Claudia Barile
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Claudia Barile has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Pappalettera
Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70125 Bari, Italy
29 shared publications - Caterina Casavola
Department of Mechanics, Mathematics, and Management, Polytechnic University of Bari, 70126 Bari, Italy
27 shared publications - Vimalathithan Paramsamy Kannan
Politecnico di Bari
26 shared publications Caterina Casavola
Politecnico di Bari
17 shared publications- Carmine Pappalettere
Politecnico di Bari
14 shared publications Giovanni Pappalettera
7 shared publications
Latest Publications
- Open Access
- 27 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Evaluating failure modes in self-healing CFRPs via acoustic emission and a feature-informed neural network
- 27 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Open AccessEvaluating failure modes in self-healing CFRPs via acoustic emission and a feature-informed neural network
- Open Access
- 26 March 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 131 (1) , 8
Evaluating the Recovery of Mechanical Properties of Self-Healing Composites Using Destructive and Nondestructive Testing
The concept of self-healing polymers has been prevalent over the last few decades. However, their performance and behaviour in structural applications in the form of layered composites have not been studied extensively. In this study, an attempt has been made to evaluate the recovery of the mechanical properties of Carbon Fibre-Reinforced Polymer composites (CFRPs) with an intrinsically healable polymeric resin system. Destructive tests, including static tensile, compression, and flexural tests, are carried out to evaluate their ability to recover mechanical compliance after healing. Nondestructive tests based on the Acousto-Ultrasonic (AU) approach are carried out to establish and distinguish the state of these composites. The results show that the tested self-healing CFRPs can recover their mechanical properties, particularly their flexural and compressive properties, after unstable matrix damage. On the other hand, the AU approach, supported by Machine Learning (ML) models, demonstrates that the damaged states and the heal states of these composites can be distinguished from the virgin state.
- 26 March 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 131 (1) , 8
Open AccessEvaluating the Recovery of Mechanical Properties of Self-Healing Composites Using Destructive and Nondestructive Testing
The concept of self-healing polymers has been prevalent over the last few decades. However, their performance and behaviour in structural applications in the form of layered composites have not been studied extensively. In this study, an attempt has been made to evaluate the recovery of the mechanical properties of Carbon Fibre-Reinforced Polymer composites (CFRPs) with an intrinsically healable polymeric resin system. Destructive tests, including static tensile, compression, and flexural tests, are carried out to evaluate their ability to recover mechanical compliance after healing. Nondestructive tests based on the Acousto-Ultrasonic (AU) approach are carried out to establish and distinguish the state of these composites. The results show that the tested self-healing CFRPs can recover their mechanical properties, particularly their flexural and compressive properties, after unstable matrix damage. On the other hand, the AU approach, supported by Machine Learning (ML) models, demonstrates that the damaged states and the heal states of these composites can be distinguished from the virgin state.
- Open Access
- 30 January 2026
- Published by Elsevier in Measurement
- Vol. 268
Towards diagnostics of damage state in self-healing composites using an AI-driven acousto-ultrasonic approach
- 30 January 2026
- Published by Elsevier in Measurement
- Vol. 268
Open AccessTowards diagnostics of damage state in self-healing composites using an AI-driven acousto-ultrasonic approach
- 31 October 2025
- Published by Emerald Publishing in International Journal of Structural Integrity
- Vol. 17 (2) , 274-292
Development of a method for estimating the time-of-arrival of acoustic emission signals for structural health monitoring
Purpose: This study aims to develop a novel method for estimating the time-of-arrival (ToA) of acoustic emission (AE) signals generated by materials under loading. To use the estimated ToA to analyse damage evolution in the material. Design/methodology/approach: The ToA estimation method is developed based on the Akaike information criterion (AIC) with an addition of entropy in the maximum likelihood estimation. Carbon fibre reinforced polymer (CFRP) specimens in short beam shear (SBS) configuration are tested to generate the AE signal required for the study. The specimen is subjected to a three-point bending load and its damage evolution is analysed by the estimated ToA, peak amplitude and peak frequency of the AE signals. Findings: The proposed ToA estimation method works efficiently even for AE signals with a large number of reverberations. The damage evolution in the SBS specimen is mainly due to matrix cracking, delamination in the inner plies and interlaminar crack growth. AE signals with different levels of peak amplitude, peak frequency and varying ToAs are able to identify these different damage sources. Originality/value: The proposed ToA estimation method performs better than the traditional methods based on AIC. Its application can be extended to AE signals generated from large structures.
