    A 3D phantom for EIT printed in a single part

    by Andrew Creegan, Bryan Ruddy, Andrew Taberner

    Electrical Impedance Tomography (EIT) is a medical imaging technology that uses electrical current to image the body. Imaging phantoms which act as a well-characterized reference objects are useful for the study of EIT and calibration of EIT devices. A proof of concept of a new type of 3D printed phantom for EIT was recently introduced, and this paper seeks to fully realize this concept by printing a phantom with three-dimensional geometry in a single part and demonstrating how it can be used for the study of EIT. The 3D printed phantoms are printed all-in-one, with internal regions of differing infill density which correspond to differing conductivity, the property imaged by EIT. Three prototype phantoms were printed, including one containing the 3D geometry of the surface of a pair of human lungs. A technique was demonstrated to calibrate an EIT device using measurements taken from a printed phantom, giving similar results to traditional calibration. Images of slices through the 3D phantoms were generated from physical measurements, and were comparable to simulations, giving evidence that the phantoms were sufficiently well characterized. Overall, this is an accessible and effective method for creating phantoms for EIT, and we encourage its wider adoption.

  • Open Access

    Vacuum-Assisted Needle-Free Capillary Blood Sampling

    by Michael Hoffman, James McKeage, Bryan Ruddy, Poul Nielsen, Andrew Taberner

    Background: Poor glycemic management persists among people practicing insulin therapy in relation to type 1 and 2 diabetes despite a clear relationship with negative health outcomes. Skin penetration by jet injection has recently been shown as a viable method for inducing blood release from fingertips. This study examines the use of vacuum to enhance the volume of blood released and quantifies any dilution of the collected blood. Methods: A single-blind crossover study involving 15 participants, each receiving four different interventions, was conducted wherein each participant served as their own control. Each participant experienced fingertip lancing and fingertip jet injection, both with and without applied vacuum. Participants were divided into three equal groups to explore different vacuum pressures. Results: This study found that glucose concentration in blood collected under vacuum following jet injection and lancing were equivalent. We found that applying a 40 kPa vacuum following jet injection produced a 35-fold increase in the collected volume. We determined the limited extent to which the injectate dilutes blood collected following jet injection. The mean dilution of blood collected by jet injection was 5.5%. We show that jet injection is as acceptable to patients as lancing, while being equally suited for conducting glucose measurements. Conclusions: Vacuum significantly enhances the volume of capillary blood released from the fingertip without any difference in pain. The blood collected by jet injection with vacuum is equivalent to that from lancing for glucose measurement purposes.


  • Case study of user experience‐driven design in a new local anaesthetic dentistry jet injection device

    by Kate Weatherly, Paul Brunton, Carolina Loch, James W. McKeage, Bryan P. Ruddy, Andrew J. Taberner, David E. White

    This case study explored how human‐centred design methodologies can improve clinician experience and reduce patient treatment anxiety in the application of a new dental local anaesthetic jet‐injection system. An initial embodiment of the prototype injector, dubbed the ‘Kiwi’ injector, was developed to better understand the user experience during dental‐injection procedures. Further design development was undertaken in two distinct phases. Stage one entailed the initial non‐functional Kiwi injector model being used as a design probe to explore clinician views on its aesthetics and ergonomics. The second stage explored the clinician and patient experiences of the functional Kiwi Injector while administering a local anaesthetic to the patient. Stage one findings highlighted clinician satisfaction with the aesthetics of the non‐functional prototype device but expressed the desire to make the device smaller. Stage two clinical study results highlighted an issue with the functional jet injector configuration, where the participating dental clinicians speculated that a greater bend in the wand and change of trigger position would significantly improve the Kiwi injector ergonomic performance. This research has demonstrated the benefits of applying a structured and staged human‐centred user experience design process to inform the design of a new dental anaesthetic delivery device.


