Sandeep Kumar Mishra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sandeep Kumar Mishra has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Satyen Parida
Department of Anesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India
8 shared publicationsLenin Babu Elakkumanan
Department of Anesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India
5 shared publications- Pankaj Kundra
Department of Anaesthesiology and critical care, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
5 shared publications - Prasanna Udupi Bidkar
Department of Anesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
5 shared publications - Satyen Parida
Dept of Anaesthesiology & Critical Care, JIPMER, JIPMER Campus, Puducherry, India
4 shared publications Ashok Shankar Badhe
Departments of Anaesthesiology & Critical Care, Jawaharlal Institute of Post-Graduate Medical Education and Research, Gorimedu, Puducherry, India
3 shared publications
Latest Publications
- 10 June 2026
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 143 (6) , 1407-1409
A Randomized Double-Blinded Study of Enteral Nutrition Calorific Targets in Critical Illness: Influence of Ultrasound Measurement of Gastric Residual Volume
- 10 June 2026
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 143 (6) , 1407-1409
A Randomized Double-Blinded Study of Enteral Nutrition Calorific Targets in Critical Illness: Influence of Ultrasound Measurement of Gastric Residual Volume
- Open Access
- 16 April 2025
- Vol. 69 (5) , 458-464
Ease of intubation using oral Microcuff RAE (Ring–Adair–Elwyn) tube with and without premounted Frova intubating introducer in children undergoing cleft lip and palate surgeries – A randomised controlled study
Ring–Adair–Elwyn (RAE) tracheal tube is morphologically different from the routine endotracheal tubes. Unlike conventional endotracheal tubes, the passage of the RAE tube through the laryngopharynx and vocal cords might be challenging. We hypothesised that an oral RAE endotracheal tube railroaded over the Frova intubating introducer would reduce intubation time. Eighty children with cleft lip and palate anomalies without additional difficult airway predictors were enroled. They were randomly assigned to two groups: Group Frova (n = 40), which received preloaded oral RAE tracheal tubes with a Frova intubating introducer, and Group Non-Frova (n = 40), which received oral RAE tracheal tubes without the Frova introducer. The primary outcome was the tracheal intubation time. Secondary outcomes were the first-attempt intubation success rate, the need for external laryngeal manoeuvres (ELMs), ease of intubation and airway complications. The mean age (months) was 21 [standard deviation (SD): 14.2] in Group Frova and 20.7 (SD: 13.5) in Group Non-Frova. The mean intubation time (sec) was not different between Group Frova and Group Non-Frova [39.15 (SD: 15.39) (95% confidence interval {CI}: 31.3, 47.0) vs. 35.76 (SD: 15.29) (95% CI: 27.9, 43.6); mean difference = 3.39 (95% CI: −3.6, 10.41); P = 0.338]. Furthermore, the first-attempt success rate was comparable between groups (34 vs. 29, P = 0.308). There was no difference in the requirement of ELMs (13 vs. 17, P = 0.261), and the ease of intubation was also comparable. Frova introducer-guided endotracheal intubation with an oral RAE tube does not decrease intubation time in children undergoing cleft lip and palate surgery.
- 16 April 2025
- Vol. 69 (5) , 458-464
Open AccessEase of intubation using oral Microcuff RAE (Ring–Adair–Elwyn) tube with and without premounted Frova intubating introducer in children undergoing cleft lip and palate surgeries – A randomised controlled study
Ring–Adair–Elwyn (RAE) tracheal tube is morphologically different from the routine endotracheal tubes. Unlike conventional endotracheal tubes, the passage of the RAE tube through the laryngopharynx and vocal cords might be challenging. We hypothesised that an oral RAE endotracheal tube railroaded over the Frova intubating introducer would reduce intubation time. Eighty children with cleft lip and palate anomalies without additional difficult airway predictors were enroled. They were randomly assigned to two groups: Group Frova (n = 40), which received preloaded oral RAE tracheal tubes with a Frova intubating introducer, and Group Non-Frova (n = 40), which received oral RAE tracheal tubes without the Frova introducer. The primary outcome was the tracheal intubation time. Secondary outcomes were the first-attempt intubation success rate, the need for external laryngeal manoeuvres (ELMs), ease of intubation and airway complications. The mean age (months) was 21 [standard deviation (SD): 14.2] in Group Frova and 20.7 (SD: 13.5) in Group Non-Frova. The mean intubation time (sec) was not different between Group Frova and Group Non-Frova [39.15 (SD: 15.39) (95% confidence interval {CI}: 31.3, 47.0) vs. 35.76 (SD: 15.29) (95% CI: 27.9, 43.6); mean difference = 3.39 (95% CI: −3.6, 10.41); P = 0.338]. Furthermore, the first-attempt success rate was comparable between groups (34 vs. 29, P = 0.308). There was no difference in the requirement of ELMs (13 vs. 17, P = 0.261), and the ease of intubation was also comparable. Frova introducer-guided endotracheal intubation with an oral RAE tube does not decrease intubation time in children undergoing cleft lip and palate surgery.
