Haksung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haksung Lee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Akihito Ozaki
9 shared publicationsMyonghyang Lee
Department of Science and Engineering, Ritsumeikan University, Kusatsu, Japan
3 shared publications- Younhee Choi
Faculty of Human-Environment Studies, Kyushu University, Fukuoka, Japan
3 shared publications - Akihito Ozaki
Department of Architecture and Urban Design, Kyushu University, Fukuoka 812-0053, Japan
1 shared publication - Bayaraa Batsuuri
Department of Architecture, Chungbuk National University, 1 Chungdae-ro, Cheongju 28644, Republic of Korea
1 shared publication - Huihua Liu1 shared publication
Latest Publications
- Open Access
Evaluation of Steady-State Volumetric Heating Load Methods Considering Building Envelope Type and Window-to-Wall Ratio
Recent studies have shown that building-envelope characteristics, including thermal mass and window-related solar gains, can significantly influence heating load behavior. However, their implications for the applicability and accuracy of simplified volumetric heating load methods remain insufficiently understood. Therefore, this study evaluates the applicability and accuracy of steady-state volumetric heating load methods under varying envelope conditions. Representative residential building models with different envelope types and window-to-wall ratios (WWRs) were analyzed. Heating loads were calculated using a normative volumetric approach based on tabulated specific heat-loss coefficients (Method 1) and a recalculated approach incorporating envelope characteristics and solar gains (Method 2). A comparison at hourly, peak-load, seasonal, and load-duration-curve (LDC) levels revealed that the performance of steady-state volumetric methods is strongly dependent on both envelope characteristics and the level of heating load assessment. Method 1 consistently overestimated seasonal heating demand by 41–218%, whereas Method 2 substantially reduced the error. However, Method 2 still underestimated annual heating demand in highly insulated buildings (up to 39%) and peak heating load (up to 63%). These findings indicate that the applicability of volumetric methods depends on both envelope characteristics and the level of heating load assessment. The results highlight the importance of accounting for envelope-dependent thermal-mass effects when applying volumetric methods to hourly, peak-load, seasonal, and LDC-based analyses.
Open AccessEvaluation of Steady-State Volumetric Heating Load Methods Considering Building Envelope Type and Window-to-Wall Ratio
Recent studies have shown that building-envelope characteristics, including thermal mass and window-related solar gains, can significantly influence heating load behavior. However, their implications for the applicability and accuracy of simplified volumetric heating load methods remain insufficiently understood. Therefore, this study evaluates the applicability and accuracy of steady-state volumetric heating load methods under varying envelope conditions. Representative residential building models with different envelope types and window-to-wall ratios (WWRs) were analyzed. Heating loads were calculated using a normative volumetric approach based on tabulated specific heat-loss coefficients (Method 1) and a recalculated approach incorporating envelope characteristics and solar gains (Method 2). A comparison at hourly, peak-load, seasonal, and load-duration-curve (LDC) levels revealed that the performance of steady-state volumetric methods is strongly dependent on both envelope characteristics and the level of heating load assessment. Method 1 consistently overestimated seasonal heating demand by 41–218%, whereas Method 2 substantially reduced the error. However, Method 2 still underestimated annual heating demand in highly insulated buildings (up to 39%) and peak heating load (up to 63%). These findings indicate that the applicability of volumetric methods depends on both envelope characteristics and the level of heating load assessment. The results highlight the importance of accounting for envelope-dependent thermal-mass effects when applying volumetric methods to hourly, peak-load, seasonal, and LDC-based analyses.
- 7 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Impact of high vapor permeability resistance insulation in loess brick wall systems on indoor humidity conditions
- 7 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Impact of high vapor permeability resistance insulation in loess brick wall systems on indoor humidity conditions
- 2 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
An integrated passive dehumidification system with energy recovery ventilation: A comprehensive simulation study
- 2 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
An integrated passive dehumidification system with energy recovery ventilation: A comprehensive simulation study
- Open Access
Impact of Window Frames on Annual Energy Consumption of Residential Buildings and Its Contribution to CO2 Emission Reductions at the City Scale
Windows are among building components that have the strongest effect on thermal load. They play a significant role in heat loss in buildings because they usually have a largely higher thermal conductance than other components of the building envelope. Although many studies have highlighted the relevance of heat transfer through frames and aimed to improve their thermal performance, poorly insulated aluminum frames (thermal conductivity of aluminum is 160 W/m·K, while that of polyvinyl chloride [PVC] is 0.17 W/m·K) are still in use in Japan. Therefore, the U-values of different window frames were calculated, and annual thermal loads were calculated according to the window configurations, including the frame, glazing, and cavity. We focused on standard residential buildings in Japan with a total floor area of 120.6 m2 (two-story building), and the number of newly built houses and the application rate of window configurations in 2019 were surveyed to estimate the CO2 emissions by regions. CO2 emissions were reduced by approximately 3.98–6.58% with the application of PVC frames. Furthermore, CO2 emissions were converted into the amount of CO2 gas absorbed by cedar trees, which cover nearly 18% of the total land area of Japan. In conclusion, analogous to the amount of CO2 gas absorbed by cedar trees, the absorption effect was equivalent to 327,743–564,416 cedar trees. Changing the window frame material can facilitate a significant energy-saving effect as a considerable amount of energy is saved, especially at a city scale.
