A.-Yong Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A.-Yong Yu has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
An-Peng Pan
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
13 shared publicationsXu Shao
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
8 shared publications- Jinhai Huang
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
7 shared publications Qin-Mei Wang
The Eye Hospital of Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325000 Zhejiang P. R. China
7 shared publicationsKai-Jing Zhou
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China
4 shared publicationsQinmei Wang
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
4 shared publications
Latest Publications
- 30 April 2026
- Published by Elsevier in The Ocular Surface
- Vol. 41, 87-98
A hybrid system integrating deep learning and computer vision for automated blink monitoring and tear film break-up pattern classification
- 30 April 2026
- Published by Elsevier in The Ocular Surface
- Vol. 41, 87-98
A hybrid system integrating deep learning and computer vision for automated blink monitoring and tear film break-up pattern classification
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1)
Accuracy of 8 Intraocular Lens Power Calculation Formulas in Eyes Undergoing Combined Phacovitrectomy
Purpose: To evaluate prediction accuracy using the 4 new‐generation formulas (Barrett Universal II (BUII), Emmetropia Verifying Optical 2.0 (EVO), Kane, and Ladas Super Formula (LSF)) and 4 traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T) in eyes undergoing combined phacovitrectomy. Methods: This is a retrospective case series study. In total, 249 eyes of 249 patients undergoing combined phacovitrectomy were enrolled. A single‐piece foldable monofocal IOL was implanted in each case. The patients were categorized into three subgroups according to axial length (AL) results. Results: Overall, the 4 new‐generation formulas obtained lower mean absolute prediction error (MAE) and median absolute prediction error (MedAE) of 0.42 D to 0.45 D and 0.33 D to 0.36, and higher percentage of prediction error (PE) within ± 0.50 D (65.46%–67.87%). Regarding short eyes, the Haigis formula showed the lowest MedAE of 0.34 D and the highest percentage of PE within ± 0.50 D (68.42%) with no statistical difference, and satisfactory accuracy was achieved using all formulas (all p > 0.05). All formulas displayed better accuracy in medium eyes with lower MAE (0.41 D to 0.46 D), lower MedAE (0.33 D to 0.37 D), and higher percentage of PE within ± 0.50 D (62.42%–69.09%) except for Hoffer Q. Both EVO and BUII formulas revealed higher accuracy in long eyes with lower MAE (0.38 D to 0.41 D), lower MedAE ranging from 0.31 D to 0.33 D, and higher percentage of PE within ± 0.50 D of both 71.74%. Conclusions: The 4 new‐generation formulas showed higher accuracy overall, and higher accuracy was achieved using EVO and BUII formulas in long eyes. All formulas revealed satisfactory accuracy in short eyes. All formulas displayed better accuracy in medium eyes except for Hoffer Q.
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1)
Open AccessAccuracy of 8 Intraocular Lens Power Calculation Formulas in Eyes Undergoing Combined Phacovitrectomy
Purpose: To evaluate prediction accuracy using the 4 new‐generation formulas (Barrett Universal II (BUII), Emmetropia Verifying Optical 2.0 (EVO), Kane, and Ladas Super Formula (LSF)) and 4 traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T) in eyes undergoing combined phacovitrectomy. Methods: This is a retrospective case series study. In total, 249 eyes of 249 patients undergoing combined phacovitrectomy were enrolled. A single‐piece foldable monofocal IOL was implanted in each case. The patients were categorized into three subgroups according to axial length (AL) results. Results: Overall, the 4 new‐generation formulas obtained lower mean absolute prediction error (MAE) and median absolute prediction error (MedAE) of 0.42 D to 0.45 D and 0.33 D to 0.36, and higher percentage of prediction error (PE) within ± 0.50 D (65.46%–67.87%). Regarding short eyes, the Haigis formula showed the lowest MedAE of 0.34 D and the highest percentage of PE within ± 0.50 D (68.42%) with no statistical difference, and satisfactory accuracy was achieved using all formulas (all p > 0.05). All formulas displayed better accuracy in medium eyes with lower MAE (0.41 D to 0.46 D), lower MedAE (0.33 D to 0.37 D), and higher percentage of PE within ± 0.50 D (62.42%–69.09%) except for Hoffer Q. Both EVO and BUII formulas revealed higher accuracy in long eyes with lower MAE (0.38 D to 0.41 D), lower MedAE ranging from 0.31 D to 0.33 D, and higher percentage of PE within ± 0.50 D of both 71.74%. Conclusions: The 4 new‐generation formulas showed higher accuracy overall, and higher accuracy was achieved using EVO and BUII formulas in long eyes. All formulas revealed satisfactory accuracy in short eyes. All formulas displayed better accuracy in medium eyes except for Hoffer Q.
