Erin Victoria McGillick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Erin Victoria McGillick has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Janna Leigh Morrison
University of South Australia
16 shared publications - Sandra Orgeig
University of South Australia
14 shared publications - Kelly J. Crossley
Hudson Institute of Medical Research
11 shared publications Stuart B. Hooper
The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
10 shared publications- Arjan B. Te Pas
Leiden University Medical Center
7 shared publications - Stuart Brian Hooper
Hudson Institute of Medical Research
7 shared publications
Latest Publications
- Open Access
- 18 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10) , 105002
Estimations of lung structural properties from a single propagation-based dark-field x-ray image
Objective. To employ a single-projection dark-field imaging approach to obtain statistical information on alveolar size and number as key structural indicators of lung health. Approach. The algorithm employed here retrieves the projected thickness of the sample from a propagation-based phase contrast image using the transport-of-intensity equation. The first Born approximation is then used to isolate the dark-field signal associated with edge scattering, which increases the visibility of microstructure boundaries. Poly(methyl methacrylate) spheres of known sizes were imaged first as an idealised alveolar model. The dark-field signal was then recovered from propagation-based phase-contrast x-ray images of the lungs of small mammals using this method. Main results. The retrieved dark-field signal was found to be proportional to both the alveolar size ( R 2 = 0.85 ) and the number in projection ( R 2 = 0.69 ), and these measurements could be combined to provide an estimate of the total surface area of the alveolar interfaces ( R 2 = 0.78 ). Significance. This demonstrates the approach’s ability to potentially indicate lung health using the dark-field signal retrieved from a single-phase-contrast x-ray image.
- 18 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10) , 105002
Open AccessEstimations of lung structural properties from a single propagation-based dark-field x-ray image
Objective. To employ a single-projection dark-field imaging approach to obtain statistical information on alveolar size and number as key structural indicators of lung health. Approach. The algorithm employed here retrieves the projected thickness of the sample from a propagation-based phase contrast image using the transport-of-intensity equation. The first Born approximation is then used to isolate the dark-field signal associated with edge scattering, which increases the visibility of microstructure boundaries. Poly(methyl methacrylate) spheres of known sizes were imaged first as an idealised alveolar model. The dark-field signal was then recovered from propagation-based phase-contrast x-ray images of the lungs of small mammals using this method. Main results. The retrieved dark-field signal was found to be proportional to both the alveolar size ( R 2 = 0.85 ) and the number in projection ( R 2 = 0.69 ), and these measurements could be combined to provide an estimate of the total surface area of the alveolar interfaces ( R 2 = 0.78 ). Significance. This demonstrates the approach’s ability to potentially indicate lung health using the dark-field signal retrieved from a single-phase-contrast x-ray image.
- Open Access
- 23 January 2023
- Published by Wiley in The Anatomical Record
- Vol. 308 (4) , 1082-1093
Effect of prenatal diaphragmatic hernia on pulmonary arterial morphology
Congenital diaphragmatic hernia (CDH) is a major cause of severe lung hypoplasia and pulmonary hypertension in the newborn. While the pulmonary hypertension is thought to result from abnormal vascular development and arterial vasoreactivity, the anatomical changes in vascular development are unclear. We have examined the 3D structure of the pulmonary arterial tree in rabbits with a surgically induced diaphragmatic hernia (DH). Fetal rabbits (n = 6) had a left‐sided DH created at gestational day 23 (GD23), delivered at GD30, and briefly ventilated; sham‐operated litter mates (n = 5) acted as controls. At postmortem the pulmonary arteries were filled with a radio‐opaque resin before the lungs were scanned using computed tomography (CT). The 3D reconstructed images were analyzed based on vascular branching hierarchy using the software Avizo 2020.2. DH significantly reduced median number of arteries (2,579 (8440) versus 576 (442), p = .017), artery numbers per arterial generation, mean total arterial volume (43.5 ± 8.4 vs. 19.9 ± 3.1 μl, p = .020) and mean total arterial cross‐sectional area (82.5 ± 2.3 vs. 28.2 ± 6.2 mm2, p =.036). Mean arterial radius was increased in DH kittens between the eighth and sixth branching generation and mean arterial length between the sixth and 28th branching generation. A DH in kittens resulted in threefold reduction in pulmonary arterial cross‐sectional area, primarily due to reduced arterial branching. Thus, the reduction in arterial cross‐sectional area could be a major contributor to pulmonary hypertension infants with CDH.
