Prashant P. Bansod
Research Subjects
Prashant P. Bansod has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Abhay Kumar
School of Electronics, Devi Ahilya University, Indore, India
6 shared publications - Radhe Shyam Gamad
Department of Electronics and Instrumentation, Shri Govind Ram Sakseria Institute of Technology and Science, Indore 452002, India
5 shared publications Nitin Burkule
Jupiter Hospital , Thane, 400076, India
4 shared publications- Vaishali Narendra Naik
Department of Electronics and Telecommunication Engineering, Shri Govindram Sakseria Institute of Technology and Science, Indore, India
4 shared publications Vibha Tiwari
3 shared publications- Anju Lata Yadav
Electronics and Telecomm Engg., Shri G.S. Institute of Technology and Science, Indore, India
2 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 8960
A Novel Non-Invasive Technique for Assessing Blood Glucose Concentrations
In the present circumstances, it is exceedingly hard for people to monitor their blood sugar levels on a regular basis. Checking the blood glucose levels of diabetic individuals is often an essential part of managing diabetes. Now, this means repeatedly pricking your finger and bleeding. Non-invasive (NI) detection methods are anticipated to have several benefits, including the elimination of discomfort, avoidance of sharp items and biohazardous chemicals, the possibility of more frequent testing, and, therefore, better regulation of glucose levels. Infrared technology has become one of the most important technologies for the development of the NI self-monitoring of blood glucose (NI-SMBG). One good thing about this approach is that it does not need any chemicals and can employ fiber optic parts. So, only insulators come into direct contact with the skin. Also, the spectrometer may be made without any moving parts, which makes it strong. For this method to be effective, the spectral signature of glucose must be uniquely identifiable from all other chemical constituents in the human body, and this glucose-specific data must be obtained with a sufficiently high signal-to-noise ratio to facilitate reliable differentiation between glucose-dependent signals and those generated by other matrix components. In this paper, we have addressed the issue of infrared signature analysis for blood glucose, which has been done in the infrared region of the electromagnetic spectrum. Firstly, the analysis is carried out for the glucose molecule only. Later, looking at the presence of numerous other analyses in whole blood, tissues, skin, etc., for in vivo measurement of blood glucose, a set of wavelengths is identified on which in vivo measurements can be done with minimal interference from other body fluid analyses. Absorption of spectroscopic information collected on these wavelengths, along with a suitable calibration model, can be a step ahead for in vivo NI glucose measurement. The main innovative features of the present study are non-invasive glucose sensing, Patient-friendly and continuous monitoring opportunity, Progress towards wearable and real-time diagnostics, Clinical and Social Relevance and Contribution to Research. The paper investigates a non-invasive infrared-based methodology for glucose estimation, focusing on the spectral response characteristics of glucose in biological tissue. While the complexity of tissue spectroscopy involves potential interference from other biomolecules, the present work emphasizes the feasibility of glucose detection without invasive blood extraction, rather than conducting a dedicated interference-analysis study.
- 9 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 8960
Open AccessA Novel Non-Invasive Technique for Assessing Blood Glucose Concentrations
In the present circumstances, it is exceedingly hard for people to monitor their blood sugar levels on a regular basis. Checking the blood glucose levels of diabetic individuals is often an essential part of managing diabetes. Now, this means repeatedly pricking your finger and bleeding. Non-invasive (NI) detection methods are anticipated to have several benefits, including the elimination of discomfort, avoidance of sharp items and biohazardous chemicals, the possibility of more frequent testing, and, therefore, better regulation of glucose levels. Infrared technology has become one of the most important technologies for the development of the NI self-monitoring of blood glucose (NI-SMBG). One good thing about this approach is that it does not need any chemicals and can employ fiber optic parts. So, only insulators come into direct contact with the skin. Also, the spectrometer may be made without any moving parts, which makes it strong. For this method to be effective, the spectral signature of glucose must be uniquely identifiable from all other chemical constituents in the human body, and this glucose-specific data must be obtained with a sufficiently high signal-to-noise ratio to facilitate reliable differentiation between glucose-dependent signals and those generated by other matrix components. In this paper, we have addressed the issue of infrared signature analysis for blood glucose, which has been done in the infrared region of the electromagnetic spectrum. Firstly, the analysis is carried out for the glucose molecule only. Later, looking at the presence of numerous other analyses in whole blood, tissues, skin, etc., for in vivo measurement of blood glucose, a set of wavelengths is identified on which in vivo measurements can be done with minimal interference from other body fluid analyses. Absorption of spectroscopic information collected on these wavelengths, along with a suitable calibration model, can be a step ahead for in vivo NI glucose measurement. The main innovative features of the present study are non-invasive glucose sensing, Patient-friendly and continuous monitoring opportunity, Progress towards wearable and real-time diagnostics, Clinical and Social Relevance and Contribution to Research. The paper investigates a non-invasive infrared-based methodology for glucose estimation, focusing on the spectral response characteristics of glucose in biological tissue. While the complexity of tissue spectroscopy involves potential interference from other biomolecules, the present work emphasizes the feasibility of glucose detection without invasive blood extraction, rather than conducting a dedicated interference-analysis study.
