Ulrike Nöth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ulrike Nöth has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Ralf Deichmann
Brain Imaging Center (BIC) Goethe University Frankfurt Frankfurt am Main Germany
7 shared publications- Ralf Deichmann
Goethe University Frankfurt Cooperative Brain Imaging Center – CoBIC Frankfurt am Main Germany
7 shared publications - Elke Hattingen
Institute for Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, 60528, Germany
5 shared publications - Axel Haase
Technische Universität München, Munich, Germany
3 shared publications C. Schwarzbauer
Institut für Luft- und Raumfahrtmedizin, Deutsche Forschungsanstalt für Luft- und Raumfahrt, Köln, Germany
2 shared publicationsH. Adolf
Physikalisches Institut der Universität Würzburg, Germany
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by Oxford University Press (OUP) in Neuro-Oncology Advances
- Vol. 6 (1) , vdae117
A fast protocol for multicenter and multiparametric quantitative MRI studies in brain tumor patients using vendor sequences
Background: Multiparametric quantitative MRI (mp-qMRI) provides noninvasive, quantitative measurements sensitive to a variety of tissue properties. In brain tumors (BTs), longitudinal relaxation time (T1), effective transverse relaxation time (T2*), transverse relaxation time (T2), water content (H2O), and quantitative susceptibility (χ) give valuable insights into the microenvironment. To generate large multicenter datasets, protocols need to be short and implementable on any scanner. The goal of this work was to develop and validate an 8-min, 3T mp-qMRI protocol for BT patients solely using generalized pulse sequences (mGRE and EPI). Methods: A protocol was developed and tested on a multicompartment phantom, 5 healthy subjects (mean age: 31.64 years), and 4 BT patients (mean age:39.5 years). Phantom and healthy subject longitudinal relaxation time (T1) maps were compared to those obtained using 2 reference methods. The 5 healthy subjects were scanned on 3T MRI scanners at 2 different sites and the reproducibility between scanners was assessed by computing Coefficients of Variance (COV) maps, performing Bland–Altman analysis and t-tests. Clinical feasibility was tested on 4 BT patients. Results: T1 values obtained using the proposed mp-qMRI protocol agree with those obtained using the reference methods in volunteers (mean error = 8.94 ms). The qMRI maps (T1, T2*, H2O, and χ) of the volunteers showed good reproducibility between scanners with no significant differences for mean WM and GM qMRI values. WM and GM mean qMRI values agreed well with literature values. H2O gave the lowest COV and χ maps the highest. Conclusion: The proposed vendor sequence-based 3T mp-qMRI protocol gives interpolated, high resolution (1 mm isotropic) T1, T2*, H2O, and χ maps in 8 min of acquisition.
- 1 January 2024
- Published by Oxford University Press (OUP) in Neuro-Oncology Advances
- Vol. 6 (1) , vdae117
Open AccessA fast protocol for multicenter and multiparametric quantitative MRI studies in brain tumor patients using vendor sequences
Background: Multiparametric quantitative MRI (mp-qMRI) provides noninvasive, quantitative measurements sensitive to a variety of tissue properties. In brain tumors (BTs), longitudinal relaxation time (T1), effective transverse relaxation time (T2*), transverse relaxation time (T2), water content (H2O), and quantitative susceptibility (χ) give valuable insights into the microenvironment. To generate large multicenter datasets, protocols need to be short and implementable on any scanner. The goal of this work was to develop and validate an 8-min, 3T mp-qMRI protocol for BT patients solely using generalized pulse sequences (mGRE and EPI). Methods: A protocol was developed and tested on a multicompartment phantom, 5 healthy subjects (mean age: 31.64 years), and 4 BT patients (mean age:39.5 years). Phantom and healthy subject longitudinal relaxation time (T1) maps were compared to those obtained using 2 reference methods. The 5 healthy subjects were scanned on 3T MRI scanners at 2 different sites and the reproducibility between scanners was assessed by computing Coefficients of Variance (COV) maps, performing Bland–Altman analysis and t-tests. Clinical feasibility was tested on 4 BT patients. Results: T1 values obtained using the proposed mp-qMRI protocol agree with those obtained using the reference methods in volunteers (mean error = 8.94 ms). The qMRI maps (T1, T2*, H2O, and χ) of the volunteers showed good reproducibility between scanners with no significant differences for mean WM and GM qMRI values. WM and GM mean qMRI values agreed well with literature values. H2O gave the lowest COV and χ maps the highest. Conclusion: The proposed vendor sequence-based 3T mp-qMRI protocol gives interpolated, high resolution (1 mm isotropic) T1, T2*, H2O, and χ maps in 8 min of acquisition.
