MRManuel Rodrigues

Manuel Rodrigues

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manuel Rodrigues has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MicroSTAR: NGGM Space Accelerometer Last Developments

    by Kristen Maquaire, Damien Boulanger, Ratana Chhun, Bruno Christophe, Marine Dalin, Théophile Hervieux, Vincent Lebat, Françoise Liorzou, Grégoire Pique, Manuel Rodrigues, et al.

    ONERA laboratory have been providing highly sensitive electrostatic accelerometers involved in all major space Geodesy missions for more than five decades. Since the first mission launched, the accuracy of the accelerometers has significantly improved over time. For instance, the ESA GOCE mission accelerometers exhibited a few 10-12ms-2Hz-1/2 resolution. In a Fundamental Physics application, the T-SAGE accelerometers developed at ONERA allowed to test the Equivalence Principle on board the MICROSCOPE satellite at a level of 10-15, establishing in 2022 the best accuracy ever achieved for the test, besting the previous one attained with Lunar Laser Ranging by two orders of magnitude.Currently, MicroSTAR accelerometers are selected for ESA Next Generation Gravity Mission (NGGM). This mission aims to extend observations provided by GRACE-family satellites, with the same strategy. ONERA’s project is ongoing and the instrument phase C started early 2026. Currently, the mechanical sensor reached TRL-6 while the electronic unit and the overall system achieved TRL-5 with a performance level foreseen of about a few 10-12ms-2Hz-1/2. In the same fashion as the past instruments, the accelerometer is based on the electrostatic suspension of a proof-mass. The position and the attitude of the mass are measured and controlled with capacitive sensors and actuators. One of the main improvements of MicroSTAR is its cubic proof-mass, as opposed to the previous parallelepipedal ones in SuperSTAR-type accelerometers, which allows a high accuracy measurement along and around all three axes.To reach the technical and performance needs of NGGM, improvements in all technological fields are fundamental. In this presentation, the current development of MicroSTAR with its challenges and key strengths will be presented.

  • Open Access

    Le satellite MICROSCOPE teste la Relativité Générale à des précisions inégalées

    by Manuel Rodrigues

    Depuis le lancement du satellite MICROSCOPE en 2016, les physiciens attendaient fébrilement les résultats du test du principe d’équivalence à des précisions de l’ordre de 10-15, niveaux inaccessibles sur Terre. Le résultat final est tombé et Einstein demeure le maitre du jeu.

  • Open Access

    CubeSTAR: a tiny space accelerometer for Earth observation applications

    by Damien Boulanger, Bruno Christophe, Vincent Lebat, Françoise Liorzou, Kristen Maquaire, Nolwenn Portier, Manuel Rodrigues

    The New Space has opened opportunities for low cost space applications. ONERA is currently leading several CubeSat/nanosat missions: CREME for the sun radiation monitoring, CROCUS for the study of electrostatic satellite charging, FlyLab a demonstrator of optical and radar systems. Our laboratory is giving some support to all these teams because of its long experience in space missions. Indeed, the laboratory has been involved in all major space Geodesy missions by providing highly sensitive electrostatic accelerometer for more than 5 decades. Since the 70’s, the resolution of the accelerometers has been improved leading to outstanding results with the ESA GOCE mission where the accelerometers exhibited a few 10-12m.s-2.Hz-½ resolution. Out of Geodesy application, the accelerometers developed in ONERA have allowed to test the Equivalence Principle on board the MICROSCOPE satellite at a level of 10–15, establishing in 2022 the best test ever made. Taking advantage of this particular know-how quite unique in the world, the laboratory is studying the feasibility of measuring the Earth’s Energy Imbalance (EEI) by a direct measurement of the acceleration exerted by the radiation pressure on the satellite. The current EEI budget is obtained by combining space measurement of radiometers and local temperature measurements of Oceans. But the combination from different sources gives rise to bias and uncertainties. The objective of the Accelerometer measurement is to solve these uncertainties. A new accelerometer more compact, CubeSTAR, is under study in the laboratory in view of an utilisation in CubeSats for science application. EEI characterisation or Geodesy mission with multiple CubeSats may emerge as a costless alternative to 500-kg satellites. In this presentation, from previous experiments, we will describe the preliminary design drivers of the accelerometer candidate with its potential performance and show how it may be used in different space applications.


  • Open Access

    ONERA accelerometers for NGGM and for future gravity missions.

    by Kristen Maquaire, Antoine Ait-Mehdi, Damien Boulanger, Ratana Chhun, Bruno Christophe, Marine Dalin, Théophile Hervieux, Vincent Lebat, Françoise Liorzou, Nolwenn Portier, et al.

