Sabino Zani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabino Zani has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Michael E. Lidsky
Department of Surgery, Duke University School of Medicine, Durham, USA
9 shared publications - Peter J. Allen
Department of Surgery, Duke University Medical Center, Durham, USA
5 shared publications - Thomas Peter Kingham
Hepatopancreatobiliary Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, USA
5 shared publications - Alice C. Wei
Hepatopancreatobiliary Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, USA
4 shared publications Dan G. Blazer
Department of Surgery, Division of Surgical Oncology, Duke University, Durham, USA
4 shared publications- Jeffrey A. Drebin
Hepatopancreatobiliary Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, USA
4 shared publications
Latest Publications
- 18 September 2026
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 33 (13) , 11182-11190
Recurrence Patterns of Resected Ampullary Adenocarcinoma and Implications for Multimodal Therapy: A Hidden Genome–Derived Analysis from the Ampullary Cancer Collaborative
- 18 September 2026
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 33 (13) , 11182-11190
Recurrence Patterns of Resected Ampullary Adenocarcinoma and Implications for Multimodal Therapy: A Hidden Genome–Derived Analysis from the Ampullary Cancer Collaborative
- 9 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055009
Bayesian neural networks for uncertainty-aware tissue identification using bioimpedance-based frequency response similarity metrics
This work sought to improve bioimpedance-based tissue identification model performance on an eight-tissue dataset by employing frequency response function similarity metrics (FRFSMs) as feature generators and Bayesian neural networks (BNNs) for accurate uncertainty estimations. Inspired by structural dynamics, FRFSMs were applied in a new context to generate features from mean baseline measurements, thereby extracting information of how unclassified measurements compare to previous ones. Additionally, BNNs were constructed to directly estimate model parameter uncertainty effects on classification uncertainty. Finally, a stacking ensemble technique combined base model outputs to train a meta-learner for improving performance. Models trained with similarity metric features achieved higher mean accuracies and better tissue specific F 1-scores than those trained with measurements. BNNs with temperature scaling reduced the expected calibration error of the standard feedforward networks by 19%–83%, indicating significant enhancement of uncertainty quantification. Ensembles achieved higher mean accuracies than base models, with maximum accuracies over 75%, and maintained the enhanced uncertainty quantification. The implementation of similarity metric inputs and BNNs for bioimpedance-based tissue identification offered a clear improvement in mean accuracy and uncertainty quantification over traditional models using measurements only. This marks an essential step towards enabling bioimpedance as a feasible sensing option for real-time tissue identification. Attaining dependable bioimpedance-based tissue identification will provide a foundation for new technologies due to economical and implementation advantages over competing methods while the added uncertainty-awareness makes it an excellent candidate for medical applications because it can provide additional context for outputs to users.
- 9 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055009
Bayesian neural networks for uncertainty-aware tissue identification using bioimpedance-based frequency response similarity metrics
This work sought to improve bioimpedance-based tissue identification model performance on an eight-tissue dataset by employing frequency response function similarity metrics (FRFSMs) as feature generators and Bayesian neural networks (BNNs) for accurate uncertainty estimations. Inspired by structural dynamics, FRFSMs were applied in a new context to generate features from mean baseline measurements, thereby extracting information of how unclassified measurements compare to previous ones. Additionally, BNNs were constructed to directly estimate model parameter uncertainty effects on classification uncertainty. Finally, a stacking ensemble technique combined base model outputs to train a meta-learner for improving performance. Models trained with similarity metric features achieved higher mean accuracies and better tissue specific F 1-scores than those trained with measurements. BNNs with temperature scaling reduced the expected calibration error of the standard feedforward networks by 19%–83%, indicating significant enhancement of uncertainty quantification. Ensembles achieved higher mean accuracies than base models, with maximum accuracies over 75%, and maintained the enhanced uncertainty quantification. The implementation of similarity metric inputs and BNNs for bioimpedance-based tissue identification offered a clear improvement in mean accuracy and uncertainty quantification over traditional models using measurements only. This marks an essential step towards enabling bioimpedance as a feasible sensing option for real-time tissue identification. Attaining dependable bioimpedance-based tissue identification will provide a foundation for new technologies due to economical and implementation advantages over competing methods while the added uncertainty-awareness makes it an excellent candidate for medical applications because it can provide additional context for outputs to users.