- Open Access
- 13 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 103-116
B1 mapping using an EPI‐based double angle approach: A practical guide for correcting slice profile and B0 distortion effects
Purpose: Aim of this study was to develop a reliable B1 mapping method for brain imaging based on vendor MR sequences available on clinical scanners. Correction procedures for B0 distortions and slice profile imperfections are proposed, together with a phantom experiment for deriving the approximate time‐bandwidth‐product (TBP) of the excitation pulse, which is usually not known for vendor sequences.Methods: The double angle method was used, acquiring two gradient echo echo‐planar imaging data sets with different excitation angles. A correction factor C (B1, TBP, B0) was derived from simulations for converting double angle method signal quotients into bias‐free B1 maps. In vitro and in vivo tests compare results with reference B1 maps based on an established in‐house sequence.Results: The simulation shows that C has a negligible B1 dependence, allowing for a polynomial approximation of C (TBP, B0). Signal quotients measured in a phantom experiment with known TBP reconfirm the simulation results. In vitro and in vivo B1 maps based on the proposed method, assuming TBP = 5.8 as derived from a phantom experiment, match closely the reference B1 maps. Analysis without B0 correction shows marked deviations in areas of distorted B0, highlighting the importance of this correction.Conclusion: Double angle method‐based B1 mapping was set up for vendor gradient echo‐echo‐planar imaging sequences, using a correction procedure for slice profile imperfections and B0 distortions. This will help to set up quantitative MRI studies on clinical scanners with release sequences, as the method does not require knowledge of the exact RF‐pulse profiles or the use of in‐house sequences.
- 13 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 103-116
Open AccessB1 mapping using an EPI‐based double angle approach: A practical guide for correcting slice profile and B0 distortion effects
Purpose: Aim of this study was to develop a reliable B1 mapping method for brain imaging based on vendor MR sequences available on clinical scanners. Correction procedures for B0 distortions and slice profile imperfections are proposed, together with a phantom experiment for deriving the approximate time‐bandwidth‐product (TBP) of the excitation pulse, which is usually not known for vendor sequences.Methods: The double angle method was used, acquiring two gradient echo echo‐planar imaging data sets with different excitation angles. A correction factor C (B1, TBP, B0) was derived from simulations for converting double angle method signal quotients into bias‐free B1 maps. In vitro and in vivo tests compare results with reference B1 maps based on an established in‐house sequence.Results: The simulation shows that C has a negligible B1 dependence, allowing for a polynomial approximation of C (TBP, B0). Signal quotients measured in a phantom experiment with known TBP reconfirm the simulation results. In vitro and in vivo B1 maps based on the proposed method, assuming TBP = 5.8 as derived from a phantom experiment, match closely the reference B1 maps. Analysis without B0 correction shows marked deviations in areas of distorted B0, highlighting the importance of this correction.Conclusion: Double angle method‐based B1 mapping was set up for vendor gradient echo‐echo‐planar imaging sequences, using a correction procedure for slice profile imperfections and B0 distortions. This will help to set up quantitative MRI studies on clinical scanners with release sequences, as the method does not require knowledge of the exact RF‐pulse profiles or the use of in‐house sequences.
