Vasco Peixoto de Freitas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vasco Peixoto de Freitas has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- João M. P. Q. Delgado
CONSTRUCT, Department of Civil Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
73 shared publications - Ana Sofia Guimarães
University of Porto
37 shared publications - Eva Barreira
Universidade do Porto
32 shared publications - Nuno Manuel Monteiro Ramos
University of Porto
29 shared publications - Ricardo Manuel Santos Ferreira Almeida
Department of Civil Engineering, Polytechnic Institute of Viseu, 3504-510 Viseu, Portugal
11 shared publications - Inês Flores-Colen
CERIS, DECivil, Instituto Superior Técnico, University of Lisbon, 1049-001 Lisbon, Portugal
8 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 26
Manifestações patológicas relacionadas à umidade em edificações do norte de Portugal: relato de casos entre 1990 e 2023
Resumo Este trabalho centrou na realização de levantamento de indicadores de distintas manifestações patológicas associadas à umidade, ocorridas em edificações da região Norte de Portugal entre os anos de 1990 e 2023, cuja base dos dados foi obtida por laudos técnicos periciais (judiciais e extrajudiciais). A metodologia envolveu a utilização de universo amostral de 125 laudos, sendo que as paredes (duplas e simples) e as lajes constituíram as vertentes analisadas. Foram produzidos gráficos estatísticos e correlações que possibilitaram estabelecer uma contribuição relevante à temática umidade em edificações por meio das seguintes ponderações: edificações residenciais (56%) e públicas (18%) apresentaram a maioria dos problemas; paredes duplas apresentaram mais anomalias (51%) quando comparadas às paredes simples (16%) e as lajes (33%); o sistema que mais apresentou manifestações patológicas foi o constituído de bloco cerâmico nas paredes duplas (81%), nas paredes simples foi o com rocha (60%) e nas lajes (tetos) foi o com concreto pré-moldado (61%); as vertentes paredes duplas, paredes simples e lajes foram em sua maioria acometidas pelas manchas de umidade (55%; 45%; 60%), degradação do revestimento (26%; 35%; 24%) e eflorescências (9%; 10%; 7%), respectivamente; a umidade se torna a principal porta de entrada para o surgimento de outros danos que acarretam prejuízos estéticos, de saúde e financeiro.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 26
Open AccessManifestações patológicas relacionadas à umidade em edificações do norte de Portugal: relato de casos entre 1990 e 2023
Resumo Este trabalho centrou na realização de levantamento de indicadores de distintas manifestações patológicas associadas à umidade, ocorridas em edificações da região Norte de Portugal entre os anos de 1990 e 2023, cuja base dos dados foi obtida por laudos técnicos periciais (judiciais e extrajudiciais). A metodologia envolveu a utilização de universo amostral de 125 laudos, sendo que as paredes (duplas e simples) e as lajes constituíram as vertentes analisadas. Foram produzidos gráficos estatísticos e correlações que possibilitaram estabelecer uma contribuição relevante à temática umidade em edificações por meio das seguintes ponderações: edificações residenciais (56%) e públicas (18%) apresentaram a maioria dos problemas; paredes duplas apresentaram mais anomalias (51%) quando comparadas às paredes simples (16%) e as lajes (33%); o sistema que mais apresentou manifestações patológicas foi o constituído de bloco cerâmico nas paredes duplas (81%), nas paredes simples foi o com rocha (60%) e nas lajes (tetos) foi o com concreto pré-moldado (61%); as vertentes paredes duplas, paredes simples e lajes foram em sua maioria acometidas pelas manchas de umidade (55%; 45%; 60%), degradação do revestimento (26%; 35%; 24%) e eflorescências (9%; 10%; 7%), respectivamente; a umidade se torna a principal porta de entrada para o surgimento de outros danos que acarretam prejuízos estéticos, de saúde e financeiro.