  • Jet injection needle-free dental anaesthesia: Initial findings

    by Paul A. Brunton, Mitten McLean, Senthilkumar Vedagiri, James McKeage, Bryan Ruddy, Kate Weatherly, David White, Andrew Taberner, Carolina Loch


  • Shoulder Joint Stiffness in a Functional Posture at Various Levels of Muscle Activation

    by Yahya Z. Yahya, Ian W. Hunter, Thor F. Besier, Andrew J. Taberner, Bryan P. Ruddy

    Objective: In this study, we present a method to quantify the mechanics of the shoulder joint in a functional posture, in two degrees of freedom: internal/external rotation and horizontal abduction/adduction. Methods: We performed experiments on 15 healthy participants using a custom perturbation robot. Perturbations were applied in internal/external rotation and horizontal abduction/adduction, whilst participants applied varying levels of joint torque. System identification techniques were used to quantify the mechanical properties of the shoulder joint at various levels of muscle contraction, including; stiffness, viscous damping, and inertia parameters, natural frequency, and damping parameter. We compared the shoulder mechanical properties between dominant and non-dominant limbs. Results: The mean stiffness increased 4.8 times in external rotation, and 6.25 times in internal rotation as a result of contraction to 8 Nm. It increased 2.8 times in adduction and 4.6 times in abduction as a result of contraction to 16 Nm. The mean viscous damping increased 3 times in external rotation, 2.8 times in internal rotation as a result of contraction to 8 Nm. It increased 1.6 times in adduction and 2.25 times in abduction as a result of contraction to 16 Nm. Conclusion: Joint stiffness, viscous damping and natural frequency all increased with the level of shoulder contraction torque, whereas the damping parameter remained unchanged. No differences were observed between dominant and non-dominant limbs. Significance: We have presented a method to characterize the mechanical properties of the shoulder complex during various activation states, which has application as a diagnostic and assessment tool for shoulder pathology.


  • Open Access

    Jet-Induced Tissue Disruption for Blood Release

    by Jiali Xu, James W. McKeage, Bryan P. Ruddy, Poul M. F. Nielsen, Andrew J. Taberner

    Objective: Needle-free jet injection is a drug delivery technique that uses the momentum of the fluid drug to break through the skin. This technique has recently also been applied to blood release, aiming to collect samples from capillaries in the skin without needing a lancet prick. This work provides new information about the wound geometry and tissue disruption caused by shallow jet injection with circular-shaped and slot-shaped jets. Methods: We use histological analysis to compare the disruption of tissue, including blood vessels, caused by lancet-pricking and jet injection with a circular-shaped jet and a lancet-inspired slot-shaped jet. Results: Intradermal injection into porcine skin using a slot-shaped jet disrupted more vascular endothelium in the tissue than a circular-shaped jet and did so at a smaller penetration depth with smaller wound volume. Our results suggest that shallow jet injections may have the potential to release more capillary blood than a lancet prick. Conclusion: These findings demonstrate that a reversible jet injector might be used in diabetes management as a device to release and collect blood samples, in addition to being used to deliver insulin. Significance: Tissue disruption is crucial to consider when using jet injection to deliver drugs and release capillary blood.


  • Open Access

    Controllable Jet Injection of Dental Local Anaesthetic

    by James W. Mckeage, Carolina Loch, Johann Zwirner, Niels Hammer, David E. White, Bryan P. Ruddy, Paul A. Brunton, Andrew J. Taberner

    Objective: Fear of dental procedures is a common barrier to effective dental care. A promising technique to overcome dental anxiety is needle-free jet injection, which involves delivering local anaesthetic as a high-speed jet capable of penetrating the oral mucosa without a needle. Previous efforts have used loud, uncontrolled injectors designed for transdermal delivery that have failed to achieve significant uptake in dental practice. Methods: In this work, we present and validate a controllable jet injection device driven by a silent electric motor for the delivery of dental local anaesthetic. The injector includes a novel tubular attachment at its distal end, which allows the delivery to be performed comfortably throughout the mouth. The expected pressure loss resulting from the use of this attachment is analysed. This analysis predicted that a 75 mm long tubular attachment of 0.53 mm radius would result in negligible pressure loss. To validate delivery in human tissue, the injection system was used to perform 18 injections into the mouths of two Thiel-embalmed human cadavers. These injections were visualised using cone-beam computed tomography (CBCT). Results: Benchtop testing of the prototype injector verified the expected pressure loss along the attachment. The CBCT scans demonstrated that the fluid was successfully delivered to the desired locations, adjacent to the root apex of the teeth, at every injection site. Conclusion: These outcomes validate the performance of this novel needle-free injector, demonstrating its potential as a tool to reduce dental anxiety. Clinical and Translational Impact Statement- Our controllable jet injection device overcomes key limitations associated with previous attempts to deliver dental local anaesthetic needle-free. This could greatly reduce barriers to effective dental care.


