Cecilia Murrugarra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cecilia Murrugarra has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
- Santiago Noriega Alvarez
Universidad El Bosque
3 shared publications A. Campos-Fauth
2 shared publicationsA. Carramiñana
2 shared publicationsA. De Castro
2 shared publicationsA. Jaimes
2 shared publicationsA. Martinez-Mendez
2 shared publications
Latest Publications
- 8 October 2020
- Published by Springer Nature
- p. 314-326
Sensor Network for Bipolar sEMG Detection and Angular Measurement for the Characterization of Foot Drop Pathology
- 8 October 2020
- Published by Springer Nature
- p. 314-326
Sensor Network for Bipolar sEMG Detection and Angular Measurement for the Characterization of Foot Drop Pathology
- 11 August 2020
- Published by Springer Nature
- p. 384-393
Kinematic Model Analysis and ROS Control of Cable Driven Continuous Robot Manipulator
- 11 August 2020
- Published by Springer Nature
- p. 384-393
Kinematic Model Analysis and ROS Control of Cable Driven Continuous Robot Manipulator
- 9 October 2019
- Published by Springer Nature
- p. 379-393
A Wireless, Modular and Wearable System for the Recognition and Assessment of Foot Drop Pathology
- 9 October 2019
- Published by Springer Nature
- p. 379-393
A Wireless, Modular and Wearable System for the Recognition and Assessment of Foot Drop Pathology
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Electronic Sensing System for Bipolar sEMG Detection and Angular Measurement for the Characterization of Foot Drop Pathology
Objective: It is common that during medical consultancies, work, and time are spent to characterize physical pathologies; this can optimize recovery times and rehabilitation opportunities. This research work was to develop a portable and technological prototype that allowed to perform the bipolar surface electromyography (sEMG) detection for the Tibialis Anterior (TA) and Peroneus Longus (PL) muscles and angular displacement measurements of the ankle-foot joint for the characterization of Foot Drop (FD) pathology. Method: An electronic system was designed and developed around a Central Processing Unit (CPU) responsible for receiving the sensors measurements to then assemble data packets for storage and transmission. The bipolar sEMG detection is carried out through an analogous conditioning module consisting of instrumentation, filtering, and amplification stages. This unit allows for obtaining the raw, rectified, and envelope signal. The angular displacement measurement is accomplished with an IMU inertial measurement system. Results: A statistical analysis was achieved to validate the precision of the measurements regard to commercial instruments; likewise, a robust analysis was implemented both in the time domain and in the frequency domain for bipolar sEMG detection, to assess the energetic distribution of the TA and PL muscle contractions. Conclusions: The data collected and the experimental platform show the great potential that the electronic system has to measure physiological variables in real-time, affirming its operation and technical capabilities. Importance: By miniaturizing the size of the equipment, making it completely wireless and improving the processing capacity, the developed system opens a new viewpoint in the measurement of physiological variables for medical purposes and applications.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Electronic Sensing System for Bipolar sEMG Detection and Angular Measurement for the Characterization of Foot Drop Pathology
Objective: It is common that during medical consultancies, work, and time are spent to characterize physical pathologies; this can optimize recovery times and rehabilitation opportunities. This research work was to develop a portable and technological prototype that allowed to perform the bipolar surface electromyography (sEMG) detection for the Tibialis Anterior (TA) and Peroneus Longus (PL) muscles and angular displacement measurements of the ankle-foot joint for the characterization of Foot Drop (FD) pathology. Method: An electronic system was designed and developed around a Central Processing Unit (CPU) responsible for receiving the sensors measurements to then assemble data packets for storage and transmission. The bipolar sEMG detection is carried out through an analogous conditioning module consisting of instrumentation, filtering, and amplification stages. This unit allows for obtaining the raw, rectified, and envelope signal. The angular displacement measurement is accomplished with an IMU inertial measurement system. Results: A statistical analysis was achieved to validate the precision of the measurements regard to commercial instruments; likewise, a robust analysis was implemented both in the time domain and in the frequency domain for bipolar sEMG detection, to assess the energetic distribution of the TA and PL muscle contractions. Conclusions: The data collected and the experimental platform show the great potential that the electronic system has to measure physiological variables in real-time, affirming its operation and technical capabilities. Importance: By miniaturizing the size of the equipment, making it completely wireless and improving the processing capacity, the developed system opens a new viewpoint in the measurement of physiological variables for medical purposes and applications.
