SSSina Straub

Sina Straub

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sina Straub has a total of 194 co-authors. Here are the top co-authors by number of shared publications:

  • Mark E. Ladd

    Division of Medical Physics in Radiology German Cancer Research Center (DKFZ) Heidelberg Germany

    15 shared publications
  • Frederik B. Laun

    Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany

    9 shared publications
  • Julian Emmerich

    Division of Medical Physics in Radiology German Cancer Research Center (DKFZ) Heidelberg Germany

    8 shared publications
  • Julian Emmerich

    Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany

    6 shared publications
  • Erik H. Middlebrooks

    Department of Radiology Mayo Clinic Jacksonville Florida USA

    4 shared publications
  • Erin M. Westerhold

    Department of Radiology Mayo Clinic Jacksonville Florida USA

    4 shared publications

Latest Publications

  • Open Access

    Coordinate-Based fMRI Meta-Analyses of Episodic Memory Encoding and Retrieval in Depression

    by Raphaela Schöpfer, Reut Zabag, Florian Wüthrich, Romy Lorenz, Jutta Joormann, Sina Straub, Jessica Peter

  • Feasibility of Laminar Functional Quantitative Susceptibility Mapping

    by Sina Straub, Xiangzhi Zhou, Shengzhen Tao, Erin M. Westerhold, Jin Jin, Erik H. Middlebrooks

    Purpose: Layer fMRI is an increasingly utilized technique that provides insights into the laminar organization of brain activity. However, both blood‐oxygen‐level‐dependent (BOLD) fMRI and vascular space occupancy data (VASO) have certain limitations, such as bias towards larger cortical veins in BOLD fMRI and high specific absorption rate in VASO. This study aims to explore the feasibility of whole‐brain laminar functional quantitative susceptibility mapping (fQSM) compared to laminar BOLD fMRI and VASO at ultra‐high field. Methods: Data were acquired using 3D EPI techniques. Complex data were denoised with NORDIC and susceptibility maps were computed using 3D path‐based unwrapping, the variable‐kernel sophisticated harmonic artifact reduction, as well as the streaking artifact reduction for QSM algorithms. To assess layer‐specific activation, 20 layers were segmented in the somatosensory and motor cortices, obtained from a finger tapping paradigm, and further averaged into six anatomical cortical layers. The magnitude of signal change and z ‐scores were compared across layers for each technique. Results: fQSM showed the largest activation‐dependent mean susceptibility decrease in Layers II/III in M1 and Layers I/II in S1 with up to −1.3 ppb while BOLD showed the strongest mean signal increase in Layer I. Our data suggest that fQSM demonstrates less bias towards activation in superficial layers compared to BOLD. Moreover, activation‐based susceptibility change was comparable to VASO data. Conclusion: Studying whole‐brain, layer‐dependent activation with submillimeter fQSM is feasible and reduces bias towards venous drainage effects on the cortical surface compared to BOLD, thereby enabling better localization of laminar activation.

  • Open Access

    The functional neuroanatomy of event-based and time-based prospective memory, and its improvement

    by Jessica Peter, Marta Menéndez-Granda, Nadine Schmidt, Nathanael Jost, Katharina Klink, Yosuke Morishima, Sina Straub, Sebastian Horn, Matthias Kliegel, Michael Orth

    Prospective memory anchors upcoming activities in future time and space either cued externally (event-based prospective memory) or internally (time-based prospective memory). It is key to remain autonomous and can be enhanced using incentives. To examine the neuronal underpinnings of prospective memory and any performance improvement, we randomly assigned 58 healthy older participants (60-75 years old, 36 women) to time-based and focal event-based prospective memory tasks using 7T-fMRI, with or without incentives. Event-based and time-based prospective memory differ in their functional neuroanatomy. The focal event-based task required activity important for the perception of relevant changes in the environment and for adapting the focus of attention to then respond swiftly. The time-based task, in contrast, involved regions supporting cognitive control or serving as a multimodal information buffer. Incentives had no effect in time-based prospective memory but recruited brain regions important for attention thus improving cue recognition in event-based prospective memory. This highlights the differences between these two prospective memory types and the need for differential approaches depending on the type of memory demand.