- 6 December 2025
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 110, 101431
Femtosecond lasers in ophthalmology: Mechanisms, clinical breakthroughs, and multidisciplinary frontiers
- 6 December 2025
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 110, 101431
Femtosecond lasers in ophthalmology: Mechanisms, clinical breakthroughs, and multidisciplinary frontiers
- Open Access
- 1 May 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (5) , 22
The Efficacy and Safety of Oxygen-Enriched Rose Bengal and Green Light Corneal Crosslinking
To evaluate the efficacy and safety of Rose Bengal (RB) and green light crosslinking (RGX) with supplemental oxygen. Rabbits were divided into three groups. Rabbits in the control group were de-epithelialized and served as controls. Rabbits in the RGX-nO2 group were de-epithelialized, stained with 0.1% RB for 20 minutes, and then exposed to green light at 0.25 W/cm2 for 10 minutes in an ambient atmospheric oxygen environment. Rabbits in the RGX-hO2 group received the same treatment as group 2, but supplemental oxygen was given to the ocular surface during irradiation. Central corneal thickness was measured at various points during RGX. After RGX, corneal microstructure, corneal biomechanics, and resistance to enzyme lysis were evaluated. RGX-hO2 and RGX-nO2 significantly increased the corneal tensile strength by factors of 1.76 and 1.46, respectively. The times for complete corneal digestion within the RGX-hO2, RGX-nO2, and control groups were 23.2 ± 1.1 hours, 18.0 ± 2.0 hours, and 8.4± 0.9 hours. The average collagen fibril diameters (43.58 ± 0.93 nm, 40.46 ± 1.11 nm, and 35.25 ± 0.75 nm, respectively) and surface-to-surface spacing (11.67 ± 1.91 nm, 15.51 ± 1.66 nm, and 24.93 ± 1.95 nm, respectively) also differed statistically among the three groups. No evidence of endothelial or stromal cell damage was detected by endothelial staining or TUNEL assay. Increasing the concentration of oxygen during the irradiation process enhances RGX efficacy without causing obvious damage to a rabbit's endothelium or stromal cells. The study can potentially help with improvement of the existing clinical crosslinking protocol.
- 1 May 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (5) , 22
Open AccessThe Efficacy and Safety of Oxygen-Enriched Rose Bengal and Green Light Corneal Crosslinking
To evaluate the efficacy and safety of Rose Bengal (RB) and green light crosslinking (RGX) with supplemental oxygen. Rabbits were divided into three groups. Rabbits in the control group were de-epithelialized and served as controls. Rabbits in the RGX-nO2 group were de-epithelialized, stained with 0.1% RB for 20 minutes, and then exposed to green light at 0.25 W/cm2 for 10 minutes in an ambient atmospheric oxygen environment. Rabbits in the RGX-hO2 group received the same treatment as group 2, but supplemental oxygen was given to the ocular surface during irradiation. Central corneal thickness was measured at various points during RGX. After RGX, corneal microstructure, corneal biomechanics, and resistance to enzyme lysis were evaluated. RGX-hO2 and RGX-nO2 significantly increased the corneal tensile strength by factors of 1.76 and 1.46, respectively. The times for complete corneal digestion within the RGX-hO2, RGX-nO2, and control groups were 23.2 ± 1.1 hours, 18.0 ± 2.0 hours, and 8.4± 0.9 hours. The average collagen fibril diameters (43.58 ± 0.93 nm, 40.46 ± 1.11 nm, and 35.25 ± 0.75 nm, respectively) and surface-to-surface spacing (11.67 ± 1.91 nm, 15.51 ± 1.66 nm, and 24.93 ± 1.95 nm, respectively) also differed statistically among the three groups. No evidence of endothelial or stromal cell damage was detected by endothelial staining or TUNEL assay. Increasing the concentration of oxygen during the irradiation process enhances RGX efficacy without causing obvious damage to a rabbit's endothelium or stromal cells. The study can potentially help with improvement of the existing clinical crosslinking protocol.