- Open Access
- 27 June 2023
- Published by ScienceOpen
Moisture content influence on heat losses in ventilated façade
Heat losses due to moisture could become relevant in certain climates. A ventilated façade in concrete, covered with granite slabs, has been tested using Wufi-Pro 6.7 software, previously validated with experimental data. This research assessed the influence of different insulation thicknesses in this façade and their interrelationship with moisture content fluctuation, U-value performance variability, and heat losses. The study firmly established a correlation between them.
- 27 June 2023
- Published by ScienceOpen
Open AccessMoisture content influence on heat losses in ventilated façade
Heat losses due to moisture could become relevant in certain climates. A ventilated façade in concrete, covered with granite slabs, has been tested using Wufi-Pro 6.7 software, previously validated with experimental data. This research assessed the influence of different insulation thicknesses in this façade and their interrelationship with moisture content fluctuation, U-value performance variability, and heat losses. The study firmly established a correlation between them.
- Open Access
- 13 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (4) , 2382
Retrofitting Historic Buildings for Future Climatic Conditions and Consequences in Terms of Artifacts Conservation Using Hygrothermal Building Simulation
Climate change will greatly influence the world at several levels and will have consequences on the interior climate of historic buildings and artifacts conservation. Buildings are responsible for a large slice of the overall emissions, which is due both to the greenhouse gases that are released during their construction as well as the activities that are performed therewithin. One way of counteracting this trend is to design more efficient retrofit buildings and predict their behavior using simulation software, which can thoroughly assess the performance of new buildings or the impact of each retrofit measure for existing buildings. In this study, a calibrated computational model of high thermal inertia building was used to assess the performance of passive retrofits in mitigating the effects of climate change concerning artifact decay mechanisms. In addition, a methodology that aims to reduce the amount of time spent to perform these studies is also presented, in which time savings reach up to 63%.
- 13 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (4) , 2382
Open AccessRetrofitting Historic Buildings for Future Climatic Conditions and Consequences in Terms of Artifacts Conservation Using Hygrothermal Building Simulation
Climate change will greatly influence the world at several levels and will have consequences on the interior climate of historic buildings and artifacts conservation. Buildings are responsible for a large slice of the overall emissions, which is due both to the greenhouse gases that are released during their construction as well as the activities that are performed therewithin. One way of counteracting this trend is to design more efficient retrofit buildings and predict their behavior using simulation software, which can thoroughly assess the performance of new buildings or the impact of each retrofit measure for existing buildings. In this study, a calibrated computational model of high thermal inertia building was used to assess the performance of passive retrofits in mitigating the effects of climate change concerning artifact decay mechanisms. In addition, a methodology that aims to reduce the amount of time spent to perform these studies is also presented, in which time savings reach up to 63%.
- 3 January 2023
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 18 (3) , 477-491
Influence of Moisture on the Energy Performance of Retrofitted Walls - Experimental Assessment and Validation of an Hygrothermal Model
The rehabilitation of existing buildings façades should be based on the improvement in comfort and the decrease of energy consumption. For this purpose, it is necessary to select a retrofitted solution capable of minimizing the heat losses across the building envelope. However, it is not only the retrofitted solution of the wall that influences the amount of heat transported across it, but also the moisture content in the wall under in-service conditions. An experimental prototype was developed to experimentally assess the impact of a wetting period on the energy performance of wall test specimens. The experiment simulated the exposure of the specimens to a rainy period with a continuous record of the heat fluxes across both surfaces of the specimens. Additionally, the validation of the WUFI hygrothermal simulation model, based on the experimental measurements performed, was carried out. Driving rain resulted in an increase of heat losses of around 10%.