- Open Access
- 15 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4208
Convolution Neural Network Based Multi-Label Disease Detection Using Smartphone Captured Tongue Images
Purpose: Tongue image analysis for disease diagnosis is an ancient, traditional, non-invasive diagnostic technique widely used by traditional medicine practitioners. Deep learning-based multi-label disease detection models have tremendous potential for clinical decision support systems because they facilitate preliminary diagnosis. Methods: In this work, we propose a multi-label disease detection pipeline where observation and analysis of tongue images captured and received via smartphones assist in predicting the health status of an individual. Subjects, who consult collaborating physicians, voluntarily provide all images. Images thus acquired are first and foremost classified either into a diseased or a normal category by a 5-fold cross-validation algorithm using a convolutional neural network (MobileNetV2) model for binary classification. Once it predicts the diseased label, the disease prediction algorithm based on DenseNet-121 uses the image to diagnose single or multiple disease labels. Results: The MobileNetV2 architecture-based disease detection model achieved an average accuracy of 93% in distinguishing between diseased and normal, healthy tongues, whereas the multilabel disease classification model produced more than 90% accurate results for the disease class labels considered, strongly indicating a successful outcome with the smartphone-captured image dataset. Conclusion: AI-based image analysis shows promising results, and an extensive dataset could provide further improvements to this approach. Experimenting with smartphone images opens a great opportunity to provide preliminary health status to individuals at remote locations as well, prior to further treatment and diagnosis, using the concept of telemedicine.
- 15 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4208
Open AccessConvolution Neural Network Based Multi-Label Disease Detection Using Smartphone Captured Tongue Images
Purpose: Tongue image analysis for disease diagnosis is an ancient, traditional, non-invasive diagnostic technique widely used by traditional medicine practitioners. Deep learning-based multi-label disease detection models have tremendous potential for clinical decision support systems because they facilitate preliminary diagnosis. Methods: In this work, we propose a multi-label disease detection pipeline where observation and analysis of tongue images captured and received via smartphones assist in predicting the health status of an individual. Subjects, who consult collaborating physicians, voluntarily provide all images. Images thus acquired are first and foremost classified either into a diseased or a normal category by a 5-fold cross-validation algorithm using a convolutional neural network (MobileNetV2) model for binary classification. Once it predicts the diseased label, the disease prediction algorithm based on DenseNet-121 uses the image to diagnose single or multiple disease labels. Results: The MobileNetV2 architecture-based disease detection model achieved an average accuracy of 93% in distinguishing between diseased and normal, healthy tongues, whereas the multilabel disease classification model produced more than 90% accurate results for the disease class labels considered, strongly indicating a successful outcome with the smartphone-captured image dataset. Conclusion: AI-based image analysis shows promising results, and an extensive dataset could provide further improvements to this approach. Experimenting with smartphone images opens a great opportunity to provide preliminary health status to individuals at remote locations as well, prior to further treatment and diagnosis, using the concept of telemedicine.
- Open Access
- 8 April 2024
- Published by MDPI AG in Preprints.org
Convolution Neural Network Based Multi- Label Disease Detection using Tongue Images
Purpose: Tongue image analysis for disease diagnosis is an ancient traditional non-invasive diagnosis technique widely used by traditional medicine practitioners. Deep Learning based multi-label disease detection models offer tremendous potential to clinical decision support systems, by facilitating preliminary diagnosis. Methods: In this work, we propose a multi-label disease detection pipeline, where in observation and analysis of tongue images captured and received via smartphones assist in predicting the health status of an individual. All images are voluntarily given by subjects consulting collaborating physicians. Images thus acquired are first and foremost classified either into a diseased or a normal category by a 5-fold cross-validation algorithm using a convolution neural network (MobileNetV2) model for binary classification. Once the diseased label is predicted, the image is used to diagnose multiple diseases using the prediction algorithm based on DenseNet121. Results: Average accuracy of 93 % was achieved in classifying diseased from normal healthy tongue by detection model with MobileNetV2 architecture. Multilabel disease classification produced more than 90% accurate results for the seven class labels considered. Conclusion: AI based image analysis shows promising results and an extensive dataset could provide further improvements to this approach. Rather than employing high-cost sophisticated image capturing setup, experimenting with smartphone images opens opportunity to provide preliminary health status to individuals on smartphone prior to further line of treatment and diagnosis.