- 4 June 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
The OncoReach Stylet for Brachytherapy: Design Evaluation and Pilot Study
Cervical cancer accounts for a significant portion of the global cancer burden among women. Interstitial brachytherapy (ISBT) is a standard procedure for treating cervical cancer; it involves placing a radioactive source through a straight hollow needle within or in close proximity to the tumor and surrounding tissue. However, the use of straight needles limits surgical planning to a linear needle path. We present the OncoReach stylet, a handheld, tendon-driven steerable stylet designed for compatibility with standard ISBT 15- and 13-gauge needles. Building upon our prior work, we evaluated design parameters like needle gauge, spherical joint count and spherical joint placement, including an asymmetric disk design to identify a configuration that maximizes bending compliance while retaining axial stiffness. Free space experiments quantified tip deflection across configurations, and a two-tube Cosserat rod model accurately predicted the centerline shape of the needle for most trials. The best performing configuration was integrated into a reusable handheld prototype that enables manual actuation. A patient-derived, multi-composite phantom model of the uterus and pelvis was developed to conduct a pilot study of the OncoReach steerable stylet with one expert user. Results showed the ability to steer from less-invasive, medial entry points to reach the lateral-most targets, underscoring the significance of steerable stylets.
- 4 June 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
The OncoReach Stylet for Brachytherapy: Design Evaluation and Pilot Study
Cervical cancer accounts for a significant portion of the global cancer burden among women. Interstitial brachytherapy (ISBT) is a standard procedure for treating cervical cancer; it involves placing a radioactive source through a straight hollow needle within or in close proximity to the tumor and surrounding tissue. However, the use of straight needles limits surgical planning to a linear needle path. We present the OncoReach stylet, a handheld, tendon-driven steerable stylet designed for compatibility with standard ISBT 15- and 13-gauge needles. Building upon our prior work, we evaluated design parameters like needle gauge, spherical joint count and spherical joint placement, including an asymmetric disk design to identify a configuration that maximizes bending compliance while retaining axial stiffness. Free space experiments quantified tip deflection across configurations, and a two-tube Cosserat rod model accurately predicted the centerline shape of the needle for most trials. The best performing configuration was integrated into a reusable handheld prototype that enables manual actuation. A patient-derived, multi-composite phantom model of the uterus and pelvis was developed to conduct a pilot study of the OncoReach steerable stylet with one expert user. Results showed the ability to steer from less-invasive, medial entry points to reach the lateral-most targets, underscoring the significance of steerable stylets.
- 23 December 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 40 (3) , 2297-2303
Quantitative assessment of laparoscopic camera navigation skill: a retrospective cross-sectional study
Objective To evaluate whether a low-cost, automated tool using trajectory-based metrics and real-time computer vision can objectively assess laparoscopic camera navigation (LCN) skill and distinguish between levels of surgical experience. Summary background data Laparoscopic camera navigation (LCN) is essential to the safety and success of minimally invasive surgery. Despite its importance, LCN is often overlooked in formal training and lacks standardized assessment methods. Existing tools are labor-intensive, subjective, and not scalable, creating a need for efficient, objective evaluation strategies. Methods This cross-sectional observational validation study was conducted from January to April 2025 in a single-site academic surgical training laboratory. Fifty-nine participants (6 expert surgeons, 12 senior residents, 26 junior residents, and 15 novices) completed a standardized LCN task using a custom-designed maze and a 30° laparoscope in a bench-top trainer. Real-time computer vision detected targets, while an electromagnetic tracking system recorded the laparoscope’s trajectory. Five automated performance metrics were collected: space coverage, dimensionless jerk, rotational smoothness, idle time, and total task time. A principal component analysis (PCA) was used to generate a composite performance score (0–100). Results All participants completed the task. Experts demonstrated lower space coverage (121 ± 31 cm2) and shorter completion times (163 ± 59 s) compared with novices (205 ± 67 cm2; 497 ± 133 s). Experts also outperformed novices in jerk, rotational smoothness, and idle time metrics. PCA-derived scores were significantly higher for experts (92 ± 3) than novices (34 ± 24), with all metrics showing statistically significant differences (p < .005). Conclusions This automated, low-cost tool reliably quantified LCN skill across training levels using interpretable metrics. Its objectivity and scalability support integration into surgical education for formative feedback and standardized assessment.