    The 2017-2027 Decadal Survey for Earth Science and Applications from Space has identified the Targeted Mass Change Observable as one of 5 Designated Mission. In Europe, the development of the ESA Next Generation Gravity Mission is on progress, with the start of the Phase B in 2024.These missions will continue the observation provided by GRACE and GRACE-FO. In these missions and the future concepts, the accelerometer provides either the gravity signal in a gradiometer configuration (GOCE type mission), or the non-gravitational acceleration to be suppressed to the ranging measurement between two satellites (GRACE-type mission).In the frame of NGGM activities with ESA, Onera is developing the new accelerometer MicroSTAR, a high accuracy accelerometer with 3 sensitive linear acceleration measurements as well as 3 angular acceleration measurements for the attitude control or reconstruction. PDR of the accelerometer chain has been done at the end of year 2024 and CDR of the accelerometer sensor head will be held in May 2025.ONERA have procured the accelerometer for all the previous gravity missions (GRACE, GOCE, GRACE-FO). In parallel, ONERA work to improve the scientific return of the instruments for the future missions:a miniaturized version of MicroSTAR, the CubeSTAR accelerometer, is developed with internal funding. CubeSTAR is adapted for constellation or nanosat, An other way is to improve the low-frequency noise of the accelerometer, by hybridization of electrostatic accelerometer with cold atom interferometer. The presentation will present the status of the MicroSTAR development, and will detail the development of future instruments.

  • Open Access

    50 years of legacy in space accelerometer missions for measuring Earth's energy imbalance

    by Manuel Rodrigues, Bruno Christophe, Kristen Maquaire, Nolwenn Portier

    For 50 years, ONERA has been developing space accelerometers for Geodesy or Fundamental Physics missions: CHAMP, GRACE series, GOCE, MAGIC, MICROSCOPE. For the latest one, the laboratory had the science responsibility and learned better understanding of mission design. By taking advantage of these experiences, we proposed to review the old 80’s concept mission called BIRAMIS aiming at measuring the Earth’s radiative energy imbalance (EEI). The EEI represents the difference between the incoming solar radiation and the outgoing longwave radiation at the top of the atmosphere and is fundamental to estimate the effect of anthropogenic greenhouse gases (GHG) emissions on our climate system.Currently, EEI is known with a stability of ~+/- 0.2 W/m² over a decade. However, this estimate is biased due to the performance of radiometry and to limited in-flight calibration. Some improvement is brought by using in-situ oceanic and geodetic (gravimetry and altimetry) measurements to estimate the ocean heat uptake. These measurements helps to evaluate EEI with an accuracy of +/- 0.3 W/m² on the time mean.The accelerometer performances used for the previous missions exhibit resolutions from 10 to 0.1 pico-g. That allows us to imagine a new mission with direct measurements of the radiation pressure on a satellite and to envisage accuracies much better than 0.1 W/m² on the time mean. Decadal-scale variations in EEI induced by solar cycles, volcanic eruptions and variations in GHG emissions could be closely monitored for the benefit of the study of climate change.

  • Open Access

    Improvement of ONERA Electrostatically suspended torsion pendulum

    by Nolwenn Portier, Bruno Christophe, Marine Dalin, Vincent Lebat, Françoise Liorzou, Manuel Rodrigues

    In order to meet the objectives of the Next Generation Gravity Mission (NGGM), the French Aerospace Lab ONERA is developing a new accelerometer concept MicroSTAR with three sensitive linear and three true angular acceleration measurements (Dalin et al., session G4). This instrument benefits from previous developed accelerometers which flew in the well-known gravity space missions: CHAMP, GRACE, GOCE, GRACE-FO.The principle of operation of these accelerometers is to maintain motionless a proof-mass with respect to the surrounding electrodes using a control loop. The applied electrostatic forces needed for this control, are proportional to the accelerations suffered by the proof-mass. The proof-mass is polarized with a very thin (few micrometer) wire in order to measure precisely its position by capacitive detection with the electrodes and to avoid charging in orbit. The stiffness and damping induced by the polarization wire impact the performance of the accelerometer at low frequencies. To quantify on-ground the performance limitation due to the wire, an electrostatically suspended torsion pendulum (PTSE) is used (Willemenot 1997, Willemenot and Touboul 2000).The PTSE is a six-axes servo-controlled accelerometer, optimized for the measurement of angular accelerations about the vertical axis. The torque noise spectral density is 1.3 10-14 Nm/√Hz around 0.05 Hz with a 1/√f increase at lower frequency, corresponding to 10-8 rad/s²/√Hz , and 2 10-10 ms-2/√Hz with a lever arm of 2cm. For instance, regarding a gold wire of 7.5µm diameter and 1.7cm length, we use it to measure theoretical stiffness of 2.5 10-5 N/m i.e. a torsion of 10-8 Nm/rad. In our presentation, this instrument will be described before sharing ideas for its improvement. Willemenot, P. Touboul; Electrostatically suspended torsion pendulum. Rev Sci Instrum 1 January 2000a; 71 (1): 310–314. https://doi.org/10.1063/1.1150198Willemenot, P. Touboul; On-ground investigation of space accelerometers noise with an electrostatic torsion pendulum. Rev Sci Instrum 1 January 2000b ; 71 (1): 302–309. https://doi.org/10.1063/1.1150197Willemenot, Pendule de torsion à suspension électrostatique, très hautes résolutions des accéléromètres spatiaux pour la physique fondamentale. Ph.D. thesis, Université Paris 11, France, 1997

