preliminary needle insertion point. The distance from the vertical virtual needle pathway to the RA and SRN was measured using ultrasonography. In ultrasonography, the distances from the needle pathway to the RA and the SRN were 3.4 ± 0.8 (range, 2.1–6.0) and 5.9 ± 1.8 (range, 2.4–9.4) mm, respectively. The depth of the FPL muscle was 8.4 ± 1.7 mm. Electromyographic needle insertion into the FPL can be safely performed using the RA palpation method. The needle insertion point is 5 mm lateral to the RA pulse at the level between the middle and distal third of the forearm.
- 31 October 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (11) , 2177
Open AccessA Proposed Safe Electromyographic Needle Insertion Technique for the Flexor Pollicis Longus Muscle Using Arterial Pulse Palpation: Preliminary Study with Ultrasonography
Electromyographic needle access to the flexor pollicis longus (FPL) is challenging because of the risk of injuries to the superficial radial nerve (SRN) or radial artery (RA), which run close to the FPL. This study aimed to investigate the safe electromyographic needle insertion point of the FPL using a newly proposed RA pulse palpation method. Fifty forearms of 25 healthy individuals were studied. At the junction of the middle and distal third of the forearm, an RA pulse was palpated, and 5 mm lateral to the pulse was determined as the preliminary needle insertion point. The distance from the vertical virtual needle pathway to the RA and SRN was measured using ultrasonography. In ultrasonography, the distances from the needle pathway to the RA and the SRN were 3.4 ± 0.8 (range, 2.1–6.0) and 5.9 ± 1.8 (range, 2.4–9.4) mm, respectively. The depth of the FPL muscle was 8.4 ± 1.7 mm. Electromyographic needle insertion into the FPL can be safely performed using the RA palpation method. The needle insertion point is 5 mm lateral to the RA pulse at the level between the middle and distal third of the forearm.
- Open Access
- 31 August 2022
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 24 (2) , 42-45
Neoplastic Lumbosacral Plexopathy in Untreated Cervical Cancer: A Case Report
In this report, we present the case of a patient with cervical adenocarcinoma with progressive right lower-extremity pain and weakness. Electromyography of the lower extremities and subsequent ultrasonographic imaging complementarily demonstrated findings considered suspicious for the perineural spread of malignancy to the lumbosacral plexus and sciatic nerve. This possibility was confirmed by magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning. This case report suggests that in addition to MRI and FDG PET/CT scans, electromyography and ultrasonographic imaging are valuable modalities for the diagnosis of perineural malignancy.
- 31 August 2022
- Published by Korean Association of EMG Electrodiagnostic Medicine in Journal of Electrodiagnosis and Neuromuscular Diseases
- Vol. 24 (2) , 42-45
Open AccessNeoplastic Lumbosacral Plexopathy in Untreated Cervical Cancer: A Case Report
In this report, we present the case of a patient with cervical adenocarcinoma with progressive right lower-extremity pain and weakness. Electromyography of the lower extremities and subsequent ultrasonographic imaging complementarily demonstrated findings considered suspicious for the perineural spread of malignancy to the lumbosacral plexus and sciatic nerve. This possibility was confirmed by magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning. This case report suggests that in addition to MRI and FDG PET/CT scans, electromyography and ultrasonographic imaging are valuable modalities for the diagnosis of perineural malignancy.