- 31 October 2025
- Published by Emerald Publishing in International Journal of Structural Integrity
- Vol. 17 (2) , 274-292
Development of a method for estimating the time-of-arrival of acoustic emission signals for structural health monitoring
Purpose: This study aims to develop a novel method for estimating the time-of-arrival (ToA) of acoustic emission (AE) signals generated by materials under loading. To use the estimated ToA to analyse damage evolution in the material. Design/methodology/approach: The ToA estimation method is developed based on the Akaike information criterion (AIC) with an addition of entropy in the maximum likelihood estimation. Carbon fibre reinforced polymer (CFRP) specimens in short beam shear (SBS) configuration are tested to generate the AE signal required for the study. The specimen is subjected to a three-point bending load and its damage evolution is analysed by the estimated ToA, peak amplitude and peak frequency of the AE signals. Findings: The proposed ToA estimation method works efficiently even for AE signals with a large number of reverberations. The damage evolution in the SBS specimen is mainly due to matrix cracking, delamination in the inner plies and interlaminar crack growth. AE signals with different levels of peak amplitude, peak frequency and varying ToAs are able to identify these different damage sources. Originality/value: The proposed ToA estimation method performs better than the traditional methods based on AIC. Its application can be extended to AE signals generated from large structures.
- Open Access
- 28 October 2025
- Published by Elsevier in Mechanics of Materials
- Vol. 212
Quantification of the influence of laser shock peening parameters on residual stresses in thick AA 7050 specimens: An experimental and explainable machine learning-based approach
- 28 October 2025
- Published by Elsevier in Mechanics of Materials
- Vol. 212
Open AccessQuantification of the influence of laser shock peening parameters on residual stresses in thick AA 7050 specimens: An experimental and explainable machine learning-based approach
- Open Access
- 30 September 2025
- Published by Elsevier in Applied Acoustics
- Vol. 242
Significance of statistical testing and data integration in acoustic emission analysis
- 30 September 2025
- Published by Elsevier in Applied Acoustics
- Vol. 242
Open AccessSignificance of statistical testing and data integration in acoustic emission analysis
- 21 August 2025
- Published by Elsevier in Composites Communications
- Vol. 59
An acoustic emission-based characterisation of intrinsically healing fibre-reinforced polymer composites
- 21 August 2025
- Published by Elsevier in Composites Communications
- Vol. 59
An acoustic emission-based characterisation of intrinsically healing fibre-reinforced polymer composites
- Open Access
- 19 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 85 (1) , 23
Characterisation of Novel Self-Healing Composites Using Acousto-Ultrasonic Testing
Self-healing composites are designed based on natural healing processes such as bone regeneration and blood coagulation. These composites have polymeric material containing covalent adaptable networks that rearrange their molecular structure when heated, thereby serving as a healing agent. The inclusion of the healing polymers into the principal matrix of the fiber-reinforced composites alters their off-axis properties. In addition, the healing agents tend to bleed out of the composite structures upon heating. It is, therefore, essential to characterize the extent of the changes in the off-axis properties of the self-healing composites. In this research work, three different configurations of self-healing composites are subjected to three-point bending tests, and their healing characteristics are studied using Acousto-Ultrasonic tests. Frequencies of the propagating stress waves in the AU tests are used to analyze the different conditions of the self-healing composites, such as virgin, damaged, damaged-partially healed, and damaged-fully healed. The results show that the AU test could potentially be used to evaluate the healing behavior of these fiber-reinforced self-healable composites.
- 19 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 85 (1) , 23
Open AccessCharacterisation of Novel Self-Healing Composites Using Acousto-Ultrasonic Testing
Self-healing composites are designed based on natural healing processes such as bone regeneration and blood coagulation. These composites have polymeric material containing covalent adaptable networks that rearrange their molecular structure when heated, thereby serving as a healing agent. The inclusion of the healing polymers into the principal matrix of the fiber-reinforced composites alters their off-axis properties. In addition, the healing agents tend to bleed out of the composite structures upon heating. It is, therefore, essential to characterize the extent of the changes in the off-axis properties of the self-healing composites. In this research work, three different configurations of self-healing composites are subjected to three-point bending tests, and their healing characteristics are studied using Acousto-Ultrasonic tests. Frequencies of the propagating stress waves in the AU tests are used to analyze the different conditions of the self-healing composites, such as virgin, damaged, damaged-partially healed, and damaged-fully healed. The results show that the AU test could potentially be used to evaluate the healing behavior of these fiber-reinforced self-healable composites.
