Oleg Yurchenko
Oleg Yurchenko has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Viktor Gurin
Institute of Electrodynamics of the NAS of Ukraine
10 shared publications - Volodymyr Pavlovskyi
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine
8 shared publications - I.S. Zubkov
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine
3 shared publications - Pavlo Herasymenko
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine
3 shared publications - V.Ya. Hutsaliuk
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine
3 shared publications - Volodymyr Yaskiv
Ternopil Ivan Puluj National Technical University
2 shared publications
Latest Publications
- Open Access
- 30 April 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (3) , 3-10
PROTECTION OF ELECTRICAL CONSUMERS AGAINST MICROSECOND HIGH-VOLTAGE SURGES UNDER PARTIAL LOAD OPERATION
The paper considers features of consumer protection against microsecond high-voltage surges from the power grid under consumer’s partial load operation. A typical protection circuit containing a cascade-connected voltage limiter and a two-stage LC low-pass filter (LPF) is analyzed. Theoretical calculations and simulation studies of the response of the L-shaped LPF to an input voltage surge under the partial load operation of the electrical consumer were carried out, which showed an increase in the response amplitude. To reduce the response of the LPF, it is proposed to introduce resistors in series with each capacitor of the LPF. The results of simulation and experimental verification confirmed the effectiveness of the proposed addition – the maximum voltage surge at the consumer’s AC input decreased by up to 2 times. References 17, figures 12.
- 30 April 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (3) , 3-10
Open AccessPROTECTION OF ELECTRICAL CONSUMERS AGAINST MICROSECOND HIGH-VOLTAGE SURGES UNDER PARTIAL LOAD OPERATION
The paper considers features of consumer protection against microsecond high-voltage surges from the power grid under consumer’s partial load operation. A typical protection circuit containing a cascade-connected voltage limiter and a two-stage LC low-pass filter (LPF) is analyzed. Theoretical calculations and simulation studies of the response of the L-shaped LPF to an input voltage surge under the partial load operation of the electrical consumer were carried out, which showed an increase in the response amplitude. To reduce the response of the LPF, it is proposed to introduce resistors in series with each capacitor of the LPF. The results of simulation and experimental verification confirmed the effectiveness of the proposed addition – the maximum voltage surge at the consumer’s AC input decreased by up to 2 times. References 17, figures 12.
- Open Access
- 4 September 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (5) , 38-44
INFLUENCE OF MAGNETIC COUPLING BETWEEN PARASITIC INDUCTIVITIES OF CAPACITORS OF DIFFERENT TYPES ON THE QUENCHMENT OF UNSYMMETRICAL INTERFERENCE INTRODUCED BY ANTI-INTERFERENCE FILTER
The influence of magnetic coupling between the parasitic inductances of Y capacitors of an RFI filter on the level of the filter insertion loss was studied. It is shown that the magnetic coupling mentioned above significantly worsens the attenuation introduced by the filter at frequencies from 150 kHz to 30 MHz. Mutually perpendicular, parallel, and end-to-end arrangement of capacitors relative to each other was analyzed as one of the methods of reducing the magnetic coupling between parasitic inductances of Y capacitors. It is shown that an increase in the distance between the said capacitors increases the attenuation introduced by the filter into common mode noise in the frequency range of 150 kHz to 30 MHz by 10 to 15 dB. References 27, Figures 9.
- 4 September 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (5) , 38-44
Open AccessINFLUENCE OF MAGNETIC COUPLING BETWEEN PARASITIC INDUCTIVITIES OF CAPACITORS OF DIFFERENT TYPES ON THE QUENCHMENT OF UNSYMMETRICAL INTERFERENCE INTRODUCED BY ANTI-INTERFERENCE FILTER
The influence of magnetic coupling between the parasitic inductances of Y capacitors of an RFI filter on the level of the filter insertion loss was studied. It is shown that the magnetic coupling mentioned above significantly worsens the attenuation introduced by the filter at frequencies from 150 kHz to 30 MHz. Mutually perpendicular, parallel, and end-to-end arrangement of capacitors relative to each other was analyzed as one of the methods of reducing the magnetic coupling between parasitic inductances of Y capacitors. It is shown that an increase in the distance between the said capacitors increases the attenuation introduced by the filter into common mode noise in the frequency range of 150 kHz to 30 MHz by 10 to 15 dB. References 27, Figures 9.