  • Design of a Xenia Coral Robot Using a High-Stroke Compliant Linear Electromagnetic Actuator

    by Noah Kohls, Ibrahim Abdeally, Bryan P. Ruddy, Yi Chen Mazumdar

    Electromagnetic actuators provide fast speed, large forces, high strokes, and wide bandwidths. Most designs, however, are constructed from rigid components, making these benefits inaccessible for many soft robotics applications. In this work, we develop a new soft electromagnetic linear actuator using liquid gallium–indium for the conductor and neodymium–iron–boron and polymer composites for the permanent magnet. When combined in a solenoid configuration, high strokes can be generated using entirely soft components. To emulate the pulsing motion of Xenia coral arms, we develop an additional soft flexure system that converts the linear translation to rotary motion. The design and fabrication of the electromagnetic actuator and compliant flexure are first described. Models for the magnetic forces and the joint kinematics are then developed and compared with the experimental results. Finally, the robot dynamics are analyzed using stochastic system identification techniques. Results show that the compliant actuator is able to achieve an 18 mm stroke, allowing the soft arms to bend up to 120 deg. This further enables the tips of the arms to traverse an arc length of 42 mm. Bandwidths up to 30 Hz were also observed. While this article focuses on emulating a biological system, this highly deformable actuator design can also be utilized for fully soft grasping or wearables applications.


  • Spatially resolved diffuse imaging for high‐speed depth estimation of jet injection

    by Kieran A. Brennan, Bryan P. Ruddy, Poul M. F. Nielsen, Andrew J. Taberner

    We investigate the use of spatially resolved diffuse imaging to track a fluid jet delivered at high speed into skin tissue. A jet injector with a short needle to deliver drugs beneath the dermis, is modified to incorporate a laser beam into the jet, which is ejected into ex vivo porcine tissue. The diffuse light emitted from the side and top of the tissue sample is recorded using high‐speed videography. Similar experiments, using a depth‐controlled fiber optic source, generate a reference dataset. The side light distribution is related to source depth for the controlled‐source experiments and used to track the effective source depth of the injections. Postinjection X‐ray images show agreement between the jet penetration and ultimate light source depth. The surface light intensity profile is parameterized with a single parameter and an exponential function is used to relate this parameter to source depth for the controlled‐source data. This empirical model is then used to estimate the effective source depth from the surface profile of the injection experiments. The depth estimates for injections into fat remain close to the side depth estimates, with a root‐mean‐square error of 1.1 mm, up to a source depth of 8 mm.


  • Classification of diffuse light emission profiles for distinguishing skin layer penetration of a needle-free jet injection

    by Kieran A. Brennan, Bryan P. Ruddy, Poul M. F. Nielsen, Andrew J. Taberner

    In this work, a system is developed for tracking the skin layer to which a needle-free jet injection of fluid has penetrated by incorporating a laser beam into the jet, and measuring the diffuse light emitted from skin tissue. Monitoring the injection in this way offers the ability to improve the reliability of drug delivery with this transdermal delivery method. A laser beam, axially aligned with a jet of fluid, created a distribution of diffuse light around the injection site that varied as the injection progressed. High-speed videography was used to capture the diffuse light emission from laser-coupled jet injections into samples of porcine skin, fat, and muscle. The injection produced a distribution of diffuse light around the injection site that varied as the injection descended. A classifier, trained to distinguish whether the light source was located in the fat or muscle from surface intensity profile measurements, correctly identified the injected layer in ${97.2}{\%}$ of the cases when cross-examined against estimates using the light distribution emitted from the side of the sample.