- 13 September 2018
- Published by Springer Nature
- p. 395-407
A Test Bed to Measure Transverse Deflection of a Flexible Link Manipulator
- 13 September 2018
- Published by Springer Nature
- p. 395-407
A Test Bed to Measure Transverse Deflection of a Flexible Link Manipulator
- Open Access
- 24 August 2018
- Published by Universidad de Pamplona in BISTUA REVISTA DE LA FACULTAD DE CIENCIAS BASICAS
- Vol. 17 (1)
Arquitectura de un Dispositivo no Invasivo para el Seguimiento de la Conservación de Alimentos en Empaques Inteligentes
Este estudio está centrado en plantear una arquitectura del hardware de un dispositivo electrónico que sirve para el diagnóstico de la conservación de las carnes envasadas con empaques inteligentes, el grupo de trabajo está conformado por un equipo multidisciplinario que es capaz de realizar la extracción y caracterización de los antioxidantes de la mora, fabricar y caracterizar el gel a partir de almidón o alginato de mora, que es usado en el empaque de alimento de modo que se puede realizar el reconocimiento de los cambios de color del gel y conocer la variación de la composición del gel al estar en contacto con el alimento. Para esta fase fue necesario desarrollar un dispositivo electrónico no invasivo, capaz de leer los cambios del color del gel. Como resultado preliminar se realizaron pruebas de calibración y caracterización de la arquitectura propuesta basada en el sensor conversor de luz a frecuencia TCS 3210/3200. Con esta arquitectura se identificaron los cambios de coloración del gel en un empaque inteligente, para finalmente parametrizar otras variables ambientales que es susceptible a cambios en la variación del pH del empaque inteligente.
- 24 August 2018
- Published by Universidad de Pamplona in BISTUA REVISTA DE LA FACULTAD DE CIENCIAS BASICAS
- Vol. 17 (1)
Open AccessArquitectura de un Dispositivo no Invasivo para el Seguimiento de la Conservación de Alimentos en Empaques Inteligentes
Este estudio está centrado en plantear una arquitectura del hardware de un dispositivo electrónico que sirve para el diagnóstico de la conservación de las carnes envasadas con empaques inteligentes, el grupo de trabajo está conformado por un equipo multidisciplinario que es capaz de realizar la extracción y caracterización de los antioxidantes de la mora, fabricar y caracterizar el gel a partir de almidón o alginato de mora, que es usado en el empaque de alimento de modo que se puede realizar el reconocimiento de los cambios de color del gel y conocer la variación de la composición del gel al estar en contacto con el alimento. Para esta fase fue necesario desarrollar un dispositivo electrónico no invasivo, capaz de leer los cambios del color del gel. Como resultado preliminar se realizaron pruebas de calibración y caracterización de la arquitectura propuesta basada en el sensor conversor de luz a frecuencia TCS 3210/3200. Con esta arquitectura se identificaron los cambios de coloración del gel en un empaque inteligente, para finalmente parametrizar otras variables ambientales que es susceptible a cambios en la variación del pH del empaque inteligente.
- Open Access
- 1 January 2018
- Published by INSTICC
- p. 221-228
Constant Curvature Kinematic Model Analysis and Experimental Validation for Tendon Driven Continuum Manipulators
- 1 January 2018
- Published by INSTICC
- p. 221-228
Open AccessConstant Curvature Kinematic Model Analysis and Experimental Validation for Tendon Driven Continuum Manipulators