- Open Access
- 2 February 2025
- Published by Springer Nature in Eye and Vision
- Vol. 12 (1) , 1-14
Real-world study of phakic refractive lens for correction of high myopia
Background: To assess the safety and efficacy of phakic refractive lens (PRL) implantation for correcting high myopia, as well as an ophthalmic viscosurgical device-free (OVD-free) method for PRL implantation. Methods: In this real-world prospective study, consecutive patients implanted with PRL in one or both eyes were enrolled. Based on the surgical techniques used, the eyes were divided into the OVD-free method group and the conventional method group. The patients were examined 2 h after surgery and were scheduled for follow-up at 1 day, 1 week, 1 month, 3 months, 6 months, and 12 months. The corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), the manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and lens vault were assessed postoperatively. Corneal endothelial cell density (ECD) was measured at the 3- and 12-month postoperative visits. Results: Fifty-seven consecutive patients (108 eyes) were enrolled. At the 3-month postoperative visit, both mean UDVA and CDVA were significantly improved after PRL implantation (0.19 ± 0.21 and 0.01 ± 0.14 logMAR) with efficacy index and safety index of 0.92 and 1.30, respectively. None of the eyes had any loss of CDVA. The percentage of eyes within ± 0.50 D and ± 1.00 D of target refraction was 58% and 83%, respectively. Mean MRSE changed from − 14.49 ± 4.22 D, preoperatively, to − 1.22 ± 1.26 D at 1 day (P < 0.001) and remained stable thereafter. Mean endothelial cell loss was 11.3%, 9.6%, respectively, at 3 and 12 months, with no significant difference between the two follow-ups (P = 0.395). Fifty-nine eyes received the OVD-free method, and 49 eyes received the conventional method. The OVD-free method demonstrated a significant reduction in the incidence of early acute IOP elevations (28.8% vs. 53.1%, P = 0.022) compared to the conventional method. The difference of initial endothelial cell loss (9.4 ± 14.2% vs. 13.6 ± 14.6%) between the two groups trended toward significance (P = 0.056). In both groups, no other major complications were observed up to 12-month follow-up. Conclusions: PRL implantation was a safe, efficient, predictable and stable method for correcting high myopia. The potential of lower incidence of early acute IOP elevations makes the OVD-free method a promising alternative to the conventional method. Trail registration: Chinese Clinical Trial Registry, ChiCTR2100043600. Registered on 23 February 2021, https://www.chictr.org.cn/showproj.html?proj=122229
- 2 February 2025
- Published by Springer Nature in Eye and Vision
- Vol. 12 (1) , 1-14
Open AccessReal-world study of phakic refractive lens for correction of high myopia
Background: To assess the safety and efficacy of phakic refractive lens (PRL) implantation for correcting high myopia, as well as an ophthalmic viscosurgical device-free (OVD-free) method for PRL implantation. Methods: In this real-world prospective study, consecutive patients implanted with PRL in one or both eyes were enrolled. Based on the surgical techniques used, the eyes were divided into the OVD-free method group and the conventional method group. The patients were examined 2 h after surgery and were scheduled for follow-up at 1 day, 1 week, 1 month, 3 months, 6 months, and 12 months. The corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), the manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and lens vault were assessed postoperatively. Corneal endothelial cell density (ECD) was measured at the 3- and 12-month postoperative visits. Results: Fifty-seven consecutive patients (108 eyes) were enrolled. At the 3-month postoperative visit, both mean UDVA and CDVA were significantly improved after PRL implantation (0.19 ± 0.21 and 0.01 ± 0.14 logMAR) with efficacy index and safety index of 0.92 and 1.30, respectively. None of the eyes had any loss of CDVA. The percentage of eyes within ± 0.50 D and ± 1.00 D of target refraction was 58% and 83%, respectively. Mean MRSE changed from − 14.49 ± 4.22 D, preoperatively, to − 1.22 ± 1.26 D at 1 day (P < 0.001) and remained stable thereafter. Mean endothelial cell loss was 11.3%, 9.6%, respectively, at 3 and 12 months, with no significant difference between the