Andrew E. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew E. Anderson has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
Christopher L. Peters
Department of Orthopaedics, University of Utah, Salt Lake City, UT 84108, USA
18 shared publications- Penny R. Atkins
Scientific Computing and Imaging Institute, University of Utah, 72 S Central Campus Dr, Salt Lake City, UT 84112, USA
17 shared publications - Niccolo M. Fiorentino
Department of Mechanical Engineering, University of Vermont, Burlington, Vermont, USA
11 shared publications K. Bo Foreman
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
10 shared publicationsPenny R. Atkins
Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, USA
10 shared publicationsStephen K. Aoki
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
10 shared publications
Latest Publications
- Open Access
- 27 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (21) , 1695-1702
Lexicon on the Pathomechanics of the Native Hip Joint at Risk for Arthritis
Background: Degenerative osteoarthritis (OA) of the hip often arises from structural abnormalities that alter load distribution, which leads to progressive chondrolabral damage. Although substantial advances have been made, the existing terminology in the field of hip preservation remains heterogeneous and inconsistently applied, limiting scientific communication and treatment standardization. The aim of this article is to link evidence from existing literature to develop a framework in the form of a structured lexicon, one that defines the morphological features and pathomechanical mechanisms that are relevant to the symptomatic, pre-arthritic hip. Methods: This descriptive framework was developed through the synthesis of current biomechanical, radiographic, and clinical evidence, combined with expert consensus from an international, multidisciplinary panel. Foundational concepts were derived from basic science research, including tribology, mechanobiology, and contact mechanics, to establish a unified terminology. Results: Three principal wear modes—instability, impingement, and mixed mechanisms—are proposed, corresponding to distinct pathological loading environments. Wear mechanisms include dysplasia with rim overload and stress-related cartilage failure, impingement with cam-induced shear or pincer rim conflict, and secondary inflammatory degeneration. Wear damage is classified by tissue involvement, encompassing labral degeneration, chondrolabral detachment, staged cartilage delamination, and subchondral bone changes (sclerosis, cystic change). By linking lesion topography to underlying mechanics, this framework has diagnostic and therapeutic relevance as well as encompasses radiographic measurements and clinical features of wear that are pertinent to hip instability and femoroacetabular impingement. Conclusions: This lexicon provides a coherent framework for pre-arthritic hip disease, establishing a shared terminology to guide basic-science research integration and the interpretation of current clinical practice in hip preservation.
- 27 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (21) , 1695-1702
Open AccessLexicon on the Pathomechanics of the Native Hip Joint at Risk for Arthritis
Background: Degenerative osteoarthritis (OA) of the hip often arises from structural abnormalities that alter load distribution, which leads to progressive chondrolabral damage. Although substantial advances have been made, the existing terminology in the field of hip preservation remains heterogeneous and inconsistently applied, limiting scientific communication and treatment standardization. The aim of this article is to link evidence from existing literature to develop a framework in the form of a structured lexicon, one that defines the morphological features and pathomechanical mechanisms that are relevant to the symptomatic, pre-arthritic hip. Methods: This descriptive framework was developed through the synthesis of current biomechanical, radiographic, and clinical evidence, combined with expert consensus from an international, multidisciplinary panel. Foundational concepts were derived from basic science research, including tribology, mechanobiology, and contact mechanics, to establish a unified terminology. Results: Three principal wear modes—instability, impingement, and mixed mechanisms—are proposed, corresponding to distinct pathological loading environments. Wear mechanisms include dysplasia with rim overload and stress-related cartilage failure, impingement with cam-induced shear or pincer rim conflict, and secondary inflammatory degeneration. Wear damage is classified by tissue involvement, encompassing labral degeneration, chondrolabral detachment, staged cartilage delamination, and subchondral bone changes (sclerosis, cystic change). By linking lesion topography to underlying mechanics, this framework has diagnostic and therapeutic relevance as well as encompasses radiographic measurements and clinical features of wear that are pertinent to hip instability and femoroacetabular impingement. Conclusions: This lexicon provides a coherent framework for pre-arthritic hip disease, establishing a shared terminology to guide basic-science research integration and the interpretation of current clinical practice in hip preservation.