- 1 January 2022
- Published by Springer Nature
- p. 49-77
The Basics of Functional Magnetic Resonance Imaging
- 1 January 2022
- Published by Springer Nature
- p. 49-77
The Basics of Functional Magnetic Resonance Imaging
- Open Access
Matching Quantitative MRI Parameters with Histological Features of Treatment-Naïve IDH Wild-Type Glioma
Quantitative MRI allows to probe tissue properties by measuring relaxation times and may thus detect subtle changes in tissue composition. In this work we analyzed different relaxation times (T1, T2, T2* and T2′) and histological features in 321 samples that were acquired from 25 patients with newly diagnosed IDH wild-type glioma. Quantitative relaxation times before intravenous application of gadolinium-based contrast agent (GBCA), T1 relaxation time after GBCA as well as the relative difference between T1 relaxation times pre-to-post GBCA (T1rel) were compared with histopathologic features such as the presence of tumor cells, cell and vessel density, endogenous markers for hypoxia and cell proliferation. Image-guided stereotactic biopsy allowed for the attribution of each tissue specimen to its corresponding position in the respective relaxation time map. Compared to normal tissue, T1 and T2 relaxation times and T1rel were prolonged in samples containing tumor cells. The presence of vascular proliferates was associated with higher T1rel values. Immunopositivity for lactate dehydrogenase A (LDHA) involved slightly longer T1 relaxation times. However, low T2′ values, suggesting high amounts of deoxyhemoglobin, were found in samples with elevated vessel densities, but not in samples with increased immunopositivity for LDHA. Taken together, some of our observations were consistent with previous findings but the correlation of quantitative MRI and histologic parameters did not confirm all our pathophysiology-based assumptions.
Open AccessMatching Quantitative MRI Parameters with Histological Features of Treatment-Naïve IDH Wild-Type Glioma
Quantitative MRI allows to probe tissue properties by measuring relaxation times and may thus detect subtle changes in tissue composition. In this work we analyzed different relaxation times (T1, T2, T2* and T2′) and histological features in 321 samples that were acquired from 25 patients with newly diagnosed IDH wild-type glioma. Quantitative relaxation times before intravenous application of gadolinium-based contrast agent (GBCA), T1 relaxation time after GBCA as well as the relative difference between T1 relaxation times pre-to-post GBCA (T1rel) were compared with histopathologic features such as the presence of tumor cells, cell and vessel density, endogenous markers for hypoxia and cell proliferation. Image-guided stereotactic biopsy allowed for the attribution of each tissue specimen to its corresponding position in the respective relaxation time map. Compared to normal tissue, T1 and T2 relaxation times and T1rel were prolonged in samples containing tumor cells. The presence of vascular proliferates was associated with higher T1rel values. Immunopositivity for lactate dehydrogenase A (LDHA) involved slightly longer T1 relaxation times. However, low T2′ values, suggesting high amounts of deoxyhemoglobin, were found in samples with elevated vessel densities, but not in samples with increased immunopositivity for LDHA. Taken together, some of our observations were consistent with previous findings but the correlation of quantitative MRI and histologic parameters did not confirm all our pathophysiology-based assumptions.
- Open Access
- 4 September 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (2) , 883-896
A novel sequence to improve auditory functional MRI with variable silent delays
Purpose Auditory functional MRI (fMRI) often uses silent inter‐volume delays for stimulus presentation. However, maintaining the steady‐state of the magnetization usually requires constant delays. Here, a novel acquisition scheme dubbed “pre‐Saturated EPI using Multiple delays in Steady‐state” (SEPIMS) is proposed, using spin saturation at a fixed delay before each volume to maintain steady‐state conditions, independent of previous spin history. This concept allows for variable inter‐volume delays and thus for flexible stimulus design in auditory fMRI. The purpose was to compare the signal stability of SEPIMS and conventional sparse EPI (CS‐EPI). Methods The saturation module comprises two non‐selective adiabatic saturation pulses. The efficiency of the saturation and its effect on the SEPIMS signal stability is tested in vitro and in vivo. Results Data show that SEPIMS yields the same signal stability as CS‐EPI, even for extreme variations between inter‐volume delay durations. However, dual saturation pulses are required to achieve sufficiently high saturation efficiency in compartments with long T1 values. Importantly, spoiler gradient pulses after the EPI readout have to be optimized to avoid eddy‐current‐induced image distortions. Conclusion The proposed SEPIMS sequence maintains high signal stability in the presence of variable inter‐volume durations, thus allowing for flexible stimulus design.