- Open Access
- 13 March 2025
- Published by Wolters Kluwer Health in Indian Journal of Anaesthesia
- Vol. 69 (4) , 343-349
Effect of preoperative oxytocin infusion on haemodynamics among women undergoing elective caesarean section under spinal anaesthesia: A randomised controlled study
Background and Aims: Various strategies to improve haemodynamics to avoid hypotension following spinal anaesthesia for caesarean section are reported. Uterine contractions induced with oxytocin lead to autotransfusion that may aid in maintaining blood pressure by increasing preload. This study aimed to compare the haemodynamic effects of initiating prophylactic oxytocin infusion preoperatively versus starting it after foetal delivery among women undergoing elective caesarean section under spinal anaesthesia. Methods: In this randomised controlled study, women undergoing elective caesarean section under spinal anaesthesia were assigned following simple randomisation to receive either oxytocin infusion at the rate of 6 milli-IU/min (Group O) or only normal saline alone (Group C), started before spinal anaesthesia, along with both receiving preloading with normal saline infusion. Hypotension was treated with a bolus dose of intravenous phenylephrine. Changes in the haemodynamic parameters, heart rate, systolic blood pressure (SBP), mean arterial pressure and non-invasive cardiac output (CO) indices (CO and stroke volume) assessed using a non-invasive CO monitor were compared between groups. Results: Hypotension occurred in 19 women in Group C (59.4%) compared to three in Group O (8.6%). A significant fall in SBP and CO was observed in Group C compared to Group O ( P < 0.001). Phenylephrine requirement was significantly higher in Group C [21.9 (21.4, 95% confidence interval {CI} 13.6, 28.2)] compared to Group O [1.7 (5.7, 95% CI: 0.2, 3.7)] ( P < 0.001). The total dose of oxytocin was significantly higher in Group C (median 10 IU, range: 8–13) versus Group O (median 5 IU, range: 0–5) ( P < 0.001). Conclusion: Preoperative prophylactic oxytocin infusion provides better haemodynamic stability in women undergoing elective caesarean section under spinal anaesthesia and reduces the incidence of hypotension and the requirement for phenylephrine.
- 13 March 2025
- Published by Wolters Kluwer Health in Indian Journal of Anaesthesia
- Vol. 69 (4) , 343-349
Open AccessEffect of preoperative oxytocin infusion on haemodynamics among women undergoing elective caesarean section under spinal anaesthesia: A randomised controlled study
Background and Aims: Various strategies to improve haemodynamics to avoid hypotension following spinal anaesthesia for caesarean section are reported. Uterine contractions induced with oxytocin lead to autotransfusion that may aid in maintaining blood pressure by increasing preload. This study aimed to compare the haemodynamic effects of initiating prophylactic oxytocin infusion preoperatively versus starting it after foetal delivery among women undergoing elective caesarean section under spinal anaesthesia. Methods: In this randomised controlled study, women undergoing elective caesarean section under spinal anaesthesia were assigned following simple randomisation to receive either oxytocin infusion at the rate of 6 milli-IU/min (Group O) or only normal saline alone (Group C), started before spinal anaesthesia, along with both receiving preloading with normal saline infusion. Hypotension was treated with a bolus dose of intravenous phenylephrine. Changes in the haemodynamic parameters, heart rate, systolic blood pressure (SBP), mean arterial pressure and non-invasive cardiac output (CO) indices (CO and stroke volume) assessed using a non-invasive CO monitor were compared between groups. Results: Hypotension occurred in 19 women in Group C (59.4%) compared to three in Group O (8.6%). A significant fall in SBP and CO was observed in Group C compared to Group O ( P < 0.001). Phenylephrine requirement was significantly higher in Group C [21.9 (21.4, 95% confidence interval {CI} 13.6, 28.2)] compared to Group O [1.7 (5.7, 95% CI: 0.2, 3.7)] ( P < 0.001). The total dose of oxytocin was significantly higher in Group C (median 10 IU, range: 8–13) versus Group O (median 5 IU, range: 0–5) ( P < 0.001). Conclusion: Preoperative prophylactic oxytocin infusion provides better haemodynamic stability in women undergoing elective caesarean section under spinal anaesthesia and reduces the incidence of hypotension and the requirement for phenylephrine.