Open AccessImpact of Window Frames on Annual Energy Consumption of Residential Buildings and Its Contribution to CO2 Emission Reductions at the City Scale
Windows are among building components that have the strongest effect on thermal load. They play a significant role in heat loss in buildings because they usually have a largely higher thermal conductance than other components of the building envelope. Although many studies have highlighted the relevance of heat transfer through frames and aimed to improve their thermal performance, poorly insulated aluminum frames (thermal conductivity of aluminum is 160 W/m·K, while that of polyvinyl chloride [PVC] is 0.17 W/m·K) are still in use in Japan. Therefore, the U-values of different window frames were calculated, and annual thermal loads were calculated according to the window configurations, including the frame, glazing, and cavity. We focused on standard residential buildings in Japan with a total floor area of 120.6 m2 (two-story building), and the number of newly built houses and the application rate of window configurations in 2019 were surveyed to estimate the CO2 emissions by regions. CO2 emissions were reduced by approximately 3.98–6.58% with the application of PVC frames. Furthermore, CO2 emissions were converted into the amount of CO2 gas absorbed by cedar trees, which cover nearly 18% of the total land area of Japan. In conclusion, analogous to the amount of CO2 gas absorbed by cedar trees, the absorption effect was equivalent to 327,743–564,416 cedar trees. Changing the window frame material can facilitate a significant energy-saving effect as a considerable amount of energy is saved, especially at a city scale.
- 1 November 2020
- Published by Elsevier in Building and Environment
- Vol. 185
Housing design methodology for passive hygrothermal control and effect verification via field measurements
- 1 November 2020
- Published by Elsevier in Building and Environment
- Vol. 185
Housing design methodology for passive hygrothermal control and effect verification via field measurements
- 11 November 2019
- Published by Wiley in Indoor Air
- Vol. 30 (2) , 346-360
Humidity control effect of vapor‐permeable walls employing hygroscopic insulation material
Airtight construction and high‐performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial condensation and subsequent intrusion of moisture into the walls. Hygroscopic building materials such as cellulose fiber insulation (CFI), characterized by high water capacity, are a potential countermeasure against such condensation. In this study, the humidity control performance of external walls containing CFI was evaluated using data measured inside a demonstration house and calculated by numerical simulations based on thermodynamic chemical potential theory. The changes in moisture adsorption and desorption were then evaluated for different wall constructions and different climate conditions using a parameter sensitivity analysis. Finally, the effective application of CFI to prevent interstitial condensation was confirmed by comparing different wall compositions.
- 11 November 2019
- Published by Wiley in Indoor Air
- Vol. 30 (2) , 346-360
Humidity control effect of vapor‐permeable walls employing hygroscopic insulation material
Airtight construction and high‐performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial condensation and subsequent intrusion of moisture into the walls. Hygroscopic building materials such as cellulose fiber insulation (CFI), characterized by high water capacity, are a potential countermeasure against such condensation. In this study, the humidity control performance of external walls containing CFI was evaluated using data measured inside a demonstration house and calculated by numerical simulations based on thermodynamic chemical potential theory. The changes in moisture adsorption and desorption were then evaluated for different wall constructions and different climate conditions using a parameter sensitivity analysis. Finally, the effective application of CFI to prevent interstitial condensation was confirmed by comparing different wall compositions.
- 1 July 2019
- Published by Elsevier in Energy and Buildings
- Vol. 195, 139-148
A fundamental study of intelligent building envelope systems capable of passive dehumidification and solar heat collection utilizing renewable energy
- 1 July 2019
- Published by Elsevier in Energy and Buildings
- Vol. 195, 139-148
A fundamental study of intelligent building envelope systems capable of passive dehumidification and solar heat collection utilizing renewable energy
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 317-329
Sensitivity analysis for optimization of renewable-energy-based air-circulation-type temperature-control system
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 317-329
Sensitivity analysis for optimization of renewable-energy-based air-circulation-type temperature-control system