PBPieter Blignaut

Pieter Blignaut

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pieter Blignaut has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Convolutional Neural Network-Based Methods for Eye Gaze Estimation: A Survey

    by Andronicus A. Akinyelu, Pieter Blignaut

    Eye tracking is becoming a very important tool across many domains, including human-computer-interaction, psychology, computer vision, and medical diagnosis. Different methods have been used to tackle eye tracking, however, some of them are inaccurate under real-world conditions, while some require explicit user calibration which can be burdensome. Some of these methods suffer from poor image quality and variable light conditions. The recent success and prevalence of deep learning have greatly improved the performance of eye-tracking. The availability of large-scale datasets has further improved the performance of deep learning-based methods. This paper presents a survey of the current state-of-the-art on deep learning-based gaze estimation techniques, with a focus on Convolutional Neural Networks (CNN). This paper also provides a survey on other machine learning-based gaze estimation techniques. This study aims to empower the research community with valuable and useful insights that can enhance the design and development of improved and efficient deep learning-based eye-tracking models. This study also provides information on various pre-trained models, network architectures, and open-source datasets that are useful for training deep learning models.


  • Open Access

    A cost function to determine the optimum filter and parameters for stabilizing gaze data

    by Pieter Blignaut

    Prior to delivery of data, eye tracker software may apply filtering to correct for noise. Although filtering produces much better precision of data, it may add to the time it takes for the reporting of gaze data to stabilise after a saccade due to the usage of a sliding window. The effect of various filters and parameter settings on accuracy, precision and filter related latency is examined. A cost function can be used to obtain the optimal parameters (filter, length of window, metric and threshold for removal of samples and removal percentage). It was found that for any of the FIR filters, the standard deviation of samples can be used to remove 95% of samples in the window so than an optimum combination of filter related latency and precision can be obtained. It was also confirmed that for unfiltered data, the shape of noise, signified by RMS/STD, is around √2 as expected for white noise, whereas lower RMS/STD values were observed for all filters.


  • Open Access

    Visualization and quantification of eye tracking data for the evaluation of oculomotor function

    by Pieter Blignaut, Elize Janse van Rensburg, Marsha Oberholzer


  • The Effect of Learners’ Knowledge of the Divisibility Rules on their Gaze Behaviour

    by Pieter Potgieter, Pieter Blignaut

    The Department of Basic Education in South Africa has identified factorisation as a problem area in Mathematics teaching. Learners in earlier grades are exposed to mathematical tasks, involving concepts, such as factors of integers, fractions, equivalent fractions and prime numbers, that are easier to solve when the divisibility rules are applied. An experiment was designed to investigate the effect of learners’ knowledge and their application of the divisibility rules on their gaze behaviour. Seventy-eight learners in Grades 4–7 participated in an eye-tracking study where questions on divisibility were presented on a computer screen. Learners were expected to indicate whether a five-digit dividend was divisible by a divisor and provide reasons for their answers. Gaze behaviour (expressed as the percentage of total fixation time that was spent on each digit), along with learners’ verbal responses were used to determine whether a given divisibility rule was applied correctly. The findings show that learners apply different strategies to inspect the dividend when they know the divisibility rules and apply them correctly as opposed to when they do not know the rules and/or apply them incorrectly. It is argued that, since knowledge of the divisibility rules is a reliable predictor for gaze behaviour, gaze behaviour can in turn be used to assist teachers to identify a lack of knowledge and/or the incorrect application of the divisibility rules. Teachers can then cautiously intervene with revision to assist learners whose gaze behaviour indicates that they need assistance.