- 23 January 2023
- Published by Wiley in The Anatomical Record
- Vol. 308 (4) , 1082-1093
Open AccessEffect of prenatal diaphragmatic hernia on pulmonary arterial morphology
Congenital diaphragmatic hernia (CDH) is a major cause of severe lung hypoplasia and pulmonary hypertension in the newborn. While the pulmonary hypertension is thought to result from abnormal vascular development and arterial vasoreactivity, the anatomical changes in vascular development are unclear. We have examined the 3D structure of the pulmonary arterial tree in rabbits with a surgically induced diaphragmatic hernia (DH). Fetal rabbits (n = 6) had a left‐sided DH created at gestational day 23 (GD23), delivered at GD30, and briefly ventilated; sham‐operated litter mates (n = 5) acted as controls. At postmortem the pulmonary arteries were filled with a radio‐opaque resin before the lungs were scanned using computed tomography (CT). The 3D reconstructed images were analyzed based on vascular branching hierarchy using the software Avizo 2020.2. DH significantly reduced median number of arteries (2,579 (8440) versus 576 (442), p = .017), artery numbers per arterial generation, mean total arterial volume (43.5 ± 8.4 vs. 19.9 ± 3.1 μl, p = .020) and mean total arterial cross‐sectional area (82.5 ± 2.3 vs. 28.2 ± 6.2 mm2, p =.036). Mean arterial radius was increased in DH kittens between the eighth and sixth branching generation and mean arterial length between the sixth and 28th branching generation. A DH in kittens resulted in threefold reduction in pulmonary arterial cross‐sectional area, primarily due to reduced arterial branching. Thus, the reduction in arterial cross‐sectional area could be a major contributor to pulmonary hypertension infants with CDH.
- 7 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (20) , 205002
Accurate measures of changes in regional lung air volumes from chest x-rays of small animals
Objective . To develop a robust technique for calculating regional volume changes within the lung from x-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). Approach . This technique is based on the change in transmitted x-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Main results . Lung air volumes calculated from x-ray intensity changes showed a strong correlation ( R 2 = 0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from x-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. Significance . This method is suitable for biomedical research studies,enabling quantitative regional measurement of relative lung air volumes at high temporal resolution, and shows great potential for future clinical application.
- 7 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (20) , 205002
Accurate measures of changes in regional lung air volumes from chest x-rays of small animals
Objective . To develop a robust technique for calculating regional volume changes within the lung from x-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). Approach . This technique is based on the change in transmitted x-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Main results . Lung air volumes calculated from x-ray intensity changes showed a strong correlation ( R 2 = 0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from x-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. Significance . This method is suitable for biomedical research studies,enabling quantitative regional measurement of relative lung air volumes at high temporal resolution, and shows great potential for future clinical application.
- Open Access
- 23 June 2022
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 10, 878536
Evaluating Clinical Outcomes and Physiological Perspectives in Studies Investigating Respiratory Support for Babies Born at Term With or at Risk of Transient Tachypnea: A Narrative Review
Respiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e., elective cesarean section) are at greater risk of developing respiratory distress due to elevated airway liquid volumes at birth. These babies are commonly diagnosed with transient tachypnea of the newborn (TTN) and historically treatments have mostly focused on enhancing airway liquid clearance pharmacologically or restricting fluid intake with limited success. Alternatively, a number of clinical studies have investigated the potential benefits of respiratory support in newborns with or at risk of TTN, but there is considerable heterogeneity in study designs and outcome measures. A literature search identified eight clinical studies investigating use of respiratory support on outcomes related to TTN in babies born at term. Study demographics including gestational age, mode of birth, antenatal corticosteroid exposure, TTN diagnosis, timing of intervention (prophylactic/interventional), respiratory support (type/interface/device/pressure), and study outcomes were compared. This narrative review provides an overview of factors within and between studies assessing respiratory support for preventing and/or treating TTN. In addition, we discuss the physiological understanding of how respiratory support aids lung function in newborns with elevated airway liquid volumes at birth. However, many questions remain regarding the timing of onset, pressure delivered, device/interface used and duration, and weaning of support. Future studies are required to address these gaps in knowledge to provide evidenced based recommendations for management of newborns with or at risk of TTN.
