Farshid Ghezelbash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Farshid Ghezelbash has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A. Plamondon
Institut de recherche Robert Sauvé en santé et en sécurité du travail, Montréal, Canada
2 shared publicationsAboulfazl Shirazi-Adl
2 shared publications- Aboulfazl Shirazi-Adl
Division of Applied Mechanics, Department of Mechanical Engineering, Polytechnique Montréal, Québec, Canada
2 shared publications N. Arjmand
Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publicationsNavid Arjmand
Sharif University of Technology
2 shared publicationsZ. El-Ouaaid
Division of Applied Mechanics, Department of Mechanical Engineering, Ecole Polytechnique, Montréal, Quebec, Canada; Institut de recherche Robert Sauvé en santé et en sécurité du travail, Montréal, Canada
2 shared publications
Latest Publications
- 13 February 2023
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 10 (5) , 1705-1718
Tissue-mimetic hybrid bioadhesives for intervertebral disc repair
Tissue-mimetic hybrid bioadhesives for the repair of intervertebral disc after nucleotomy is proposed, comprising a viscoelastic glue for delivering cells to fill the cavity and a tough adhesive sealant to prevent re-herniation post-nucleotomy.
- 13 February 2023
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 10 (5) , 1705-1718
Tissue-mimetic hybrid bioadhesives for intervertebral disc repair
Tissue-mimetic hybrid bioadhesives for the repair of intervertebral disc after nucleotomy is proposed, comprising a viscoelastic glue for delivering cells to fill the cavity and a tough adhesive sealant to prevent re-herniation post-nucleotomy.
- 1 January 2023
- Published by Institut de recherche Robert-Sauvé en santé et en sécurité du travail
Fusion et validation de modèles musculosquelettiques de la colonne lombaire pour la prévention et la réadaptation des travailleurs
Les charges imposées sur la colonne vertébrale lombaire constituent un facteur de risque important pour les maux de dos. Connaître la distribution de ces forces internes lors d’activités de travail est nécessaire autant en prévention qu’en réadaptation des travailleurs. La modélisation musculosquelettique (MS) de la colonne vertébrale est la seule approche non invasive permettant d’estimer les charges sur les structures internes de la colonne. Deux modèles ont été développés au Québec, soient un modèle par éléments finis (MEF) guidé par le mouvement et un autre guidé par des mesures électromyographiques (EMG) d’activation musculaire (modèle MEMG). Ces modèles sont donc sensibles aux stratégies individuelles de mouvement et d’activation musculaire. Un troisième modèle, permettant l’estimation de la stabilité lombaire, est aussi attaché au MEF, permettant de mieux comprendre, entre autres, les marges de stabilité et le risque d’hyper mobilité. Les objectifs généraux de la présente étude sont (1) de fusionner les trois modèles MS (MEF, MEMF, stabilité lombaire) en un modèle hybride en vue d’obtenir la solution la plus sensible aux stratégies individuelles de mouvement et d’activation des muscles du tronc, (2) de retenir les caractéristiques en lien avec la personnalisation de ce modèle tout en y intégrant les courbures naturelles de la colonne vertébrale et (3) d’implanter la technique d’étalonnage sous-maximale des signaux EMG et d’en faire la validation. Le présent rapport de recherche résume le contenu de trois articles qui ont détaillé les résultats en lien avec ces objectifs. Les résultats de ce projet ont confirmé, avec deux jeux de données indépendants impliquant des tâches statiques (article 1) et dynamiques (article 2) de levers de charges, que la technique d’étalonnage maximale des signaux EMG peut être remplacée par la technique sous-maximale. Le succès de cette validation permet d’utiliser un modèle MS solutionné par EMG chez des travailleurs souffrant de lombalgie ou n’ayant pas les aptitudes à produire les contractions maximales volontaires nécessaires à la technique d’étalonnage maximale. De plus, il a été démontré que la personnalisation du profil de la colonne vertébrale doit être prise en compte dans la modélisation MS de la colonne vertébrale (article 3). L’ensemble des résultats démontrent que les estimations portant sur le chargement articulaire (compression et cisaillement) et les indices de stabilité lombaire sont beaucoup moins sujettes aux erreurs que les estimations des forces musculaires et semblent donc à privilégier pour documenter l’exposition à différentes tâches ainsi que les effets d’intervention. Les applications de ce modèle hybride seront ainsi possibles pour l’évaluation du risque associé à différentes tâches de travail ou à titre de mesures de résultats pour évaluer les effets d’interventions ergonomiques ou cliniques. Loads on the lumbar spinal column are a significant risk factor for backaches. It is important to know the distribution of these internal forces during work activities both for prevention and for worker rehabilitation. Musculoskeletal (MS) modelling of the spinal column is the only non-invasive approach that can estimate loads on the spinal column’s internal structures.
