Oliver Boughton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oliver Boughton has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Justin Peter Cobb
MSK Lab, Imperial College London, London, UK
10 shared publications Ulrich Hansen
The Biomechanics Group, Department of Mechanical Engineering, Faculty of Engineering, London, SW7 2AZ, Imperial College London, London, UK
4 shared publications- Jonathan R. T. Jeffers
Department of Mechanical Engineering, Imperial College London, London, UK
3 shared publications - Ruben Doyle
Department of Mechanical Engineering, Imperial College London, London, UK
3 shared publications - Sarah Zhao
The Abdominal Wall Unit, Croydon University Hospital
3 shared publications Connor Green
Children’s Health Ireland at Temple Street
2 shared publications
Latest Publications
- Open Access
- 3 April 2026
- Published by Elsevier in Journal of the Pediatric Orthopaedic Society of North America
- Vol. 15
Cardiopulmonary Consequences of Scoliosis and the Clinical Implications of VO2max: A Systematic Review
- 3 April 2026
- Published by Elsevier in Journal of the Pediatric Orthopaedic Society of North America
- Vol. 15
Open AccessCardiopulmonary Consequences of Scoliosis and the Clinical Implications of VO2max: A Systematic Review
- 30 January 2026
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 41 (2)
Screw-Less U-Rod Pelvic Fixation in Early-Onset Scoliosis
- 30 January 2026
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 41 (2)
Screw-Less U-Rod Pelvic Fixation in Early-Onset Scoliosis
- Open Access
- 17 October 2025
- Published by Edorium Journals Pvt. Ltd. in International Journal of Case Reports and Images
- Vol. 16 (2) , 58-62
Fountain morphology of an osteochondral defect in a paediatric patient: A case report
Introduction: This case report describes a 13-year-old male patient, with unusual magnetic resonance imaging findings of subchondral cysts associated with an osteochondral defect of the right knee. Case Report: The patient presented with a six-week history of right knee pain, swelling and locking. Clinical examination revealed a loose body in the suprapatellar pouch, a small effusion, and a fixed flexion deformity. Imaging features revealed an unusual fountain-like morphology of the subchondral cysts, deep to the defect. The patient underwent surgical repair. Conclusion: This radiographical finding may suggest an interplay between biomechanical stress and subchondral bone remodeling, warranting further investigation into the pathogenesis of such morphology.
- 17 October 2025
- Published by Edorium Journals Pvt. Ltd. in International Journal of Case Reports and Images
- Vol. 16 (2) , 58-62
Open AccessFountain morphology of an osteochondral defect in a paediatric patient: A case report
Introduction: This case report describes a 13-year-old male patient, with unusual magnetic resonance imaging findings of subchondral cysts associated with an osteochondral defect of the right knee. Case Report: The patient presented with a six-week history of right knee pain, swelling and locking. Clinical examination revealed a loose body in the suprapatellar pouch, a small effusion, and a fixed flexion deformity. Imaging features revealed an unusual fountain-like morphology of the subchondral cysts, deep to the defect. The patient underwent surgical repair. Conclusion: This radiographical finding may suggest an interplay between biomechanical stress and subchondral bone remodeling, warranting further investigation into the pathogenesis of such morphology.
- 1 October 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (4)
Bilateral Proximal Femur Interval Fractures with a Slipped Femoral Capital Epiphysis After Fixation
Case: This case report, with 3 years of follow-up, describes a 9-year-old boy who suffered sequential Delbet type IV proximal femoral fractures. Three months postoperatively he had a unilateral slipped capital femoral epiphysis and had to undergo further surgery to address this. Conclusion: Proximal femur fractures are rare in childhood, and a slipped capital femoral epiphysis after fixation of a Delbet type 4 fracture has only been described once before in the literature. This case report highlights underlying risk factors of subsequent slipped capital femoral epiphysis after a Delbet type IV proximal femoral fracture and emphasizes the importance of careful follow-up.
- 1 October 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (4)
Bilateral Proximal Femur Interval Fractures with a Slipped Femoral Capital Epiphysis After Fixation
Case: This case report, with 3 years of follow-up, describes a 9-year-old boy who suffered sequential Delbet type IV proximal femoral fractures. Three months postoperatively he had a unilateral slipped capital femoral epiphysis and had to undergo further surgery to address this. Conclusion: Proximal femur fractures are rare in childhood, and a slipped capital femoral epiphysis after fixation of a Delbet type 4 fracture has only been described once before in the literature. This case report highlights underlying risk factors of subsequent slipped capital femoral epiphysis after a Delbet type IV proximal femoral fracture and emphasizes the importance of careful follow-up.
