Farhan Quaiyum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Farhan Quaiyum has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Aly E. Fathy
EECS Department, Univeristy of Tennessee
2 shared publications - Jean E. Piou
Lexington, Massachusetts United States
2 shared publications Aly E. Fathy
1 shared publication- Antonino Secondo Fiorillo
Department of Health Sciences, Magna Grcia University of Catanzaro, Catanzaro, Italy
1 shared publication - Bardia Ghajari
La Jolla United States
1 shared publication - Christopher P. Stephens
Department of Pathology, Northwestern University Feinberg School of Medicine, Chicago, IL 60611 USA
1 shared publication
Latest Publications
- 24 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (2) , 155-167
Non-Contact Multi-Subject Human Gait Analysis Using A State-Space Method With Enhanced 1-D Block Representation
A stepped-frequency continuous-wave (SFCW) radar system with adequate pulse repetition frequency (PRF) is developed to track relatively fast motions from various parts of the human body, separately. Robust signal processing technique is utilized, where a 1-D block processing technique, based on state-space method (SSM) is developed in two dimensions to form an enhanced Hankel matrix to track human motions from two-dimensional (2-D) data collected using the developed SFCW radar system in single- or multi-subject motion scenarios. Experimental datasets are used to track body parts' motions and velocities with high accuracy. The significant improvement, besides de-noising the data, is due to the fact that applying the 1-D block processing technique to 2-D dataset matrix accounts for the correlation between motion's estimates from consecutive frames. Results agree well with our reference, the human Boulic model.
- 24 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (2) , 155-167
Non-Contact Multi-Subject Human Gait Analysis Using A State-Space Method With Enhanced 1-D Block Representation
A stepped-frequency continuous-wave (SFCW) radar system with adequate pulse repetition frequency (PRF) is developed to track relatively fast motions from various parts of the human body, separately. Robust signal processing technique is utilized, where a 1-D block processing technique, based on state-space method (SSM) is developed in two dimensions to form an enhanced Hankel matrix to track human motions from two-dimensional (2-D) data collected using the developed SFCW radar system in single- or multi-subject motion scenarios. Experimental datasets are used to track body parts' motions and velocities with high accuracy. The significant improvement, besides de-noising the data, is due to the fact that applying the 1-D block processing technique to 2-D dataset matrix accounts for the correlation between motion's estimates from consecutive frames. Results agree well with our reference, the human Boulic model.
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 61-70
Noncontact Human Gait Analysis and Limb Joint Tracking Using Doppler Radar
A full understanding of normal motion from human limb joint trajectory tracking could be essential to develop and establish a scientific basis for correcting any abnormalities. Practicality of using continuous wave (CW) radars, being simple and low cost, has been successfully investigated for non-contact gait monitoring, but it is still challenging to identify the motions of different limb joints. Here, we investigate the feasibility of extending the 1-D block processing algorithm to distinctly track specific limb joints and discuss the advantages and limitations of the technique for CW radar. To establish a repeatable reference data, we run a full wave EM analysis on customized Boulic human model emulating specific video recorded body motions. Results based on measured data are in agreement with simulated ones for simple motions like swinging one hand or one leg only. The proposed technique is also successful in extracting lower body parts while the whole body is in motion, however it is still hard to clearly extract upper body parts like swinging hands.
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 61-70
Noncontact Human Gait Analysis and Limb Joint Tracking Using Doppler Radar
A full understanding of normal motion from human limb joint trajectory tracking could be essential to develop and establish a scientific basis for correcting any abnormalities. Practicality of using continuous wave (CW) radars, being simple and low cost, has been successfully investigated for non-contact gait monitoring, but it is still challenging to identify the motions of different limb joints. Here, we investigate the feasibility of extending the 1-D block processing algorithm to distinctly track specific limb joints and discuss the advantages and limitations of the technique for CW radar. To establish a repeatable reference data, we run a full wave EM analysis on customized Boulic human model emulating specific video recorded body motions. Results based on measured data are in agreement with simulated ones for simple motions like swinging one hand or one leg only. The proposed technique is also successful in extracting lower body parts while the whole body is in motion, however it is still hard to clearly extract upper body parts like swinging hands.
- 2 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 8 (2) , 338-349
An Electromagnetic Model of Human Vital Signs Detection and Its Experimental Validation
An electromagnetic model for heart rate and respiration rate detection using the scattered fields of incident plane waves on a dielectric model of a human subject has been developed. The model approximates the torso by an equivalent homogenous dielectric layer, and utilizes an accelerated parallel version of the multi-level fast multipole algorithm to speed up the computation. Non-contact measurements using an ultra-wideband radar is utilized to experimentally validate the model. The model proved to be accurate for both heart rate and respiration rate detection within 5% error margin when compared to conventional contact sensor readings. The agreement between measured and simulated results is good for distances up to 3 m, and at various subject orientations with respect to the radar boresight. Meanwhile, in the presence of more than one subject, only slight degradation has been observed unless one subject is almost blocked by another. This accurate model would have broader impacts as it can be utilized to investigate various human activities and motion scenarios, and can be used, as well, to fine tune the signal processing techniques and radar system development.
- 2 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 8 (2) , 338-349
An Electromagnetic Model of Human Vital Signs Detection and Its Experimental Validation
An electromagnetic model for heart rate and respiration rate detection using the scattered fields of incident plane waves on a dielectric model of a human subject has been developed. The model approximates the torso by an equivalent homogenous dielectric layer, and utilizes an accelerated parallel version of the multi-level fast multipole algorithm to speed up the computation. Non-contact measurements using an ultra-wideband radar is utilized to experimentally validate the model. The model proved to be accurate for both heart rate and respiration rate detection within 5% error margin when compared to conventional contact sensor readings. The agreement between measured and simulated results is good for distances up to 3 m, and at various subject orientations with respect to the radar boresight. Meanwhile, in the presence of more than one subject, only slight degradation has been observed unless one subject is almost blocked by another. This accurate model would have broader impacts as it can be utilized to investigate various human activities and motion scenarios, and can be used, as well, to fine tune the signal processing techniques and radar system development.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
A low power wireless apnea detection system based on pyroelectric sensor
The paper presents a fully integrated system for apnea detection. Apnea has been one of the leading causes of death in the USA and it is even more critical for premature neonatal infants. A prototype device with the pyroelectric sensor and a wireless telemetry designed in 0.5 μm CMOS process is presented which overcomes the complexity of the point of care diagnosis of sleeping disorders.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
A low power wireless apnea detection system based on pyroelectric sensor
The paper presents a fully integrated system for apnea detection. Apnea has been one of the leading causes of death in the USA and it is even more critical for premature neonatal infants. A prototype device with the pyroelectric sensor and a wireless telemetry designed in 0.5 μm CMOS process is presented which overcomes the complexity of the point of care diagnosis of sleeping disorders.