LPLucila Piasecki

Lucila Piasecki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lucila Piasecki has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 3D prototyped macro‐models as educational aid for teaching endodontic access in preclinical training: Assessment of students' learning experience, confidence and performance

    by Lucila Piasecki, Kayla Schwartz, Charlene Tsou, Praveen Arany, Mohini Ratakonda, Monica Romero, Jorge Vera, Kallyane Navarrete, Everdan Carneiro

    Aim: This study evaluated the effectiveness of three‐dimensional prototyped macro‐models (3DPMM) as an educational aid for teaching endodontic access to dental students. Methodology: A total of 72 students were randomly assigned to three groups ( n = 24) and participated in study sessions with 3DPMM at different stages: before, during (intermediate) or after performing laboratory projects. The timing of the 3DPMM study sessions rotated across groups for different tooth types (anterior, premolar and molar). Each student performed endodontic access on nine teeth (four anterior, three premolars and two molars). Students completed a questionnaire evaluating their learning experience and confidence. Endodontic access projects were graded by masked instructors, and the data were statistically analysed ( α = 0.05). Results: Students rated their learning experience with the 3DPMM positively, regardless of their differences based on group assignment, tooth type or timing of the study session ( p > .05). Procedural errors were observed in 47% of the teeth, with 35.6% exhibiting one error and 11.4% exhibiting two errors. The most common errors included gouging (26.6%) and oversized access cavities (23.5%). Students who completed endodontic access before using the 3DPMM had a significantly higher frequency of multiple errors, oversized access cavities and retained pulp chamber roof ( p < .05). Approximately 60% of participants reported increased confidence after using the models, regardless of group assignment, tooth type or study session timing ( p > .05). Conclusion: The findings suggest that integrating 3DPMM enhanced students' understanding of internal tooth anatomy, increased their confidence and reduced procedural errors. Students appreciated the hands‐on, interactive learning experience offered by the models, reinforcing the value of innovative educational tools in endodontic training.


  • Open Access

    Morphometric micro-CT study of contralateral mandibular incisors

    by Usame Sevgi, Gaute Floer Johnsen, Badra Hussain, Lucila Piasecki, Liebert Parreiras Nogueira, Håvard Jostein Haugen

    Objectives: This study aimed to determine the degree of similarity and symmetry in the anatomy of contralateral mandibular incisors. Three-dimensional (3D) models of extracted teeth were obtained from microtomography (micro-CT) scans. Qualitative and quantitative assessments of the morphology and comparison of contralateral pairs were made. The null hypothesis was that contralateral mandibular incisors could not be considered identical in simple morphometric measurements. Methods: Sixty pairs of mandibular incisors were extracted from 30 patients and scanned with micro-CT. Virtual models of the cemento-enamel junction to the root apex were rendered. Parameters such as length, canal width, dentinal thicknesses, tortuosity, centerline length, accessory canals, root canal configurations, and root canal orifice cross-sections were used to compare the teeth. Width and thickness comparisons between paired teeth in the same individual were made by paired t-test (Wilcoxon signed-rank test for variables not normally distributed). An online randomization tool generated randomized pairs (independent of the individual/patient). Subsequently, an unpaired t-test (or Mann–Whitney U test for non-normally distributed parameters) and a correlation analysis were conducted. Canal configurations were classified according to preexisting classification schemes. The number and location of accessory canals and apical foramina were registered and compared. Results: Utilizing advanced imaging techniques and quantitative analyses, our study establishes that contralateral mandibular incisors exhibit a remarkable degree of symmetry in multiple morphological parameters, including length, canal width, and dentinal thicknesses. The apical third showed a high degree of inter-variability for the contralateral pairs. The rigorous statistical analysis of the normalized parameters by Z-score showed no statistically significant differences between the contralateral mandibular incisors. Comparisons between central and lateral teeth revealed differences in root length but no significant disparity in the distribution of accessory canals. Central teeth, on average, were longer, while accessory canals were distributed relatively evenly between central and lateral teeth. Conclusions: The findings of this study further establish the significant similarities between contralateral mandibular incisors, reinforcing their suitability as a reliable substrate for root canal comparison studies. Clinical relevance: The absence of statistically significant differences between contralateral pairs in normalized parameters underscores their potential as a reliable reference point for root canal comparison studies in clinical dentistry. Furthermore, our findings emphasize the importance of individualized treatment planning, considering the natural symmetry in mandibular incisors to enhance clinical decision-making. This research contributes valuable insights to the field of endodontics, offering a standardized approach to sample selection and enriching the understanding of dental anatomy.


