Robert Frysch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Frysch has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Georg Rose
Otto-von-Guericke-University Magdeburg
3 shared publications Georg Rose
Otto Guericke Univ Magdeburg, Inst Med Engn, Magdeburg, Germany
2 shared publications- Hana Haseljić
Otto Guericke Univ Magdeburg, Inst Med Engn, Magdeburg, Germany
2 shared publications - Shiras Abdurahman
Institute for Medical Engineering and Research Campus STIMULATE, Otto-von-Guericke-Universitt, Magdeburg, Germany
2 shared publications Tim Pfeiffer
Otto-von-Guericke-University Magdeburg
2 shared publications- Andreas Nürnberger
Otto von Guericke University Magdeburg
1 shared publication
Latest Publications
- Open Access
- 8 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135032
A joint registration and extrapolation method for cone beam computed tomography volume of interest imaging
The high patient dose applied during acquisition of C-arm based cone beam computed tomography (CBCT) scans limits the applicability of this imaging technique. Acquisition of only a region-of-interest can decrease the dose significantly. However, reconstruction from such truncated projection data can lead to severe artifacts in the tomographic image. For typical usages of C-arm based CBCT however, there often exists a prior computed tomography or CBCT scan of the patient. The proposed method enables the incorporation of such priors into the reconstruction process by jointly registering and extrapolating the prior to the limited data acquisition scenario by maximizing consistency conditions across thusly extended projections. Results show improved image quality over simple heuristic extrapolation methods typically used in practice. The proposed method can be regarded as a novel hybrid registration and extrapolation algorithm similar to established digitally reconstructed radiographs-based registration methods, but unlike these, working on mutually disjoint regions of the projection data.
- 8 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135032
Open AccessA joint registration and extrapolation method for cone beam computed tomography volume of interest imaging
The high patient dose applied during acquisition of C-arm based cone beam computed tomography (CBCT) scans limits the applicability of this imaging technique. Acquisition of only a region-of-interest can decrease the dose significantly. However, reconstruction from such truncated projection data can lead to severe artifacts in the tomographic image. For typical usages of C-arm based CBCT however, there often exists a prior computed tomography or CBCT scan of the patient. The proposed method enables the incorporation of such priors into the reconstruction process by jointly registering and extrapolating the prior to the limited data acquisition scenario by maximizing consistency conditions across thusly extended projections. Results show improved image quality over simple heuristic extrapolation methods typically used in practice. The proposed method can be regarded as a novel hybrid registration and extrapolation algorithm similar to established digitally reconstructed radiographs-based registration methods, but unlike these, working on mutually disjoint regions of the projection data.
- 14 January 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 154, 106539
Liver segmentation using Turbolift learning for CT and cone-beam C-arm perfusion imaging
- 14 January 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 154, 106539
Liver segmentation using Turbolift learning for CT and cone-beam C-arm perfusion imaging
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (4) , 354-371
Comparative Evaluation of Cone-Beam Consistency Conditions for Mono-Material Beam Hardening Correction in Flat Detector Computed Tomography
Consistency conditions have been successfully utilized for data-driven artifact reductions in cone-beam computed tomography systems equipped with a large area flat-panel detector. Recently, many formulations and applications of pair-wise cone-beam consistency conditions have been published, including Grangeat, Smith, and fan-beam consistency conditions. Previous works demonstrated that the polynomial coefficients for beam hardening correction could be directly computed from cone-beam raw data by enforcing consistency conditions on projection pairs. This paper compares the effectiveness of pair-wise consistency conditions for mono-material beam hardening correction using a second-degree polynomial. The results from our studies show that similar corrections could be achieved for ideal polychromatic projections. We also investigated the effectiveness of corrections after perturbing the projections with an increasing degree of errors other than those caused by beam hardening. The studies indicate the superior robustness of fan-beam consistency conditions towards Poisson noise, axial truncation, detector shift, and scatter, while Grangeat consistency conditions were less vulnerable to projection intensity errors. The optimal choice of consistency conditions depends on the CBCT system geometry, physical phenomena other than beam hardening, and the availability and accuracy of pre-processing and artifact corrections algorithms before beam hardening correction.