two follow-ups (P = 0.395). Fifty-nine eyes received the OVD-free method, and 49 eyes received the conventional method. The OVD-free method demonstrated a significant reduction in the incidence of early acute IOP elevations (28.8% vs. 53.1%, P = 0.022) compared to the conventional method. The difference of initial endothelial cell loss (9.4 ± 14.2% vs. 13.6 ± 14.6%) between the two groups trended toward significance (P = 0.056). In both groups, no other major complications were observed up to 12-month follow-up. Conclusions: PRL implantation was a safe, efficient, predictable and stable method for correcting high myopia. The potential of lower incidence of early acute IOP elevations makes the OVD-free method a promising alternative to the conventional method. Trail registration: Chinese Clinical Trial Registry, ChiCTR2100043600. Registered on 23 February 2021, https://www.chictr.org.cn/showproj.html?proj=122229
- 29 January 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (6) , 1585-1596
FoxO1 promotes high glucose-induced inflammation and cataract formation via JAK1/STAT1
Purpose To investigate whether in diabetic cataract (DC), FoxO1 regulates high glucose (HG)-induced activation of NLRC4/IL-6 inflammatory mediators in human lens epithelial cells (SRA01/04) via the JAK1/STAT1 pathway, leading to cataract formation. Methods Expression levels of FoxO1, inflammatory factor IL-6 and inflammatory vesicle NLRC4 were examined in SRA01/04 under high glucose (HG) stress at 25–150 mM. Rat lenses were also cultured using HG medium with or without the addition of the FoxO1 inhibitor AS1842856 and the JAK1 agonist RO8191. 5.5 mM glucose concentration group (NG) was used as a control. Real-time PCR, Western blots, and immunofluorescent staining evaluated the mRNA and protein levels of FoxO1, NLRC4, and IL-6. Apoptosis, cell viability, and EDU Staining were also assessed. Results HG stimulation induced elevated FoxO1 expression and caused NLRC4/IL-6 activation in a concentration-dependent manner. Whereas knockdown of FoxO1 inhibited the high expression of NLRC4/IL-6 inflammatory mediators in response to HG stimulation. The growth of SRA01/04 was inhibited under HG condition, and the cell proliferation ability was restored and even promoted by knocking out FoxO1. HG incubation of rat lens resulted in lens clouding and cataract formation, which was prevented by AS1842856 treatment and reversed by RO8191. Conclusion FoxO1 positively regulates HG-induced SRA01/04 inflammatory activation through the JAK1/STAT1 pathway and promotes DC. This provides a feasible strategy for the treatment of diabetic cataract.
- 29 January 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (6) , 1585-1596
FoxO1 promotes high glucose-induced inflammation and cataract formation via JAK1/STAT1
Purpose To investigate whether in diabetic cataract (DC), FoxO1 regulates high glucose (HG)-induced activation of NLRC4/IL-6 inflammatory mediators in human lens epithelial cells (SRA01/04) via the JAK1/STAT1 pathway, leading to cataract formation. Methods Expression levels of FoxO1, inflammatory factor IL-6 and inflammatory vesicle NLRC4 were examined in SRA01/04 under high glucose (HG) stress at 25–150 mM. Rat lenses were also cultured using HG medium with or without the addition of the FoxO1 inhibitor AS1842856 and the JAK1 agonist RO8191. 5.5 mM glucose concentration group (NG) was used as a control. Real-time PCR, Western blots, and immunofluorescent staining evaluated the mRNA and protein levels of FoxO1, NLRC4, and IL-6. Apoptosis, cell viability, and EDU Staining were also assessed. Results HG stimulation induced elevated FoxO1 expression and caused NLRC4/IL-6 activation in a concentration-dependent manner. Whereas knockdown of FoxO1 inhibited the high expression of NLRC4/IL-6 inflammatory mediators in response to HG stimulation. The growth of SRA01/04 was inhibited under HG condition, and the cell proliferation ability was restored and even promoted by knocking out FoxO1. HG incubation of rat lens resulted in lens clouding and cataract formation, which was prevented by AS1842856 treatment and reversed by RO8191. Conclusion FoxO1 positively regulates HG-induced SRA01/04 inflammatory activation through the JAK1/STAT1 pathway and promotes DC. This provides a feasible strategy for the treatment of diabetic cataract.