- 3 July 2025
- Published by Springer Nature
- p. 57-72
Multi-Frequency Transistor Converter for Enhanced Impedance Matching in Induction Heating Equipment
- 3 July 2025
- Published by Springer Nature
- p. 57-72
Multi-Frequency Transistor Converter for Enhanced Impedance Matching in Induction Heating Equipment
- Open Access
- 9 January 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (1) , 35-41
SYNCHRONOUS RECTIFIER IN DC VOLTAGE STABILIZER BASED ON HIGH-FREQUENCY MAGNETIC AMPLIFIERS
Requirements for semiconductor power converters with a high level of load current have been formulated. A review of research works addressing the problem of achieving maximum efficiency in DC voltage regulators using synchronous rectifiers based on modern field-effect transistors has been conducted. The proposed methods of synchronous rectification in pulse DC voltage stabilizers utilizing high-frequency magnetic amplifiers are described. These methods rely on the use of existing signals within the converter and eliminate the need for additional components or specialized drivers in their circuitry. The principle of operation is explained, and theoretical oscillograms are provided, which are validated by experimental data. Experimental results on the efficiency of such converters are presented. Specifically, the proposed methods of synchronous rectification in a pulse DC voltage stabilizer based on high-frequency magnetic amplifiers, with an output power of 300–400 W and input DC voltage of 310 V (equivalent to an industrial-frequency network), achieved an efficiency of 95%. References 21, figures 9.
- 9 January 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (1) , 35-41
Open AccessSYNCHRONOUS RECTIFIER IN DC VOLTAGE STABILIZER BASED ON HIGH-FREQUENCY MAGNETIC AMPLIFIERS
Requirements for semiconductor power converters with a high level of load current have been formulated. A review of research works addressing the problem of achieving maximum efficiency in DC voltage regulators using synchronous rectifiers based on modern field-effect transistors has been conducted. The proposed methods of synchronous rectification in pulse DC voltage stabilizers utilizing high-frequency magnetic amplifiers are described. These methods rely on the use of existing signals within the converter and eliminate the need for additional components or specialized drivers in their circuitry. The principle of operation is explained, and theoretical oscillograms are provided, which are validated by experimental data. Experimental results on the efficiency of such converters are presented. Specifically, the proposed methods of synchronous rectification in a pulse DC voltage stabilizer based on high-frequency magnetic amplifiers, with an output power of 300–400 W and input DC voltage of 310 V (equivalent to an industrial-frequency network), achieved an efficiency of 95%. References 21, figures 9.
- Open Access
- 21 October 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (6) , 15-20
A TRANSISTOR CONVERTER WITH LOAD IMPEDANCE MATCHING OF INDUCTION HEATING EQUIPMENT WITH TWO/THREE FREQUENCY OUTPUT CURRENT
This paper presents a schematic solution of a transistor converter for induction heating equipment featuring two/three-frequency output current. The proposed solution enables discrete adjustment of the input voltage of the inverter within the converter, facilitating alignment with the load impedance of the induction heating equipment through the sequential modulation of currents at different frequencies. Detailed descriptions of the operational modes of the DC/DC converter are provided, highlighting its unique characteristic of operating semiconductor elements in an almost static mode with minimal dynamic losses. This innovative approach not only enhances energy efficiency but also elevates electromagnetic compatibility in converters designed for induction heating equipment with two/three-frequency output currents. References 10, figures 4.
- 21 October 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (6) , 15-20
Open AccessA TRANSISTOR CONVERTER WITH LOAD IMPEDANCE MATCHING OF INDUCTION HEATING EQUIPMENT WITH TWO/THREE FREQUENCY OUTPUT CURRENT
This paper presents a schematic solution of a transistor converter for induction heating equipment featuring two/three-frequency output current. The proposed solution enables discrete adjustment of the input voltage of the inverter within the converter, facilitating alignment with the load impedance of the induction heating equipment through the sequential modulation of currents at different frequencies. Detailed descriptions of the operational modes of the DC/DC converter are provided, highlighting its unique characteristic of operating semiconductor elements in an almost static mode with minimal dynamic losses. This innovative approach not only enhances energy efficiency but also elevates electromagnetic compatibility in converters designed for induction heating equipment with two/three-frequency output currents. References 10, figures 4.
