Troy Wanandy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Troy Wanandy has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Michael David Wiese
Centre for Pharmaceutical Innovation, Clinical & Health Sciences University of South Australia, Adelaide, SA 5001, Australia
5 shared publications - Simon Alfred Handley
Royal Hobart Hospital
4 shared publications Simon A. Handley
College of Health and Medicine, University of Tasmania, Hobart, Australia
3 shared publicationsWun Yee Lau
Department of Clinical Immunology and Allergy, incorporating the Jack Jumper Allergy Program, Royal Hobart Hospital, Hobart, Australia
3 shared publications- Benoit T.B. Cotton
Tasmanian Jack Jumper Allergy Program, Royal Hobart Hospital, Hobart, Tasmania, Australia
2 shared publications - Cesar D. Tovar Lopez
Tasmanian Jack Jumper Allergy Program, Royal Hobart Hospital, Hobart, Tasmania, Australia; Menzies Institute for Medical Research, University of Tasmania, Hobart, Tasmania, Australia
2 shared publications
Latest Publications
- 23 September 2026
- Published by Wiley in Medical Journal of Australia
- Vol. 224 (9) , e70306
Intranasal Adrenaline Use for the Management of Insect Venom‐Induced Anaphylaxis
Intranasal adrenaline has recently become available in Australia as a needle‐free alternative to adrenaline autoinjectors for anaphylaxis management. Intranasal adrenaline may be particularly suitable for patients with barriers to adrenaline autoinjector usage, such as needle aversion or poor compliance with autoinjector carriage. However, although the data supporting real‐world efficacy of intranasal adrenaline for anaphylaxis are growing, there is no published evidence confirming its efficacy in insect venom anaphylaxis. We report three cases of intranasal adrenaline (neffy, CSL Seqirus, Victoria, Australia) used to treat insect venom‐induced anaphylaxis. Clinicians should be aware of the availability and current level of evidence for intranasal adrenaline for anaphylaxis management.
- 23 September 2026
- Published by Wiley in Medical Journal of Australia
- Vol. 224 (9) , e70306
Intranasal Adrenaline Use for the Management of Insect Venom‐Induced Anaphylaxis
Intranasal adrenaline has recently become available in Australia as a needle‐free alternative to adrenaline autoinjectors for anaphylaxis management. Intranasal adrenaline may be particularly suitable for patients with barriers to adrenaline autoinjector usage, such as needle aversion or poor compliance with autoinjector carriage. However, although the data supporting real‐world efficacy of intranasal adrenaline for anaphylaxis are growing, there is no published evidence confirming its efficacy in insect venom anaphylaxis. We report three cases of intranasal adrenaline (neffy, CSL Seqirus, Victoria, Australia) used to treat insect venom‐induced anaphylaxis. Clinicians should be aware of the availability and current level of evidence for intranasal adrenaline for anaphylaxis management.
- 19 June 2026
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 14 (10) , 2408-2410
Acalabrutinib for long-term prevention of recurrent idiopathic anaphylaxis
- 19 June 2026
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 14 (10) , 2408-2410
Acalabrutinib for long-term prevention of recurrent idiopathic anaphylaxis
- Open Access
- 8 May 2026
- Published by Elsevier in Journal of Allergy and Clinical Immunology: Global
- Vol. 5 (4) , 100732
Stability of proton pump inhibitors for use in hypersensitivity evaluation
- 8 May 2026
- Published by Elsevier in Journal of Allergy and Clinical Immunology: Global
- Vol. 5 (4) , 100732
Open AccessStability of proton pump inhibitors for use in hypersensitivity evaluation
- 29 April 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 62 (6) , 505-509
Performance of the Binding Site cerebrospinal fluid kappa free light chains assay
Background: Measurement of cerebrospinal fluid (CSF) kappa free light chains (KFLCs) for the detection of intrathecal immunoglobulin synthesis has generated interest as an alternative to CSF oligoclonal bands due to its rapid turnaround time and ability to automate the assay. A turbidimetric immunoassay – Freelite Mx, is available from the Binding Site, but published data on performance is scant. Therefore, we undertook a multicentre sample comparison and investigated reagent lot-to-lot-variation (LTLV). Methods: Intra-/inter-assay accuracy and imprecision of the Freelite Mx assay on the Binding Site Optilite analyser was assessed. Twenty paired CSF/serum samples were sent to three laboratories within Australia for the measurement of CSF/serum KFLC/albumin and concentrations compared using the Kruskal–Wallis test, Spearman’s rank (rs), and Passing-Bablok analysis. Lot-to-lot-variation between three reagent lots was undertaken by analysis of 20 CSF samples. Results: Intra- and inter-assay imprecision was ≤4.4 and ≤4.1%, respectively. There was a good correlation (rs = ≥0.98) between sites for the measured CSF KFLC concentration, and no significant difference in the median concentration measured between sites (3.31, 2.78, and 3.48 mg/L, P = .98). The median bias between reagent lots was <4%, the intercept of the regression between lots was between −0.02 and 0.06 mg/L, and the slope ranged from 0.96 to 1.07. Conclusion: Overall, there was a good agreement in CSF KFLC concentrations among laboratories, and LTLV was deemed acceptable. Ascertaining biological variability of CSF KFLCs and the participation of laboratories in quality assurance schemes would assist with harmonisation.
