Igor E. Vnukov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Igor E. Vnukov has a total of 418 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Petrovich Potylitsyn
Tomsk Polytechnic University, Tomsk, Russia
26 shared publications B. N. Kalinin
Tomsk Polytechnical University
15 shared publicationsG. A. Naumenko
Tomsk Polytechnical University
11 shared publicationsR. A. Shatokhin
Belgorod National Research University, Belgorod, Russia
10 shared publicationsY. Takabayashi
SAGA Light Source, Tosu, Saga 8410005, Japan
10 shared publicationsB.N. Kalinin
8 shared publications
Latest Publications
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , C06005
Use of parametric X-ray radiation of electrons in crystals to determine the parameters of imaging-plates
Good agreement between experimental data and the results of calculations of the yield and angular distributions of parametric X-ray radiation of electrons in crystals within the framework of kinematic theory enables us to use the measurement results to determine the photon energy dependence of the sensitivity of X-ray plates. The results of measurements of the angular distributions of parametric X-ray radiation of electrons with an energy of 255 MeV in a Si crystal using imaging plates of several types were compared with the results of calculations that take into account all currently known experimental factors that influence the measurement results. The spectral dependence of the sensitivity of the studied X-ray plates was determined for photon energies of two orders of reflection and for the (111), (1̅1̅1), and (110) reflection planes.
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , C06005
Use of parametric X-ray radiation of electrons in crystals to determine the parameters of imaging-plates
Good agreement between experimental data and the results of calculations of the yield and angular distributions of parametric X-ray radiation of electrons in crystals within the framework of kinematic theory enables us to use the measurement results to determine the photon energy dependence of the sensitivity of X-ray plates. The results of measurements of the angular distributions of parametric X-ray radiation of electrons with an energy of 255 MeV in a Si crystal using imaging plates of several types were compared with the results of calculations that take into account all currently known experimental factors that influence the measurement results. The spectral dependence of the sensitivity of the studied X-ray plates was determined for photon energies of two orders of reflection and for the (111), (1̅1̅1), and (110) reflection planes.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , C05043
Influence of the reflectivity of a crystal on the angular distribution of diffracted transition radiation of relativistic electrons
The influence of the angular profile of crystal reflectivity on the assessment of the divergence of a beam of relativistic electrons is studied through measurements of the angular distribution of diffracted transition radiation. The results show that, when the angular distribution of reflectivity is taken into account, the obtained divergence values are close to the true values. Failure to take this effect into account leads to systematic errors in determining the horizontal divergence. The magnitude of the error depends on the beam divergence and is inversely proportional to the square of the energy of the reflected photons.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , C05043
Influence of the reflectivity of a crystal on the angular distribution of diffracted transition radiation of relativistic electrons
The influence of the angular profile of crystal reflectivity on the assessment of the divergence of a beam of relativistic electrons is studied through measurements of the angular distribution of diffracted transition radiation. The results show that, when the angular distribution of reflectivity is taken into account, the obtained divergence values are close to the true values. Failure to take this effect into account leads to systematic errors in determining the horizontal divergence. The magnitude of the error depends on the beam divergence and is inversely proportional to the square of the energy of the reflected photons.
- 1 February 2023
- Published by The Russian Academy of Sciences in Poverhnostʹ. Rentgenovskie, sinhrotronnye i nejtronnye issledovaniâ
- No. 2,p. 77-87
The Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams
The Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams Использование кристаллов с асимметричной геометрией отражения для измерения параметров электронных пучков
- 1 February 2023
- Published by The Russian Academy of Sciences in Poverhnostʹ. Rentgenovskie, sinhrotronnye i nejtronnye issledovaniâ
- No. 2,p. 77-87
The Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams
The Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams Использование кристаллов с асимметричной геометрией отражения для измерения параметров электронных пучков
- 1 February 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (1) , 240-250
On the Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams
The prospects of using crystals with asymmetric reflection geometry to determine the transverse size of relativistic electron beams based on the results of measuring the angular distributions of their radiation in a thin crystal for two distances between it and a coordinate detector are discussed. Experimental testing of this technique is carried out using an imaging plate as a two-dimensional position-sensitive detector. Measurements are made for an electron energy of 255 MeV and the reflection (220) in a silicon crystal with a thickness of 20 microns and a pixel size of 35 µm2. The distances between the crystal and the detector are 0.5 and 1 m. The obtained values of the horizontal and vertical beam sizes \({{\sigma }_{x}} = 0.32 \pm 0.02\,\,~{\text{mm}}\) and \({{\sigma }_{y}} = 1.35 \pm 0.02~\,\,{\text{mm}}\) are in satisfactory agreement with the measurement results for optical transition radiation. The possibility of characterizing X-ray plates by comparing the measured and calculated parametric X‑ray (PXR) angular distributions for several reflecting planes of crystals with an asymmetric reflection geometry and an asymmetry parameter ε less than unity is discussed.- 1 February 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (1) , 240-250