- 4 September 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (2) , 883-896
Open AccessA novel sequence to improve auditory functional MRI with variable silent delays
Purpose Auditory functional MRI (fMRI) often uses silent inter‐volume delays for stimulus presentation. However, maintaining the steady‐state of the magnetization usually requires constant delays. Here, a novel acquisition scheme dubbed “pre‐Saturated EPI using Multiple delays in Steady‐state” (SEPIMS) is proposed, using spin saturation at a fixed delay before each volume to maintain steady‐state conditions, independent of previous spin history. This concept allows for variable inter‐volume delays and thus for flexible stimulus design in auditory fMRI. The purpose was to compare the signal stability of SEPIMS and conventional sparse EPI (CS‐EPI). Methods The saturation module comprises two non‐selective adiabatic saturation pulses. The efficiency of the saturation and its effect on the SEPIMS signal stability is tested in vitro and in vivo. Results Data show that SEPIMS yields the same signal stability as CS‐EPI, even for extreme variations between inter‐volume delay durations. However, dual saturation pulses are required to achieve sufficiently high saturation efficiency in compartments with long T1 values. Importantly, spoiler gradient pulses after the EPI readout have to be optimized to avoid eddy‐current‐induced image distortions. Conclusion The proposed SEPIMS sequence maintains high signal stability in the presence of variable inter‐volume durations, thus allowing for flexible stimulus design.
- Open Access
- 26 December 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (3) , e4242
Quantitative T1 mapping indicates tumor infiltration beyond the enhancing part of glioblastomas
The aim of this study was to evaluate whether maps of quantitative T1 (qT1) differences induced by a gadolinium‐based contrast agent (CA) are better suited than conventional T1‐weighted (T1w) MR images for detecting infiltration inside and beyond the peritumoral edema of glioblastomas. Conventional T1w images and qT1 maps were obtained before and after gadolinium‐based CA administration in 33 patients with glioblastoma before therapy. The following data were calculated: (i) absolute qT1‐difference maps (qT1 pre‐CA ‐ qT1 post‐CA), (ii) relative qT1‐difference maps, (iii) absolute and (iv) relative differences of conventional T1w images acquired pre‐ and post‐CA. The values of these four datasets were compared in four different regions: (a) the enhancing tumor, (b) the peritumoral edema, (c) a 5 mm zone around the pathology (defined as the sum of regions a and b), and (d) the contralateral normal appearing brain tissue. Additionally, absolute qT1‐difference maps (displayed with linear gray scaling) were visually compared with respective conventional difference images. The enhancing tumor was visible both in the difference of conventional pre‐ and post‐CA T1w images and in the absolute qT1‐difference maps, whereas only the latter showed elevated values in the peritumoral edema and in some cases even beyond. Mean absolute qT1‐difference values were significantly higher (P < 0.01) in the enhancing tumor (838 ± 210 ms), the peritumoral edema (123 ± 74 ms) and in the 5 mm zone around the pathology (81 ± 31 ms) than in normal appearing tissue (32 ± 35 ms). In summary, absolute qT1‐difference maps—in contrast to the difference of T1w images—of untreated glioblastomas appear to be able to visualize CA leakage, and thus might indicate tumor cell infiltration in the edema region and beyond. Therefore, the absolute qT1‐difference maps are potentially useful for treatment planning.
- 26 December 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (3) , e4242
Open AccessQuantitative T1 mapping indicates tumor infiltration beyond the enhancing part of glioblastomas
The aim of this study was to evaluate whether maps of quantitative T1 (qT1) differences induced by a gadolinium‐based contrast agent (CA) are better suited than conventional T1‐weighted (T1w) MR images for detecting infiltration inside and beyond the peritumoral edema of glioblastomas. Conventional T1w images and qT1 maps were obtained before and after gadolinium‐based CA administration in 33 patients with glioblastoma before therapy. The following data were calculated: (i) absolute qT1‐difference maps (qT1 pre‐CA ‐ qT1 post‐CA), (ii) relative qT1‐difference maps, (iii) absolute and (iv) relative differences of conventional T1w images acquired pre‐ and post‐CA. The values of these four datasets were compared in four different regions: (a) the enhancing tumor, (b) the peritumoral edema, (c) a 5 mm zone around the pathology (defined as the sum of regions a and b), and (d) the contralateral normal appearing brain tissue. Additionally, absolute qT1‐difference maps (displayed with linear gray scaling) were visually compared with respective conventional difference images. The enhancing tumor was visible both in the difference of conventional pre‐ and post‐CA T1w images and in the absolute qT1‐difference maps, whereas only the latter showed elevated values in the peritumoral edema and in some cases even beyond. Mean absolute qT1‐difference values were significantly higher (P < 0.01) in the enhancing tumor (838 ± 210 ms), the peritumoral edema (123 ± 74 ms) and in the 5 mm zone around the pathology (81 ± 31 ms) than in normal appearing tissue (32 ± 35 ms). In summary, absolute qT1‐difference maps—in contrast to the difference of T1w images—of untreated glioblastomas appear to be able to visualize CA leakage, and thus might indicate tumor cell infiltration in the edema region and beyond. Therefore, the absolute qT1‐difference maps are potentially useful for treatment planning.