- Open Access
- 11 August 2022
- Published by Springer Nature in Cureus
- Vol. 14 (8) , e27888
Comparison of Gastric Insufflation Volume Between Ambu AuraGain and ProSeal Laryngeal Mask Airway Using Ultrasonography in Patients Undergoing General Anesthesia: A Randomized Controlled Trial
Introduction: Ambu AuraGain and ProSeal laryngeal mask airway are second-generation supraglottic airway devices (SADs) with added advantage of gastric drain and better oropharyngeal sealing pressure. The primary objective was to study the difference in the gastric insufflation volume between Ambu AuraGain and ProSeal LMA in patients undergoing general anesthesia. Methods: This randomized controlled trial involving 120 adult patients scheduled under general anesthesia were randomized into either Ambu AuraGain or LMA ProSeal group. Gastric cross-sectional area was measured using ultrasonography at baseline, after mask ventilation, and at the end of surgery. Gastric volume was calculated from the measured cross-sectional area. Oropharyngeal sealing pressure, peak airway pressure, and postoperative complications were noted. Statistical analysis was done using SPSS version 22 (Armonk, NY: IBM Corp.) and p < 0.05 was considered statistically significant. Results: Demographic profile of the study groups was comparable. There was a significant difference in gastric volume between the groups at the end of surgery with 5.91 ml (±9.68 ml) in Ambu AuraGain group and 12.28 ml (±13.05 ml) in the LMA ProSeal group (p = 0.001). Similarly, there was a difference in volume between baseline and at the end of the surgery within the groups also (Ambu AuraGain group, p=0.0012; LMA ProSeal group, p=0.0015, respectively). Though the oropharyngeal sealing pressure and peak airway pressures were comparable, increased incidence of postoperative complications was observed with LMA ProSeal. Conclusion: Thus, Ambu AuraGain resulted in a lower gastric insufflation volume than LMA ProSeal with lesser incidence of postoperative complications.
- 11 August 2022
- Published by Springer Nature in Cureus
- Vol. 14 (8) , e27888
Open AccessComparison of Gastric Insufflation Volume Between Ambu AuraGain and ProSeal Laryngeal Mask Airway Using Ultrasonography in Patients Undergoing General Anesthesia: A Randomized Controlled Trial
Introduction: Ambu AuraGain and ProSeal laryngeal mask airway are second-generation supraglottic airway devices (SADs) with added advantage of gastric drain and better oropharyngeal sealing pressure. The primary objective was to study the difference in the gastric insufflation volume between Ambu AuraGain and ProSeal LMA in patients undergoing general anesthesia. Methods: This randomized controlled trial involving 120 adult patients scheduled under general anesthesia were randomized into either Ambu AuraGain or LMA ProSeal group. Gastric cross-sectional area was measured using ultrasonography at baseline, after mask ventilation, and at the end of surgery. Gastric volume was calculated from the measured cross-sectional area. Oropharyngeal sealing pressure, peak airway pressure, and postoperative complications were noted. Statistical analysis was done using SPSS version 22 (Armonk, NY: IBM Corp.) and p < 0.05 was considered statistically significant. Results: Demographic profile of the study groups was comparable. There was a significant difference in gastric volume between the groups at the end of surgery with 5.91 ml (±9.68 ml) in Ambu AuraGain group and 12.28 ml (±13.05 ml) in the LMA ProSeal group (p = 0.001). Similarly, there was a difference in volume between baseline and at the end of the surgery within the groups also (Ambu AuraGain group, p=0.0012; LMA ProSeal group, p=0.0015, respectively). Though the oropharyngeal sealing pressure and peak airway pressures were comparable, increased incidence of postoperative complications was observed with LMA ProSeal. Conclusion: Thus, Ambu AuraGain resulted in a lower gastric insufflation volume than LMA ProSeal with lesser incidence of postoperative complications.
