JCJorge S. Carlos

Jorge S. Carlos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jorge S. Carlos has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Window assessment at different level height on a Portuguese typical street canyon

    by Jorge S. Carlos

    This paper presents the results of a study investigating the ventilation mode, the solar heat gain and daylight performance via vertical fenestration on a street canyon. In recent years there has been a growing awareness in energy-efficient building design and operation of the building stock. Dynamic envelope/window systems have potential to optimize the performance of the building, between airing, solar heat gain and daylight admission. However, higher thermal resistance glazing implies a reduction of solar transmittance. A typical street canyon in Portugal was used for the present study. Three different room ratios and two types of windows at two different floors were used for comparison. Different simulation tools were used during this study. To be comparable with other studies several ratios were present, as the window/wall, the glazing/wall ratios, the window/floor and the glazing/floor ratios as well as the window opening area. This paper presents the obtained airflow and solar gains on both heating and cooling season in addition to the level of daylight factor. It was found that specific adaptive actions to improve indoor environmental quality and reduce the need of energy consumption are needed.

  • Open Access

    OPTIMAL WINDOW GEOMETRY FACTORS FOR ELEMENTARY SCHOOL BUILDINGS IN PORTUGAL

    by Jorge S. Carlos

    INTRODUCTION: With respect to thermal performance, windows are the weakest component of the building envelope, essentially because the U-value is usually higher than the opaque envelope. This would allow the highest heat conductance of the building envelope. However, it also helps buildings to gain useful solar heat during winter. Therefore, it has been generally accepted that passive buildings would have small windows towards the poles and large windows facing the equator (Persson, Roos, and Wall 2006). In spite of this guideline, large or fully glazed facades have been used in modern architecture. The intensive use of air conditioning is the result of overheating and high thermal loss problems, which otherwise would lead to thermal discomfort. This extensive use of large windows associated with high energy consumption has motivated researchers to study this building component. Window areas were investigated by Persson et al. (Persson, Roos, and Wall 2006) on 20 terraced houses with larger windows facing the equator and built in Gothenburg. The building envelope was well insulated and fitted with energy efficient windows. It was found that energy efficient windows do not have a major influence on the heating demand in the winter, but it is relevant for the cooling need in summer. Therefore, reduced indoor illuminance due to small windows can be solved by enlarging them in order to obtain relevant daylighting conditions. When efficient windows are designed for a warm climate, as in Mexico, reducing heat flux and solar transmittance indoors was the best option for energy savings (Aguilar et al. 2017). However, reducing solar transmittance influences the indoor illuminance, which was not analyzed.


  • Open Access

    Essence of Daylight in the Cistercian Monastic Church of S. Bento de Cástris, Évora, Portugal

    by Ana M. T. Martins, Jorge S. Carlos

    Natural light in the Cistercian churches is closely linked not only with the liturgical requirements at the "officium" but also with the canonical hours based on the "ora et labora" dictated by the Rule of St. Benedict. The Cistercian architecture, in its beginnings (12th century forward) is characterized by austerity, simplicity and the play of light and shadow that gives value to the monastic architectural space itself, making it perfect for a contemplative experience. In the Cistercian Monastery the church is the central piece of the monastic building. Nave, transept and apse are the main architectural components to which is added the choir. This paper contextualizes the importance and close connections of natural light, within the Cistercian Monasteries architecture. Thus the essence of daylight is analysed within the Church of the Monastery of S. Bento de Cástris, in Évora, Portugal. This former Monastery (13th - 19th centuries) includes the church, at the south-eastern corner which has not only a high choir, but also a low lateral choir (within the presbytery). Its unchanged exterior walls are made of solid masonry. Although the function of the walls is primarily structural, the windows allow the daylight to penetrate the space of the church. The church has two external façades facing northeast and southeast. The combined orientation effect of the church's main axis and the sun trajectory determines how the sunlight reaches the interior of this architectural structure. This study presents the qualitative and quantitative analysis of the luminous environment in the church of S. Bento de Cástris, being the first based on the authors' perception of the effect of the daylight within the different areas of the enclosed space. The appreciation of the spatial experiences was supported by quantitative daylight simulations that were conducted in selected areas within the space. With this paper is intended to contribute to the debate about the specificity of daylight, in the context of Cistercian architecture.