- 23 December 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 40 (3) , 2297-2303
Quantitative assessment of laparoscopic camera navigation skill: a retrospective cross-sectional study
Objective To evaluate whether a low-cost, automated tool using trajectory-based metrics and real-time computer vision can objectively assess laparoscopic camera navigation (LCN) skill and distinguish between levels of surgical experience. Summary background data Laparoscopic camera navigation (LCN) is essential to the safety and success of minimally invasive surgery. Despite its importance, LCN is often overlooked in formal training and lacks standardized assessment methods. Existing tools are labor-intensive, subjective, and not scalable, creating a need for efficient, objective evaluation strategies. Methods This cross-sectional observational validation study was conducted from January to April 2025 in a single-site academic surgical training laboratory. Fifty-nine participants (6 expert surgeons, 12 senior residents, 26 junior residents, and 15 novices) completed a standardized LCN task using a custom-designed maze and a 30° laparoscope in a bench-top trainer. Real-time computer vision detected targets, while an electromagnetic tracking system recorded the laparoscope’s trajectory. Five automated performance metrics were collected: space coverage, dimensionless jerk, rotational smoothness, idle time, and total task time. A principal component analysis (PCA) was used to generate a composite performance score (0–100). Results All participants completed the task. Experts demonstrated lower space coverage (121 ± 31 cm2) and shorter completion times (163 ± 59 s) compared with novices (205 ± 67 cm2; 497 ± 133 s). Experts also outperformed novices in jerk, rotational smoothness, and idle time metrics. PCA-derived scores were significantly higher for experts (92 ± 3) than novices (34 ± 24), with all metrics showing statistically significant differences (p < .005). Conclusions This automated, low-cost tool reliably quantified LCN skill across training levels using interpretable metrics. Its objectivity and scalability support integration into surgical education for formative feedback and standardized assessment.
- Open Access
- 16 June 2025
- Published by Springer Nature in Annals of Surgical Oncology
- p. 1-2
ASO Visual Abstract: Robotic Versus Open Placement of Hepatic Artery Infusion Pumps
- 16 June 2025
- Published by Springer Nature in Annals of Surgical Oncology
- p. 1-2
Open AccessASO Visual Abstract: Robotic Versus Open Placement of Hepatic Artery Infusion Pumps
- 27 March 2025
- Published by Springer Nature
- p. 71-77
Robotic Approach to Hepatic Arterial Infusion Pump Placement
- 27 March 2025
- Published by Springer Nature
- p. 71-77
Robotic Approach to Hepatic Arterial Infusion Pump Placement
- Open Access
- 28 January 2025
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (5) , 3488-3498
Robotic Versus Open Placement of Hepatic Artery Infusion Pumps
Background: A growing number of centers offer hepatic artery infusion pump (HAIP) chemotherapy for advanced liver malignancies. While small series have demonstrated feasibility of robotic HAIP placement, comparison of outcomes with open placement is lacking. We compared outcomes after robotic versus open HAIP placement. Methods: We retrospectively reviewed HAIP placement without concurrent hepatectomy at Memorial Sloan Kettering Cancer Center from 1 January 2011 to 15 September 2022, and Duke Health from 1 November 2018 to 18 May 2023. Patients with prior liver surgery or who required catheterization of a non-standard vessel were excluded. Propensity score