Vyacheslav Zakosarenko has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Photon Number Resolving Mo/AuPd Transition Edge Sensors for Visible up to NIR Wavelength

    by Matthias Schmelz, Vitaly Shvab, Katja Peiselt, Jürgen Kunert, Gabriel Zieger, Vyacheslav Zakosarenko, Gregor Oelsner, Ronny Stolz

    We present results of the development of transition-edge sensors (TES) based on Mo/AuPd thermistors aiming for photon number resolution in the visible up to NIR wavelength. TES are deposited on an oxidized solid Silicon substrate and make use of electron-phonon decoupling at mK-temperatures generating a weak link for thermal relaxation. The Mo/AuPd bilayers have a tuned critical temperature of approximately 180 mK and are being read out by making use of a series SQUID array, both implemented in a setup in an adiabatic demagnetization refrigerator. Optical pulses, generated via gated laser sources at room temperature, are fed via an optical single mode fiber to the TES. Their absorption is measured as a TES pulse response with a SQUID array. By means of pulse amplitude histograms (PAH), single photon resolution in the visible to NIR has been achieved. We've proven TES pulse response originating from single photon absorption in the TES via fitting the PAH with a Poissonian distribution. For 405 nm laser wavelength, we've achieved an energy resolution of about 0.7 eV, determined via analysis of the raw measurement data using PAH.

  • Scalable Microwave SQUID Multiplexer Readout Architecture for TES-Based THz Security Camera

    by Matthias Schmelz, Erik Heinz, Katja Peiselt, Gabriel Zieger, Oliver Brandel, Detlef Born, Jürgen Kunert, Michael Siegel, Vyacheslav Zakosarenko, Matthias Meyer, et al.

    In this article, we have developed a scalable superconducting quantum interference device (SQUID)-based microwave multiplexer (µMUX) readout architecture adapted for arrays of transition edge sensors (TESs) to be exploited in a terahertz security camera. The camera system combines a scanning optics together with a 128-pixel TES array and aims for security gate operations with a standoff detection distance of up to 25 m. The developed frequency-domain µMUX is used to read out all feed-horn-coupled TESs based on aluminum thermistors, with noise limited by intrinsic TES noise. Both the TESs and µMUXs are operated in a compact cryostat with a base temperature of about 0.9 K. The µMUX has been fabricated in the cross-type $\text{Nb}/ \text{AlO}\_{\rm{x}}/ \text{Nb}$ Josephson junction process developed at the Leibniz Institute of Photonic Technology and incorporates high-quality superconducting thin-film resonators with resonant frequencies in the range of 5–6 GHz. An accordingly implemented field-programmable-gate-array-based readout electronics enables the simultaneous and continuous real-time readout of 128 rf-SQUIDs, including a flux ramp modulation scheme. In operation with the aluminum TES, we achieved a dark noise equivalent power of about $2.5\; \text{fW}/ \text{Hz}^{1/ 2}$ while providing a TES readout rate of 3.75 kHz, necessary for a video frame rate of 25 Hz of the security camera.


  • Highly Sensitive DC SQUID Arrays for the Readout of Optical TES at mK Temperatures

    by Matthias Schmelz, Vitaliy Shvab, Katja Peiselt, Jürgen Kunert, Vyacheslav Zakosarenko, Thomas Stöhlker, Gregor Oelsner, Ronny Stolz

    We present advancements of our sub-micron crosstype Nb/AlOx/Nb Josephson junction technology by implementing an additional highly conductive resistive layer, e.g. for thermalization structures. This allows for shifting the typically observed thermal decoupling of shunt resistors of highly sensitive dc SQUIDs and SQUID arrays down to temperatures in the mK range. We show results on the technological integration, device design of series SQUID arrays, and their characterization at 4.2 K down to 65 mK. Measurements were performed in an adiabatic demagnetization refrigerator (ADR). As an application scenario, we've successfully implemented them as readout circuitry for optical transition edge sensors (TES) operated at 150 mK requiring both, low-noise and large bandwidth of the readout implemented in a flux locked loop configuration


  • High Inductance Cryogenic Current Comparators for Beamlines

    by V. Tympel, F. Machalett, T. Stöhlker, L. Crescimbeni, T. Schönau, D. Haider, T. Sieber, M. Schwickert, F. Schmidl, P. Seidel, et al.

    The Cryogenic Current Comparator (CCC) for beamlines is designed for the non-destructive, highly sensitive, and absolute measurement of bunched (AC) and un-bunched (DC) beam current of charged particle in the nA range using the external magnetic field of the beam. Niobium based CCCs are running at the CERN-Antiproton Decelerator (beamline diameter of 100 mm) and are tested at the CRYRING@ESR. CCCs of the xD-series (extended dimension) can support the new facility for antiproton and ion research (FAIR) at GSI (Gesellschaft für Schwerionenforschung) in Darmstadt with a 150 mm beamline diameter. The large FAIR-Nb-CCC-xD has an inductance of 80 µH. An effective way to increase the sensitivity is to increase the inductance of the pickup coils. The two first CCCs of the new Sm-series (smart & small) have overall inductances of 200 and 300 µH. This work describes the individual development steps, starting with the superconducting pickup coils. For CCCs with a flux concentrating core in the pickup coil, the subsequent current noise of the CCC is determined by the cores parameter. On the basis of low-temperature L s R s -measurements on pickup coils, it is shown how the fluctuation–dissipation theorem (FDT) can be used to infer the current noise of the CCC. For the first time a white noise of 1 pA rms /√Hz could be achieved. A superconducting, meandering shield filters the circular magnetic field and suppresses interference fields. Through step-by-step setup and measurements, it follows how this affects CCC system parameters. Finally, it was possible to measure current impulses below 1 nA pp in the laboratory.

  • SQUID amplifiers for axion search experiments

    by Andrei Matlashov, Matthias Schmelz, Vyacheslav Zakosarenko, Ronny Stolz, Yannis K. Semertzidis


  • 3D nanoSQUID based on tunnel nano-junctions with an energy sensitivity of 1.3 h at 4.2 K

    by M. Schmelz, A. Vettoliere, V. Zakosarenko, N. De Leo, M. Fretto, R. Stolz, C. Granata

    We report the performance of a reliable three-dimensional nanometer-sized Superconducting QUantum Interference Device (SQUID). The use of superconductor-isolator-superconductor Nb/Al-AlOx/Nb Josephson tunnel junctions together with small SQUID loop dimensions permits a high modulation depth of the SQUID's critical current and thus leads to very low intrinsic flux noise of the device. In particular, we present electrical characterization including detailed noise investigations. At 4.2 K, two-stage noise measurements with a SQUID as a low noise preamplifier result in a white flux noise of 51 nΦ0/Hz1/2, which is equivalent to an energy resolution of 1.3 h, with h being Planck's constant. Simulation of spin sensitivities results in about 1 μB/Hz1/2 for an electron spin positioned directly above the SQUID ring.


  • A three-axis SQUID-based absolute vector magnetometer

    by T. Schönau, V. Zakosarenko, M. Schmelz, R. Stolz, S. Anders, S. Linzen, M. Meyer, H.-G. Meyer

    We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz1/2. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.