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (4) , 354-371
Comparative Evaluation of Cone-Beam Consistency Conditions for Mono-Material Beam Hardening Correction in Flat Detector Computed Tomography
Consistency conditions have been successfully utilized for data-driven artifact reductions in cone-beam computed tomography systems equipped with a large area flat-panel detector. Recently, many formulations and applications of pair-wise cone-beam consistency conditions have been published, including Grangeat, Smith, and fan-beam consistency conditions. Previous works demonstrated that the polynomial coefficients for beam hardening correction could be directly computed from cone-beam raw data by enforcing consistency conditions on projection pairs. This paper compares the effectiveness of pair-wise consistency conditions for mono-material beam hardening correction using a second-degree polynomial. The results from our studies show that similar corrections could be achieved for ideal polychromatic projections. We also investigated the effectiveness of corrections after perturbing the projections with an increasing degree of errors other than those caused by beam hardening. The studies indicate the superior robustness of fan-beam consistency conditions towards Poisson noise, axial truncation, detector shift, and scatter, while Grangeat consistency conditions were less vulnerable to projection intensity errors. The optimal choice of consistency conditions depends on the CBCT system geometry, physical phenomena other than beam hardening, and the availability and accuracy of pre-processing and artifact corrections algorithms before beam hardening correction.
- Open Access
- 20 April 2022
- Published by Wiley in Medical Physics
- Vol. 49 (6) , 3624-3637
A novel use of time separation technique to improve flat detector CT perfusion imaging in stroke patients
Background: CT perfusion imaging (CTP) is used in the diagnostic workup of acute ischemic stroke (AIS). CTP may be performed within the angio suite using flat detector CT (FDCT) to help reduce patient management time.Purpose: In order to significantly improve FDCT perfusion (FDCTP) imaging, data‐processing algorithms need to be able to compensate for the higher levels of noise, slow rotation speed, and a lower frame rate of current FDCT devices.Methods: We performed a realistic simulation of FDCTP acquisition based on CTP data from seven subjects. We used the time separation technique (TST) as a model‐based approach for FDCTP data processing. We propose a novel dimension reduction in which we approximate the time attenuation curves by a linear combination of trigonometric functions. Our goal was to show that the TST can be used even without prior assumptions on the shape of the attenuation profiles.Results: We first demonstrated that a trigonometric basis is suitable for dimension reduction of perfusion data. Using simulated FDCTP data, we have shown that a trigonometric basis in the TST provided better results than the classical straightforward processing even with additional noise. Average correlation coefficients of perfusion maps were improved for cerebral blood flow (CBF), cerebral blood volume, mean transit time (MTT) maps. In a moderate noise scenario, the average Pearson's coefficient for the CBF map was improved using the TST from 0.76 to 0.81. For the MTT map, it was improved from 0.37 to 0.45. Furthermore, we achieved a total processing time from the reconstruction of FDCTP data to the generation of perfusion maps of under 5 min.Conclusions: In our study cohort, perfusion maps created from FDCTP data using the TST with a trigonometric basis showed equivalent perfusion deficits to classic CT perfusion maps. It follows, that this novel FDCTP technique has potential to provide fast and accurate FDCTP imaging for AIS patients.
- 20 April 2022
- Published by Wiley in Medical Physics
- Vol. 49 (6) , 3624-3637
Open AccessA novel use of time separation technique to improve flat detector CT perfusion imaging in stroke patients
Background: CT perfusion imaging (CTP) is used in the diagnostic workup of acute ischemic stroke (AIS). CTP may be performed within the angio suite using flat detector CT (FDCT) to help reduce patient management time.Purpose: In order to significantly improve FDCT perfusion (FDCTP) imaging, data‐processing algorithms need to be able to compensate for the higher levels of noise, slow rotation speed, and a lower frame rate of current FDCT devices.Methods: We performed a realistic simulation of FDCTP acquisition based on CTP data from seven subjects. We used the time separation technique (TST) as a model‐based approach for FDCTP data processing. We propose a novel dimension reduction in which we approximate the time attenuation curves by a linear combination of trigonometric functions. Our goal was to show that the TST can be used even without prior assumptions on the shape of the attenuation profiles.Results: We first demonstrated that a trigonometric basis is suitable for dimension reduction of perfusion data. Using simulated FDCTP data, we have shown that a trigonometric basis in the TST provided better results than the classical straightforward processing even with additional noise. Average correlation coefficients of perfusion maps were improved for cerebral blood flow (CBF), cerebral blood volume, mean transit time (MTT) maps. In a moderate noise scenario, the average Pearson's coefficient for the CBF map was improved using the TST from 0.76 to 0.81. For the MTT map, it was improved from 0.37 to 0.45. Furthermore, we achieved a total processing time from the reconstruction of FDCTP data to the generation of perfusion maps of under 5 min.Conclusions: In our study cohort, perfusion maps created from FDCTP data using the TST with a trigonometric basis showed equivalent perfusion deficits to classic CT perfusion maps. It follows, that this novel FDCTP technique has potential to provide fast and accurate FDCTP imaging for AIS patients.
- 1 February 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (1) , 40-50
Reduction of beam hardening artifacts on real C-arm CT data using polychromatic statistical image reconstruction
- 1 February 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (1) , 40-50
Reduction of beam hardening artifacts on real C-arm CT data using polychromatic statistical image reconstruction