José Basílio Simões
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
José Basílio Simões has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Manuel B. A. Correia
Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra, Portugal
25 shared publications - João M. R. Cardoso
LIBPhys, Department of Physics, University of Coimbra, 3004-516 Coimbra, Portugal
10 shared publications - Custodio F. M. Loureiro
Centro de Instrumentação, Department of Physics, University of Coimbra, Coimbra, Portugal
5 shared publications - Helena Catarina Pereira
University of Coimbra
4 shared publications - Jorge Landeck
Centro de Instrumentação, Department of Physics, University of Coimbra, Coimbra, Portugal
4 shared publications - Jorge Sousa
Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
4 shared publications
Latest Publications
- 1 January 2013
- Published by INSTICC
- p. 221-227
Snoring Analysis on Full Night Recordings based in the Energy and Entropy in PSG Basal Studies
The SCITEPRESS Digital Library offers online access to all papers presented at INSTICC conferences, as well as a few conferences organized by others.
- 1 January 2013
- Published by INSTICC
- p. 221-227
Snoring Analysis on Full Night Recordings based in the Energy and Entropy in PSG Basal Studies
The SCITEPRESS Digital Library offers online access to all papers presented at INSTICC conferences, as well as a few conferences organized by others.
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
New instrumentation for cardiovascular risk assessment: The role of pulse wave velocity
Over the last years, great emphasis has been placed on the role of arterial stiffness in the development of cardiovascular diseases. This hemodynamic parameter, generally associated to age and blood pressure increase, can be assessed by the measurement of pulse wave velocity (PWV). Currently available devices that measure PWV are expensive and need to be operated by skilled medical staff, reducing the potential of ambulatory setting. This research project aims at developing and testing the sensoring and algorithmic basis of an alternative and non-invasive device for PWV assessment. The proposed device is based on a double-headed sensor probe and allows the assessment of PWV in one single location, providing important information on local arterial hemodynamics. Although studies to validate the clinical use of this system are still required, it has already demonstrated good performance on a dedicated test bench system, capable of reproducing a range of relevant cardiovascular system's properties.
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
New instrumentation for cardiovascular risk assessment: The role of pulse wave velocity
Over the last years, great emphasis has been placed on the role of arterial stiffness in the development of cardiovascular diseases. This hemodynamic parameter, generally associated to age and blood pressure increase, can be assessed by the measurement of pulse wave velocity (PWV). Currently available devices that measure PWV are expensive and need to be operated by skilled medical staff, reducing the potential of ambulatory setting. This research project aims at developing and testing the sensoring and algorithmic basis of an alternative and non-invasive device for PWV assessment. The proposed device is based on a double-headed sensor probe and allows the assessment of PWV in one single location, providing important information on local arterial hemodynamics. Although studies to validate the clinical use of this system are still required, it has already demonstrated good performance on a dedicated test bench system, capable of reproducing a range of relevant cardiovascular system's properties.
- 1 January 2011
- Published by INSTICC
- p. 444-447
DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment
- 1 January 2011
- Published by INSTICC
- p. 444-447
DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment
- 20 September 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (11) , 1449-1465
Characterization of a double probe for local pulse wave velocity assessment
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 ± 2.02 ms(-1)) and the PWV determined using the reference method (19.26 ± 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
- 20 September 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (11) , 1449-1465
Characterization of a double probe for local pulse wave velocity assessment
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 ± 2.02 ms(-1)) and the PWV determined using the reference method (19.26 ± 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
- 1 January 2009
- Published by Springer Nature
- p. 1460-1463
Programmable Test Bench for Hemodynamic Studies
- 1 January 2009
- Published by Springer Nature
- p. 1460-1463
Programmable Test Bench for Hemodynamic Studies
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1391-1395
Optimization of digital spectrometers using a pulse streaming generator
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1391-1395
Optimization of digital spectrometers using a pulse streaming generator
- 19 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 921-925
A high performance reconfigurable hardware platform for digital pulse processing
This paper presents a new reconfigurable hardware platform which uses both digital signal processors (DSP) and field programmable gate arrays (FPGA) to attain high resolution and real-time processing in nuclear spectrometry experiments. The module was designed in order to provide a high digital pulse processing (DPP) yield with the capacity of being reconfigurable according to the experimental conditions and the desired data output. This allows unprecedented real time processing capabilities implemented in the FPGA such as pulse pileup correction through adaptive filtering and effective signal-to-noise ratio (SNR) control and optimization. The module uses a Virtex-II Pro FPGA (Xilinx) and a DSP from the TMS320C64xx family (Texas Instruments) and is implemented on a PCI board to be used in a host workstation. Special emphasis is given to the scalability of the module along with the potential capacity of being used as a portable stand-alone instrument. This reconfigurable hardware platform allows us to simultaneously benefit from the advantages of the hardware based digital spectrometers, namely, their high throughput, and of the flexibility of the software based configurations. Besides, this same platform can be used as a general purpose high-speed data acquisition and processing unit.
- 19 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 921-925
A high performance reconfigurable hardware platform for digital pulse processing
This paper presents a new reconfigurable hardware platform which uses both digital signal processors (DSP) and field programmable gate arrays (FPGA) to attain high resolution and real-time processing in nuclear spectrometry experiments. The module was designed in order to provide a high digital pulse processing (DPP) yield with the capacity of being reconfigurable according to the experimental conditions and the desired data output. This allows unprecedented real time processing capabilities implemented in the FPGA such as pulse pileup correction through adaptive filtering and effective signal-to-noise ratio (SNR) control and optimization. The module uses a Virtex-II Pro FPGA (Xilinx) and a DSP from the TMS320C64xx family (Texas Instruments) and is implemented on a PCI board to be used in a host workstation. Special emphasis is given to the scalability of the module along with the potential capacity of being used as a portable stand-alone instrument. This reconfigurable hardware platform allows us to simultaneously benefit from the advantages of the hardware based digital spectrometers, namely, their high throughput, and of the flexibility of the software based configurations. Besides, this same platform can be used as a general purpose high-speed data acquisition and processing unit.
- 1 April 2004
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 522 (3) , 487-494
Dead-time analysis of digital spectrometers
- 1 April 2004
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 522 (3) , 487-494
Dead-time analysis of digital spectrometers
- 24 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 487-489
High speed multi input VME acquisition system
- 24 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 487-489
High speed multi input VME acquisition system
- 24 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 483-486
A new method for testing the effective number of bits of analog to digital converters
- 24 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 483-486
A new method for testing the effective number of bits of analog to digital converters