- Open Access
- 19 September 2024
- Published by BMJ in BMJ Open Quality
- Vol. 13 (3) , e002159
Value of an orthopaedic admission proforma
Background Admission notes are an important aspect of clinical practice and a vital means of communication among healthcare professionals. Incomplete or poor clinical documentation on admission can lead to delayed surgery. Patients and methods A retrospective analysis of 20 consecutive admission notes to our department was compared against the Royal College of Surgeons standards (GSP 2014). A new admission proforma was designed, and after the introductory period, two further retrospective cycles were performed. Results In total, 60 admission notes were analysed. Following the introduction of the proforma, there was an overall improvement in the documentation of the quality and quantity of notes studied. Conclusion Our study demonstrated that a well-structured admission protocol can improve the overall quality of admission notes.
- 19 September 2024
- Published by BMJ in BMJ Open Quality
- Vol. 13 (3) , e002159
Open AccessValue of an orthopaedic admission proforma
Background Admission notes are an important aspect of clinical practice and a vital means of communication among healthcare professionals. Incomplete or poor clinical documentation on admission can lead to delayed surgery. Patients and methods A retrospective analysis of 20 consecutive admission notes to our department was compared against the Royal College of Surgeons standards (GSP 2014). A new admission proforma was designed, and after the introductory period, two further retrospective cycles were performed. Results In total, 60 admission notes were analysed. Following the introduction of the proforma, there was an overall improvement in the documentation of the quality and quantity of notes studied. Conclusion Our study demonstrated that a well-structured admission protocol can improve the overall quality of admission notes.
- Open Access
- 7 June 2024
- Published by EDP Sciences in SICOT-J
- Vol. 10, 25
Do joint-preserving hip procedures compromise subsequent total hip arthroplasty? A meta-analysis of complications, functional outcome and survivorship
Background: Joint-preserving hip operations can help relieve pain and delay the need for long-term joint arthroplasty. Previous research has not identified procedures that can compromise outcomes following total hip arthroplasty (THA). This meta-analysis aims to evaluate the effect of joint-preserving hip operations on outcomes following subsequent THA. Methods: MEDLINE, EMBASE and Scopus databases were searched from the date of inception until February 2024. All studies comparing outcomes following THA in individuals with (PS) and without prior surgery (NPS) of the femur or pelvis were included. Data on operative time, blood loss, intra- and post-operative complications, functional outcomes, and implant survivorship were extracted. Results: 16 studies, comprising 2576 patients were included (PS = 939, NPS = 1637). The PS group was associated with significantly longer operative time [MD: 8.1, 95% CI: 4.6–11.6], significantly greater blood loss [MD: 167.8, 95% CI: 135.6–200.0], and a higher risk of intra-operative peri-prosthetic fracture [RR: 1.9, 95% CI: 1.2–3.0], specifically, with prior femoral osteotomy. There were no differences in terms of risks of dislocation [RR: 1.8, 95% CI: 1.0–3.2], implant loosening [RR: 1.0, 95% CI: 0.7–1.5], or revision surgery [RR: 1.3, 95% CI: 1.0–1.7] between the two groups. The PS group was associated with significantly poorer improvements in functional outcome [MD: −5.6, 95% CI: −7.6–(−3.5)], specifically, with prior acetabular osteotomy. Implant survivorship in the two groups was comparable after one year [HR: 1.9, 95% CI: 0.6–6.2] but significantly inferior in the PS group after five years [HR: 2.5, 95% CI: 1.4–4.7], specifically, with prior femoral osteotomy. Conclusion: Joint-preserving hip operations are associated with greater intra-operative challenges and complications. In subsequent joint arthroplasty, prior acetabular procedures affect functional outcomes while prior femoral procedures influence implant survivorship. Hip pain due to the morphological sequelae of pediatric hip pathology can be debilitating at a young age. Surgical decision-making at that time needs to consider the survivorship of a THA implanted at that young age against the consequences of hip preservation surgery on further THA.