- 3 January 2023
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 18 (3) , 477-491
Influence of Moisture on the Energy Performance of Retrofitted Walls - Experimental Assessment and Validation of an Hygrothermal Model
The rehabilitation of existing buildings façades should be based on the improvement in comfort and the decrease of energy consumption. For this purpose, it is necessary to select a retrofitted solution capable of minimizing the heat losses across the building envelope. However, it is not only the retrofitted solution of the wall that influences the amount of heat transported across it, but also the moisture content in the wall under in-service conditions. An experimental prototype was developed to experimentally assess the impact of a wetting period on the energy performance of wall test specimens. The experiment simulated the exposure of the specimens to a rainy period with a continuous record of the heat fluxes across both surfaces of the specimens. Additionally, the validation of the WUFI hygrothermal simulation model, based on the experimental measurements performed, was carried out. Driving rain resulted in an increase of heat losses of around 10%.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2918 (1)
Retrofitting traditional walls: A comparative study on thermal renders and more common insulation materials
To reach the European climate-neutrality by 2050, the strategic importance of a large energy-efficient renovation of the existing building stock is clear. Among
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2918 (1)
Open AccessRetrofitting traditional walls: A comparative study on thermal renders and more common insulation materials
To reach the European climate-neutrality by 2050, the strategic importance of a large energy-efficient renovation of the existing building stock is clear. Among
- Open Access
Retrofitting Historic Walls: Feasibility of Thermal Insulation and Suitability of Thermal Mortars
The European Union is pursuing an ambitious policy on climate action, urgently calling for an acceleration in the transition toward net-zero emissions by 2050. In this context, retrofitting historic constructions can play a key role in reducing European energy consumption and consequent emissions. What is more, beyond the opportunity for tackling climate change, thermal retrofits can improve indoor comfort while lowering operational costs, factors that are fundamental to ensure the continued use of historic constructions over time, and with that, improving their preservation and durability. The suitability of thermal insulation for this scope is still a debated topic. Thus, this study aims at contributing to the discussion by providing an overview on the feasibility of adopting thermal insulation for retrofitting external walls of historic buildings while preserving their significance and unique identities. Finally, the advantages of adopting thermal mortars rather than more traditional insulation solutions are outlined, and their potential efficacy is discussed.
Open AccessRetrofitting Historic Walls: Feasibility of Thermal Insulation and Suitability of Thermal Mortars
The European Union is pursuing an ambitious policy on climate action, urgently calling for an acceleration in the transition toward net-zero emissions by 2050. In this context, retrofitting historic constructions can play a key role in reducing European energy consumption and consequent emissions. What is more, beyond the opportunity for tackling climate change, thermal retrofits can improve indoor comfort while lowering operational costs, factors that are fundamental to ensure the continued use of historic constructions over time, and with that, improving their preservation and durability. The suitability of thermal insulation for this scope is still a debated topic. Thus, this study aims at contributing to the discussion by providing an overview on the feasibility of adopting thermal insulation for retrofitting external walls of historic buildings while preserving their significance and unique identities. Finally, the advantages of adopting thermal mortars rather than more traditional insulation solutions are outlined, and their potential efficacy is discussed.
- Open Access
Impact of Stationary and Dynamic Conditions on the U-Value Measurements of Heavy-Multi Leaf Walls by Quantitative IRT
Infrared thermography (IRT) has become a commonly applied non-destructive testing method for assessing building envelopes. Like any diagnosis tool, IRT requires an appropriate experience and principle understanding, mainly when the method is used for quantitative analyses. The challenges of the IRT often deal with the dynamic properties of building partitions. Climatic conditions have a certain variability, and the accumulated energy storage in the building components can affect their temperature as well as the calculated thermal performance. This paper aims to analyze how stationary and dynamic regimes of a quantitative IRT test could impact the measured thermal transmittance of heavy multi-leaf walls. Investigation in two European countries with different climatic conditions are reported. In this way, it is discussed which boundary conditions should be guaranteed to provide reliable information about a building envelope using quantitative IRT. In order to check the quality of the measurements, the heat flux meter (HFM) method was also implemented, following the ISO 9869. The research revealed that it could be possible to use short-lasting tests in the climatic conditions of Southern Europe, while long-term tests should be implemented in Northern European countries where climatic conditions are less regular.
