Robert Edward Day
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Edward Day has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
K. P. Singer
5 shared publicationsK.P. Singer
5 shared publicationsP. D. Breidahl
Royal Perth Hospital
5 shared publicationsP.D. Breidahl
Department of Radiology, Royal Perth Hospital, Perth, Western Australia, Australia
4 shared publications- Ian Duncan Robertson
School of Veterinary Medicine, College of Environment and Life Sciences, Murdoch University, Perth, WA 6150, Australia
3 shared publications Piers J. Yates
Fremantle Hospital, Fremantle, Western Australia
3 shared publications
Latest Publications
- Open Access
- 10 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 650
Augmentative Plating versus Exchange Intramedullary Nailing for the Treatment of Aseptic Non-Unions of the Femoral Shaft—A Biomechanical Study in a SawboneTM Model
Background: Non-unions after intramedullary nailing of femoral shaft fractures are a significant problem. Treatment options such as augmenting with plates or exchange nailing have been proposed. The ideal treatment remains controversial. Methods: Augmentative plating using a 4.5 mm LCP or a 3.2 mm LCP leaving the nail in situ was tested biomechanically and compared to exchange intramedullary nailing in a SawboneTM model of a femoral shaft non-union. Results: The difference of fracture gap motion in axial testing was small. In rotational testing, the exchange nail allowed for the largest amount of motion. The 4.5 mm augmentative plate was the most stable construct in all loading conditions. Conclusions: Augmentative plating using a 4.5 mm LCP plate while leaving the nail in situ is biomechanically superior to exchange intramedullary nailing. A small fragment 3.2 mm LCP is undersized and does not reduce fracture motion sufficiently in a femoral shaft non-union.
- 10 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 650
Open AccessAugmentative Plating versus Exchange Intramedullary Nailing for the Treatment of Aseptic Non-Unions of the Femoral Shaft—A Biomechanical Study in a SawboneTM Model
Background: Non-unions after intramedullary nailing of femoral shaft fractures are a significant problem. Treatment options such as augmenting with plates or exchange nailing have been proposed. The ideal treatment remains controversial. Methods: Augmentative plating using a 4.5 mm LCP or a 3.2 mm LCP leaving the nail in situ was tested biomechanically and compared to exchange intramedullary nailing in a SawboneTM model of a femoral shaft non-union. Results: The difference of fracture gap motion in axial testing was small. In rotational testing, the exchange nail allowed for the largest amount of motion. The 4.5 mm augmentative plate was the most stable construct in all loading conditions. Conclusions: Augmentative plating using a 4.5 mm LCP plate while leaving the nail in situ is biomechanically superior to exchange intramedullary nailing. A small fragment 3.2 mm LCP is undersized and does not reduce fracture motion sufficiently in a femoral shaft non-union.
- 1 December 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (12) , 2894-2899
Plate Positioning in Periprosthetic or Interprosthetic Femur Fractures With Stable Implants—A Biomechanical Study
- 1 December 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (12) , 2894-2899
Plate Positioning in Periprosthetic or Interprosthetic Femur Fractures With Stable Implants—A Biomechanical Study
- 8 January 2016
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 40 (2) , 43-51
Pull-out strength comparison of a novel expanding fastener against an orthopaedic screw in an ovine vertebral body: anex-vivostudy
The purpose of this study was to mechanically test a novel Unthreaded Expandable Fastener (UEF), manufactured using Selective Laser Melting, which was designed for fixation in the cervical lateral mass. The pull-out strength and stiffness of the prototype UEFs was evaluated in a non-osteoporotic ovine bone model against equivalent screws. The prototype UEF demonstrated a 41% increase in failure force and a 60% reduction in failure force standard deviation compared to the screws. All bone samples were micro CT-scanned and no significant differences in bone microstructural properties was found between the screw and UEF sample sets, indicating that the UEFs may be less sensitive to bone quality variation. This increased performance can potentially translate into improved surgical outcome and reduced surgical risk for lateral mass fixation. With further design optimisation, additional improvement in performance over screws may be possible in future studies.