  • Variations in the morphology of apical constriction affecting electronic readings: An in vitro investigation using 3D‐printed tooth models

    by Juhee Nam, Lucila Piasecki, Doun Kwak, Jung Hwa Hong, Il‐Young Jung, Sung‐Ho Park, Sin‐Yeon Cho


  • Open Access

    Assessment of the Root Canal Similarity in Contralateral Mandibular Incisors

    by Gaute Floer Johnsen, Håvard Haugen, Liebert Parreiras Nogueira, Usame Sevgi, Ashley Mae Jimenez, Joseph T. DeLuca, Ryan Mancuso, Lucila Piasecki


  • Micro-CT evaluation of four final irrigation protocols on hard-tissue debris removal from mesial roots of mandibular molars containing isthmus

    by Bianca Marques de Mattos de Araujo, Alessandra Timponi Goes Cruz, Lucila Piasecki, Mariel Webber, Everdan Carneiro, Vânia Portela Ditzel Westphalen, Ulisses Xavier da Silva Neto

    Objectives To evaluate by means of microcomputed tomography (micro-CT), the efficacy of four final irrigation protocols in the removal of hard-tissue debris (HTD) in mesial roots of mandibular molars containing isthmus. Materials and methods Forty standardized mesial roots of extracted mandibular molars presenting isthmus were selected. The root canals were prepared and randomly divided into 4 groups (n = 10): EA, EndoActivator (Dentsply Sirona); EC, Easy Clean (Easy Dental Equipment, Belo Horizonte, Brazil); XPF, XP-Endo Finisher (FKG Dentaire, La Chaus-de Fonds, Switzerland); and PUI, passive ultrasonic irrigation using Irrisafe tip (Satelec Acteon, Merignac, France). Each final irrigation protocol was performed in two cycles (60 s), using, respectively, 2.5% sodium hypochlorite and 17% EDTA. Micro-CT scans were obtained pre-operatory, post-preparation, and post-irrigation. The percentage of HTD reduction was calculated. Data was analyzed statistically (ANOVA and Kruskal–Wallis, significance set at 5%). Results The percentage of HTD reduction was greatest for the XPF group (77.92%), followed by EA (62.92%), PUI (47.48%), and EC (32.65%). Statistical differences (p < .05) were found between XPF and EC only. A significant difference (p < .05) was found between XPF and EC in all thirds and between PUI and EC in the middle third. Conclusions XPF, EA, and PUI were similarly effective in HTD reduction. However, none of the evaluated protocols was able to completely remove all the debris. Clinical relevance Final irrigation protocols aim to clean the canal complexities that are not addressed by the shaping procedures. Micro-CT allowed to assess the removal of hard-tissue debris in the isthmus and canals of mandibular molars.