- 8 April 2024
- Published by MDPI AG in Preprints.org
Open AccessConvolution Neural Network Based Multi- Label Disease Detection using Tongue Images
Purpose: Tongue image analysis for disease diagnosis is an ancient traditional non-invasive diagnosis technique widely used by traditional medicine practitioners. Deep Learning based multi-label disease detection models offer tremendous potential to clinical decision support systems, by facilitating preliminary diagnosis. Methods: In this work, we propose a multi-label disease detection pipeline, where in observation and analysis of tongue images captured and received via smartphones assist in predicting the health status of an individual. All images are voluntarily given by subjects consulting collaborating physicians. Images thus acquired are first and foremost classified either into a diseased or a normal category by a 5-fold cross-validation algorithm using a convolution neural network (MobileNetV2) model for binary classification. Once the diseased label is predicted, the image is used to diagnose multiple diseases using the prediction algorithm based on DenseNet121. Results: Average accuracy of 93 % was achieved in classifying diseased from normal healthy tongue by detection model with MobileNetV2 architecture. Multilabel disease classification produced more than 90% accurate results for the seven class labels considered. Conclusion: AI based image analysis shows promising results and an extensive dataset could provide further improvements to this approach. Rather than employing high-cost sophisticated image capturing setup, experimenting with smartphone images opens opportunity to provide preliminary health status to individuals on smartphone prior to further line of treatment and diagnosis.
- Open Access
- 15 December 2022
- Published by EDP Sciences in ITM Web of Conferences
- Vol. 50, 02005
64 Bit Binary Counter with Minimal Clock Period
Novel rapid formations of synchronous binary counting with single minimum period of counting for practical counters are developed in this project. A synchronous binary counter is required in many applications since it is rapid, also can help a broad bit-width. Basically, because of massive fan-outs and extensive carry chains, earlier counters have a limited counting rate, mainly when size of the counter is not modest. It employs a single bit Johnson counter to decrease whole hardware complications, then copy it to lessen the propagation latency caused by huge fan-outs. In this paper, re programmable the clock utilized in it for various applications functioning at different clock rates and there’ll be a variation within the delay values because the clock is reprogrammed the critical may varies for various rates. The counter output results are obtained for various bit up to 64 and therefore the design provides various clock rates with variations in area and delay.
- 15 December 2022
- Published by EDP Sciences in ITM Web of Conferences
- Vol. 50, 02005
Open Access64 Bit Binary Counter with Minimal Clock Period
Novel rapid formations of synchronous binary counting with single minimum period of counting for practical counters are developed in this project. A synchronous binary counter is required in many applications since it is rapid, also can help a broad bit-width. Basically, because of massive fan-outs and extensive carry chains, earlier counters have a limited counting rate, mainly when size of the counter is not modest. It employs a single bit Johnson counter to decrease whole hardware complications, then copy it to lessen the propagation latency caused by huge fan-outs. In this paper, re programmable the clock utilized in it for various applications functioning at different clock rates and there’ll be a variation within the delay values because the clock is reprogrammed the critical may varies for various rates. The counter output results are obtained for various bit up to 64 and therefore the design provides various clock rates with variations in area and delay.
- 12 July 2022
- Published by Springer Nature
- p. 165-176
Design of Protection Circuit for Biomedical Signals Using 180 nm Technology
- 12 July 2022
- Published by Springer Nature
- p. 165-176
Design of Protection Circuit for Biomedical Signals Using 180 nm Technology
- 18 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Low Voltage Low Power Wide Supply CMOS Current Mode Bandgap Voltage Reference
We propose an efficient low voltage low power CMOS current mode bandgap voltage reference circuit for wide power supply range applications. The proposed circuit is designed in the SCL 180nm cmos process and provides a steady voltage reference of 500mV while running in the temperature range of -40°C to 125°C, as well as working normally with a large supply voltage range of 800mV to 10V. The traditional bandgap voltage reference circuit’s BJT is replaced by a MOSFET functioning in the subthreshold region, which is ideal for low voltage applications. When supplied with a 1V supply, the tempeature coefficient of the CMOS current mode bandgap reference is 85.08 ppm/°C, and an achieved line regulation is 0.13mV/V. While burning a current of 5.13μA the total power dissipation is 5.13μW and the PSRR is -105.54 dB at DC frequency.