- 7 June 2024
- Published by EDP Sciences in SICOT-J
- Vol. 10, 25
Open AccessDo joint-preserving hip procedures compromise subsequent total hip arthroplasty? A meta-analysis of complications, functional outcome and survivorship
Background: Joint-preserving hip operations can help relieve pain and delay the need for long-term joint arthroplasty. Previous research has not identified procedures that can compromise outcomes following total hip arthroplasty (THA). This meta-analysis aims to evaluate the effect of joint-preserving hip operations on outcomes following subsequent THA. Methods: MEDLINE, EMBASE and Scopus databases were searched from the date of inception until February 2024. All studies comparing outcomes following THA in individuals with (PS) and without prior surgery (NPS) of the femur or pelvis were included. Data on operative time, blood loss, intra- and post-operative complications, functional outcomes, and implant survivorship were extracted. Results: 16 studies, comprising 2576 patients were included (PS = 939, NPS = 1637). The PS group was associated with significantly longer operative time [MD: 8.1, 95% CI: 4.6–11.6], significantly greater blood loss [MD: 167.8, 95% CI: 135.6–200.0], and a higher risk of intra-operative peri-prosthetic fracture [RR: 1.9, 95% CI: 1.2–3.0], specifically, with prior femoral osteotomy. There were no differences in terms of risks of dislocation [RR: 1.8, 95% CI: 1.0–3.2], implant loosening [RR: 1.0, 95% CI: 0.7–1.5], or revision surgery [RR: 1.3, 95% CI: 1.0–1.7] between the two groups. The PS group was associated with significantly poorer improvements in functional outcome [MD: −5.6, 95% CI: −7.6–(−3.5)], specifically, with prior acetabular osteotomy. Implant survivorship in the two groups was comparable after one year [HR: 1.9, 95% CI: 0.6–6.2] but significantly inferior in the PS group after five years [HR: 2.5, 95% CI: 1.4–4.7], specifically, with prior femoral osteotomy. Conclusion: Joint-preserving hip operations are associated with greater intra-operative challenges and complications. In subsequent joint arthroplasty, prior acetabular procedures affect functional outcomes while prior femoral procedures influence implant survivorship. Hip pain due to the morphological sequelae of pediatric hip pathology can be debilitating at a young age. Surgical decision-making at that time needs to consider the survivorship of a THA implanted at that young age against the consequences of hip preservation surgery on further THA.
- Open Access
- 23 April 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (4) , 193-200
Dynamics of manual impaction instruments during total hip arthroplasty
Aims: Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.Methods: Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.Results: The force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face.Conclusion: The direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training.Cite this article: Bone Joint Res 2024;13(4):193–200.
- 23 April 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (4) , 193-200
Open AccessDynamics of manual impaction instruments during total hip arthroplasty
Aims: Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.Methods: Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.Results: The force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face.Conclusion: The direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training.Cite this article: Bone Joint Res 2024;13(4):193–200.
- Open Access
- 8 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-7
Enhancing acetabular reaming accuracy: optimal techniques and a novel reamer design
Successful press-fit implantation relies on an accurately reamed bone cavity. Inaccurate reaming can lead to a suboptimal press-fit risking fracture and cup deformation or excessive micromotion and loosening. Several factors may impact reaming accuracy including the reamer design, the surgeon’s technique and the bone quality. The aim of this study is to investigate the accuracy of reaming techniques and the accuracy of a novel reamer design. Eighty composite bone models, half high density and half low density, were reamed with either a conventional or an additively manufactured reamer with a novel design employing either a straight or ‘whirlwind’ reaming technique. Reamed cavities were scanned using a 3D laser scanner and the median difference between achieved and expected diameters compared. The novel reamer design was more accurate than the unused conventional reamer, using both whirlwind (0.1 mm (IQR 0–0.2) vs. 0.3 mm (IQR 0.3–0.4); p < 0.001) and straight techniques (0.3 mm (IQR 0.1–1.0) vs. 1.2 mm (IQR 1–1.6); p = 0.001). Whirlwind reaming was more accurate than straight reaming using both conventional (0.3 mm (IQR 0.3–0.4) vs. 1.2 mm (IQR 1–1.6); p < 0.0001) and single use reamers (0.1 mm (IQR 0–0.2) vs. 0.3 mm (IQR 0.1–1.0); p = 0.007). Reaming errors were higher in low-density bone compared to high-density bone, for both reamer types and reaming techniques tested (0.6 mm (IQR 0.3–1.5) vs. 0.3 mm (IQR 0.1–0.8); p = 0.005). We present a novel reamer design that demonstrates superior accuracy to conventional reamers in achieving the desired reaming diameter. Improved reaming accuracy was also demonstrated using both devices and in both bone models, using a ‘whirlwind’ technique. We recommend the use of this novel reamer design employing a ‘whirlwind’ technique to optimize reaming accuracy. Particular attention should be paid toward patients with lower bone quality which may be more susceptible to higher inaccuracies.
