Paul Raftery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paul Raftery has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Stefano Schiavon
University of California, Berkeley, Berkeley, California, USA
5 shared publications Fred Bauman
4 shared publications- Carlos Duarte Roa
Center for the Built Environment, UC Berkeley
3 shared publications - Aoyu Zou2 shared publications
- Arpad Horvath
Department of Civil and Environmental Engineering, University of California, Berkeley, CA 94720, United States of America
2 shared publications - Caroline Karmann
Architecture and Intelligent Living, KIT, Germany
2 shared publications
Latest Publications
- Open Access
- 10 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Ten questions concerning air movement as a primary cooling strategy: “Fan-first” cooling
- 10 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Open AccessTen questions concerning air movement as a primary cooling strategy: “Fan-first” cooling
- Open Access
- 18 August 2026
- Published by Elsevier in SSRN Electronic Journal
Evaluating load shifting controls in 23 heat pump water heaters in multi-family residences
Residential water heating accounts for nearly 20% of household energy use, making it a critical resource for demand flexibility as electricity grids decarbonize and incorporate higher shares of variable renewable generation. Heat pump water heaters (HPWHs) offer high efficiency and inherent thermal storage, enabling load shifting away from peak utility rate and high-emission periods. However, large-scale long-term field evidence of their real-world performance and reliable methods to quantify their load-shifting impacts remain limited. This study evaluated the load-shifting potential of a model predictive control (MPC) intervention across 23 residential units in two locations in California. The MPC strategy jointly optimizes time-of-use electricity costs, marginal greenhouse-gas emissions, and water temperature satisfaction as an intervention, and is compared against a fixed setpoint baseline using a randomized switchback experimental design. Over a nine-month monitoring period, we measured HPWH energy use at both the device submeter and utility-meter levels. The ratio of electrical input to hot water heat output energy was a mean of 2.3 across all 23 units, well below the rated Uniform Efficiency Factor reported in laboratory test conditions (3.85 or 4 for the models involved). As a result, the intervention slightly increased daily water-heating energy, but we observed a detectable reduction in electricity consumption during the peak time-of-use window (4 – 9 p.m.). Occupant satisfaction with hot water service largely remained unchanged. However, at the aggregated population level, differences in utility-metered energy use and GHG emissions reduction were not statistically significant. Overall, the results highlight both the potential and limitations of HPWH load shifting in multifamily buildings, while demonstrating the value of randomized experimental designs for evaluating residential grid-flexibility technologies. By randomly switching between baseline and intervention operation, the approach shortens the evaluation timeline from the 24 months typically required by conventional pre/post comparisons to 9 months. It also reduces the need for extensive weather and hot-water draw normalization, while providing more robust uncertainty quantification that can increase utility confidence when deciding whether to scale a pilot into a full program.
- 18 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEvaluating load shifting controls in 23 heat pump water heaters in multi-family residences
Residential water heating accounts for nearly 20% of household energy use, making it a critical resource for demand flexibility as electricity grids decarbonize and incorporate higher shares of variable renewable generation. Heat pump water heaters (HPWHs) offer high efficiency and inherent thermal storage, enabling load shifting away from peak utility rate and high-emission periods. However, large-scale long-term field evidence of their real-world performance and reliable methods to quantify their load-shifting impacts remain limited. This study evaluated the load-shifting potential of a model predictive control (MPC) intervention across 23 residential units in two locations in California. The MPC strategy jointly optimizes time-of-use electricity costs, marginal greenhouse-gas emissions, and water temperature satisfaction as an intervention, and is compared against a fixed setpoint baseline using a randomized switchback experimental design. Over a nine-month monitoring period, we measured HPWH energy use at both the device submeter and utility-meter levels. The ratio of electrical input to hot water heat output energy was a mean of 2.3 across all 23 units, well below the rated Uniform Efficiency Factor reported in laboratory test conditions (3.85 or 4 for the models involved). As a result, the intervention slightly increased daily water-heating energy, but we observed a detectable reduction in electricity consumption during the peak time-of-use window (4 – 9 p.m.). Occupant satisfaction with hot water service largely remained unchanged. However, at the aggregated population level, differences in utility-metered energy use and GHG emissions reduction were not statistically significant. Overall, the results highlight both the potential and limitations of HPWH load shifting in multifamily buildings, while demonstrating the value of randomized experimental designs for evaluating residential grid-flexibility technologies. By randomly switching between baseline and intervention operation, the approach shortens the evaluation timeline from the 24 months typically required by conventional pre/post comparisons to 9 months. It also reduces the need for extensive weather and hot-water draw normalization, while providing more robust uncertainty quantification that can increase utility confidence when deciding whether to scale a pilot into a full program.
- Open Access
- 15 April 2026
- Published by Taylor & Francis in Journal of Building Performance Simulation
- p. 1-25
Room surface convective heat transfer with ceiling fans and its effect on radiant cooling systems
1. Radiant heating and cooling systems are increasingly adopted as a strategy to reduce building energy use and greenhouse gas emissions compared to conventional all-air systems (Rhee and Kim 2015)...
- 15 April 2026
- Published by Taylor & Francis in Journal of Building Performance Simulation
- p. 1-25
Open AccessRoom surface convective heat transfer with ceiling fans and its effect on radiant cooling systems
1. Radiant heating and cooling systems are increasingly adopted as a strategy to reduce building energy use and greenhouse gas emissions compared to conventional all-air systems (Rhee and Kim 2015)...