- Open Access
- 3 December 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (2) , e4203
Detection of cortical malformations using enhanced synthetic contrast images derived from quantitative T1 maps
The detection of cortical malformations in conventional MR images can be challenging. Prominent examples are focal cortical dysplasias (FCD), the most common cause of drug‐resistant focal epilepsy. The two main MRI hallmarks of cortical malformations are increased cortical thickness and blurring of the gray (GM) and white matter (WM) junction. The purpose of this study was to derive synthetic anatomies from quantitative T1 maps for the improved display of the above imaging characteristics in individual patients.On the basis of a T1 map, a mask comprising pixels with T1 values characteristic for GM is created from which the local cortical extent (CE) is determined. The local smoothness (SM) of the GM‐WM junctions is derived from the T1 gradient. For display of cortical malformations, the resulting CE and SM maps serve to enhance local intensities in synthetic double inversion recovery (DIR) images calculated from the T1 map.The resulting CE‐ and/or SM‐enhanced DIR images appear hyperintense at the site of cortical malformations, thus facilitating FCD detection in epilepsy patients. However, false positives may arise in areas with naturally elevated CE and/or SM, such as large GM structures and perivascular spaces.In summary, the proposed method facilitates the detection of cortical abnormalities such as cortical thickening and blurring of the GM‐WM junction which are typical FCD markers. Still, subject motion artifacts, perivascular spaces, and large normal GM structures may also yield signal hyperintensity in the enhanced synthetic DIR images, requiring careful comparison with clinical MR images by an experienced neuroradiologist to exclude false positives.
- 3 December 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (2) , e4203
Open AccessDetection of cortical malformations using enhanced synthetic contrast images derived from quantitative T1 maps
The detection of cortical malformations in conventional MR images can be challenging. Prominent examples are focal cortical dysplasias (FCD), the most common cause of drug‐resistant focal epilepsy. The two main MRI hallmarks of cortical malformations are increased cortical thickness and blurring of the gray (GM) and white matter (WM) junction. The purpose of this study was to derive synthetic anatomies from quantitative T1 maps for the improved display of the above imaging characteristics in individual patients.On the basis of a T1 map, a mask comprising pixels with T1 values characteristic for GM is created from which the local cortical extent (CE) is determined. The local smoothness (SM) of the GM‐WM junctions is derived from the T1 gradient. For display of cortical malformations, the resulting CE and SM maps serve to enhance local intensities in synthetic double inversion recovery (DIR) images calculated from the T1 map.The resulting CE‐ and/or SM‐enhanced DIR images appear hyperintense at the site of cortical malformations, thus facilitating FCD detection in epilepsy patients. However, false positives may arise in areas with naturally elevated CE and/or SM, such as large GM structures and perivascular spaces.In summary, the proposed method facilitates the detection of cortical abnormalities such as cortical thickening and blurring of the GM‐WM junction which are typical FCD markers. Still, subject motion artifacts, perivascular spaces, and large normal GM structures may also yield signal hyperintensity in the enhanced synthetic DIR images, requiring careful comparison with clinical MR images by an experienced neuroradiologist to exclude false positives.