- 15 May 2020
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 31 (5) , 378-383
Polidocanol versus phenol in oil injection sclerotherapy in treatment of internal hemorrhoids: A randomized controlled trial
Background/Aims: Management of Haemorrhoids is suboptimal and is largely based on traditional practices in the Indian population. Though injection sclerotherapy is a well-accepted treatment modality in early grade haemorrhoids, there is no consensus on the effectiveness of the drugs used for sclerotherapy. The study was done to compare the safety and efficacy of a standard sclerosant (polidocanol) and the conventionally used phenol in oil in bleeding grade-1 and 2 internal haemorrhoids. Materials and Methods: All patients with grade-1 and 2 hemorrhoids, were selected and randomised into two groups, 3% polidocanol and 5% phenol group. All patients were followed-up for three months and observed for “free of bleeding” or “persistent bleeding.” Pain, pruritus and patient satisfaction following the procedure was also assessed. Results: A total of 150 patients were enrolled, 75 in each group. At the end of the first sclerotherapy session with polidocanol, 60.6% of patients versus 38.1% in phenol group had stopped per rectal bleeding (p=0.009). After the second sclerotherapy session, 94.7% of patients in the polidocanol group and 84% of patients in the phenol group were treated successfully. Polidocanol group required significantly fewer treatment sessions than the phenol group (1.39±0.49 vs. 1.62±0.49; p=0.035), and the total volume of injected sclerosant was also less (3.30±0.96 mL vs. 4.86±1.46 mL; p=0.001). The patient satisfaction was 87% in polidocanol group versus 73% in phenol group (p=0.040). Conclusion: 3% polidocanol is safe and more effective than 5% phenol in oil when used as injection sclerotherapy in the treatment of first and second-degree internal hemorrhoids.
- 15 May 2020
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 31 (5) , 378-383
Polidocanol versus phenol in oil injection sclerotherapy in treatment of internal hemorrhoids: A randomized controlled trial
Background/Aims: Management of Haemorrhoids is suboptimal and is largely based on traditional practices in the Indian population. Though injection sclerotherapy is a well-accepted treatment modality in early grade haemorrhoids, there is no consensus on the effectiveness of the drugs used for sclerotherapy. The study was done to compare the safety and efficacy of a standard sclerosant (polidocanol) and the conventionally used phenol in oil in bleeding grade-1 and 2 internal haemorrhoids. Materials and Methods: All patients with grade-1 and 2 hemorrhoids, were selected and randomised into two groups, 3% polidocanol and 5% phenol group. All patients were followed-up for three months and observed for “free of bleeding” or “persistent bleeding.” Pain, pruritus and patient satisfaction following the procedure was also assessed. Results: A total of 150 patients were enrolled, 75 in each group. At the end of the first sclerotherapy session with polidocanol, 60.6% of patients versus 38.1% in phenol group had stopped per rectal bleeding (p=0.009). After the second sclerotherapy session, 94.7% of patients in the polidocanol group and 84% of patients in the phenol group were treated successfully. Polidocanol group required significantly fewer treatment sessions than the phenol group (1.39±0.49 vs. 1.62±0.49; p=0.035), and the total volume of injected sclerosant was also less (3.30±0.96 mL vs. 4.86±1.46 mL; p=0.001). The patient satisfaction was 87% in polidocanol group versus 73% in phenol group (p=0.040). Conclusion: 3% polidocanol is safe and more effective than 5% phenol in oil when used as injection sclerotherapy in the treatment of first and second-degree internal hemorrhoids.