- Open Access
- 6 April 2025
- Published by Elsevier in Energy and Buildings
- Vol. 338
Simulation-Based evaluation of Cost-Responsive supply air temperature control strategy for office buildings across different climates
- 6 April 2025
- Published by Elsevier in Energy and Buildings
- Vol. 338
Open AccessSimulation-Based evaluation of Cost-Responsive supply air temperature control strategy for office buildings across different climates
- Open Access
- 5 March 2025
- Published by Elsevier in Building and Environment
- Vol. 275
Embodied carbon in mechanical, electrical, and plumbing systems: A critical literature review
- 5 March 2025
- Published by Elsevier in Building and Environment
- Vol. 275
Open AccessEmbodied carbon in mechanical, electrical, and plumbing systems: A critical literature review
- Open Access
- 30 January 2025
- Published by Elsevier in Energy and Buildings
- Vol. 331
How high can You Go: Determining the warmest supply water temperature for high thermal mass radiant cooling systems under thermal comfort constraints
- 30 January 2025
- Published by Elsevier in Energy and Buildings
- Vol. 331
Open AccessHow high can You Go: Determining the warmest supply water temperature for high thermal mass radiant cooling systems under thermal comfort constraints
- Open Access
- 22 October 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 98
Reliably estimating the impact of an active control strategy in a building
- 22 October 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 98
Open AccessReliably estimating the impact of an active control strategy in a building
- Open Access
- 11 March 2024
- Published by Elsevier in Building and Environment
- Vol. 254
Considerations for estimating operational greenhouse gas emissions in whole building life-cycle assessments
- 11 March 2024
- Published by Elsevier in Building and Environment
- Vol. 254
Open AccessConsiderations for estimating operational greenhouse gas emissions in whole building life-cycle assessments
- Open Access
- 6 November 2023
- Published by IOP Publishing in Environmental Research: Infrastructure and Sustainability
- Vol. 3 (4) , 043001
A perspective on tools for assessing the building sector’s greenhouse gas emissions and beyond
Increasing impacts from anthropogenic climate change, coupled with the rising need to provide safe and healthy buildings in which people can live, work, and play, necessitates methods and tools for decarbonizing the building sector. Governments, industry, and others are interested in assessing both the embodied and operational greenhouse gas (GHG) emissions of buildings. Stakeholders have embraced whole building life-cycle assessment (WBLCA) as a framework for quantifying the life-cycle impacts of buildings, from raw material extraction to the building’s end of life. The purpose of this perspective is to offer an analysis on prominently used WBLCA tools, focusing on how well the tools are suited for assessing the embodied and operational GHG emissions from all phases of a building’s life cycle, and to suggest recommendations for improving the tools. Existing WBLCA tools can provide a detailed assessment of most materials used in the building’s core and shell but lack the capability to quantify impacts accurately and comprehensively from all building systems as well as from the construction, transportation, operation, and end-of-life phases. Suggested short term improvements for the tools include: (1) increased standardization among tools and environmental product declarations (EPDs) to allow for detailed comparison among different material options earlier in the design process; (2) incorporation of verified, local-manufacturer EPDs for all building materials, components, and systems and of specific on-site conditions; and (3) integration of tradeoffs between embodied and operational design decisions. We need to move beyond the prevailing approach of using WBLCA tools to select building materials that have the lowest embodied footprint. Future WBLCA tools need to be able to assess, in detail, how different design, construction, transportation, operation, and end-of-life decisions for a building not only affect GHG emissions, but other key sustainability goals including resilience to climate change, environmental justice, and human health of local communities.
- 6 November 2023
- Published by IOP Publishing in Environmental Research: Infrastructure and Sustainability
- Vol. 3 (4) , 043001
Open AccessA perspective on tools for assessing the building sector’s greenhouse gas emissions and beyond
Increasing impacts from anthropogenic climate change, coupled with the rising need to provide safe and healthy buildings in which people can live, work, and play, necessitates methods and tools for decarbonizing the building sector. Governments, industry, and others are interested in assessing both the embodied and operational greenhouse gas (GHG) emissions of buildings. Stakeholders have embraced whole building life-cycle assessment (WBLCA) as a framework for quantifying the life-cycle impacts of buildings, from raw material extraction to the building’s end of life. The purpose of this perspective is to offer an analysis on prominently used WBLCA tools, focusing on how well the tools are suited for assessing the embodied and operational GHG emissions from all phases of a building’s life cycle, and to suggest recommendations for improving the tools. Existing WBLCA tools can provide a detailed assessment of most materials used in the building’s core and shell but lack the capability to quantify impacts accurately and comprehensively from all building systems as well as from the construction, transportation, operation, and end-of-life phases. Suggested short term improvements for the tools include: (1) increased standardization among tools and environmental product declarations (EPDs) to allow for detailed comparison among different material options earlier in the design process; (2) incorporation of verified, local-manufacturer EPDs for all building materials, components, and systems and of specific on-site conditions; and (3) integration of tradeoffs between embodied and operational design decisions. We need to move beyond the prevailing approach of using WBLCA tools to select building materials that have the lowest embodied footprint. Future WBLCA tools need to be able to assess, in detail, how different design, construction, transportation, operation, and end-of-life decisions for a building not only affect GHG emissions, but other key sustainability goals including resilience to climate change, environmental justice, and human health of local communities.
- Open Access
- 3 March 2023
- Published by Elsevier in Applied Energy
- Vol. 337
A laboratory test of an Offline-trained Multi-Agent Reinforcement Learning Algorithm for Heating Systems
- 3 March 2023
- Published by Elsevier in Applied Energy
- Vol. 337
Open AccessA laboratory test of an Offline-trained Multi-Agent Reinforcement Learning Algorithm for Heating Systems