- 8 January 2016
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 40 (2) , 43-51
Pull-out strength comparison of a novel expanding fastener against an orthopaedic screw in an ovine vertebral body: anex-vivostudy
The purpose of this study was to mechanically test a novel Unthreaded Expandable Fastener (UEF), manufactured using Selective Laser Melting, which was designed for fixation in the cervical lateral mass. The pull-out strength and stiffness of the prototype UEFs was evaluated in a non-osteoporotic ovine bone model against equivalent screws. The prototype UEF demonstrated a 41% increase in failure force and a 60% reduction in failure force standard deviation compared to the screws. All bone samples were micro CT-scanned and no significant differences in bone microstructural properties was found between the screw and UEF sample sets, indicating that the UEFs may be less sensitive to bone quality variation. This increased performance can potentially translate into improved surgical outcome and reduced surgical risk for lateral mass fixation. With further design optimisation, additional improvement in performance over screws may be possible in future studies.
- 1 December 2015
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 30 (12) , 2333-2337
Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures
- 1 December 2015
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 30 (12) , 2333-2337
Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures
- 8 July 2015
- Published by IOP Publishing in Biomedical Materials
- Vol. 10 (4) , 045006
Structure design and manufacturing of layered bioceramic scaffolds for load-bearing bone reconstruction
Bioceramic scaffolds with desired bone regeneration functions have the potential to become real alternatives to autologous bone grafts for reconstruction of load-bearing and critical-sized segmental bone defects. The aim of this paper was to develop a layered scaffold structure that has the biodegradable function of common monolithic scaffolds and adequate mechanical function for surgical fixing and after surgery support. The exemplary case of this study is assumed to be a large-segment tibia or femur bone repair. The layered scaffold structure consists of a macro porous hydroxyapatite–wollastonite layer and a strong dense zirconia matrix dense layer. The bio-functional scaffold layer with interconnected freeze-dried porous structures shows excellent apatite formation, cell attachment, and cell proliferation capabilities. The mechanical functional layer provides a bending strength matching that of the compact bone.
- 8 July 2015
- Published by IOP Publishing in Biomedical Materials
- Vol. 10 (4) , 045006
Structure design and manufacturing of layered bioceramic scaffolds for load-bearing bone reconstruction
Bioceramic scaffolds with desired bone regeneration functions have the potential to become real alternatives to autologous bone grafts for reconstruction of load-bearing and critical-sized segmental bone defects. The aim of this paper was to develop a layered scaffold structure that has the biodegradable function of common monolithic scaffolds and adequate mechanical function for surgical fixing and after surgery support. The exemplary case of this study is assumed to be a large-segment tibia or femur bone repair. The layered scaffold structure consists of a macro porous hydroxyapatite–wollastonite layer and a strong dense zirconia matrix dense layer. The bio-functional scaffold layer with interconnected freeze-dried porous structures shows excellent apatite formation, cell attachment, and cell proliferation capabilities. The mechanical functional layer provides a bending strength matching that of the compact bone.
- Open Access
- 29 June 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (12) , 1888-1896
Cyclic mechanical stimulation rescues achilles tendon from degeneration in a bioreactor system
Physiotherapy is one of the effective treatments for tendinopathy, whereby symptoms are relieved by changing the biomechanical environment of the pathological tendon. However, the underlying mechanism remains unclear. In this study, we first established a model of progressive tendinopathy‐like degeneration in the rabbit Achilles. Following ex vivo loading deprivation culture in a bioreactor system for 6 and 12 days, tendons exhibited progressive degenerative changes, abnormal collagen type III production, increased cell apoptosis, and weakened mechanical properties. When intervention was applied at day 7 for another 6 days by using cyclic tensile mechanical stimulation (6% strain, 0.25 Hz, 8 h/day) in a bioreactor, the pathological changes and mechanical properties were almost restored to levels seen in healthy tendon. Our results indicated that a proper biomechanical environment was able to rescue early‐stage pathological changes by increased collagen type I production, decreased collagen degradation and cell apoptosis. The ex vivo model developed in this study allows systematic study on the effect of mechanical stimulation on tendon biology. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1888–1896, 2015.