- 18 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Low Voltage Low Power Wide Supply CMOS Current Mode Bandgap Voltage Reference
We propose an efficient low voltage low power CMOS current mode bandgap voltage reference circuit for wide power supply range applications. The proposed circuit is designed in the SCL 180nm cmos process and provides a steady voltage reference of 500mV while running in the temperature range of -40°C to 125°C, as well as working normally with a large supply voltage range of 800mV to 10V. The traditional bandgap voltage reference circuit’s BJT is replaced by a MOSFET functioning in the subthreshold region, which is ideal for low voltage applications. When supplied with a 1V supply, the tempeature coefficient of the CMOS current mode bandgap reference is 85.08 ppm/°C, and an achieved line regulation is 0.13mV/V. While burning a current of 5.13μA the total power dissipation is 5.13μW and the PSRR is -105.54 dB at DC frequency.
- Open Access
- 15 July 2021
- Published by Elsevier in Biomedical Journal
- Vol. 45 (4) , 686-695
Effect of despeckling filters on the segmentation of ultrasound common carotid artery images
- 15 July 2021
- Published by Elsevier in Biomedical Journal
- Vol. 45 (4) , 686-695
Open AccessEffect of despeckling filters on the segmentation of ultrasound common carotid artery images
- 1 January 2021
- Published by Inderscience Publishers in International Journal of Biomedical Engineering and Technology
- Vol. 36 (1) , 79
CT image reconstruction from sparse projections using adaptive total generalised variation with soft thresholding
CT imaging plays a vital role in non-invasive diagnosis and in surgical planning of critical diseases. It is essential to reduce radiation dose during CT imaging as excessive exposure may cause harm to human tissues. To reduce radiation dose, CT image is acquired using limited number of X-ray projections and then to reconstruct the image an adaptive total generalised variation (TGV) minimisation method has been proposed. The simulation results have been compared with the existing TV, TGV and TGV with hard thresholding methods. Typically two types of noises, Gaussian and Poisson distributed noises, are introduced during CT imaging process. So, these two types of noises have been added in measured samples. It is found that after applying soft thresholding and FISTA algorithm with the proposed method, better results have been obtained in noisy imaging environment. The reconstructed CT image quality has been compared using parameters like FSSIM, PSNR, NRMSE and MAE.
- 1 January 2021
- Published by Inderscience Publishers in International Journal of Biomedical Engineering and Technology
- Vol. 36 (1) , 79
CT image reconstruction from sparse projections using adaptive total generalised variation with soft thresholding
CT imaging plays a vital role in non-invasive diagnosis and in surgical planning of critical diseases. It is essential to reduce radiation dose during CT imaging as excessive exposure may cause harm to human tissues. To reduce radiation dose, CT image is acquired using limited number of X-ray projections and then to reconstruct the image an adaptive total generalised variation (TGV) minimisation method has been proposed. The simulation results have been compared with the existing TV, TGV and TGV with hard thresholding methods. Typically two types of noises, Gaussian and Poisson distributed noises, are introduced during CT imaging process. So, these two types of noises have been added in measured samples. It is found that after applying soft thresholding and FISTA algorithm with the proposed method, better results have been obtained in noisy imaging environment. The reconstructed CT image quality has been compared using parameters like FSSIM, PSNR, NRMSE and MAE.
- 15 October 2019
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 107 (4) , 561-575
QoS in WiMAX hybrid schedulers for heterogeneous traffic and their performance comparison
Worldwide Interoperability for Microwave Access (WiMAX), based on IEEE 802.16, provides first-mile wireless access for broadband users and is capable of satisfying the Quality of Service (QoS) requirements of voice, video and data traffic (triple-play services). This paper proposes two WiMAX hybrid schedulers, developed by integration of homogeneous schedulers, for providing QoS to triple-play services. The Markovian model is solved analytically to derive various performance metrics, which are then compared with an existing scheduler. The splitting of FTP traffic, before scheduling, provides improved throughput as compared to the proposed first hybrid scheduler, making this an exclusive component of the proposed second hybrid scheduler. The results show that the second proposed model provides an improvement of mandatory QoS parameters; reduction in voice traffic mean queuing delay by 68.18%, and improvement in FTP traffic throughput by 67.27% as compared to the first designed model. The first considered scheduler gives high inter-class fairness; however, it does not provide satisfactory QoS performance. The proposed hybrid schedulers are better in overall performance than other schedulers proposed recently, as they not only satisfy the QoS demands of different types of services but also improve the fairness among services.