- 1 January 2023
- Published by Institut de recherche Robert-Sauvé en santé et en sécurité du travail
Fusion et validation de modèles musculosquelettiques de la colonne lombaire pour la prévention et la réadaptation des travailleurs
Les charges imposées sur la colonne vertébrale lombaire constituent un facteur de risque important pour les maux de dos. Connaître la distribution de ces forces internes lors d’activités de travail est nécessaire autant en prévention qu’en réadaptation des travailleurs. La modélisation musculosquelettique (MS) de la colonne vertébrale est la seule approche non invasive permettant d’estimer les charges sur les structures internes de la colonne. Deux modèles ont été développés au Québec, soient un modèle par éléments finis (MEF) guidé par le mouvement et un autre guidé par des mesures électromyographiques (EMG) d’activation musculaire (modèle MEMG). Ces modèles sont donc sensibles aux stratégies individuelles de mouvement et d’activation musculaire. Un troisième modèle, permettant l’estimation de la stabilité lombaire, est aussi attaché au MEF, permettant de mieux comprendre, entre autres, les marges de stabilité et le risque d’hyper mobilité. Les objectifs généraux de la présente étude sont (1) de fusionner les trois modèles MS (MEF, MEMF, stabilité lombaire) en un modèle hybride en vue d’obtenir la solution la plus sensible aux stratégies individuelles de mouvement et d’activation des muscles du tronc, (2) de retenir les caractéristiques en lien avec la personnalisation de ce modèle tout en y intégrant les courbures naturelles de la colonne vertébrale et (3) d’implanter la technique d’étalonnage sous-maximale des signaux EMG et d’en faire la validation. Le présent rapport de recherche résume le contenu de trois articles qui ont détaillé les résultats en lien avec ces objectifs. Les résultats de ce projet ont confirmé, avec deux jeux de données indépendants impliquant des tâches statiques (article 1) et dynamiques (article 2) de levers de charges, que la technique d’étalonnage maximale des signaux EMG peut être remplacée par la technique sous-maximale. Le succès de cette validation permet d’utiliser un modèle MS solutionné par EMG chez des travailleurs souffrant de lombalgie ou n’ayant pas les aptitudes à produire les contractions maximales volontaires nécessaires à la technique d’étalonnage maximale. De plus, il a été démontré que la personnalisation du profil de la colonne vertébrale doit être prise en compte dans la modélisation MS de la colonne vertébrale (article 3). L’ensemble des résultats démontrent que les estimations portant sur le chargement articulaire (compression et cisaillement) et les indices de stabilité lombaire sont beaucoup moins sujettes aux erreurs que les estimations des forces musculaires et semblent donc à privilégier pour documenter l’exposition à différentes tâches ainsi que les effets d’intervention. Les applications de ce modèle hybride seront ainsi possibles pour l’évaluation du risque associé à différentes tâches de travail ou à titre de mesures de résultats pour évaluer les effets d’interventions ergonomiques ou cliniques. Loads on the lumbar spinal column are a significant risk factor for backaches. It is important to know the distribution of these internal forces during work activities both for prevention and for worker rehabilitation. Musculoskeletal (MS) modelling of the spinal column is the only non-invasive approach that can estimate loads on the spinal column’s internal structures.
- 1 October 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (14) , 3492-3501
Effects of sex, age, body height and body weight on spinal loads: Sensitivity analyses in a subject-specific trunk musculoskeletal model
- 1 October 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (14) , 3492-3501
Effects of sex, age, body height and body weight on spinal loads: Sensitivity analyses in a subject-specific trunk musculoskeletal model
- 12 May 2016
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 15 (6) , 1699-1712
Subject-specific biomechanics of trunk: musculoskeletal scaling, internal loads and intradiscal pressure estimation
Development of a subject-specific computational musculoskeletal trunk model (accounting for age, sex, body weight and body height), estimation of muscle forces and internal loads as well as subsequent validation by comparison with measured intradiscal pressure in various lifting tasks are novel, important and challenging. The objective of the present study is twofold. First, it aims to update and personalize the passive and active structures in an existing musculoskeletal kinematics-driven finite element model. The scaling scheme used an existing imaging database and biomechanical principles to adjust muscle geometries/cross-sectional-areas and passive joint geometry/properties in accordance with subjects’ sex, age, body weight and body height. Second, using predictions of a detailed passive finite element model of the ligamentous lumbar spine, a novel nonlinear regression equation was proposed that relates the intradiscal pressure (IDP) at the L4–L5 disc to its compression force and intersegmental flexion rotation. Predicted IDPs and muscle activities of the personalized models under various tasks are found in good-to-excellent agreement with reported measurements. Results indicate the importance of personal parameters when computing muscle forces and spinal loads especially at larger trunk flexion angles as minor changes in individual parameters yielded up to 30 % differences in spinal forces. For more accurate subject-specific estimation of spinal loads and muscle activities, such a comprehensive trunk model should be used that accounts for subject’s personalized features on active musculature and passive spinal structure.