- 23 June 2022
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 10, 878536
Open AccessEvaluating Clinical Outcomes and Physiological Perspectives in Studies Investigating Respiratory Support for Babies Born at Term With or at Risk of Transient Tachypnea: A Narrative Review
Respiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e., elective cesarean section) are at greater risk of developing respiratory distress due to elevated airway liquid volumes at birth. These babies are commonly diagnosed with transient tachypnea of the newborn (TTN) and historically treatments have mostly focused on enhancing airway liquid clearance pharmacologically or restricting fluid intake with limited success. Alternatively, a number of clinical studies have investigated the potential benefits of respiratory support in newborns with or at risk of TTN, but there is considerable heterogeneity in study designs and outcome measures. A literature search identified eight clinical studies investigating use of respiratory support on outcomes related to TTN in babies born at term. Study demographics including gestational age, mode of birth, antenatal corticosteroid exposure, TTN diagnosis, timing of intervention (prophylactic/interventional), respiratory support (type/interface/device/pressure), and study outcomes were compared. This narrative review provides an overview of factors within and between studies assessing respiratory support for preventing and/or treating TTN. In addition, we discuss the physiological understanding of how respiratory support aids lung function in newborns with elevated airway liquid volumes at birth. However, many questions remain regarding the timing of onset, pressure delivered, device/interface used and duration, and weaning of support. Future studies are required to address these gaps in knowledge to provide evidenced based recommendations for management of newborns with or at risk of TTN.
- Open Access
Accurate measures of regional lung air volumes from chest X-rays of small animals
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
Open AccessAccurate measures of regional lung air volumes from chest X-rays of small animals
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
- 1 April 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 132 (4) , 1080-1090
Increased airway liquid volumes at birth impair cardiorespiratory function in preterm and near-term lambs
Respiratory distress is relatively common in infants born at or near-term, particularly in infants delivered following elective cesarean section. The pathophysiology underlying respiratory distress at term has largely been explained by a failure to clear airway liquid, but recent physiological evidence has indicated that it results from elevated airway liquid at the onset of air-breathing. We have investigated the effect of elevated airway liquid volumes at birth on cardiorespiratory function in preterm and near-term lambs. Preterm (130 ± 0 days gestation, term ∼147 days gestation; n = 12) and near-term (139 ± 1 days gestation; n = 13) lambs were instrumented (to measure blood pressure, blood flow, and blood gas status) and, at delivery, airway liquid volumes were adjusted to mimic levels expected following vaginal delivery (Controls; ∼7 mL/kg) or elective cesarean section with no labor (elevated liquid (EL); 37 mL/kg). Lambs were delivered, mechanically ventilated, and monitored for blood gas status, oxygenation, ventilator requirements, blood flows (carotid artery and pulmonary artery), and blood pressure during the first few hours of life. Preterm and near-term EL lambs had poorer gas exchange and required greater ventilatory support to maintain adequate oxygenation. Pulmonary blood flow was reduced and carotid artery blood flow, mean arterial blood pressure, and heart rate were reduced in EL near-term but not preterm lambs. These data provide further evidence that greater airway liquid volumes at birth adversely affect newborn cardiorespiratory function, with the effects being greater in near-term newborns. NEW & NOTEWORTHY We provide evidence for adverse effects of elevated airway liquid volumes at birth on pulmonary blood flow and gas exchange in both preterm and near-term lambs, although the effects were greatest in near-term newborns. Our study is an important step toward understanding the fundamental physiology underlying the cardiorespiratory morbidity associated with near-term newborns with elevated airway liquid volumes leading to respiratory distress soon after birth.