- 15 October 2019
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 107 (4) , 561-575
QoS in WiMAX hybrid schedulers for heterogeneous traffic and their performance comparison
Worldwide Interoperability for Microwave Access (WiMAX), based on IEEE 802.16, provides first-mile wireless access for broadband users and is capable of satisfying the Quality of Service (QoS) requirements of voice, video and data traffic (triple-play services). This paper proposes two WiMAX hybrid schedulers, developed by integration of homogeneous schedulers, for providing QoS to triple-play services. The Markovian model is solved analytically to derive various performance metrics, which are then compared with an existing scheduler. The splitting of FTP traffic, before scheduling, provides improved throughput as compared to the proposed first hybrid scheduler, making this an exclusive component of the proposed second hybrid scheduler. The results show that the second proposed model provides an improvement of mandatory QoS parameters; reduction in voice traffic mean queuing delay by 68.18%, and improvement in FTP traffic throughput by 67.27% as compared to the first designed model. The first considered scheduler gives high inter-class fairness; however, it does not provide satisfactory QoS performance. The proposed hybrid schedulers are better in overall performance than other schedulers proposed recently, as they not only satisfy the QoS demands of different types of services but also improve the fairness among services.
- 9 July 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (2) , 207-226
Efficient initialisation of distance-regularised level set without re-initialisation scheme and quantitative evaluation of IMT in B mode ultrasound common carotid artery images
Segmentation of the Common Carotid Artery (CCA) wall is imperative for the estimation of the Intima Media Thickness (IMT) in B-mode longitudinal ultrasound images. IMT is considered as the prominent indicator of atherosclerosis and is defined as the distance between Lumen-Intima (LI) and Media-Adventitia (MA) interfaces of CCA vessel. This paper proposes an efficient initialisation scheme for Distance-Regularised Level Set without re-initialisation Evolution (DRLSE) method by utilising Fast Fuzzy C-Mean clustering (FFCM) technique to detect Li and MA interfaces accurately. Distance between the detected interfaces is determined by Polyline Distance Metric (PDM). Also, a quantitative and qualitative comparison among proposed method, manual method and snake method is presented. Experimental results show that the proposed method is robust in terms of region of interest selection (ROI), noise (speckle as well as salt and pepper) and images acquired from different machines. Inter-method, inter-operator and intra-operator variability have been studied by computing average, standard deviation, Coefficient of Variation (CV%) and via Wilcoxon’s signed-rank test (at p < 0.05). Reported results demonstrate close agreement between manual and proposed methods. The proposed method is semiautomatic and bears an advantage that a tight ROI is not required which encourages its use in clinical practice.
- 9 July 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (2) , 207-226
Efficient initialisation of distance-regularised level set without re-initialisation scheme and quantitative evaluation of IMT in B mode ultrasound common carotid artery images
Segmentation of the Common Carotid Artery (CCA) wall is imperative for the estimation of the Intima Media Thickness (IMT) in B-mode longitudinal ultrasound images. IMT is considered as the prominent indicator of atherosclerosis and is defined as the distance between Lumen-Intima (LI) and Media-Adventitia (MA) interfaces of CCA vessel. This paper proposes an efficient initialisation scheme for Distance-Regularised Level Set without re-initialisation Evolution (DRLSE) method by utilising Fast Fuzzy C-Mean clustering (FFCM) technique to detect Li and MA interfaces accurately. Distance between the detected interfaces is determined by Polyline Distance Metric (PDM). Also, a quantitative and qualitative comparison among proposed method, manual method and snake method is presented. Experimental results show that the proposed method is robust in terms of region of interest selection (ROI), noise (speckle as well as salt and pepper) and images acquired from different machines. Inter-method, inter-operator and intra-operator variability have been studied by computing average, standard deviation, Coefficient of Variation (CV%) and via Wilcoxon’s signed-rank test (at p < 0.05). Reported results demonstrate close agreement between manual and proposed methods. The proposed method is semiautomatic and bears an advantage that a tight ROI is not required which encourages its use in clinical practice.