- 29 June 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (12) , 1888-1896
Open AccessCyclic mechanical stimulation rescues achilles tendon from degeneration in a bioreactor system
Physiotherapy is one of the effective treatments for tendinopathy, whereby symptoms are relieved by changing the biomechanical environment of the pathological tendon. However, the underlying mechanism remains unclear. In this study, we first established a model of progressive tendinopathy‐like degeneration in the rabbit Achilles. Following ex vivo loading deprivation culture in a bioreactor system for 6 and 12 days, tendons exhibited progressive degenerative changes, abnormal collagen type III production, increased cell apoptosis, and weakened mechanical properties. When intervention was applied at day 7 for another 6 days by using cyclic tensile mechanical stimulation (6% strain, 0.25 Hz, 8 h/day) in a bioreactor, the pathological changes and mechanical properties were almost restored to levels seen in healthy tendon. Our results indicated that a proper biomechanical environment was able to rescue early‐stage pathological changes by increased collagen type I production, decreased collagen degradation and cell apoptosis. The ex vivo model developed in this study allows systematic study on the effect of mechanical stimulation on tendon biology. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1888–1896, 2015.
- 1 January 2015
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 28 (02) , 95-103
The effect of intramedullary pin size and monocortical screw configuration on locking compression plate-rod constructs in an in vitro fracture gap model
Summary: Objective: To investigate the effect of intramedullary pin size in combination with various monocortical screw configurations on locking compression plate-rod constructs.Methods: A synthetic bone model with a 40 mm fracture gap was used. Locking compression plates with monocortical locking screws were tested with no pin (LCP-Mono) and intramedullary pins of 20% (LCPR-20), 30% (LCPR-30) and 40% (LCPR-40) of intramedullary diameter. Locking compression plates with bicortical screws (LCP-Bi) were also tested. Screw configurations with two or three screws per fragment modelled long (8-hole), intermediate (6-hole), and short (4-hole) plate working lengths. Responses to axial compression, biplanar four-point bending and axial load-to-failure were recorded.Results: LCP-Bi were not significantly different from LCP-Mono control for any of the outcome variables. In bending, LCPR-20 were not significantly different from LCP-Bi and LCP-Mono. The LCPR-30 were stiffer than LCPR-20 and the controls. The LCPR-40 constructs were stiffer than all other constructs. The addition of an intramedullary pin of any size provided a significant increase in axial stiffness and load to failure. This effect was incremental with increasing intramedullary pin diameter. As plate working length decreased there was a significant increase in stiffness across all constructs.Clinical significance: A pin of any size increases resistance to axial loads whereas a pin of at least 30% intramedullary diameter is required to increase bending stiffness. Short plate working lengths provide maximum stiffness. However, the overwhelming effect of intramedullary pin size obviates the effect of changing working length on construct stiffness.
- 1 January 2015
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 28 (02) , 95-103
The effect of intramedullary pin size and monocortical screw configuration on locking compression plate-rod constructs in an in vitro fracture gap model
Summary: Objective: To investigate the effect of intramedullary pin size in combination with various monocortical screw configurations on locking compression plate-rod constructs.Methods: A synthetic bone model with a 40 mm fracture gap was used. Locking compression plates with monocortical locking screws were tested with no pin (LCP-Mono) and intramedullary pins of 20% (LCPR-20), 30% (LCPR-30) and 40% (LCPR-40) of intramedullary diameter. Locking compression plates with bicortical screws (LCP-Bi) were also tested. Screw configurations with two or three screws per fragment modelled long (8-hole), intermediate (6-hole), and short (4-hole) plate working lengths. Responses to axial compression, biplanar four-point bending and axial load-to-failure were recorded.Results: LCP-Bi were not significantly different from LCP-Mono control for any of the outcome variables. In bending, LCPR-20 were not significantly different from LCP-Bi and LCP-Mono. The LCPR-30 were stiffer than LCPR-20 and the controls. The LCPR-40 constructs were stiffer than all other constructs. The addition of an intramedullary pin of any size provided a significant increase in axial stiffness and load to failure. This effect was incremental with increasing intramedullary pin diameter. As plate working length decreased there was a significant increase in stiffness across all constructs.Clinical significance: A pin of any size increases resistance to axial loads whereas a pin of at least 30% intramedullary diameter is required to increase bending stiffness. Short plate working lengths provide maximum stiffness. However, the overwhelming effect of intramedullary pin size obviates the effect of changing working length on construct stiffness.