  • Open Access

    The Effect of Real-time Headbox Adjustments on Data Quality

    by Pieter Blignaut

    Following a patent owned by Tobii, the framerate of a CMOS camera can be increased by reducing the size of the recording window so that it fits the eyes with minimum room to spare. The position of the recording window can be dynamically adjusted within the camera sensor area to follow the eyes as the participant moves the head. Since only a portion of the camera sensor data is communicated to the computer and processed, much higher framerates can be achieved with the same CPU and camera.Eye trackers can be expected to present data at a high speed, with good accuracy and precision, small latency and with minimal loss of data while allowing participants to behave as normally as possible. In this study, the effect of headbox adjustments in real-time is investigated with respect to the above-mentioned parameters.It was found that, for the specific camera model and tracking algorithm, one or two headbox adjustments per second, as would normally be the case during recording of human participants, could be tolerated in favour of a higher framerate. The effect of adjustment of the recording window can be reduced by using a larger recording window at the cost of the framerate.


  • Open Access

    Using smooth pursuit calibration for difficult-to-calibrate participants

    by Pieter Blignaut

    Although the 45-dots calibration routine of a previous study (Blignaut, 2016) provided very good accuracy, it requires intense mental effort and the routine proved to be unsuccessful for young children who struggle to maintain concentration. The calibration procedures that are normally used for difficult-to-calibrate participants, such as autistic children and infants, do not suffice since they are not accurate enough and the reliability of research results might be jeopardised.Smooth pursuit has been used before for calibration and is applied in this paper as an alternative routine for participants who are difficult to calibrate with conventional routines. Gaze data is captured at regular intervals and many calibration targets are generated while the eyes are following a moving target. The procedure could take anything between 30 s and 60 s to complete, but since an interesting target and/or a conscious task may be used, participants are assisted to maintain concentration.It was proven that the accuracy that can be attained through calibration with a moving target along an even horizontal path is not significantly worse than the accuracy that can be attained with a standard method of watching dots appearing in random order. The routine was applied successfully for a group of children with ADD, ADHD and learning abilities.This result is important as it provides for easier calibration – especially in the case of participants who struggle to keep their gaze focused and stable on a stationary target for long enough.


  • Open Access

    Performance of a simple remote video-based eye tracker with GPU acceleration

    by Jean-Pierre Du Plessis, Pieter Blignaut

    Eye tracking is a well-established tool that is often utilised in research. There are currently many different types of eye trackers available, but they are either expensive, or provide a relatively low sampling frequency. The eye tracker presented in this paper was developed in an effort to address the lack of low-cost high-speed eye trackers. It utilises the Graphical Processing Unit (GPU) in an attempt to parallelise aspects of the process to localize feature points in eye images to attain higher sampling frequencies. Moreover, the proposed implementation allows for the system to be used on a variety of different GPUs. The developed solution is capable of sampling at frequencies of 200 Hz and higher, while allowing for head movements within an area of 10×6×10 cm and an average accuracy of one degree of visual angle. The entire system can be built for less than 700 euros, and will run on a mid-range laptop.


  • Open Access

    Idiosyncratic Feature-Based Gaze Mapping

    by Pieter Blignaut

    It is argued that polynomial expressions that are normally used for remote, video-based, low cost eye tracking systems, are not always ideal to accommodate individual differences in eye cleft, position of the eye in the socket, corneal bulge, astigmatism, etc. A procedure to identify a set of polynomial expressions that will provide the best possible accuracy for a specific individual is proposed. It is also proposed that regression coefficients are recalculated in real-time, based on a subset of calibration points in the region of the current gaze and that a real-time correction is applied, based on the offsets from calibration targets that are close to the estimated point of regard.It was found that if no correction is applied, the choice of polynomial is critically important to get an accuracy that is just acceptable. Previously identified polynomial sets were confirmed to provide good results in the absence of any correction procedure. By applying real-time correction, the accuracy of any given polynomial improves while the choice of polynomial becomes less critical. Identification of the best polynomial set per participant and correction technique in combination with the aforementioned correction techniques, lead to an average error of 0.32° (sd = 0.10°) over 134 participant recordings.The proposed improvements could lead to low-cost systems that are accurate and fast enough to do reading research or other studies where high accuracy is expected at framerates in excess of 200 Hz.