- 26 November 2024
- Published by Elsevier in Experimental Eye Research
- Vol. 250, 110183
Comparison of rose bengal-green light scleral crosslinking in rabbit eyes using different infiltration protocols - An Ex Vivo study
- 26 November 2024
- Published by Elsevier in Experimental Eye Research
- Vol. 250, 110183
Comparison of rose bengal-green light scleral crosslinking in rabbit eyes using different infiltration protocols - An Ex Vivo study
- Open Access
- 7 October 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-9
Repeatability and agreement of two swept-source optical coherence tomographers and scheimpflug imaging for measurements of corneal curvature
To evaluate the repeatability and agreement of two swept-source optical coherence tomographers and Scheimpflug imaging for corneal curvature in healthy subjects to obtain data on the clinical application of a new device. This prospective study was conducted in January and February 2021 with 100 healthy subjects at the Eye Hospital of Wenzhou Medical University. Simulated keratometry (Sim-K), posterior keratometry (Kp), total corneal power (TCP), and total corneal astigmatism (TCA) were measured with CASIA2, Anterion, and Pentacam. Within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to assess inter-device repeatability. Bland–Altman analysis was performed to determine inter-device agreement. The three devices showed good repeatability for Sim-K, Kp, and TCP with all ICC > 0.980. Pentacam showed the highest repeatability (ICC ≥ 0.993; ICC ≥ 0.993) while the CASIA2 demonstrated the lowest repeatability (ICC: ≥ 0.986; ICC: ≥ 0.985) for Sim-K and TCP. Anterion and CASIA2 revealed better repeatability (ICC ≥ 0.998; ICC ≥ 0.981) for Kp than Pentacam (ICC ≥ 0.980). Pentacam and Anterion showed good repeatability for TCA (ICC: 0.935 and 0.916), whereas the CASIA2 showed moderate repeatability (ICC: 0.836). Three instruments demonstrated good agreement with the maximum absolute 95% Limits of agreement (LoA) of 1.00 D for Sim-K, Kp, and TCP. Wide LoA were found for TCA with the maximum absolute 95% LoA ≥ 0.66 D between the three devices. In healthy subjects, the three devices (Pentacam, Anterion and CASIA2) displayed comparable repeatability and accuracy for SimK, Kp, and TCP, and could be used interchangeably for these parameters. However, TCA measured by the three devices was not interchangeable. Chinese Clinical Trial Registry Center (10/10/2020, ChiCTR2000038959).
- 7 October 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-9
Open AccessRepeatability and agreement of two swept-source optical coherence tomographers and scheimpflug imaging for measurements of corneal curvature
To evaluate the repeatability and agreement of two swept-source optical coherence tomographers and Scheimpflug imaging for corneal curvature in healthy subjects to obtain data on the clinical application of a new device. This prospective study was conducted in January and February 2021 with 100 healthy subjects at the Eye Hospital of Wenzhou Medical University. Simulated keratometry (Sim-K), posterior keratometry (Kp), total corneal power (TCP), and total corneal astigmatism (TCA) were measured with CASIA2, Anterion, and Pentacam. Within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to assess inter-device repeatability. Bland–Altman analysis was performed to determine inter-device agreement. The three devices showed good repeatability for Sim-K, Kp, and TCP with all ICC > 0.980. Pentacam showed the highest repeatability (ICC ≥ 0.993; ICC ≥ 0.993) while the CASIA2 demonstrated the lowest repeatability (ICC: ≥ 0.986; ICC: ≥ 0.985) for Sim-K and TCP. Anterion and CASIA2 revealed better repeatability (ICC ≥ 0.998; ICC ≥ 0.981) for Kp than Pentacam (ICC ≥ 0.980). Pentacam and Anterion showed good repeatability for TCA (ICC: 0.935 and 0.916), whereas the CASIA2 showed moderate repeatability (ICC: 0.836). Three instruments demonstrated good agreement with the maximum absolute 95% Limits of agreement (LoA) of 1.00 D for Sim-K, Kp, and TCP. Wide LoA were found for TCA with the maximum absolute 95% LoA ≥ 0.66 D between the three devices. In healthy subjects, the three devices (Pentacam, Anterion and CASIA2) displayed comparable repeatability and accuracy for SimK, Kp, and TCP, and could be used interchangeably for these parameters. However, TCA measured by the three devices was not interchangeable. Chinese Clinical Trial Registry Center (10/10/2020, ChiCTR2000038959).