matching weights (PSMW) were calculated using age, sex, race, body mass index, American Society of Anesthesiologists class, neoadjuvant chemotherapy, colorectal procedure, and institution. Survey-weighted generalized linear models assessed the relationship between approach and outcomes. Results: Of 2002 consecutive HAIP placements, 819 (645 open/174 robotic) met the inclusion criteria. A higher proportion of open procedures involved combined colorectal procedures; other patient characteristics were similar. Overall, 15% of patients experienced an HAIP-specific complication and 12% required re-intervention; 2.7% had HAIP failure ≤ 90 days. After PSMW, the robotic approach had a longer operative time (β = 68 min, 95% confidence interval [CI] 55–81, p < 0.001) but shorter length of stay (β = − 1.8 days, 95% CI − 2.3 to 1.3, p < 0.001). The robotic approach was associated with increased HAIP-specific complications (odds ratio [OR] 1.72, p = 0.025) and re-intervention (OR 2.33, p < 0.001), with no difference in time to initiation of HAIP chemotherapy or HAIP failure. Conclusions: Robotic HAIP placement was associated with increased postoperative complications and significantly shorter length of stay, with similar time to initiation of HAIP therapy. There was no difference in the rate of early HAIP failure versus the open approach. These results suggest robotic HAIP placement is feasible and effective.
- 28 January 2025
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (5) , 3488-3498
Open AccessRobotic Versus Open Placement of Hepatic Artery Infusion Pumps
Background: A growing number of centers offer hepatic artery infusion pump (HAIP) chemotherapy for advanced liver malignancies. While small series have demonstrated feasibility of robotic HAIP placement, comparison of outcomes with open placement is lacking. We compared outcomes after robotic versus open HAIP placement. Methods: We retrospectively reviewed HAIP placement without concurrent hepatectomy at Memorial Sloan Kettering Cancer Center from 1 January 2011 to 15 September 2022, and Duke Health from 1 November 2018 to 18 May 2023. Patients with prior liver surgery or who required catheterization of a non-standard vessel were excluded. Propensity score matching weights (PSMW) were calculated using age, sex, race, body mass index, American Society of Anesthesiologists class, neoadjuvant chemotherapy, colorectal procedure, and institution. Survey-weighted generalized linear models assessed the relationship between approach and outcomes. Results: Of 2002 consecutive HAIP placements, 819 (645 open/174 robotic) met the inclusion criteria. A higher proportion of open procedures involved combined colorectal procedures; other patient characteristics were similar. Overall, 15% of patients experienced an HAIP-specific complication and 12% required re-intervention; 2.7% had HAIP failure ≤ 90 days. After PSMW, the robotic approach had a longer operative time (β = 68 min, 95% confidence interval [CI] 55–81, p < 0.001) but shorter length of stay (β = − 1.8 days, 95% CI − 2.3 to 1.3, p < 0.001). The robotic approach was associated with increased HAIP-specific complications (odds ratio [OR] 1.72, p = 0.025) and re-intervention (OR 2.33, p < 0.001), with no difference in time to initiation of HAIP chemotherapy or HAIP failure. Conclusions: Robotic HAIP placement was associated with increased postoperative complications and significantly shorter length of stay, with similar time to initiation of HAIP therapy. There was no difference in the rate of early HAIP failure versus the open approach. These results suggest robotic HAIP placement is feasible and effective.