On the Use of Crystals with an Asymmetric Reflection Geometry to Measure the Parameters of Electron Beams
The prospects of using crystals with asymmetric reflection geometry to determine the transverse size of relativistic electron beams based on the results of measuring the angular distributions of their radiation in a thin crystal for two distances between it and a coordinate detector are discussed. Experimental testing of this technique is carried out using an imaging plate as a two-dimensional position-sensitive detector. Measurements are made for an electron energy of 255 MeV and the reflection (220) in a silicon crystal with a thickness of 20 microns and a pixel size of 35 µm2. The distances between the crystal and the detector are 0.5 and 1 m. The obtained values of the horizontal and vertical beam sizes \({{\sigma }_{x}} = 0.32 \pm 0.02\,\,~{\text{mm}}\) and \({{\sigma }_{y}} = 1.35 \pm 0.02~\,\,{\text{mm}}\) are in satisfactory agreement with the measurement results for optical transition radiation. The possibility of characterizing X-ray plates by comparing the measured and calculated parametric X‑ray (PXR) angular distributions for several reflecting planes of crystals with an asymmetric reflection geometry and an asymmetry parameter ε less than unity is discussed.- 1 April 2022
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 16 (2) , 273-280
Effect of Reflection Asymmetry on the Output of the Parametric X-Ray Radiation of Electrons in Crystals
Using an X-ray plate as a two-dimensional position-sensitive detector, the angular distributions of parametric X-ray radiation of electrons with an energy of 255 MeV in a thin silicon crystal are measured in the asymmetric Laue geometry for the reflection planes (111) and \((\bar {1}\bar {1}1).\) The ratio of the measured radiation intensities for these reflection planes is in good agreement with calculations within the framework of the kinematic theory of parametric X-ray radiation if the contribution of the diffraction of photons excited by mechanisms of bremsstrahlung and transition radiation and the influence of the effect of reflection asymmetry on this process are taken into account.- 1 April 2022
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 16 (2) , 273-280
Effect of Reflection Asymmetry on the Output of the Parametric X-Ray Radiation of Electrons in Crystals
Using an X-ray plate as a two-dimensional position-sensitive detector, the angular distributions of parametric X-ray radiation of electrons with an energy of 255 MeV in a thin silicon crystal are measured in the asymmetric Laue geometry for the reflection planes (111) and \((\bar {1}\bar {1}1).\) The ratio of the measured radiation intensities for these reflection planes is in good agreement with calculations within the framework of the kinematic theory of parametric X-ray radiation if the contribution of the diffraction of photons excited by mechanisms of bremsstrahlung and transition radiation and the influence of the effect of reflection asymmetry on this process are taken into account.- 24 March 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1032
A proof-of-principle experiment on a new diagnostic tool for determining beam sizes from angular distributions of parametric X-ray radiation
- 24 March 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1032
A proof-of-principle experiment on a new diagnostic tool for determining beam sizes from angular distributions of parametric X-ray radiation
- 1 May 2020
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 14 (3) , 578-585
Proposal for a Procedure for Measuring the Transverse Dimensions of a Beam of Relativistic Electrons with a Small Longitudinal Size
The possibility of implementing a previously proposed procedure for determining the beam dimensions at a target is analyzed; it includes the measurement of two-dimensional angular distributions of the coherent radiation of fast electrons for two distances between a crystal, where radiation is generated, and a coordinate detector. The use of two mechanisms of parametric X-ray radiation and diffracted transition radiation is considered. The limits of the method sensitivity and the influence of the departure of secondary electrons and photons on them are discussed.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 14 (3) , 578-585
Proposal for a Procedure for Measuring the Transverse Dimensions of a Beam of Relativistic Electrons with a Small Longitudinal Size
The possibility of implementing a previously proposed procedure for determining the beam dimensions at a target is analyzed; it includes the measurement of two-dimensional angular distributions of the coherent radiation of fast electrons for two distances between a crystal, where radiation is generated, and a coordinate detector. The use of two mechanisms of parametric X-ray radiation and diffracted transition radiation is considered. The limits of the method sensitivity and the influence of the departure of secondary electrons and photons on them are discussed.
- 1 April 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (04) , C04025
Method of spatial size measurement of relativistic electrons beams with small bunch length
- 1 April 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (04) , C04025
Method of spatial size measurement of relativistic electrons beams with small bunch length