- 8 August 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (8) , 1032-1038
Biomechanical Comparison of a Locking Compression Plate Combined With an Intramedullary Pin or a Polyetheretherketone Rod in a Cadaveric Canine Tibia Gap Model
Objective: To compare the biomechanical properties of a 10‐hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30–40% the medullary diameter or a poly‐ether‐ether‐ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model.Study Design: Ex vivostudy.Sample Population: Cadaveric canine tibias (n = 8 pair).Methods: Each construct had a 10‐hole 3.5 mm LCP with 2 screws per fracture fragment using a comminuted tibia gap model. The Steinmann pin constructs had a 2.4 mm intramedullary pin whereas the PEEK‐rod constructs had a 6 mm intramedullary PEEK rod placed. Biomechanical testing included non‐destructive bi‐planar 4 point bending, torsion testing, and destructive axial compression. Testing produced the responses of failure load (N) in axial compression, stiffness (N/mm or N/°) in axial compression, torsion, lateral‐medial, and caudal‐cranial 4 point bending. Screw position within the PEEK‐rods was determined after explantation.Results: The PEEK‐rod constructs were significantly stiffer in axial compression (P < .005), lateral‐medial 4 point bending (P < .001), and in torsional loading (P < .031) than the Steinman pin constructs. There was no significant difference between the constructs for stiffness in caudal‐cranial 4 point bending (P = .32). The PEEK‐rod constructs failed at a significantly higher load than the Steinmann pin constructs (P < .001). All constructs failed by yielding through plastic deformation. Each screw penetrated the PEEK rod in all constructs but the position of the screw varied.Conclusion: PEEK‐rod constructs failed at significantly higher loads and were significantly stiffer in 4 point lateral‐medial bending, axial compression, and torsion when compared with Steinmann pin constructs.
- 8 August 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (8) , 1032-1038
Biomechanical Comparison of a Locking Compression Plate Combined With an Intramedullary Pin or a Polyetheretherketone Rod in a Cadaveric Canine Tibia Gap Model
Objective: To compare the biomechanical properties of a 10‐hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30–40% the medullary diameter or a poly‐ether‐ether‐ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model.Study Design: Ex vivostudy.Sample Population: Cadaveric canine tibias (n = 8 pair).Methods: Each construct had a 10‐hole 3.5 mm LCP with 2 screws per fracture fragment using a comminuted tibia gap model. The Steinmann pin constructs had a 2.4 mm intramedullary pin whereas the PEEK‐rod constructs had a 6 mm intramedullary PEEK rod placed. Biomechanical testing included non‐destructive bi‐planar 4 point bending, torsion testing, and destructive axial compression. Testing produced the responses of failure load (N) in axial compression, stiffness (N/mm or N/°) in axial compression, torsion, lateral‐medial, and caudal‐cranial 4 point bending. Screw position within the PEEK‐rods was determined after explantation.Results: The PEEK‐rod constructs were significantly stiffer in axial compression (P < .005), lateral‐medial 4 point bending (P < .001), and in torsional loading (P < .031) than the Steinman pin constructs. There was no significant difference between the constructs for stiffness in caudal‐cranial 4 point bending (P = .32). The PEEK‐rod constructs failed at a significantly higher load than the Steinmann pin constructs (P < .001). All constructs failed by yielding through plastic deformation. Each screw penetrated the PEEK rod in all constructs but the position of the screw varied.Conclusion: PEEK‐rod constructs failed at significantly higher loads and were significantly stiffer in 4 point lateral‐medial bending, axial compression, and torsion when compared with Steinmann pin constructs.
- 1 June 2014
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 29 (6) , 1308-1312
Can Plate Osteosynthesis of Periprosthethic Femoral Fractures Cause Cement Mantle Failure Around a Stable Hip Stem? A Biomechanical Analysis
- 1 June 2014
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 29 (6) , 1308-1312
Can Plate Osteosynthesis of Periprosthethic Femoral Fractures Cause Cement Mantle Failure Around a Stable Hip Stem? A Biomechanical Analysis
- Open Access
- 21 May 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (4) , 438-441
Custom osteotomy guides for resection of a pelvic chondrosarcoma
- 21 May 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (4) , 438-441
Open AccessCustom osteotomy guides for resection of a pelvic chondrosarcoma