  • Open Access

    Automated extraction of electrode coordinates from structural MRI to assess tDCS placement accuracy

    by Sina Straub, Raphaela Schöpfer, Sarah Godehardt, Florian Wüthrich, Jessica Peter

    Accurate electrode placement is essential for studies using transcranial direct current stimulation (tDCS) since it determines whether - and to what extent - the intended brain region was modulated. Using in-scanner tDCS, placement accuracy can be determined by extracting electrode coordinates from structural MRI and by comparing actual and intended positions. Previous studies extracted coordinates manually, which is time-consuming and prone to error. Here, we present an algorithm to automate this process. The proposed algorithm first segments electrode and electrode-gel blobs visible on MRI. It then separates this segmentation into individual electrode regions and extracts their coordinates as the centroids of these regions. Finally, coordinates are assigned to the intended target positions using linear assignment. We evaluated the algorithm with T 1 -weighted MRI data from 65 individuals acquired at diferent scanners with diferent magnetic field strengths, image resolutions, and two high-definition montages by comparing the extracted coordinates with manual annotations from two independent readers. The median localization error of the algorithm was 2.4 mm (IQR 1.5 mm). The median variability between human readers was 2.7 mm (IQR 1.7 mm). Distances between algorithm-derived coordinates and the reference were smaller than distances between readers. Our proposed algorithm obviates the need for manual electrode segmentation and allows an objective evaluation of electrode placement accuracy for in-scanner tDCS. It may be used to relate electrode position errors to stimulation efects.

  • Feasibility of submillimeter functional quantitative susceptibility mapping using 3D echo planar imaging at 7 T

    by Sina Straub, Xiangzhi Zhou, Shengzhen Tao, Erin M. Westerhold, Jin Jin, Erik H. Middlebrooks

    Quantitative susceptibility mapping (QSM) is a tool for mapping tissue susceptibility. Using QSM for functional brain mapping, it is possible to directly quantify blood‐oxygen‐level‐dependent (BOLD) susceptibility changes. This study presents a submillimeter functional QSM (fQSM) approach compared to BOLD fMRI from data acquired with 3D gradient‐echo echo planar imaging (EPI) at ultra‐high field. Complex EPI data were acquired in nine healthy subjects with varying temporal and spatial resolutions and used for BOLD fMRI and for fQSM. Right‐hand finger tapping experiments were performed as well as one measurement with intentional subject movement. Susceptibility maps were computed using 3D path‐based unwrapping, the variable‐kernel sophisticated harmonic artifact reduction for phase data, and the streaking artifact reduction for QSM algorithm. Functional data analysis included general linear modeling and computation of z‐scores. Submillimeter data were denoised using NOise reduction with DIstribution Corrected (NORDIC), which improved z‐scores in the motor cortex for fQSM and fMRI. An expected increase in BOLD fMRI signal and corresponding decrease in magnetic susceptibility was observed in sensorimotor areas during active periods. For all experiments, fQSM showed smaller activation regions compared with fMRI. The percentage of high negative t‐values localized in the cortex was higher for fQSM (52%) than for positive or negative t‐values for fMRI (45%). For the scans with intentional motion, movement exceeded the size of a voxel, but paradigm dependent signal evolution could be recovered using motion correction. In conclusion, this study demonstrates the feasibility of submillimeter whole‐brain fQSM with voxel volume of 0.53 μL. In comparison to traditional BOLD fMRI, fQSM provided improved localization of brain activation within the cortex, especially in submillimeter 3D EPI sequences.