- Open Access
- 26 May 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 204, 113384
Validation of a simplified modeling approach to predict strain in the cartilage and labrum of the hip with application to femoroacetabular impingement syndrome
- 26 May 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 204, 113384
Open AccessValidation of a simplified modeling approach to predict strain in the cartilage and labrum of the hip with application to femoroacetabular impingement syndrome
- 22 April 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 179, 107445
Effects of bone deformation on patient-specific finite element predictions of hip chondrolabral mechanics
- 22 April 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 179, 107445
Effects of bone deformation on patient-specific finite element predictions of hip chondrolabral mechanics
- 26 March 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (5) , 865-867
Editorial Comment: 15th Symposium on Joint Preserving and Minimally Invasive Surgery—A Consensus Meeting on Native Hip Instability
- 26 March 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (5) , 865-867
Editorial Comment: 15th Symposium on Joint Preserving and Minimally Invasive Surgery—A Consensus Meeting on Native Hip Instability
- Open Access
- 22 January 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 133, 106767
Standing anterior pelvic tilt is correlated with the proximal femur shape of individuals with cam morphology
- 22 January 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 133, 106767
Open AccessStanding anterior pelvic tilt is correlated with the proximal femur shape of individuals with cam morphology
- 23 August 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (11) , 3208-3221
Accuracy and Reliability of Synthetic Computed Tomography for Model-Based Tracking of Biplane Videoradiography Data
Purpose Biplane videoradiography (BVR) accurately measures hip kinematics in vivo. One downside of BVR is that it typically requires a pelvic computed tomography (CT) scan to reconstruct surfaces for model-based tracking (MBT), increasing the radiation burden to participants. Synthetic CT (sCT) from magnetic resonance imaging (MRI) provides similar volumetric image-based data. The purpose of this study was to assess the effect sCT has on the accuracy and reliability of in vivo hip kinematics from BVR data. Methods Three asymptomatic participants received CT and MRI scans and were imaged with BVR while standing and during gait. Kinematics were calculated from femur and pelvis surfaces reconstructed from CT and sCT scans. Accuracy and inter-/intra-reviewer reliability of hip kinematics using sCT were assessed against CT as the reference using mean absolute error (MAE), mean difference (MD), precision, and inter-/intra-class correlation coefficients (ICCs). Kinematics were represented with and without correction for standing posture. Results MAE, MD, and precision of posture-corrected sCT kinematic results were 0.85, 0.60, and 0.71° for rotations and 0.40, 0.23, and 0.39 mm for translations, respectively. Accuracy of posture-corrected joint angles was within 0.17° of prior MBT validation in the hip, while translation accuracy and precision were greater herein. Kinematic results using CT and sCT had similar reliability. Conclusion The results of this study establish novel reliability metrics for in vivo hip kinematics from BVR. Findings indicate that sCT can be used in lieu of CT to measure in vivo hip kinematics, reducing radiation burden of BVR hip kinematic protocols by up to 73%.
- 23 August 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (11) , 3208-3221
Accuracy and Reliability of Synthetic Computed Tomography for Model-Based Tracking of Biplane Videoradiography Data
Purpose Biplane videoradiography (BVR) accurately measures hip kinematics in vivo. One downside of BVR is that it typically requires a pelvic computed tomography (CT) scan to reconstruct surfaces for model-based tracking (MBT), increasing the radiation burden to participants. Synthetic CT (sCT) from magnetic resonance imaging (MRI) provides similar volumetric image-based data. The purpose of this study was to assess the effect sCT has on the accuracy and reliability of in vivo hip kinematics from BVR data. Methods Three asymptomatic participants received CT and MRI scans and were imaged with BVR while standing and during gait. Kinematics were calculated from femur and pelvis surfaces reconstructed from CT and sCT scans. Accuracy and inter-/intra-reviewer reliability of hip kinematics using sCT were assessed against CT as the reference using mean absolute error (MAE), mean difference (MD), precision, and inter-/intra-class correlation coefficients (ICCs). Kinematics were represented with and without correction for standing posture. Results MAE, MD, and precision of posture-corrected sCT kinematic results were 0.85, 0.60, and 0.71° for rotations and 0.40, 0.23, and 0.39 mm for translations, respectively. Accuracy of posture-corrected joint angles was within 0.17° of prior MBT validation in the hip, while translation accuracy and precision were greater herein. Kinematic results using CT and sCT had similar reliability. Conclusion The results of this study establish novel reliability metrics for in vivo hip kinematics from BVR. Findings indicate that sCT can be used in lieu of CT to measure in vivo hip kinematics, reducing radiation burden of BVR hip kinematic protocols by up to 73%.