  • Open Access

    ONERA accelerometers for future gravity mission

    by Marine Dalin, Bruno Christophe, Vincent Lebat, Damien Boulanger, Francoise Liorzou, Manuel Rodrigues, Nassim Zahzam, Yannick Bidel, Alexandre Bresson

    The 2017-2027 Decadal Survey for Earth Science and Applications from Space has identified the Targeted Mass Change Observable as one of 5 Designated Mission. In Europe, ESA has confirmed at Ministerial Counsel of November 2022 to continue the development on the Next Generation Gravity Mission with a Phase B.These missions will continue the observation provided by GRACE and GRACE-FO. In these missions and the future concepts, the accelerometer provides either the gravity signal in a gradiometer configuration (GOCE type mission), or the non-gravitational acceleration to be suppressed to the ranging measurement between two satellites (GRACE-type mission).ONERA has procured the accelerometer for all the previous gravity missions (GRACE, GOCE, GRACE-FO) and works to improve the scientific return of the instruments for the future missions.In a frame of a contract with ESA, ONERA is developing its new accelerometer MicroSTAR, a high accuracy accelerometer with 3 sensitive linear acceleration measurements as well as 3 angular acceleration measurements for the attitude control or reconstruction.In parallel, a miniaturized version of MicroSTAR with low accuracy, CubeSTAR accelerometer, is developed with internal funding. CubeSTAR is adapted for constellation or nanosat.Another way is to improve the low-frequency noise of the accelerometer, by hybridization of electrostatic accelerometer with cold atom interferometer.The presentation will detail these developments.

  • De la loi de la gravitation universelle à MICROSCOPE

    by Manuel Rodrigues

    Depuis Galilée, l’universalité de la chute libre des corps questionne les physiciens : la chute s’effectue dans le vide indépendamment de la masse et de la composition. Avec la théorie de la relativité générale, Einstein révolutionne la compréhension de la gravitation. Le principe d’Equivalence est alors posé par Einstein comme principe fondateur de la relativité générale avec pour première conséquence : l’universalité de la chute libre. Ce principe testé de plus en plus précisément depuis Galilée vient de franchir une nouvelle étape grâce à la mission spatiale MICROSCOPE qui a amélioré la précision du test de deux ordres de grandeur à 2,7×10 -15 .

  • Open Access

    Research campaign: Macroscopic quantum resonators (MAQRO)

    by Rainer Kaltenbaek, Markus Arndt, Markus Aspelmeyer, Peter F Barker, Angelo Bassi, James Bateman, Alessio Belenchia, Joel Bergé, Claus Braxmaier, Sougato Bose, et al.

    The objective of the proposed macroscopic quantum resonators (MAQRO) mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments at the interface with gravity. Developing the necessary technologies, achieving the required sensitivities and providing the necessary isolation of macroscopic quantum systems from their environment will lay the path for developing novel quantum sensors. Earlier studies showed that the proposal is feasible but that several critical challenges remain, and key technologies need to be developed. Recent scientific and technological developments since the original proposal of MAQRO promise the potential for achieving additional science objectives. The proposed research campaign aims to advance the state of the art and to perform the first macroscopic quantum experiments in space. Experiments on the ground, in micro-gravity, and in space will drive the proposed research campaign during the current decade to enable the implementation of MAQRO within the subsequent decade.


  • Top Cited Papers

    MICROSCOPE Mission: Final Results of the Test of the Equivalence Principle

    by Pierre Touboul, Gilles Métris, Manuel Rodrigues, Joel Bergé, Alain Robert, Quentin Baghi, Yves André, Judicaël Bedouet, Damien Boulanger, Stefanie Bremer, et al.

    The MICROSCOPE mission was designed to test the weak equivalence principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of 10−15 in terms of the Eötvös ratio η. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electrostatic forces required to keep them in equilibrium. This was done with ultrasensitive differential electrostatic accelerometers onboard a drag-free satellite. The mission lasted two and a half years, cumulating five months worth of science free-fall data, two-thirds with a pair of test masses of different compositions—titanium and platinum alloys—and the last third with a reference pair of test masses of the same composition—platinum. We summarize the data analysis, with an emphasis on the characterization of the systematic uncertainties due to thermal instabilities and on the correction of short-lived events which could mimic a WEP violation signal. We found no violation of the WEP, with the Eötvös parameter of the titanium and platinum pair constrained to η(Ti,Pt)=[−1.5±2.3(stat)±1.5(syst)]×10−15 at 1σ in statistical errors.