  • Open Access

    Feasibility of laminar functional quantitative susceptibility mapping

    by Sina Straub, Xiangzhi Zhou, Shengzhen Tao, Erin M. Westerhold, Jin Jin, Erik H. Middlebrooks

    Layer fMRI is an increasingly utilized technique that provides insights into the laminar organization of brain activity. However, both blood-oxygen-level-dependent (BOLD) fMRI and vascular space occupancy data (VASO) have certain limitations, such as bias towards larger cortical veins in BOLD fMRI and high specific absorption rate in VASO. This study aims to explore the feasibility of whole-brain laminar functional quantitative susceptibility mapping (fQSM) compared to laminar BOLD fMRI and VASO at ultra-high field. Data were acquired using 3D EPI techniques. Complex data were denoised with NORDIC and susceptibility maps were computed using 3D path-based unwrapping, the variable-kernel sophisticated harmonic artifact reduction as well as the streaking artifact reduction for QSM algorithms. To assess layer-specific activation, twenty layers were segmented in the somatosensory and motor cortices, obtained from a finger tapping paradigm, and further averaged into six anatomical cortical layers. The magnitude of signal change and z-scores were compared across layers for each technique. fQSM showed the largest activation-dependent mean susceptibility decrease in Layers II/III in M1 and Layers I/ II in S1 with up to -1.3 ppb while BOLD fMRI showed the strongest mean signal increase in Layer I. Our data suggest that fQSM demonstrates less bias towards activation in superficial layers compared to BOLD fMRI. Moreover, activation-based susceptibility change was comparable to VASO data. Studying whole-brain, layer-dependent activation with submillimeter fQSM is feasible, and reduces bias towards venous drainage effects on the cortical surface compared to BOLD fMRI, thereby enabling better localization of laminar activation.


  • Top Cited Papers

    Recommended implementation of quantitative susceptibility mapping for clinical research in the brain: A consensus of the ISMRM electro‐magnetic tissue properties study group

    by QSM Consensus Organization Committee, Berkin Bilgic, Mauro Costagli, Kwok‐Shing Chan, Jeff Duyn, Christian Langkammer, Jongho Lee, Xu Li, Chunlei Liu, José P. Marques, et al.

    This article provides recommendations for implementing QSM for clinical brain research. It is a consensus of the International Society of Magnetic Resonance in Medicine, Electro‐Magnetic Tissue Properties Study Group. While QSM technical development continues to advance rapidly, the current QSM methods have been demonstrated to be repeatable and reproducible for generating quantitative tissue magnetic susceptibility maps in the brain. However, the many QSM approaches available have generated a need in the neuroimaging community for guidelines on implementation. This article outlines considerations and implementation recommendations for QSM data acquisition, processing, analysis, and publication. We recommend that data be acquired using a monopolar 3D multi‐echo gradient echo (GRE) sequence and that phase images be saved and exported in Digital Imaging and Communications in Medicine (DICOM) format and unwrapped using an exact unwrapping approach. Multi‐echo images should be combined before background field removal, and a brain mask created using a brain extraction tool with the incorporation of phase‐quality‐based masking. Background fields within the brain mask should be removed using a technique based on SHARP or PDF, and the optimization approach to dipole inversion should be employed with a sparsity‐based regularization. Susceptibility values should be measured relative to a specified reference, including the common reference region of the whole brain as a region of interest in the analysis. The minimum acquisition and processing details required when reporting QSM results are also provided. These recommendations should facilitate clinical QSM research and promote harmonized data acquisition, analysis, and reporting.


  • Open Access

    Diagnostic utility of 7T neuromelanin imaging of the substantia nigra in Parkinson’s disease

    by Dhairya A. Lakhani, Xiangzhi Zhou, Shengzhen Tao, Vishal Patel, Sijin Wen, Lela Okromelidze, Elena Greco, Chen Lin, Erin M. Westerhold, Sina Straub, et al.