- Open Access
- 1 January 2019
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 13 (3) , 596-600
Microcuff pediatric endotracheal tubes: Evaluation of cuff sealing pressure, fiber-optic assessment of tube tip, and cuff position by ultrasonography
Background: Use of uncuffed tubes causes lots of morbidity, and there is a surge in the use of microcuff pediatric endotracheal tubes. These tubes are not evaluated in the Indian population. Aims: The study aimed to evaluate the pediatric microcuff endotracheal tubes in terms of cuff sealing pressure, fiber-optic assessment of tube tip, and cuff position to assess postextubation airway morbidity. Settings and Design: Study design involves follow-up analytical study. Subjects and Methods: Thirty-four children in the age group of 2–12 years were studied. Patients with leak pressure >20 cm H2O were exchanged with smaller size tube and excluded. Cuff pressure, fiber-optic assessment of tube tip to carina distance in neutral and flexion, ultrasound assessment of cuff position, and postextubation airway morbidity were assessed. Statistical Analysis Used: Parameters expressed as the median with the interquartile range. Nonparametric data were analyzed using the Wilcoxon signed-rank test. Results: The tracheal leak pressure was 2O (median 14.5 cm H2O) in 30 children. Tube exchange was required in four patients. A complete seal was achieved in 30 patients with cuff pressures ranging from 6 to 8.25 cm of H2O (median 8 cm of H2O). The median caudal displacement is 0.8 cm (0.47–1.22 cm) with flexion. There was no airway-related morbidity in any of these patients. Conclusions: The microcuff pediatric endotracheal tubes when used according to the age-based formula had a higher tube exchange rate in our study population. However, in children in whom the tube size was appropriate, the tubes provided good sealing without increasing airway morbidity. Further studies with a larger sample size might be required to confirm the findings.
- 1 January 2019
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 13 (3) , 596-600
Open AccessMicrocuff pediatric endotracheal tubes: Evaluation of cuff sealing pressure, fiber-optic assessment of tube tip, and cuff position by ultrasonography
Background: Use of uncuffed tubes causes lots of morbidity, and there is a surge in the use of microcuff pediatric endotracheal tubes. These tubes are not evaluated in the Indian population. Aims: The study aimed to evaluate the pediatric microcuff endotracheal tubes in terms of cuff sealing pressure, fiber-optic assessment of tube tip, and cuff position to assess postextubation airway morbidity. Settings and Design: Study design involves follow-up analytical study. Subjects and Methods: Thirty-four children in the age group of 2–12 years were studied. Patients with leak pressure >20 cm H2O were exchanged with smaller size tube and excluded. Cuff pressure, fiber-optic assessment of tube tip to carina distance in neutral and flexion, ultrasound assessment of cuff position, and postextubation airway morbidity were assessed. Statistical Analysis Used: Parameters expressed as the median with the interquartile range. Nonparametric data were analyzed using the Wilcoxon signed-rank test. Results: The tracheal leak pressure was 2O (median 14.5 cm H2O) in 30 children. Tube exchange was required in four patients. A complete seal was achieved in 30 patients with cuff pressures ranging from 6 to 8.25 cm of H2O (median 8 cm of H2O). The median caudal displacement is 0.8 cm (0.47–1.22 cm) with flexion. There was no airway-related morbidity in any of these patients. Conclusions: The microcuff pediatric endotracheal tubes when used according to the age-based formula had a higher tube exchange rate in our study population. However, in children in whom the tube size was appropriate, the tubes provided good sealing without increasing airway morbidity. Further studies with a larger sample size might be required to confirm the findings.
- Open Access
- 1 January 2017
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 11 (2) , 532-533
A modified insertion technique of ambu AuraGain™ laryngeal airway, a third-generation supraglottic airway to reduce the oral mucosal injury
Anesth Essays Res, Official publication of Pan Arab Federation of Societies of Anesthesiologists
- 1 January 2017
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 11 (2) , 532-533
Open AccessA modified insertion technique of ambu AuraGain™ laryngeal airway, a third-generation supraglottic airway to reduce the oral mucosal injury
Anesth Essays Res, Official publication of Pan Arab Federation of Societies of Anesthesiologists
- Open Access
- 1 January 2017
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 8 (1) , 19
Comparison of intubation success and glottic visualization using King Vision and C-MAC videolaryngoscopes in patients with cervical spine injuries with cervical immobilization: A randomized clinical trial
Glottic visualization can be difficult with cervical immobilization in patients with cervical spine injury. Indirect laryngoscopes may provide better glottic visualization in these groups of patients. Hence, we compared King Vision videolaryngoscope, C-MAC videolaryngoscope for endotracheal intubation in patients with proven/suspected cervical spine injury. After standard induction of anesthesia, 135 patients were randomized into three groups: group C (conventional C-MAC videolaryngoscope), group K (King Vision videolaryngoscope), and group D (D blade C-MAC videolaryngoscope). Cervical immobilization was maintained with Manual in line stabilization with anterior part of cervical collar removed. First pass intubation success, time for intubation, and glottic visualization (Cormack - Lehane grade and percentage of glottic opening) were noted. Intubation difficulty score (IDS) was used for grading difficulty of intubation. Five-point Likert scale was used for ease of insertion of laryngoscope. First attempt success rate were 100% (45/45), 93.3% (42/45), and 95.6% (43/45) in patients using conventional C-MAC, King Vision, and D blade C-MAC videolaryngoscopes, respectively. Time for intubation in seconds was significantly faster with conventional C-MAC videolaryngoscope (23.3 ± 4.7) compared to D blade C-MAC videolaryngoscope (26.7 ± 7.1), whereas conventional C-MAC and King Vision were comparable (24.9 ± 7.2). Good grade glottic visualization was obtained with all the three videolaryngoscopes. All the videolaryngoscopes provided good glottic visualization and first attempt success rate. Conventional C-MAC insertion was significantly easier. We conclude that all the three videolaryngoscopes can be used effectively in patients with cervical spine injury.