- 21 September 2024
- Published by Springer Nature
- p. 99-116
A Novel PDM Control Strategy for Voltage-Source Modular-Structured Resonant Converters
- 21 September 2024
- Published by Springer Nature
- p. 99-116
A Novel PDM Control Strategy for Voltage-Source Modular-Structured Resonant Converters
- Open Access
- 28 August 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2023 (65) , 121-126
RESEARCH OF A BIDIRECTIONAL VOLTAGE CONVERTER FOR APPLICATION IN ENERGY STORAGE SYSTEMS
Electromagnetic processes in a bidirectional DC converter with the possibility of increasing and decreasing output voltage levels using an asymmetric inverter for a battery energy storage system when operating in difficult conditions with a short conversion period and determining its parameters are considered. Bidirectional DC converters are widely used in hybrid energy storage systems and in DC distribution power systems. This non-isolated bidirectional boost-buck converter is designed to control the flow of energy between sources with different voltage levels due to the use of low-voltage batteries in these systems. Thanks to the ability of these converters to quickly redirect electrical energy both in one and the other direction, it became possible not only to charge the battery from stationary sources of electricity, but also to charge the battery during the operation of the generator from the internal combustion engine and regenerative braking. The results of calculations of the prototype of a bidirectional DC converter with a 14 V battery, a 200 V DC bus and an output power of 3500 W are given. A prototype was made to confirm the possibility of rapid energy conversion. Ref. 9, fig. 6. Keywords: electric power storage systems, bidirectional DC voltage converter, fast energy conversion, hybrid electric vehicle.
- 28 August 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2023 (65) , 121-126
Open AccessRESEARCH OF A BIDIRECTIONAL VOLTAGE CONVERTER FOR APPLICATION IN ENERGY STORAGE SYSTEMS
Electromagnetic processes in a bidirectional DC converter with the possibility of increasing and decreasing output voltage levels using an asymmetric inverter for a battery energy storage system when operating in difficult conditions with a short conversion period and determining its parameters are considered. Bidirectional DC converters are widely used in hybrid energy storage systems and in DC distribution power systems. This non-isolated bidirectional boost-buck converter is designed to control the flow of energy between sources with different voltage levels due to the use of low-voltage batteries in these systems. Thanks to the ability of these converters to quickly redirect electrical energy both in one and the other direction, it became possible not only to charge the battery from stationary sources of electricity, but also to charge the battery during the operation of the generator from the internal combustion engine and regenerative braking. The results of calculations of the prototype of a bidirectional DC converter with a 14 V battery, a 200 V DC bus and an output power of 3500 W are given. A prototype was made to confirm the possibility of rapid energy conversion. Ref. 9, fig. 6. Keywords: electric power storage systems, bidirectional DC voltage converter, fast energy conversion, hybrid electric vehicle.
- Open Access
- 15 June 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (4) , 37-42
ANALYSIS OF ELECTROMAGNETIC PROCESSES IN THE "VOLTAGE LIMITER - LOW-FREQUENCY FILTER" CIRCUIT DURING THE INFLUENCE OF HIGH-VOLTAGE SURGE FROM THE POWER SUPPLY NETWORK
In the work, a theoretical analysis of high-voltage surge (HVS) passing from a power supply network through the path "voltage limiter - low-pass filter" is carried out, with the aim to evaluate the effectiveness of the filter on reducing the amplitude of the residual HVS at the input of electrical and/or radio-electronic equipment. As a low-pass filter (LPF), an L-shaped filter was chosen. Typical means of limiting the amplitude of the HVS (gas-filled arresters, varistors, and suppressors) are analyzed, and their shortcomings are shown. The justification of the equivalent scheme for theoretical analysis is given. The analysis revealed a direct relationship between the cut-off frequency of the LPF, which is deter-mined by the nominal values of its elements, and the amplitude of the residual HVS at the mains input of the equipment, and also showed the effectiveness of inserting the LPF between the output of a typical HVS voltage limiter and the mains input of the mentioned equipment from the point of view of additional reduction of the residual HVS amplitude. References 18, figures 6.