- 1 April 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 132 (4) , 1080-1090
Increased airway liquid volumes at birth impair cardiorespiratory function in preterm and near-term lambs
Respiratory distress is relatively common in infants born at or near-term, particularly in infants delivered following elective cesarean section. The pathophysiology underlying respiratory distress at term has largely been explained by a failure to clear airway liquid, but recent physiological evidence has indicated that it results from elevated airway liquid at the onset of air-breathing. We have investigated the effect of elevated airway liquid volumes at birth on cardiorespiratory function in preterm and near-term lambs. Preterm (130 ± 0 days gestation, term ∼147 days gestation; n = 12) and near-term (139 ± 1 days gestation; n = 13) lambs were instrumented (to measure blood pressure, blood flow, and blood gas status) and, at delivery, airway liquid volumes were adjusted to mimic levels expected following vaginal delivery (Controls; ∼7 mL/kg) or elective cesarean section with no labor (elevated liquid (EL); 37 mL/kg). Lambs were delivered, mechanically ventilated, and monitored for blood gas status, oxygenation, ventilator requirements, blood flows (carotid artery and pulmonary artery), and blood pressure during the first few hours of life. Preterm and near-term EL lambs had poorer gas exchange and required greater ventilatory support to maintain adequate oxygenation. Pulmonary blood flow was reduced and carotid artery blood flow, mean arterial blood pressure, and heart rate were reduced in EL near-term but not preterm lambs. These data provide further evidence that greater airway liquid volumes at birth adversely affect newborn cardiorespiratory function, with the effects being greater in near-term newborns. NEW & NOTEWORTHY We provide evidence for adverse effects of elevated airway liquid volumes at birth on pulmonary blood flow and gas exchange in both preterm and near-term lambs, although the effects were greatest in near-term newborns. Our study is an important step toward understanding the fundamental physiology underlying the cardiorespiratory morbidity associated with near-term newborns with elevated airway liquid volumes leading to respiratory distress soon after birth.
- 1 September 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 131 (3) , 997-1008
Increased end-expiratory pressures improve lung function in near-term newborn rabbits with elevated airway liquid volume at birth
Approximately 53% of near-term newborns admitted into intensive care, experience respiratory distress. These newborns are commonly delivered by caesarean section and have elevated airway liquid volumes at birth, which can cause respiratory morbidity. We investigated the effect of providing respiratory support with a positive end expiratory pressure (PEEP) of 8cmH2O on lung function in newborn rabbit kittens with elevated airway liquid volumes at birth.Near-term rabbits (30d; term=32d) with airway liquid volumes that corresponded to vaginal delivery (~7mL/kg, Control, n=11) or caesarean section (~37mL/kg; Elevated Liquid (EL), n=11) were mechanically ventilated (tidal volume=8mL/kg). The PEEP was changed after lung aeration from 0 to 8 to 0 cmH2O (Control, n=6; EL, n=6) and in a separate group of kittens, PEEP was changed after lung aeration from 8 to 0 to 8 cmH2O (Control, n=5; EL, n=5). Lung function (ventilator parameters, compliance, lung gas volumes and distribution of gas within the lung) was evaluated using plethysmography and synchrotron-based phase contrast X-ray imaging. EL kittens initially receiving 0 cmH2O PEEP had reduced functional residual capacities and lung compliance, requiring higher inflation pressures to aerate the lung compared to Control kittens. Commencing ventilation with 8 cmH2O PEEP mitigated the adverse effects of EL, increasing lung compliance, functional residual capacity and the uniformity and distribution of lung aeration, but did not normalize aeration of the distal airways. Respiratory support with PEEP supports lung function in near-term newborn rabbits with elevated airway liquid volumes at birth who are at greater risk of suffering respiratory distress.
- 1 September 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 131 (3) , 997-1008
Increased end-expiratory pressures improve lung function in near-term newborn rabbits with elevated airway liquid volume at birth
Approximately 53% of near-term newborns admitted into intensive care, experience respiratory distress. These newborns are commonly delivered by caesarean section and have elevated airway liquid volumes at birth, which can cause respiratory morbidity. We investigated the effect of providing respiratory support with a positive end expiratory pressure (PEEP) of 8cmH2O on lung function in newborn rabbit kittens with elevated airway liquid volumes at birth.Near-term rabbits (30d; term=32d) with airway liquid volumes that corresponded to vaginal delivery (~7mL/kg, Control, n=11) or caesarean section (~37mL/kg; Elevated Liquid (EL), n=11) were mechanically ventilated (tidal volume=8mL/kg). The PEEP was changed after lung aeration from 0 to 8 to 0 cmH2O (Control, n=6; EL, n=6) and in a separate group of kittens, PEEP was changed after lung aeration from 8 to 0 to 8 cmH2O (Control, n=5; EL, n=5). Lung function (ventilator parameters, compliance, lung gas volumes and distribution of gas within the lung) was evaluated using plethysmography and synchrotron-based phase contrast X-ray imaging. EL kittens initially receiving 0 cmH2O PEEP had reduced functional residual capacities and lung compliance, requiring higher inflation pressures to aerate the lung compared to Control kittens. Commencing ventilation with 8 cmH2O PEEP mitigated the adverse effects of EL, increasing lung compliance, functional residual capacity and the uniformity and distribution of lung aeration, but did not normalize aeration of the distal airways. Respiratory support with PEEP supports lung function in near-term newborn rabbits with elevated airway liquid volumes at birth who are at greater risk of suffering respiratory distress.