- 18 January 2025
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (4) , 2456-2466
Adjuvant Cytotoxic Chemotherapy may not be Associated with a Survival Advantage for Resected Intrahepatic Cholangiocarcinoma
Randomized data suggest improved survival with adjuvant chemotherapy for biliary tract cancers; however, subset analyses of intrahepatic cholangiocarcinoma
- 18 January 2025
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (4) , 2456-2466
Adjuvant Cytotoxic Chemotherapy may not be Associated with a Survival Advantage for Resected Intrahepatic Cholangiocarcinoma
Randomized data suggest improved survival with adjuvant chemotherapy for biliary tract cancers; however, subset analyses of intrahepatic cholangiocarcinoma
- Open Access
- 6 September 2024
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (11) , 7058-7066
Metroticket approach in a retrospective cohort study to predict overall survival after surgical resection for hepatocellular carcinoma
Background: Surgical resection is a curative therapy for early-stage hepatocellular carcinoma (HCC) patients meeting the Milan criteria as well as a widely used therapy in intermediate-stage HCC. However, intermediate-stage HCC encompasses a wide spectrum of disease and there is a lack of good predictive models for the long-term clinical outcome of HCC patients currently. Here, the authors adopt Mazzaferro’s Metroticket 2.0 to create a robust survival prediction model for intermediate-stage HCC patients undergoing surgical resection. Our algorithm considers age, AFP levels, ALBI score, and nodule size/number to generate survival estimates in an accessible graph format. Importantly, their model surpasses the American Joint Committee on Cancer staging model and was validated with independent US patient data. Methods: The authors conducted a retrospective analysis of OS and RFS in early- and intermediate-stage HCC patients treated with liver resection, including a training cohort in Singapore and a validation cohort in North Carolina, USA. Results: The authors recorded 278 deaths (35.0%) and 428 patients (53.9%) in the first 5 years after surgical resection; higher ALBI score, higher lnAFP, more advanced age and higher tumour burden index were identified as significant parameters. The overall predictive capability of our model, with the inclusion of AFP, is reflected with a UNO’s C-statistic of 0.655, which is 1.11 times better than the 0.5895 C-statistic of the 8th AJCC TNM Staging model. Conclusions: The authors’ modified Metroticket model allows for more granular and better-informed prognostication. This will help surgeons and patients make accurate comparisons between the clinical outcomes of surgical resection and other non-surgical treatments.
- 6 September 2024
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (11) , 7058-7066
Open AccessMetroticket approach in a retrospective cohort study to predict overall survival after surgical resection for hepatocellular carcinoma
Background: Surgical resection is a curative therapy for early-stage hepatocellular carcinoma (HCC) patients meeting the Milan criteria as well as a widely used therapy in intermediate-stage HCC. However, intermediate-stage HCC encompasses a wide spectrum of disease and there is a lack of good predictive models for the long-term clinical outcome of HCC patients currently. Here, the authors adopt Mazzaferro’s Metroticket 2.0 to create a robust survival prediction model for intermediate-stage HCC patients undergoing surgical resection. Our algorithm considers age, AFP levels, ALBI score, and nodule size/number to generate survival estimates in an accessible graph format. Importantly, their model surpasses the American Joint Committee on Cancer staging model and was validated with independent US patient data. Methods: The authors conducted a retrospective analysis of OS and RFS in early- and intermediate-stage HCC patients treated with liver resection, including a training cohort in Singapore and a validation cohort in North Carolina, USA. Results: The authors recorded 278 deaths (35.0%) and 428 patients (53.9%) in the first 5 years after surgical resection; higher ALBI score, higher lnAFP, more advanced age and higher tumour burden index were identified as significant parameters. The overall predictive capability of our model, with the inclusion of AFP, is reflected with a UNO’s C-statistic of 0.655, which is 1.11 times better than the 0.5895 C-statistic of the 8th AJCC TNM Staging model. Conclusions: The authors’ modified Metroticket model allows for more granular and better-informed prognostication. This will help surgeons and patients make accurate comparisons between the clinical outcomes of surgical resection and other non-surgical treatments.
- Open Access
- 26 July 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (8) , e1682
Video-assisted Retroperitoneal Debridement for Graft Pancreatitis
- 26 July 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (8) , e1682
Open AccessVideo-assisted Retroperitoneal Debridement for Graft Pancreatitis