- Open Access
- 1 December 2019
- Published by Elsevier in IBRO Reports
- Vol. 7, 117-128
Delta-9-tetrahydrocannabinol reduces the performance in sensory delayed discrimination tasks. A pharmacological-fMRI study in healthy volunteers
- 1 December 2019
- Published by Elsevier in IBRO Reports
- Vol. 7, 117-128
Open AccessDelta-9-tetrahydrocannabinol reduces the performance in sensory delayed discrimination tasks. A pharmacological-fMRI study in healthy volunteers
- Open Access
- 10 May 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (7) , 1273-1279
Extent of Microstructural Tissue Damage Correlates with Hemodynamic Failure in High-Grade Carotid Occlusive Disease: An MRI Study Using Quantitative T2 and DSC Perfusion
BACKGROUND AND PURPOSE: Chronic hemodynamic impairment in high-grade carotid occlusive disease is thought to cause microstructural abnormalities that might be subclinical or lead to subtle symptoms including cognitive impairment. Quantitative MR imaging allows assessing pathologic structural changes beyond macroscopically visible tissue damage. In this study, high-resolution quantitative T2 mapping combined with DSC-based PWI was used to investigate quantitative T2 changes as a potential marker of microstructural damage in relation to hemodynamic impairment in patients with unilateral high-grade carotid occlusive disease. MATERIALS AND METHODS: Eighteen patients with unilateral high-grade ICA or MCA stenosis/occlusion were included in the study. T2 values and deconvolved perfusion parameters, including relative CBF, relative CBV, and the relative CBF/relative CBV ratio as a potential indicator of local cerebral perfusion pressure, were determined within areas with delayed TTP and compared with values from contralateral unaffected areas after segmentation of normal-appearing hypoperfused WM and cortical regions. Hemispheric asymmetry indices were calculated for all parameters. RESULTS: Quantitative T2 was significantly prolonged (P < .01) in hypoperfused tissue and correlated significantly (P < .01) with TTP delay and relative CBF/relative CBV reduction in WM. Significant correlations (P < .001) between TTP delay and the relative CBF/relative CBV ratio were found both in WM and in cortical areas. CONCLUSIONS: Quantitative T2 can be used as a marker of microstructural tissue damage even in normal-appearing GM and WM within a vascular territory affected by high-grade carotid occlusive disease. Furthermore, the extent of damage correlates with the degree of hemodynamic failure measured by DSC perfusion parameters.
- 10 May 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (7) , 1273-1279
Open AccessExtent of Microstructural Tissue Damage Correlates with Hemodynamic Failure in High-Grade Carotid Occlusive Disease: An MRI Study Using Quantitative T2 and DSC Perfusion
BACKGROUND AND PURPOSE: Chronic hemodynamic impairment in high-grade carotid occlusive disease is thought to cause microstructural abnormalities that might be subclinical or lead to subtle symptoms including cognitive impairment. Quantitative MR imaging allows assessing pathologic structural changes beyond macroscopically visible tissue damage. In this study, high-resolution quantitative T2 mapping combined with DSC-based PWI was used to investigate quantitative T2 changes as a potential marker of microstructural damage in relation to hemodynamic impairment in patients with unilateral high-grade carotid occlusive disease. MATERIALS AND METHODS: Eighteen patients with unilateral high-grade ICA or MCA stenosis/occlusion were included in the study. T2 values and deconvolved perfusion parameters, including relative CBF, relative CBV, and the relative CBF/relative CBV ratio as a potential indicator of local cerebral perfusion pressure, were determined within areas with delayed TTP and compared with values from contralateral unaffected areas after segmentation of normal-appearing hypoperfused WM and cortical regions. Hemispheric asymmetry indices were calculated for all parameters. RESULTS: Quantitative T2 was significantly prolonged (P < .01) in hypoperfused tissue and correlated significantly (P < .01) with TTP delay and relative CBF/relative CBV reduction in WM. Significant correlations (P < .001) between TTP delay and the relative CBF/relative CBV ratio were found both in WM and in cortical areas. CONCLUSIONS: Quantitative T2 can be used as a marker of microstructural tissue damage even in normal-appearing GM and WM within a vascular territory affected by high-grade carotid occlusive disease. Furthermore, the extent of damage correlates with the degree of hemodynamic failure measured by DSC perfusion parameters.
- 1 August 2017
- Published by Elsevier in NeuroImage
- Vol. 157, 476-485
Quantitative in vivo T2 mapping using fast spin echo techniques – A linear correction procedure
- 1 August 2017
- Published by Elsevier in NeuroImage
- Vol. 157, 476-485
Quantitative in vivo T2 mapping using fast spin echo techniques – A linear correction procedure