- 29 April 2025
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 62 (6) , 505-509
Performance of the Binding Site cerebrospinal fluid kappa free light chains assay
Background: Measurement of cerebrospinal fluid (CSF) kappa free light chains (KFLCs) for the detection of intrathecal immunoglobulin synthesis has generated interest as an alternative to CSF oligoclonal bands due to its rapid turnaround time and ability to automate the assay. A turbidimetric immunoassay – Freelite Mx, is available from the Binding Site, but published data on performance is scant. Therefore, we undertook a multicentre sample comparison and investigated reagent lot-to-lot-variation (LTLV). Methods: Intra-/inter-assay accuracy and imprecision of the Freelite Mx assay on the Binding Site Optilite analyser was assessed. Twenty paired CSF/serum samples were sent to three laboratories within Australia for the measurement of CSF/serum KFLC/albumin and concentrations compared using the Kruskal–Wallis test, Spearman’s rank (rs), and Passing-Bablok analysis. Lot-to-lot-variation between three reagent lots was undertaken by analysis of 20 CSF samples. Results: Intra- and inter-assay imprecision was ≤4.4 and ≤4.1%, respectively. There was a good correlation (rs = ≥0.98) between sites for the measured CSF KFLC concentration, and no significant difference in the median concentration measured between sites (3.31, 2.78, and 3.48 mg/L, P = .98). The median bias between reagent lots was <4%, the intercept of the regression between lots was between −0.02 and 0.06 mg/L, and the slope ranged from 0.96 to 1.07. Conclusion: Overall, there was a good agreement in CSF KFLC concentrations among laboratories, and LTLV was deemed acceptable. Ascertaining biological variability of CSF KFLCs and the participation of laboratories in quality assurance schemes would assist with harmonisation.
- 6 November 2024
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 13 (2) , 343-352
Stability of Antibiotics for Use in the Testing of Immediate Drug Allergy Reactions
- 6 November 2024
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 13 (2) , 343-352
Stability of Antibiotics for Use in the Testing of Immediate Drug Allergy Reactions
- 26 July 2024
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 12 (10) , 2877-2880.e4
Leech-bite induced anaphylaxis with or without Hymenoptera venom sensitization
- 26 July 2024
- Published by Elsevier in The Journal of Allergy and Clinical Immunology: In Practice
- Vol. 12 (10) , 2877-2880.e4
Leech-bite induced anaphylaxis with or without Hymenoptera venom sensitization
- Open Access
- 26 March 2024
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 9 (4) , 69
The Human Health Impacts of the Red Imported Fire Ant in the Western Pacific Region Context: A Narrative Review
Background: The red imported fire ant (RIFA) is one of the world’s most destructive invasive species. RIFA stings are painful and can lead to allergic reactions, including life-threatening anaphylaxis, yet health impacts remain inadequately defined. Methods: We searched MEDLINE (Ovid) and Google Scholar (grey literature) from inception until 20 September 2023 for articles in English using search terms related to red imported fire ants and allergies, including anaphylaxis. Results: Approximately a third of the population in RIFA-infested areas are stung each year. The most frequent reaction is a sterile 1–2 mm pseudo pustule on the skin. Approximately 20% of stings cause a large local reaction and between about 0.5% and 2% stings cause a systemic allergic reaction which can range from skin symptoms to life-threatening anaphylaxis. Local biodiversity is also significantly disrupted by invading RIFA and may lead to complex adverse effects on human health, from agriculture losses to expanded ranges for pathogen vectors. Conclusions: The potential for red imported fire ants to establish themselves as an invasive species in the Western Pacific presents a substantial and costly health issue. Successful eradication and surveillance programs, to identify and eradicate new incursions, would avoid substantial health impacts and costs.