Open AccessImpact of Stationary and Dynamic Conditions on the U-Value Measurements of Heavy-Multi Leaf Walls by Quantitative IRT
Infrared thermography (IRT) has become a commonly applied non-destructive testing method for assessing building envelopes. Like any diagnosis tool, IRT requires an appropriate experience and principle understanding, mainly when the method is used for quantitative analyses. The challenges of the IRT often deal with the dynamic properties of building partitions. Climatic conditions have a certain variability, and the accumulated energy storage in the building components can affect their temperature as well as the calculated thermal performance. This paper aims to analyze how stationary and dynamic regimes of a quantitative IRT test could impact the measured thermal transmittance of heavy multi-leaf walls. Investigation in two European countries with different climatic conditions are reported. In this way, it is discussed which boundary conditions should be guaranteed to provide reliable information about a building envelope using quantitative IRT. In order to check the quality of the measurements, the heat flux meter (HFM) method was also implemented, following the ISO 9869. The research revealed that it could be possible to use short-lasting tests in the climatic conditions of Southern Europe, while long-term tests should be implemented in Northern European countries where climatic conditions are less regular.
- Open Access
- 23 September 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (19) , 7855
Is the Time-Domain Reflectometry (TDR) Technique Suitable for Moisture Content Measurement in Low-Porosity Building Materials?
Measuring moisture content in building materials is essential both for professional practice and for research. However, this is a very complex task, especially when long-term minor destructive measurements are desired. The time-domain reflectometry (TDR) technique is commonly used for soil moisture measurements, but its application in construction materials is considered a relatively new method, particularly for low-porosity building materials. The major obstacles to its current use in construction materials are (1) the difficulty of ensuring good contact between the TDR probe and the material, and (2) the lack of appropriate conversion functions between the measured relative permittivity and the moisture content of building materials. This paper intends to contribute to overcoming these difficulties by explaining in detail all the required steps to monitor moisture content in real-scale limestone walls. For that, a device is presented to guarantee the correct installation of the TDR probes on the walls, and a calibration procedure through the gravimetric method is proposed to avoid the use of an unsuitable calibration function developed for soil moisture measurements. In addition, the importance of the individual probe calibration is discussed, as well as TDR advantages and disadvantages for construction materials. The results obtained so far reveal that the TDR technique is suitable to detect moisture content variations in limestone, which is a low-porosity building material.
- 23 September 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (19) , 7855
Open AccessIs the Time-Domain Reflectometry (TDR) Technique Suitable for Moisture Content Measurement in Low-Porosity Building Materials?
Measuring moisture content in building materials is essential both for professional practice and for research. However, this is a very complex task, especially when long-term minor destructive measurements are desired. The time-domain reflectometry (TDR) technique is commonly used for soil moisture measurements, but its application in construction materials is considered a relatively new method, particularly for low-porosity building materials. The major obstacles to its current use in construction materials are (1) the difficulty of ensuring good contact between the TDR probe and the material, and (2) the lack of appropriate conversion functions between the measured relative permittivity and the moisture content of building materials. This paper intends to contribute to overcoming these difficulties by explaining in detail all the required steps to monitor moisture content in real-scale limestone walls. For that, a device is presented to guarantee the correct installation of the TDR probes on the walls, and a calibration procedure through the gravimetric method is proposed to avoid the use of an unsuitable calibration function developed for soil moisture measurements. In addition, the importance of the individual probe calibration is discussed, as well as TDR advantages and disadvantages for construction materials. The results obtained so far reveal that the TDR technique is suitable to detect moisture content variations in limestone, which is a low-porosity building material.
- 20 August 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 252, 119079
Reliability of in-situ diagnosis in external wall renders
- 20 August 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 252, 119079
Reliability of in-situ diagnosis in external wall renders