  • Open Access

    Assessing Thermal Comfort Due to a Ventilated Double Window

    by Jorge S. Carlos, Helena Corvacho

    Building design and its components are the result of a complex process, which should provide pleasant conditions to its inhabitants. Therefore, indoor acceptable comfort is influenced by the architectural design. ISO and ASHRAE standards define thermal comfort as the condition of mind that expresses satisfaction with the thermal environment. The energy demand for heating, beside the building's physical properties, also depend on human behaviour, like opening or closing windows. Generally, windows are the weakest façade element concerning to thermal performance. A lower thermal resistance allows higher thermal conduction through it. When a window is very hot or cold, and the occupant is very close to it, it may result in thermal discomfort. The functionality of a ventilated double window introduces new physical considerations to a traditional window. In consequence, it is necessary to study the local effect on human comfort in function of the boundary conditions. Wind, solar availability, air temperature and therefore heating and indoor air quality conditions will affect the relationship between this passive system and the indoor environment. In the present paper, the influence of thermal performance and ventilation on human comfort resulting from the construction and geometry solutions is shown, helping to choose the best solution. The presented approach shows that in order to save energy it is possible to reduce the air changes of a room to the minimum, without compromising air quality, enhancing simultaneously local thermal performance and comfort. The results of the study on the effect of two parallel windows with a ventilated channel in the same fenestration on comfort conditions for several different room dimensions, are also presented. As the room dimensions' rate changes so does the window to floor rate; therefore, under the same climatic conditions and same construction solution, different results are obtained.


  • BUILT HERITAGE RESEARCH AND EDUCATION

    by Ana M.T. Martins, Jorge S. Carlos, Miguel C.S. Nepomuceno

    Information about the paper titled "BUILT HERITAGE RESEARCH AND EDUCATION" at IATED Digital Library


  • The impact of refurbished windows on Portuguese old school buildings

    by Jorge S. Carlos

    This paper presents results of a study investigating ventilation mode, solar heat gain and daylight performance via vertical fenestration of a common school building in Portugal. In recent years, there has been a growing awareness in energy-efficient building design and operation of the building stock. The windows are usually the first component to be replaced by new and more efficient ones. Dynamic envelope/window systems may optimize the performance of the building when taking into account airing, solar heat gain rejection/acceptance and daylight admission. Higher thermal resistance glazing implies a reduction of solar transmittance. A typical school building located in Covilhã, Portugal was used for the study. Three different conventional windows were used for comparison: a single pane as found in the building, a double-pane to increase the thermal resistance and a double-pane with daylighting controls. Different simulation tools were used during this study. To be comparable with other studies, several ratios were present, namely the window/wall, the glazing/wall ratios, the window/floor and the glazing/floor ratios as well as the window opening area. This paper presents the obtained airflow and solar gains on both the heating and cooling season as well as the level of daylight for both overcast and non-overcast skies. The findings are essential for the assessment of passive building energy-saving techniques on a hypothetical building refurbishment by replacing old windows. However, specific adaptive actions to improve indoor environmental quality are also needed.


  • Sustainability assessment of government school buildings in Portugal

    by Jorge S. Carlos

    An accepted design feature of passive buildings in the northern hemisphere has been to have small windows facing north and large windows facing the equator, in order to minimize losses on the north side while gaining solar heat on the south. Solar gains and daylight are key passive strategies to improve energy performance without incurring additional construction and operational costs. The purpose of this research was to investigate how sustainable traditional government school buildings that can be found all over Portugal are in terms of more efficient use of energy and materials through design solutions. The selected case study is a typical vernacular located in Covilhã with cold winter and hot summer climate. The findings demonstrated that solar gains reduced the heating load in winter; however, the internal daylight level in the building was insufficient.


  • The impact of thermal mass on cold and hot climate zones of Portugal

    by Jorge S. Carlos

    The aim of this paper is focused on the energy performance of buildings containing massive wall alternatives. The analysis comprised the comparison of the heating and cooling loads of seven characteristic wall configurations of one sample building with different dynamic internal heat capacity (ISO 13790:2008) in spite of the equal thermal resistance. The equal thermal resistance, as derived from simple steady-state condition, was imposed in order to allow research of effects solely attributed to the wall heat capacity on the building performance. A detached one floor dwelling exposed to different climate conditions in Portugal was analysed to illustrate the effect of the same wall in terms of energy demand during cold and hot weather conditions. A whole building dynamic modelling using EnergyPlus was employed for the energy analysis. The best thermal performance was obtained with massive walls that were located at the inner side, for a very heavy weight building and high building time constant.