  • A laboratory study of the accuracy of three electronic apex locators: influence of embedding media and radiographic assessment of the electronic apical limit

    by M. F. Iparraguirre Nuñovero, L. Piasecki, A. V. K. Segato, V. P. D. Westphalen, U. X. Silva Neto, E. Carneiro

    Aim: To evaluate several factors that might interfere with the use of electronic root canal length measurement devices (ERCLMDs) in a laboratory setting, including two different embedding media (alginate and electroconductive gel), three different types of devices and the radiographic view on the assessment of the electronic readings.Methodology: Thirty single‐rooted extracted human mandibular premolars were selected. After access and canal pre‐flaring, a size 10 K‐file was inserted in the canal up to the major apical foramen under magnification (×10), and this length was recorded as the actual length (AL) of the canal. Teeth were mounted on a specific endodontic training kit platform (ProTrain). Two different embedding media (electroconductive gel and alginate) and three different ERCLMDs: Apex ID (SybronEndo, Glendora, CA, USA), CanalPro Apex Locator (Coltene‐Endo, Cuyahoga Falls, OH, USA) and the Root ZX II (J. Morita, Tokyo, Japan), were tested. Following the measurement at the 0.5 mark of each ERCLMD using alginate, two periapical radiographs (bucco‐lingual and proximal views) were taken. The difference between the electronic readings and the AL, as well as the distance from the file tip to the apex of the roots on the radiographs, was calculated. Data were analysed statistically (two‐way anova, Tukey’s and chi‐squared tests) at 5% significance level.Results: The incidence of over‐extended readings was significantly greater (P < 0.05) when using the ProTrain electroconductive gel, except for Root ZX II at the 0.5 mark. Root ZX, CanalPro and Apex ID had similar accuracy when the 0.0/APEX mark was used to locate the foramen. For the radiographic method, no difference was found between the devices or radiographic views.Conclusion: Compared with alginate, the conductive gel of the ProTrain kit negatively affected most of the electronic readings. The three evaluated ERCLMDs had similar accuracy in locating the apical foramen when using the mark 0.0/APEX and alginate as the embedding media. Although the ProTrain platform allows radiographs to be exposed in both bucco‐lingual and proximal views, no difference was found between the views when evaluating the apical limit provided by the 0.5 mark in mandibular premolars embedded in alginate.


  • Open Access

    Endodontic Retreatment Using a Single Instrument from four Nickel-Titanium Systems - A Micro-CT Study

    by Marco Antonio Diniz Azevedo, Thiago Gomes da Silva, Ângela Fernandes, Lucila Piasecki, Luiz Fernando Fariniuk, Ulisses Xavier da Silva Neto

    This study evaluated the efficiency of using a single instrument from three different rotary multi-file systems and compared them with that of a reciprocating single-file for endodontic retreatment by means of micro-CT. Sixty extracted canines were prepared using a size F2 ProTaper Universal file and obturated. After 30 days of storage at 37ºC and 100% humidity, the teeth were randomly divided into four groups (n=15) based on the type of instrument used to retreatment: ProTaper Next (PTN), ProTaper Gold (PTG), TRUShape 3D (TS), and WaveOne (WO). The canals were retreated using only the size 40 instrument from each system according to the manufacturer’s recommendations for torque and speed. The time required to remove the filling material was recorded in seconds. The amount of initial and residual filling material and the quantity of dentin removed were assessed by means of micro-CT. Data were statistically analyzed (ANOVA and Kruskal-Wallis) at a 5% significance level. TS instruments required the highest (p<0.05) amount of time (mean, 384.80 ±144.92) compared with the WO (229.67±68.16) and PTG (248.67±64.22) and not so different from PTN instruments (327.67±133.3). No differences in the amount of dentin removed, initial and residual filling volume, and percentages of filling material were observed among the groups. The use of a single rotary instrument from the PTG, TS, and PTN systems was as effective as that of the single-file reciprocating WO system. However, none of the instruments was able to remove the filling materials completely.