- 15 June 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (4) , 37-42
Open AccessANALYSIS OF ELECTROMAGNETIC PROCESSES IN THE "VOLTAGE LIMITER - LOW-FREQUENCY FILTER" CIRCUIT DURING THE INFLUENCE OF HIGH-VOLTAGE SURGE FROM THE POWER SUPPLY NETWORK
In the work, a theoretical analysis of high-voltage surge (HVS) passing from a power supply network through the path "voltage limiter - low-pass filter" is carried out, with the aim to evaluate the effectiveness of the filter on reducing the amplitude of the residual HVS at the input of electrical and/or radio-electronic equipment. As a low-pass filter (LPF), an L-shaped filter was chosen. Typical means of limiting the amplitude of the HVS (gas-filled arresters, varistors, and suppressors) are analyzed, and their shortcomings are shown. The justification of the equivalent scheme for theoretical analysis is given. The analysis revealed a direct relationship between the cut-off frequency of the LPF, which is deter-mined by the nominal values of its elements, and the amplitude of the residual HVS at the mains input of the equipment, and also showed the effectiveness of inserting the LPF between the output of a typical HVS voltage limiter and the mains input of the mentioned equipment from the point of view of additional reduction of the residual HVS amplitude. References 18, figures 6.
- Open Access
- 18 August 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2022 (5) , 34-37
INCREASING OF ELECTRICAL AND RADIOELECTRONIC EQUIPMENT’S IMMUNITY AGAINST HIGH VOLTAGE SHORT-DURATION PULSE DISTURBANCES IN THE MAINS
A problem of electrical and radioelectronic equipment’s high energy pulse disturbance immunity is considered in the paper, in particular against microsecond high voltage disturbances (MHVD) in the power mains. It is showed causes of MHVD with amplitude up to 4 kV and even higher. A review of various protection methods against MHVD is carried out and it is shown that the use of a two-terminal network (TTN) with a significantly nonlinear current-voltage characteristic: varistors, suppressors and gas arrestors is the most effective. The report analyzes the operation principle of these two-poles and shows that the typical inclusion of such a device directly at the equipment’s input is not effective enough for cases where the high-frequency impedance of the mains is low. An L-circuit for connecting the TTN together with an LR link is proposed, and results of computer simulation with the aid of PSPICE showed that such a scheme reduces the MHVD amplitude on the network input of the equipment by 1.5 times comparing with the typical inclusion of such a device even under a low impedance of the mains Adding the low-pass filter to the L-circuit allows to reduce the MHVD amplitude by 40 and more times comparing with the typical inclusion of the TTN. References 8, figures 6.
- 18 August 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2022 (5) , 34-37
Open AccessINCREASING OF ELECTRICAL AND RADIOELECTRONIC EQUIPMENT’S IMMUNITY AGAINST HIGH VOLTAGE SHORT-DURATION PULSE DISTURBANCES IN THE MAINS
A problem of electrical and radioelectronic equipment’s high energy pulse disturbance immunity is considered in the paper, in particular against microsecond high voltage disturbances (MHVD) in the power mains. It is showed causes of MHVD with amplitude up to 4 kV and even higher. A review of various protection methods against MHVD is carried out and it is shown that the use of a two-terminal network (TTN) with a significantly nonlinear current-voltage characteristic: varistors, suppressors and gas arrestors is the most effective. The report analyzes the operation principle of these two-poles and shows that the typical inclusion of such a device directly at the equipment’s input is not effective enough for cases where the high-frequency impedance of the mains is low. An L-circuit for connecting the TTN together with an LR link is proposed, and results of computer simulation with the aid of PSPICE showed that such a scheme reduces the MHVD amplitude on the network input of the equipment by 1.5 times comparing with the typical inclusion of such a device even under a low impedance of the mains Adding the low-pass filter to the L-circuit allows to reduce the MHVD amplitude by 40 and more times comparing with the typical inclusion of the TTN. References 8, figures 6.