- Open Access
- 28 February 2025
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (3) , 1-16
Improving Femoral Torsion Evaluation in Infants Through Analysis of Variability and Reliability in Two-Dimensional and Three-Dimensional Imaging Measurements of the Femoral Neck Axis
The femoral neck axis serves as a critical parameter in evaluating hip joint health, particularly in the pediatric population. Commonly used metrics for evaluating femoral torsion, such as the femoral neck-shaft and femoral anteversion angles, rely heavily on precise definitions of the position and orientation of the femoral neck axis. Current measurement methods employing radiographs and performing two-dimensional (2D) measurements on computed tomography (CT) scans are susceptible to errors due to their reliance on reader experience and the inherent limitations in 2D measurements. We hypothesized that utilizing volumetric data would mitigate these errors and enable more accurate and reproducible measurements of the femoral neck axis using the femoral anteversion and femoral neck-shaft angles. To test this hypothesis, we analyzed a historical collection of postmortem infant femoral and pelvic bones (28 hips) aged 0 to 6.5 months, with an average estimated age of 4.68 ± 1.80 months. Our findings revealed an average neck-shaft angle of 128.00 ± 4.92 deg and femoral anteversion angle of 35.56 ± 11.68 deg across all femurs, consistent with literature values. These measurements obtained from volumetric image data were found to be repeatable and reliable compared to conventional methods. Our study suggests that the proposed methodology offers a standardized approach for obtaining repeatable and reproducible measurements, thus potentially enhancing diagnostic accuracy and clinical decision-making in assessing hip developmental conditions in pediatric patients.
- 28 February 2025
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (3) , 1-16
Open AccessImproving Femoral Torsion Evaluation in Infants Through Analysis of Variability and Reliability in Two-Dimensional and Three-Dimensional Imaging Measurements of the Femoral Neck Axis
The femoral neck axis serves as a critical parameter in evaluating hip joint health, particularly in the pediatric population. Commonly used metrics for evaluating femoral torsion, such as the femoral neck-shaft and femoral anteversion angles, rely heavily on precise definitions of the position and orientation of the femoral neck axis. Current measurement methods employing radiographs and performing two-dimensional (2D) measurements on computed tomography (CT) scans are susceptible to errors due to their reliance on reader experience and the inherent limitations in 2D measurements. We hypothesized that utilizing volumetric data would mitigate these errors and enable more accurate and reproducible measurements of the femoral neck axis using the femoral anteversion and femoral neck-shaft angles. To test this hypothesis, we analyzed a historical collection of postmortem infant femoral and pelvic bones (28 hips) aged 0 to 6.5 months, with an average estimated age of 4.68 ± 1.80 months. Our findings revealed an average neck-shaft angle of 128.00 ± 4.92 deg and femoral anteversion angle of 35.56 ± 11.68 deg across all femurs, consistent with literature values. These measurements obtained from volumetric image data were found to be repeatable and reliable compared to conventional methods. Our study suggests that the proposed methodology offers a standardized approach for obtaining repeatable and reproducible measurements, thus potentially enhancing diagnostic accuracy and clinical decision-making in assessing hip developmental conditions in pediatric patients.