  • The Buffalo study: Outcome and associated predictors in endodontic microsurgery‐ a cohort study

    by A. A. Azim, H. Albanyan, K. A. Azim, L. Piasecki

    Aim: To (i) evaluate and compare the outcome of endodontic microsurgery (EMS) using periapical radiographs (PAs) and cone‐beam computed tomography (CBCT) scans; (ii) identify prognostic factors affecting the outcome; and (iii) correlate the effect of guided tissue regeneration (GTR) on the pattern of apical bone remodelling.Methodology: Eighty‐two patients (101 teeth) who received EMS were included and followed‐up using clinical and radiographic examinations (PAs and CBCT scans). Two calibrated endodontists evaluated the radiographic healing (favourable or unfavourable) by assessing PAs and CBCT. The success (favourable radiographic outcome with no clinical symptoms) and survival rates (tooth retention without clinical symptoms) were calculated, and the cause of failure (diseased or fractured) was identified. Pre‐treatment (age, sex, tooth type, position, sequence of treatment, quality of root canal before surgery, presence/absence of through‐and‐through lesion, presence/absence apico‐marginal defect) and treatment (presence/absence of errors during surgery, type of error (major or minor), retro‐preparation depth, presence/absence of an isthmus, retro‐filling material used, presence/absence bone graft material and/or resorbable membrane) factors were recorded. Data were analysed statistically to determine the inter‐observer, intra‐observer and inter‐radiographic agreements. Univariate, bivariate and logistic regression analysis were used to determine prognostic factors affecting the outcome and the effect of GTR on the pattern of apical bone remodelling. The significance level was set at 5%.Results: Sixty‐eight patients (83 teeth) presented for outcome evaluation (recall rate: 84%). The survival rate was 93%. The success rate was 88% using PA and 86% using CBCT when vertical root fracture (VRF) cases were included and 94% using PAs, and 91% using CBCT when VRF cases were excluded. The intra‐ and inter‐observer agreements were substantial using CBCT, slight to a fair agreement using PA (P < 0.001), and slight to moderate for inter‐radiographic agreement. The occurence of a major procedural error during surgery was the only negative predictor for the outcome of EMS (P = 0.013). GTR did not affect the success rate or the type of healing when assessed using PA but it affected the type of healing on CBCT scans (complete vs incomplete healing) and the pattern of cortical plate remodelling (P < 0.001).Conclusion: The success and survival rate of endodontic microsurgery was very high, and the occurrence of a major procedural error during surgery was the only factor affecting the outcome. GTR did not improve the outcome, but did affect the quality of apical bone remodelling following EMS.


  • Accuracy of electronic apical functions of a new integrated motor compared to the visual control of the working length—an ex vivo study

    by Adriane Antoniw Klemz, Alessandra Timponi Goes Cruz, Lucila Piasecki, Everdan Carneiro, Vânia Portela Ditzel Westphalen, Ulisses Xavier da Silva Neto

    Objectives To evaluate ex vivo the efficacy of the integrated motor Tri Auto ZX2 in controlling the apical extent of preparation compared to conventional visual control (CVC) of the working length (WL). Materials and methods Eighty standardized mandibular premolars were divided into five groups (n = 16). In the CVC group, instruments were used in continuous rotation (CR) and visual control performed by means of rubber stoppers. For each of the remaining groups, it was assigned a combination of a motion (CR or optimal torque reverse (OTR)), and an apical function (Auto Apical Reverse (AAR) or Optimum Apical Stop (OAS)). Root canals were prepared using the apical functions at 0.5 mark using an alginate model. Difference between the final WL and the actual length post-instrumentation was calculated. Data were analyzed statistically with the significance set at 5% (ANOVA, Tukey HSD). Results There was no difference in the mean WL among the groups, except between the CR combined to OAS compared to CVC (P > 0.05). Although CVC resulted in two cases beyond the foramen, no significant difference was found among the groups when comparing the distributions of measurements (P > 0.05). Conclusions All combinations of motion and apical control functions of Tri Auto ZX2 provided an adequate apical limit ex vivo, similar to the visual control using rubber stoppers. Clinical relevance TriAuto ZX2 was efficient to control the apical extent of preparation dispensing the need for calibrating the files, regardless of the different settings. This motor might potentially prevent over-instrumentation by continuously monitoring the apical limit.