- 1 February 2021
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 57 (2) , 305-313
Placental gas exchange during amniotic carbon dioxide insufflation in sheep
Objective: Insufflation of the amniotic cavity with carbon dioxide (CO 2 ) is used clinically to improve visibility during complex fetoscopic surgery. Insufflation with heated, humidified CO 2 has recently been shown to reduce fetal hypercapnia and acidosis in sheep, compared with use of cold and dry CO 2 , but the underlying mechanisms are unclear. The aim of this study was to investigate whether differences in placental CO 2 and oxygen (O 2 ) exchange during insufflation with heated and humidified vs cold and dry CO 2 could explain these findings. Methods: Thirteen fetal lambs at 105 days of gestation (term, 146 days) were exteriorized partially, via a midline laparotomy and hysterotomy, and instrumented with an umbilical artery catheter, an umbilical vein catheter and a common umbilical vein flow probe. Arterial and venous catheters and flow probes were also inserted into the maternal uterine circulation. Six ewes were insufflated with cold, dry CO 2 (22°C; 0–5% humidity) and seven with heated, humidified CO 2 (40°C; 95–100% humidity) at 15 mmHg for 180 min. Blood‐flow recordings and paired arterial and venous blood gases were sampled from uterine and umbilical vessels. Rates of placental CO 2 and O 2 exchange were calculated. Results: After 180 min of insufflation, fetal survival was 33% (2/6) using cold, dry CO 2 and 71% (5/7) using heated, humidified CO 2 . By 120 min, fetuses insufflated with heated, humidified CO 2 had lower arterial CO 2 levels and higher arterial pH compared to those insufflated with cold, dry gas. Insufflation decreased significantly placental gas exchange in both groups, as measured by rates of both (i) fetal CO 2 clearance and O 2 uptake and (ii) maternal O 2 delivery and CO 2 uptake from the fetal compartment. Conclusions: Lower arterial CO 2 and higher pH levels in fetuses insufflated with heated and humidified, compared to cold and dry, CO 2 could not be explained by differences in placental gas exchange. Instead, heated and humidified insufflation appeared to reduce fetal CO 2 absorption from the uterus, supporting its use in preference to cold, dry CO 2 . © 2019 International Society of Ultrasound in Obstetrics and Gynecology
- 1 February 2021
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 57 (2) , 305-313
Placental gas exchange during amniotic carbon dioxide insufflation in sheep
Objective: Insufflation of the amniotic cavity with carbon dioxide (CO 2 ) is used clinically to improve visibility during complex fetoscopic surgery. Insufflation with heated, humidified CO 2 has recently been shown to reduce fetal hypercapnia and acidosis in sheep, compared with use of cold and dry CO 2 , but the underlying mechanisms are unclear. The aim of this study was to investigate whether differences in placental CO 2 and oxygen (O 2 ) exchange during insufflation with heated and humidified vs cold and dry CO 2 could explain these findings. Methods: Thirteen fetal lambs at 105 days of gestation (term, 146 days) were exteriorized partially, via a midline laparotomy and hysterotomy, and instrumented with an umbilical artery catheter, an umbilical vein catheter and a common umbilical vein flow probe. Arterial and venous catheters and flow probes were also inserted into the maternal uterine circulation. Six ewes were insufflated with cold, dry CO 2 (22°C; 0–5% humidity) and seven with heated, humidified CO 2 (40°C; 95–100% humidity) at 15 mmHg for 180 min. Blood‐flow recordings and paired arterial and venous blood gases were sampled from uterine and umbilical vessels. Rates of placental CO 2 and O 2 exchange were calculated. Results: After 180 min of insufflation, fetal survival was 33% (2/6) using cold, dry CO 2 and 71% (5/7) using heated, humidified CO 2 . By 120 min, fetuses insufflated with heated, humidified CO 2 had lower arterial CO 2 levels and higher arterial pH compared to those insufflated with cold, dry gas. Insufflation decreased significantly placental gas exchange in both groups, as measured by rates of both (i) fetal CO 2 clearance and O 2 uptake and (ii) maternal O 2 delivery and CO 2 uptake from the fetal compartment. Conclusions: Lower arterial CO 2 and higher pH levels in fetuses insufflated with heated and humidified, compared to cold and dry, CO 2 could not be explained by differences in placental gas exchange. Instead, heated and humidified insufflation appeared to reduce fetal CO 2 absorption from the uterus, supporting its use in preference to cold, dry CO 2 . © 2019 International Society of Ultrasound in Obstetrics and Gynecology