- 8 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-7
Open AccessEnhancing acetabular reaming accuracy: optimal techniques and a novel reamer design
Successful press-fit implantation relies on an accurately reamed bone cavity. Inaccurate reaming can lead to a suboptimal press-fit risking fracture and cup deformation or excessive micromotion and loosening. Several factors may impact reaming accuracy including the reamer design, the surgeon’s technique and the bone quality. The aim of this study is to investigate the accuracy of reaming techniques and the accuracy of a novel reamer design. Eighty composite bone models, half high density and half low density, were reamed with either a conventional or an additively manufactured reamer with a novel design employing either a straight or ‘whirlwind’ reaming technique. Reamed cavities were scanned using a 3D laser scanner and the median difference between achieved and expected diameters compared. The novel reamer design was more accurate than the unused conventional reamer, using both whirlwind (0.1 mm (IQR 0–0.2) vs. 0.3 mm (IQR 0.3–0.4); p < 0.001) and straight techniques (0.3 mm (IQR 0.1–1.0) vs. 1.2 mm (IQR 1–1.6); p = 0.001). Whirlwind reaming was more accurate than straight reaming using both conventional (0.3 mm (IQR 0.3–0.4) vs. 1.2 mm (IQR 1–1.6); p < 0.0001) and single use reamers (0.1 mm (IQR 0–0.2) vs. 0.3 mm (IQR 0.1–1.0); p = 0.007). Reaming errors were higher in low-density bone compared to high-density bone, for both reamer types and reaming techniques tested (0.6 mm (IQR 0.3–1.5) vs. 0.3 mm (IQR 0.1–0.8); p = 0.005). We present a novel reamer design that demonstrates superior accuracy to conventional reamers in achieving the desired reaming diameter. Improved reaming accuracy was also demonstrated using both devices and in both bone models, using a ‘whirlwind’ technique. We recommend the use of this novel reamer design employing a ‘whirlwind’ technique to optimize reaming accuracy. Particular attention should be paid toward patients with lower bone quality which may be more susceptible to higher inaccuracies.
- Open Access
A Cross-Sectional Study of Bone Nanomechanics in Hip Fracture and Aging
Bone mechanics is well understood at every length scale except the nano-level. We aimed to investigate the relationship between bone nanoscale and tissue-level mechanics experimentally. We tested two hypotheses: (1) nanoscale strains were lower in hip fracture patients versus controls, and (2) nanoscale mineral and fibril strains were inversely correlated with aging and fracture. A cross-sectional sample of trabecular bone sections was prepared from the proximal femora of two human donor groups (aged 44–94 years): an aging non-fracture control group (n = 17) and a hip-fracture group (n = 20). Tissue, fibril, and mineral strain were measured simultaneously using synchrotron X-ray diffraction during tensile load to failure, then compared between groups using unpaired t-tests and correlated with age using Pearson’s correlation. Controls exhibited significantly greater peak tissue, mineral, and fibril strains than the hip fracture (all p < 0.05). Age was associated with a decrease in peak tissue (p = 0.099) and mineral (p = 0.004) strain, but not fibril strain (p = 0.260). Overall, hip fracture and aging were associated with changes in the nanoscale strain that are reflected at the tissue level. Data must be interpreted within the limitations of the observational cross-sectional study design, so we propose two new hypotheses on the importance of nanomechanics. (1) Hip fracture risk is increased by low tissue strain, which can be caused by low collagen or mineral strain. (2) Age-related loss of tissue strain is dependent on the loss of mineral but not fibril strain. Novel insights into bone nano- and tissue-level mechanics could provide a platform for the development of bone health diagnostics and interventions based on failure mechanisms from the nanoscale up.
Open AccessA Cross-Sectional Study of Bone Nanomechanics in Hip Fracture and Aging
Bone mechanics is well understood at every length scale except the nano-level. We aimed to investigate the relationship between bone nanoscale and tissue-level mechanics experimentally. We tested two hypotheses: (1) nanoscale strains were lower in hip fracture patients versus controls, and (2) nanoscale mineral and fibril strains were inversely correlated with aging and fracture. A cross-sectional sample of trabecular bone sections was prepared from the proximal femora of two human donor groups (aged 44–94 years): an aging non-fracture control group (n = 17) and a hip-fracture group (n = 20). Tissue, fibril, and mineral strain were measured simultaneously using synchrotron X-ray diffraction during tensile load to failure, then compared between groups using unpaired t-tests and correlated with age using Pearson’s correlation. Controls exhibited significantly greater peak tissue, mineral, and fibril strains than the hip fracture (all p < 0.05). Age was associated with a decrease in peak tissue (p = 0.099) and mineral (p = 0.004) strain, but not fibril strain (p = 0.260). Overall, hip fracture and aging were associated with changes in the nanoscale strain that are reflected at the tissue level. Data must be interpreted within the limitations of the observational cross-sectional study design, so we propose two new hypotheses on the importance of nanomechanics. (1) Hip fracture risk is increased by low tissue strain, which can be caused by low collagen or mineral strain. (2) Age-related loss of tissue strain is dependent on the loss of mineral but not fibril strain. Novel insights into bone nano- and tissue-level mechanics could provide a platform for the development of bone health diagnostics and interventions based on failure mechanisms from the nanoscale up.
- Open Access
- 23 November 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105573
Association between nanoscale strains and tissue level nanoindentation properties in age-related hip-fractures
- 23 November 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105573
Open AccessAssociation between nanoscale strains and tissue level nanoindentation properties in age-related hip-fractures