- 12 May 2016
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 15 (6) , 1699-1712
Subject-specific biomechanics of trunk: musculoskeletal scaling, internal loads and intradiscal pressure estimation
Development of a subject-specific computational musculoskeletal trunk model (accounting for age, sex, body weight and body height), estimation of muscle forces and internal loads as well as subsequent validation by comparison with measured intradiscal pressure in various lifting tasks are novel, important and challenging. The objective of the present study is twofold. First, it aims to update and personalize the passive and active structures in an existing musculoskeletal kinematics-driven finite element model. The scaling scheme used an existing imaging database and biomechanical principles to adjust muscle geometries/cross-sectional-areas and passive joint geometry/properties in accordance with subjects’ sex, age, body weight and body height. Second, using predictions of a detailed passive finite element model of the ligamentous lumbar spine, a novel nonlinear regression equation was proposed that relates the intradiscal pressure (IDP) at the L4–L5 disc to its compression force and intersegmental flexion rotation. Predicted IDPs and muscle activities of the personalized models under various tasks are found in good-to-excellent agreement with reported measurements. Results indicate the importance of personal parameters when computing muscle forces and spinal loads especially at larger trunk flexion angles as minor changes in individual parameters yielded up to 30 % differences in spinal forces. For more accurate subject-specific estimation of spinal loads and muscle activities, such a comprehensive trunk model should be used that accounts for subject’s personalized features on active musculature and passive spinal structure.
- 17 September 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 18 (16) , 1760-1767
Effect of intervertebral translational flexibilities on estimations of trunk muscle forces, kinematics, loads, and stability
Due to the complexity of the human spinal motion segments, the intervertebral joints are often simulated in the musculoskeletal trunk models as pivots thus allowing no translational degrees of freedom (DOFs). This work aims to investigate, for the first time, the effect of such widely used assumption on trunk muscle forces, spinal loads, kinematics, and stability during a number of static activities. To address this, the shear deformable beam elements used in our nonlinear finite element (OFE) musculoskeletal model of the trunk were either substantially stiffened in translational directions (SFE model) or replaced by hinge joints interconnected through rotational springs (HFE model). Results indicated that ignoring intervertebral translational DOFs had in general low to moderate impact on model predictions. Compared with the OFE model, the SFE and HFE models predicted generally larger L4-L5 and L5-S1 compression and shear loads, especially for tasks with greater trunk angles; differences reached ~15% for the L4-L5 compression, ~36% for the L4-L5 shear and ~18% for the L5-S1 shear loads. Such differences increased, as location of the hinge joints in the HFE model moved from the mid-disc height to either the lower or upper endplates. Stability analyses of these models for some select activities revealed small changes in predicted margin of stability. Model studies dealing exclusively with the estimation of spinal loads and/or stability may, hence with small loss of accuracy, neglect intervertebral translational DOFs at smaller trunk flexion angles for the sake of computational simplicity.
- 17 September 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 18 (16) , 1760-1767
Effect of intervertebral translational flexibilities on estimations of trunk muscle forces, kinematics, loads, and stability
Due to the complexity of the human spinal motion segments, the intervertebral joints are often simulated in the musculoskeletal trunk models as pivots thus allowing no translational degrees of freedom (DOFs). This work aims to investigate, for the first time, the effect of such widely used assumption on trunk muscle forces, spinal loads, kinematics, and stability during a number of static activities. To address this, the shear deformable beam elements used in our nonlinear finite element (OFE) musculoskeletal model of the trunk were either substantially stiffened in translational directions (SFE model) or replaced by hinge joints interconnected through rotational springs (HFE model). Results indicated that ignoring intervertebral translational DOFs had in general low to moderate impact on model predictions. Compared with the OFE model, the SFE and HFE models predicted generally larger L4-L5 and L5-S1 compression and shear loads, especially for tasks with greater trunk angles; differences reached ~15% for the L4-L5 compression, ~36% for the L4-L5 shear and ~18% for the L5-S1 shear loads. Such differences increased, as location of the hinge joints in the HFE model moved from the mid-disc height to either the lower or upper endplates. Stability analyses of these models for some select activities revealed small changes in predicted margin of stability. Model studies dealing exclusively with the estimation of spinal loads and/or stability may, hence with small loss of accuracy, neglect intervertebral translational DOFs at smaller trunk flexion angles for the sake of computational simplicity.