  • Light transmission and deposition rates in combustible dust clouds

    by J. Kelly Thomas

    A commonly applied “rule of thumb” for combustible dust is that a light bulb would be nearly obscured by a 6‐foot‐thick cloud of dust if the dust density was near that required to be explosible (i.e., the minimum explosible concentration [MEC]). This heuristic is based on Eckhoff's normative text on this topic: “a cloud of 40 g/m 3 of coal dust in air is so dense that a glowing 25‐W lightbulb can hardly be seen through a dust cloud 2 m thick.” The coal dust cloud described by Eckhoff would be close to the MEC. This heuristic is well known, and the author has used it repeatedly to illustrate how dense a dust cloud must be to be explosible. This paper demonstrates the heuristic is correct by evaluating light transmission fractions for combustible dust clouds over a range of densities and thicknesses. Large‐scale open‐air tests are presented to illustrate the appearance of an explosible dust cloud. It is also shown that horizontal surface dust deposition rates at cloud densities well below the MEC would create an intolerable housekeeping burden, and that the highest density tolerable from a worker respiratory protection standpoint is over 3 orders of magnitude less than the MEC.

  • Very lean hydrogen vapor cloud explosion testing

    by Darren R. Malik, W. B. Lowry, E. Vivanco, J. K. Thomas

    Hydrogen is a key energy carrier for modern society. The breaking of the hydrogen bonds within traditional hydrocarbon molecules has been the primary mode of energy utilization since the industrial revolution. An increased focus on “net‐zero” greenhouse gas emissions, specifically carbon dioxide and methane, has resulted in a global push for lower carbon energy vectors, including pure hydrogen. Accurately modeling the dispersion, fire, and explosion hazards associated with new and existing hydrogen production, distribution and transportation networks, and consumption is a key component to the safe expansion of these networks. BakerRisk performed a series of very lean hydrogen‐air vapor cloud explosion (VCE) tests as part of an internal research effort. The goal of these tests was to better understand the VCE hazards associated with very lean hydrogen‐air mixtures (≤14% H2). Flame speeds and blast loads were measured using high‐speed video and an array of dynamic pressure transducers. This paper discusses the test setup and test results, including a comparison with data from prior tests. The measured flame speeds are compared to those predicted using computational fluid dynamics analysis and referenced to deflagration‐to‐detonation criteria. Discussion regarding the application of these test results to facility siting studies is also provided.


  • Facility siting ‐ negotiating the minefield of “maximum credible event”

    by Kristen Graham, J. Kelly Thomas

    The purpose of this paper is to provide a case study that compares the results from a consequence‐based facility siting study (FSS) limited to a specified release size as the maximum credible event (MCE) versus a risk‐based study with a range of release sizes and associated frequencies. The results are intended to highlight potential differences in the building siting decisions made using a consequence‐based approach with a limited MCE versus those made with a risk‐based approach. Most recommended practices and other FSS guidance documents advise evaluating MCEs for an FSS. However, there can be uncertainty in MCE selection and the values used in industry span a considerable range. Arguments for limiting the MCE in a consequence‐based FSS to a 2‐in. release include that most accidental releases (i.e., > 95%) are smaller and that a 2‐in. release size is the largest that provides actionable information upon which siting decisions can be made. However, a number of well‐known incidents in industry involve releases larger than 2‐in., which introduces uncertainty as to a reasonable upper‐bound for an MCE. The use of a risk‐based FSS approach effectively eliminates the decision regarding release size since this approach aggregates the full range of operational scenarios and release sizes along with the associated likelihood of failure. Based on the MCE scenario(s) employed and the criteria selected, consequence‐based and risk‐based FSS evaluations for a given site may lead to very different conclusions as to which buildings are considered safe and what types of mitigation actions should be taken.


  • Historical overview of facility siting

    by Cheryl Grounds, Mike Moosemiller, James Kelly Thomas

    Over the years, the term “facility siting” has had many meanings, has been conducted for varying, but related purposes, and has been performed with ever‐increasing degrees of sophistication following the advancement in computing capabilities. This paper describes the history of facility siting in terms of the industry events, resulting regulations and standards, improvements in modeling techniques, and expansion of computing power that have driven the changes.


  • Hydrogen jet vapor cloud explosion: A model for predicting blast size and application to risk assessment

    by Simon Jallais, Elena Vyazmina, Derek Miller, J. Kelly Thomas

    Releases of hydrogen at elevated pressures form turbulent jets in unconfined & uncongested regions may trigger vapor cloud explosion (VCE) as well as jet fire hazards. In the case of a delayed ignition of an unconfined & uncongested jet the turbulence induced by the jet release can lead to flame speeds sufficient to produce damaging blast loads, even in the absence of confinement or congestion. The VCE hazard posed by such high‐pressure hydrogen releases is not well‐recognized.The authors have previously presented test data and computational fluid dynamic (CFD) modeling analyses which characterize high pressure hydrogen releases and the associated VCE hazard in unconfined & uncongested regions. The current paper provides an overview of this VCE hazard. It presents both CFD simulations and a new simplified method. The new method determines the blast strength based on a blast curve method (i.e., TNO multienergy or BST) with the strength index correlated to the mass flow rate of the accidental release. The paper discusses also the implications of such events for building siting analyses and risk assessments. © 2018 American Institute of Chemical Engineers Process Process Saf Prog 37:397–410, 2018


  • Elongated VCE blast waves and structural response

    by Jihui Geng, Thomas Mander, J. Kelly Thomas, Quentin Baker

    Elongated congested volumes are common at chemical processing and petroleum refining facilities due to the arrangement of processing units, but there have been relatively few evaluations reported for the blast loads produced by elongated vapor cloud explosions (VCEs). The accidental VCE that occurred at the Buncefield, UK facility in 2005 involved an elongated congested volume formed by the trees and undergrowth along a portion of the site boundary. Some of near‐field damage indicators present at the Buncefield site could not be reasonably explained using existing standard VCE blast load prediction techniques that are based on an assumption that the congested volume filled with flammable gas cloud is hemispherical and located at grade level.This paper summarizes recent work to define the characteristics associated with elongated congested volume VCEs and identify differences relative to standard VCEs involving compact congested volume geometries. The main conclusions from this work with regard to the blast wave shape for an elongated congested volume deflagration are: (1) the blast wave behaves as an acoustic wave along the long axis, (2) the blast wave has a very quick transition from the positive phase peak pressure to the negative phase peak pressure (i.e., quick relative to the positive phase duration), and (3) the magnitude of the pressure drop between the peak positive and negative pressures diminishes quickly with distance outside the congested volume. These observations are not consistent with the behavior of a compact congested volume geometry VCE blast wave.Deflagration and deflagration‐to‐detonation transition (DDT) regimes were also identified for unconfined elongated congested volume VCEs as a function of the normalized flame travel distance and flame speed. These regimes were verified with existing test data, including data from the on‐going RPSEA test program. These observations and the DDT regime identification provide a frame of reference to develop a better understanding of elongated congested volume VCEs.Generic structures, with properties typical of conventional construction, were analyzed to illustrate the effect of the elongated congested volume VCE blast loads on structural response. The results show that, for an elongated congested volume VCE, a high flame speed deflagration may result in more severe structural response in the near‐field than for a detonation (i.e., due to a DDT). These results provide an alternative near‐field damage indicator analysis approach for the investigation of elongated congested volume VCE incidents. © 2017 American Institute of Chemical Engineers Process Saf Prog 37: 283–293, 2018