- Open Access
- 18 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 85 (1) , 16
Study of Damage and Microplastic Release in Clear Aligners Under Cyclic Loads
In this research work, the mechanical performance of a thermoformed clear dental aligner is studied. Its performance is evaluated under the cyclic compression test, which is designed to simulate the occlusal forces applied on the aligner during swallowing operations for its entire usage period. The mechanical results show that the aligner exhibit stable energy absorption and stiffness behaviour throughout its use period and thus can potentially be used for clinical applications. The microplastic released from the aligner due to the fatigue-like damage is analysed using optical microscopy. Most of the microplastics released have larger dimensions, which may be excreted from the gastrointestinal tracts and have less possibility to pass through the epithelium passively. Therefore, the use of aligner may not pose any cytotoxic health risks.
- 18 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 85 (1) , 16
Open AccessStudy of Damage and Microplastic Release in Clear Aligners Under Cyclic Loads
In this research work, the mechanical performance of a thermoformed clear dental aligner is studied. Its performance is evaluated under the cyclic compression test, which is designed to simulate the occlusal forces applied on the aligner during swallowing operations for its entire usage period. The mechanical results show that the aligner exhibit stable energy absorption and stiffness behaviour throughout its use period and thus can potentially be used for clinical applications. The microplastic released from the aligner due to the fatigue-like damage is analysed using optical microscopy. Most of the microplastics released have larger dimensions, which may be excreted from the gastrointestinal tracts and have less possibility to pass through the epithelium passively. Therefore, the use of aligner may not pose any cytotoxic health risks.
- Top Cited PapersOpen Access
- 5 February 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (2) , e0318207
Experimental assessment of damage and microplastic release during cyclic loading of clear aligners
The widespread adoption of clear aligners in orthodontic treatments in recent years has necessitated a more precise examination of the mechanical properties of the devices currently available in orthodontics. Recent studies indicate that aligners, when exposed to the forces exerted during swallowing, undergo fatigue-like phenomena, leading to chip formation and cracks. The cumulative damage results in a compromised fit between the tooth and aligner, which is crucial for the effective execution of orthodontic treatment. Additionally, the formation of chips poses a potential risk to patients, as there is a possibility of inadvertently ingesting microplastics that become detached from the aligner over time. This study attempts to assess the release of microplastics from the aligners subjected to cyclic compressive loading. Three different aligners (Essix Ace, Ghost Aligner and Invisalign) are tested to simulate swallowing conditions over the aligner usage period. The mechanical performance is studied in terms of the energy absorbed by the aligner, which shows that the Essix Ace has a stable energy absorption behaviour, while the energy absorbed by the Invisalign is significantly higher than their counterparts. Ghost Aligner did not perform well in the cyclic compression tests. The microplastics (MPs) released by the aligners are examined under an optical microscope. A dimensional analysis based on k-means image segmentation and edge detection algorithm is developed to analyse the MPs. The dimensional analysis of the MPs revealed that the ingestion of the MPs released by all the three aligners does not pose a health risk.
- 5 February 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (2) , e0318207
Top Cited PapersOpen AccessExperimental assessment of damage and microplastic release during cyclic loading of clear aligners
The widespread adoption of clear aligners in orthodontic treatments in recent years has necessitated a more precise examination of the mechanical properties of the devices currently available in orthodontics. Recent studies indicate that aligners, when exposed to the forces exerted during swallowing, undergo fatigue-like phenomena, leading to chip formation and cracks. The cumulative damage results in a compromised fit between the tooth and aligner, which is crucial for the effective execution of orthodontic treatment. Additionally, the formation of chips poses a potential risk to patients, as there is a possibility of inadvertently ingesting microplastics that become detached from the aligner over time. This study attempts to assess the release of microplastics from the aligners subjected to cyclic compressive loading. Three different aligners (Essix Ace, Ghost Aligner and Invisalign) are tested to simulate swallowing conditions over the aligner usage period. The mechanical performance is studied in terms of the energy absorbed by the aligner, which shows that the Essix Ace has a stable energy absorption behaviour, while the energy absorbed by the Invisalign is significantly higher than their counterparts. Ghost Aligner did not perform well in the cyclic compression tests. The microplastics (MPs) released by the aligners are examined under an optical microscope. A dimensional analysis based on k-means image segmentation and edge detection algorithm is developed to analyse the MPs. The dimensional analysis of the MPs revealed that the ingestion of the MPs released by all the three aligners does not pose a health risk.