- 6 May 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 265, 200-212
Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component
- 6 May 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 265, 200-212
Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component
- Open Access
- 1 December 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (12) , 6
Preliminary Application of a Continuous Functional Contrast Visual Acuity System in the Assessment of Visual Function in Dry Eye Patients
Purpose: To investigate the feasibility and efficacy of a continuous functional contrast visual acuity (CFCVA) system in the assessment of visual function in dry eye disease (DED). Methods: Twenty patients with DED and 15 normal controls were recruited. Subjective symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, and tear film stability was assessed by a noninvasive corneal topographer. Under natural blinking conditions, the custom-built CFCVA system was used to take serial visual acuity measurements at 100%, 25%, 10%, and 5% contrast for 60 seconds. A 5-minute measurement at a 100% contrast level was defined as the stress test (ST). Mean CFCVA was defined, and visual maintenance ratio (VMR) was the ratio of mean CFCVA divided by baseline visual acuity. Results: In both groups, VMR decreased and mean CFCVA (logarithm of the minimum angle of resolution) increased with decreasing optotype contrast (from 100% to 5%). In ST, the ST VMR at the fourth and fifth minutes (VMR54 and VMR55) showed the strongest correlations with OSDI total, ocular symptoms, and vision-related function (−0.646 and −0.598, −0.688 and −0.693, and −0.599 and −0.555, respectively, P < 0.05). VMR54 and VMR55 also demonstrated the best discriminating ability for detecting DED, with areas under the curve of 0.903 and 0.867, respectively. Conclusions: Extending the continuous measuring time was more effective for detecting vision-related functional abnormalities in patients with DED than simply decreasing the optotype contrast level. Translational Relevance: The proposed CFCVA system and associated parameters offer a potential method for quantifying and interpreting the visual symptoms of DED in clinical care.
- 1 December 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (12) , 6
Open AccessPreliminary Application of a Continuous Functional Contrast Visual Acuity System in the Assessment of Visual Function in Dry Eye Patients
Purpose: To investigate the feasibility and efficacy of a continuous functional contrast visual acuity (CFCVA) system in the assessment of visual function in dry eye disease (DED). Methods: Twenty patients with DED and 15 normal controls were recruited. Subjective symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, and tear film stability was assessed by a noninvasive corneal topographer. Under natural blinking conditions, the custom-built CFCVA system was used to take serial visual acuity measurements at 100%, 25%, 10%, and 5% contrast for 60 seconds. A 5-minute measurement at a 100% contrast level was defined as the stress test (ST). Mean CFCVA was defined, and visual maintenance ratio (VMR) was the ratio of mean CFCVA divided by baseline visual acuity. Results: In both groups, VMR decreased and mean CFCVA (logarithm of the minimum angle of resolution) increased with decreasing optotype contrast (from 100% to 5%). In ST, the ST VMR at the fourth and fifth minutes (VMR54 and VMR55) showed the strongest correlations with OSDI total, ocular symptoms, and vision-related function (−0.646 and −0.598, −0.688 and −0.693, and −0.599 and −0.555, respectively, P < 0.05). VMR54 and VMR55 also demonstrated the best discriminating ability for detecting DED, with areas under the curve of 0.903 and 0.867, respectively. Conclusions: Extending the continuous measuring time was more effective for detecting vision-related functional abnormalities in patients with DED than simply decreasing the optotype contrast level. Translational Relevance: The proposed CFCVA system and associated parameters offer a potential method for quantifying and interpreting the visual symptoms of DED in clinical care.