- 26 March 2024
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 9 (4) , 69
Open AccessThe Human Health Impacts of the Red Imported Fire Ant in the Western Pacific Region Context: A Narrative Review
Background: The red imported fire ant (RIFA) is one of the world’s most destructive invasive species. RIFA stings are painful and can lead to allergic reactions, including life-threatening anaphylaxis, yet health impacts remain inadequately defined. Methods: We searched MEDLINE (Ovid) and Google Scholar (grey literature) from inception until 20 September 2023 for articles in English using search terms related to red imported fire ants and allergies, including anaphylaxis. Results: Approximately a third of the population in RIFA-infested areas are stung each year. The most frequent reaction is a sterile 1–2 mm pseudo pustule on the skin. Approximately 20% of stings cause a large local reaction and between about 0.5% and 2% stings cause a systemic allergic reaction which can range from skin symptoms to life-threatening anaphylaxis. Local biodiversity is also significantly disrupted by invading RIFA and may lead to complex adverse effects on human health, from agriculture losses to expanded ranges for pathogen vectors. Conclusions: The potential for red imported fire ants to establish themselves as an invasive species in the Western Pacific presents a substantial and costly health issue. Successful eradication and surveillance programs, to identify and eradicate new incursions, would avoid substantial health impacts and costs.
- 27 December 2023
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 61 (2) , 157-158
Urine copper by colorimetry
- 27 December 2023
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 61 (2) , 157-158
Urine copper by colorimetry
- 19 October 2023
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 61 (3) , 182-194
Validation of the Randox colorimetric assays for serum copper and zinc
Background: Serum copper and zinc are measured to assess deficiency and toxicity. Atomic absorption spectrophotometry and mass spectrometry methods are expensive and require highly trained staff. Colorimetric assays are available from Randox which are inexpensive and can be automated. We validated serum copper and zinc colorimetric assays on the Binding Site Optilite analyser including comparison with flame atomic absorption spectrophotometry (FAAS) and inductively coupled plasma-mass spectrometry (ICP-MS). Methods: Accuracy, imprecision, lower limit of quantitation, and linearity were ascertained. The impact of triglycerides, bilirubin, nickel, and iron on assay performance was also investigated. Comparison of results from colorimetric analysis of patient and external quality assurance samples with those obtained by FAAS and ICP-MS was undertaken. Results: Intra-, and inter-assay imprecision was <9%. Serum copper and zinc assays were linear between 1.8–35.6 and 2.3–45.7 µmol/L, respectively. Agreement was good between colorimetry and FAAS (intercept = -0.7, slope = 1.04) and ICP-MS (intercept = 0.6, slope = 0.99) for serum copper in patients’ samples. For serum zinc, agreement was poor between colorimetry and FAAS (intercept = 2.2, slope = 0.87) and ICP-MS (intercept = 1.9, slope = 0.98) in patients’ samples. There was a poor concordance in assessment of hypozincaemia between colorimetry and FAAS/ICP-MS. Conclusion: The Randox colorimetric assay for serum copper on the Optilite is simple to perform, has a short analysis time, and measured concentrations compare well with FAAS and ICP-MS. Due to poor agreement with FAAS and ICP-MS, colorimetry is not suitable for the measurement of serum zinc.
- 19 October 2023
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 61 (3) , 182-194
Validation of the Randox colorimetric assays for serum copper and zinc
Background: Serum copper and zinc are measured to assess deficiency and toxicity. Atomic absorption spectrophotometry and mass spectrometry methods are expensive and require highly trained staff. Colorimetric assays are available from Randox which are inexpensive and can be automated. We validated serum copper and zinc colorimetric assays on the Binding Site Optilite analyser including comparison with flame atomic absorption spectrophotometry (FAAS) and inductively coupled plasma-mass spectrometry (ICP-MS). Methods: Accuracy, imprecision, lower limit of quantitation, and linearity were ascertained. The impact of triglycerides, bilirubin, nickel, and iron on assay performance was also investigated. Comparison of results from colorimetric analysis of patient and external quality assurance samples with those obtained by FAAS and ICP-MS was undertaken. Results: Intra-, and inter-assay imprecision was <9%. Serum copper and zinc assays were linear between 1.8–35.6 and 2.3–45.7 µmol/L, respectively. Agreement was good between colorimetry and FAAS (intercept = -0.7, slope = 1.04) and ICP-MS (intercept = 0.6, slope = 0.99) for serum copper in patients’ samples. For serum zinc, agreement was poor between colorimetry and FAAS (intercept = 2.2, slope = 0.87) and ICP-MS (intercept = 1.9, slope = 0.98) in patients’ samples. There was a poor concordance in assessment of hypozincaemia between colorimetry and FAAS/ICP-MS. Conclusion: The Randox colorimetric assay for serum copper on the Optilite is simple to perform, has a short analysis time, and measured concentrations compare well with FAAS and ICP-MS. Due to poor agreement with FAAS and ICP-MS, colorimetry is not suitable for the measurement of serum zinc.