    Parkinson’s disease (PD) is a prevalent neurodegenerative disorder that presents a diagnostic challenge due to symptom overlap with other disorders. Neuromelanin (NM) imaging is a promising biomarker for PD, but adoption has been limited, in part due to subpar performance at standard MRI field strengths. We aimed to evaluate the diagnostic utility of ultra-high field 7T NM-sensitive imaging in the diagnosis of PD versus controls and essential tremor (ET), as well as NM differences among PD subtypes. A retrospective case-control study was conducted including PD patients, ET patients, and controls. 7T NM-sensitive 3D-GRE was acquired, and substantia nigra pars compacta (SNpc) volumes, contrast ratios, and asymmetry indices were calculated. Statistical analyses, including general linear models and ROC curves, were employed. Twenty-one PD patients, 13 ET patients, and 18 controls were assessed. PD patients exhibited significantly lower SNpc volumes compared to non-PD subjects. SNpc total volume showed 100% sensitivity and 96.8% specificity (AUC = 0.998) for differentiating PD from non-PD and 100% sensitivity and 95.2% specificity (AUC = 0.996) in differentiating PD from ET. Contrast ratio was not significantly different between PD and non-PD groups (p = 0.07). There was also significantly higher asymmetry index in SNpc volume in PD compared to non-PD cohorts (p < 0.001). NM signal loss in PD predominantly involved the inferior, posterior, and lateral aspects of SNpc. Akinetic-rigid subtype showed more significant NM signal loss compared to tremor dominant subtype (p < 0.001). 7T NM imaging demonstrates potential as a diagnostic tool for PD, including potential distinction between subtypes, allowing improved understanding of disease progression and subtype-related characteristics.


  • Open Access

    Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI

    by Lela Okromelidze, Vishal Patel, Rahul B. Singh, Alfonso S. Lopez Chiriboga, Shengzhen Tao, Xiangzhi Zhou, Sina Straub, Erin M. Westerhold, Vivek Gupta, Amit K. Agarwal, et al.

    BACKGROUND AND PURPOSE: An early and accurate diagnosis of multiple sclerosis remains challenging in clinical neurology. Established diagnostic methods have less than desirable sensitivity and specificity. An accurate, noninvasive diagnostic test for MS could have a major impact on diagnostic criteria. We compared the frequency of detection of the central vein sign (CVS) in white matter lesions of MS and controls on 7T T2*-weighted and SWI to 3T SWI. Additionally, we assessed the diagnostic performance of 7T T2*, 7T SWI, and 3T SWI for MS. MATERIALS AND METHODS: A retrospective case-control study was performed of patients with MS having both 7T MRI and 3T MRI. A control group of patients without MS was selected. Diagnosis of MS was established by board-certified neurologists with fellowship training in autoimmune neurology in line with the 2017 McDonald criteria. Percentage of lesions with a CVS was blindly measured for each technique. Diagnostic performance was computed by sensitivity, specificity, and positive and negative likelihood ratios (LRs). RESULTS: Sixty-one patients with MS (903 lesions) and 39 controls (1088 lesions) were included. 7T T2* showed significantly more CVS (87%) than both 7T SWI (73%) and 3T SWI (31%) (all P < .001). CVS was identified in the control group in ≤6% of lesions on all sequences. Using a threshold of >40% of lesions with CVS on 7T T2* and >15% on 7T SWI, both sequences had an accuracy = 100%, sensitivity = 100%, specificity = 100%, infinite positive LR, and zero negative LR. Using an optimal threshold of >12%, 3T SWI had an accuracy = 96.0%, sensitivity = 93.4%, specificity = 100%, infinite positive LR, and negative LR = 0.066. CONCLUSIONS: 7T MRI had 100% sensitivity and specificity for the diagnosis of MS and is superior to 3T. Future revisions to MS diagnostic criteria may consider recommendations for 7T MRI and inclusion of CVS as a biomarker.


  • QSM Throughout the Body

    by Alexey V. Dimov, Jiahao Li, Thanh D. Nguyen, Alexandra G. Roberts, Pascal Spincemaille, Sina Straub, Zungho Zun, Martin R. Prince, Yi Wang

    Magnetic materials in tissue, such as iron, calcium, or collagen, can be studied using quantitative susceptibility mapping (QSM). To date, QSM has been overwhelmingly applied in the brain, but is increasingly utilized outside the brain. QSM relies on the effect of tissue magnetic susceptibility sources on the MR signal phase obtained with gradient echo sequence. However, in the body, the chemical shift of fat present within the region of interest contributes to the MR signal phase as well. Therefore, correcting for the chemical shift effect by means of water‐fat separation is essential for body QSM. By employing techniques to compensate for cardiac and respiratory motion artifacts, body QSM has been applied to study liver iron and fibrosis, heart chamber blood and placenta oxygenation, myocardial hemorrhage, atherosclerotic plaque, cartilage, bone, prostate, breast calcification, and kidney stone.