- 1 December 2020
- Published by Cambridge University Press (CUP) in Journal of Developmental Origins of Health and Disease
- Vol. 11 (6) , 543-544
DOHaD in the land down under: 11th World Congress 2019
- 1 December 2020
- Published by Cambridge University Press (CUP) in Journal of Developmental Origins of Health and Disease
- Vol. 11 (6) , 543-544
DOHaD in the land down under: 11th World Congress 2019
- Open Access
- 29 October 2020
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 8, 516698
Improving Newborn Respiratory Outcomes With a Sustained Inflation: A Systematic Narrative Review of Factors Regulating Outcome in Animal and Clinical Studies
Respiratory support is critically important for survival of newborns who fail to breathe spontaneously at birth. Although there is no internationally accepted definition of a sustained inflation (SI), it has commonly been defined as a positive pressure inflation designed to establish functional residual capacity and applied over a longer time period than normally used in standard respiratory support (SRS). Outcomes vary distinctly between studies and to date there has been no comprehensive investigation of differences in SI approach and study outcome in both pre-clinical and clinical studies. A systematic literature search was performed and, after screening, identified 17 animal studies and 17 clinical studies evaluating use of a SI in newborns compared to SRS during neonatal resuscitation. Study demographics including gestational age, SI parameters (length, repetitions, pressure, method of delivery) and study outcomes were compared. Animal studies provide mechanistic understanding of a SI on the physiology underpinning the cardiorespiratory transition at birth. In clinical studies, there is considerable difference in study quality, delivery of SIs (number, pressure, length) and timing of primary outcome evaluation which limits direct comparison between studies. The largest difference is method of delivery, where the role of a SI has been observed in intubated animals, as the inflation pressure is directly applied to the lung, bypassing the obstructed upper airway in an apnoeic state. This highlights a potential limitation in clinical use of a SI applied non-invasively. Further research is required to identify if a SI may have greater benefits in subpopulations of newborns.
- 29 October 2020
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 8, 516698
Open AccessImproving Newborn Respiratory Outcomes With a Sustained Inflation: A Systematic Narrative Review of Factors Regulating Outcome in Animal and Clinical Studies
Respiratory support is critically important for survival of newborns who fail to breathe spontaneously at birth. Although there is no internationally accepted definition of a sustained inflation (SI), it has commonly been defined as a positive pressure inflation designed to establish functional residual capacity and applied over a longer time period than normally used in standard respiratory support (SRS). Outcomes vary distinctly between studies and to date there has been no comprehensive investigation of differences in SI approach and study outcome in both pre-clinical and clinical studies. A systematic literature search was performed and, after screening, identified 17 animal studies and 17 clinical studies evaluating use of a SI in newborns compared to SRS during neonatal resuscitation. Study demographics including gestational age, SI parameters (length, repetitions, pressure, method of delivery) and study outcomes were compared. Animal studies provide mechanistic understanding of a SI on the physiology underpinning the cardiorespiratory transition at birth. In clinical studies, there is considerable difference in study quality, delivery of SIs (number, pressure, length) and timing of primary outcome evaluation which limits direct comparison between studies. The largest difference is method of delivery, where the role of a SI has been observed in intubated animals, as the inflation pressure is directly applied to the lung, bypassing the obstructed upper airway in an apnoeic state. This highlights a potential limitation in clinical use of a SI applied non-invasively. Further research is required to identify if a SI may have greater benefits in subpopulations of newborns.