- 17 February 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 123, 106464
Dynamic subtalar joint space measurement analysis following tibiotalar arthrodesis and total ankle replacement
- 17 February 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 123, 106464
Dynamic subtalar joint space measurement analysis following tibiotalar arthrodesis and total ankle replacement
- Open Access
- 6 February 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (2)
Cam Morphology and Sex-Based Differences in the Proximal Femur Anatomy of Collegiate Athletes Without Hip Pain: A 3-Dimensional Statistical Shape Modeling Analysis
Background: Radiographic studies have reported a high prevalence of cam morphology in athletes, especially in male athletes, suggesting these individuals are at an elevated risk of developing femoroacetabular impingement syndrome (FAIS). However, recent research has shown that 2-dimensional measurements do not accurately characterize cam deformities, motivating the need for 3-dimensional (3D) analyses. Purpose: To develop a 3D statistical shape model of the proximal femur to evaluate cam morphology in collegiate athletes through (1) quantifying shape variation, (2) establishing sex-based shape differences, and (3) comparing shapes between male athletes and male cam FAIS patients. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Double-echo steady-state magnetic resonance images were prospectively acquired of the hips of Division I collegiate athletes (28 male, 23 female). An existing data set of computed tomography scans of cam FAIS patients (26 male) and morphologically screened controls (30 male, 17 female) was also evaluated. The proximal femur was segmented, reconstructed into a 3D surface, and analyzed to generate a correspondence model using ShapeWorks. Principal component analysis, parallel analysis, and linear discriminant analysis quantified variation in proximal femoral shape. Results: Variation in the full cohort primarily occurred in the head-neck junction, femoral offset, and location of the greater trochanter relative to the head/neck (mode VIII, adjusted P = .01; modes I and IV, adjusted P = .002 and adjusted P = .003, respectively; modes IV and VIII, adjusted P = .0003 and adjusted P = .0007, resepctively. P < .001). Modes represented anatomic variation significantly different between pairs within a group. Variation between male and female athletes occurred in the concavity of the head at the head-neck junction, length of the femur, and length of the femoral offset (modes I and II, adjusted P = .006 and adjusted P = .009, respectively). Variation between male athletes and male patients and between male patients and male controls occurred in the concavity of the head at the head-neck junction and femoral torsion (mode IV, adjusted P = .02 and adjusted P = .003, respectively). Shape scores, which represented a generalized value of the entire shape, were significantly different between athletes and patients (adjusted P = .003) and patients and controls (adjusted P < .0001). Conclusion: Athletes in our study had a proximal femur shape more similar to morphologically screened controls than FAIS patients. Sex-based differences occurred in athletes in regions where cam morphology typically occurs.
- 6 February 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (2)
Open AccessCam Morphology and Sex-Based Differences in the Proximal Femur Anatomy of Collegiate Athletes Without Hip Pain: A 3-Dimensional Statistical Shape Modeling Analysis
Background: Radiographic studies have reported a high prevalence of cam morphology in athletes, especially in male athletes, suggesting these individuals are at an elevated risk of developing femoroacetabular impingement syndrome (FAIS). However, recent research has shown that 2-dimensional measurements do not accurately characterize cam deformities, motivating the need for 3-dimensional (3D) analyses. Purpose: To develop a 3D statistical shape model of the proximal femur to evaluate cam morphology in collegiate athletes through (1) quantifying shape variation, (2) establishing sex-based shape differences, and (3) comparing shapes between male athletes and male cam FAIS patients. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Double-echo steady-state magnetic resonance images were prospectively acquired of the hips of Division I collegiate athletes (28 male, 23 female). An existing data set of computed tomography scans of cam FAIS patients (26 male) and morphologically screened controls (30 male, 17 female) was also evaluated. The proximal femur was segmented, reconstructed into a 3D surface, and analyzed to generate a correspondence model using ShapeWorks. Principal component analysis, parallel analysis, and linear discriminant analysis quantified variation in proximal femoral shape. Results: Variation in the full cohort primarily occurred in the head-neck junction, femoral offset, and location of the greater trochanter relative to the head/neck (mode VIII, adjusted P = .01; modes I and IV, adjusted P = .002 and adjusted P = .003, respectively; modes IV and VIII, adjusted P = .0003 and adjusted P = .0007, resepctively. P < .001). Modes represented anatomic variation significantly different between pairs within a group. Variation between male and female athletes occurred in the concavity of the head at the head-neck junction, length of the femur, and length of the femoral offset (modes I and II, adjusted P = .006 and adjusted P = .009, respectively). Variation between male athletes and male patients and between male patients and male controls occurred in the concavity of the head at the head-neck junction and femoral torsion (mode IV, adjusted P = .02 and adjusted P = .003, respectively). Shape scores, which represented a generalized value of the entire shape, were significantly different between athletes and patients (adjusted P = .003) and patients and controls (adjusted P < .0001). Conclusion: Athletes in our study had a proximal femur shape more similar to morphologically screened controls than FAIS patients. Sex-based differences occurred in athletes in regions where cam morphology typically occurs.