- 1 January 2017
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 8 (1) , 19
Open AccessComparison of intubation success and glottic visualization using King Vision and C-MAC videolaryngoscopes in patients with cervical spine injuries with cervical immobilization: A randomized clinical trial
Glottic visualization can be difficult with cervical immobilization in patients with cervical spine injury. Indirect laryngoscopes may provide better glottic visualization in these groups of patients. Hence, we compared King Vision videolaryngoscope, C-MAC videolaryngoscope for endotracheal intubation in patients with proven/suspected cervical spine injury. After standard induction of anesthesia, 135 patients were randomized into three groups: group C (conventional C-MAC videolaryngoscope), group K (King Vision videolaryngoscope), and group D (D blade C-MAC videolaryngoscope). Cervical immobilization was maintained with Manual in line stabilization with anterior part of cervical collar removed. First pass intubation success, time for intubation, and glottic visualization (Cormack - Lehane grade and percentage of glottic opening) were noted. Intubation difficulty score (IDS) was used for grading difficulty of intubation. Five-point Likert scale was used for ease of insertion of laryngoscope. First attempt success rate were 100% (45/45), 93.3% (42/45), and 95.6% (43/45) in patients using conventional C-MAC, King Vision, and D blade C-MAC videolaryngoscopes, respectively. Time for intubation in seconds was significantly faster with conventional C-MAC videolaryngoscope (23.3 ± 4.7) compared to D blade C-MAC videolaryngoscope (26.7 ± 7.1), whereas conventional C-MAC and King Vision were comparable (24.9 ± 7.2). Good grade glottic visualization was obtained with all the three videolaryngoscopes. All the videolaryngoscopes provided good glottic visualization and first attempt success rate. Conventional C-MAC insertion was significantly easier. We conclude that all the three videolaryngoscopes can be used effectively in patients with cervical spine injury.
- Open Access
- 1 January 2016
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 10 (1) , 111-3
Obstetric hemorrhage in a case of hypertrophic obstructive cardiomyopathy with automatic implantable cardioverter defibrillator: Anaesthesia and intensive care management
The physiological changes occurring during pregnancy and labor may reveal or exacerbate the symptoms of hypertrophic obstructive cardiomyopathy (HOCM). The addition of obstetric hemorrhage to this presents a unique challenge to the anesthesiologists and intensivists managing these patients in the operation theatres and the Intensive Care Units. Here we present a case of HOCM with automatic implantable cardioverter defibrillator in situ and postpartum hemorrhagic shock.
- 1 January 2016
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 10 (1) , 111-3
Open AccessObstetric hemorrhage in a case of hypertrophic obstructive cardiomyopathy with automatic implantable cardioverter defibrillator: Anaesthesia and intensive care management
The physiological changes occurring during pregnancy and labor may reveal or exacerbate the symptoms of hypertrophic obstructive cardiomyopathy (HOCM). The addition of obstetric hemorrhage to this presents a unique challenge to the anesthesiologists and intensivists managing these patients in the operation theatres and the Intensive Care Units. Here we present a case of HOCM with automatic implantable cardioverter defibrillator in situ and postpartum hemorrhagic shock.
- Open Access
- 11 January 2015
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2015, 1-7
Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial
Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel.Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left). The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2were noted in all positions.Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation), lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups.Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.
- 11 January 2015
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2015, 1-7
Open AccessInfluence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial
Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel.Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left). The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2were noted in all positions.Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation), lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups.Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.