Yuqiang Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuqiang Deng has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Jing Yu
4 shared publicationsQing Sun
National Institute of Metrology, Beijing 100029, China
4 shared publicationsZhigang Zhang
3 shared publicationsChing-Yue Wang
2 shared publicationsChun Zhou
2 shared publicationsJun Tao
2 shared publications
Latest Publications
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 13 (4) , 347-353
Room Temperature Absolute Radiometer for Reproduction of Terahertz Radiant Power
We propose an electrical substitution and laser calibration technique for reproduction of terahertz radiant power. With this technique, the equivalence of terahertz absorption and electrical heating in the absorber is corrected and accurate terahertz radiant power is reproduced. A two-cavity absolute radiometer was developed for accurate reproduction of terahertz radiant power working at room temperature. The absolute radiometer has two absorptive cavities coated with different coatings. One cavity was coated with 3M Velvet-coating and used for the absolute reproduction of laser radiant power, and the other was coated with a mixture of silicon carbide particles and 3M Velvet-coating and used for the reproduction of terahertz radiant power. With the comparison of the two cavities under stable laser irradiance, the equivalence between terahertz absorption and electrical heating is calibrated, and the precision of absolute reproduction for terahertz power is improved. The reproduced power using this absolute radiometer agreed excellently with the terahertz power standard at the National Institute of Metrology, which had been used in the first international terahertz power comparison.
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 13 (4) , 347-353
Room Temperature Absolute Radiometer for Reproduction of Terahertz Radiant Power
We propose an electrical substitution and laser calibration technique for reproduction of terahertz radiant power. With this technique, the equivalence of terahertz absorption and electrical heating in the absorber is corrected and accurate terahertz radiant power is reproduced. A two-cavity absolute radiometer was developed for accurate reproduction of terahertz radiant power working at room temperature. The absolute radiometer has two absorptive cavities coated with different coatings. One cavity was coated with 3M Velvet-coating and used for the absolute reproduction of laser radiant power, and the other was coated with a mixture of silicon carbide particles and 3M Velvet-coating and used for the reproduction of terahertz radiant power. With the comparison of the two cavities under stable laser irradiance, the equivalence between terahertz absorption and electrical heating is calibrated, and the precision of absolute reproduction for terahertz power is improved. The reproduced power using this absolute radiometer agreed excellently with the terahertz power standard at the National Institute of Metrology, which had been used in the first international terahertz power comparison.
- 1 January 2020
- Published by Journal of Applied Optics in Journal of Applied Optics
- Vol. 41 (4) , 651-661
Progress of terahertz metrology research and standard construction
Terahertz, as a novel technology, has been widely used in the field of material component recognition, high-speed communication, biomedicine, security imaging and military defense. Various applications of terahertz technology are based on the measurement of terahertz itself and its interaction with substances, therefore the accurate terahertz parameter measurement and relevant magnitude tracing are the technical support and guarantee of terahertz application. The measurement technology and tracing method, developed measuring instruments and devices, and established metrology calibration regulations, and metrology standard device formed in the terahertz radiation parameters metrology standard research by National Institute of Metrology were introduced. The magnitude tracing transitive graphs of terahertz radiation time domain, frequency domain, space domain and intensity were presented, and the measurement uncertainty analysis was carried out. The proposed terahertz metrology method and standard devices can guarantee the reliable magnitude in terahertz technology research and application, and can also provide a reference for other terahertz parameters measurement.
- 1 January 2020
- Published by Journal of Applied Optics in Journal of Applied Optics
- Vol. 41 (4) , 651-661
Progress of terahertz metrology research and standard construction
Terahertz, as a novel technology, has been widely used in the field of material component recognition, high-speed communication, biomedicine, security imaging and military defense. Various applications of terahertz technology are based on the measurement of terahertz itself and its interaction with substances, therefore the accurate terahertz parameter measurement and relevant magnitude tracing are the technical support and guarantee of terahertz application. The measurement technology and tracing method, developed measuring instruments and devices, and established metrology calibration regulations, and metrology standard device formed in the terahertz radiation parameters metrology standard research by National Institute of Metrology were introduced. The magnitude tracing transitive graphs of terahertz radiation time domain, frequency domain, space domain and intensity were presented, and the measurement uncertainty analysis was carried out. The proposed terahertz metrology method and standard devices can guarantee the reliable magnitude in terahertz technology research and application, and can also provide a reference for other terahertz parameters measurement.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 9 (6) , 637-642
THz Broadband Absorber Fabricated by EHD Printing Technology With High Error Tolerance
Terahertz(THz) devices, including the THz broadband absorbers, have attracted much attention in the recent decade. However, due to the micron-level precision requirement, the mainstream fabrication technology for terahertz devices still rely on complex and expensive photo-lithography or nano-imprinting techniques. Electrohydrodynamics(EHD)-printing technology offers a novel, convenient and cost-effective solution to this issue. A broadband terahertz absorber with over 90% absorption in the range of (98-353) GHz was designed and fabricated by EHD-printing technology, and the inductive fishnet grid structure was used for the meta-surface. The equivalent circuit model of the absorber was established based on the transmission line theory and impedance matching theory. Simulation results matched well with the theoretical and experimental results, and further demonstrated that the absorbers were polarization-insensitive. Furthermore, both simulation and experiments proved that the absorption spectrum was insensitive to the fishnet grid linewidth and surface resistance, i.e., the design has high tolerance to possible fabrication errors. Therefore, the EHD-printing technology can be a promising fabrication method of THz absorbers for future mass production.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 9 (6) , 637-642
THz Broadband Absorber Fabricated by EHD Printing Technology With High Error Tolerance
Terahertz(THz) devices, including the THz broadband absorbers, have attracted much attention in the recent decade. However, due to the micron-level precision requirement, the mainstream fabrication technology for terahertz devices still rely on complex and expensive photo-lithography or nano-imprinting techniques. Electrohydrodynamics(EHD)-printing technology offers a novel, convenient and cost-effective solution to this issue. A broadband terahertz absorber with over 90% absorption in the range of (98-353) GHz was designed and fabricated by EHD-printing technology, and the inductive fishnet grid structure was used for the meta-surface. The equivalent circuit model of the absorber was established based on the transmission line theory and impedance matching theory. Simulation results matched well with the theoretical and experimental results, and further demonstrated that the absorbers were polarization-insensitive. Furthermore, both simulation and experiments proved that the absorption spectrum was insensitive to the fishnet grid linewidth and surface resistance, i.e., the design has high tolerance to possible fabrication errors. Therefore, the EHD-printing technology can be a promising fabrication method of THz absorbers for future mass production.
- 22 May 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (6) , 648-656
A Single-Resonant-Structure and Optically Transparent Broadband THz Metamaterial Absorber
- 22 May 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (6) , 648-656
A Single-Resonant-Structure and Optically Transparent Broadband THz Metamaterial Absorber
- 13 February 2017
- Published by IOP Publishing in Applied Physics Express
- Vol. 10 (3) , 037302
Multimode acoustic transparency and slow sound effects in hybrid subwavelength resonators
- 13 February 2017
- Published by IOP Publishing in Applied Physics Express
- Vol. 10 (3) , 037302
Multimode acoustic transparency and slow sound effects in hybrid subwavelength resonators
- 26 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (4) , 1-6
Traceable Measurements of CW and Pulse Terahertz Power With Terahertz Radiometer
We report on traceable measurements of continues wave (CW) and pulse terahertz (THz) power with a THz radiometer. A sensitive THz radiometer with a broad bandwidth, high absorbance coating as absorber was fabricated. The absorber has an absorbance of higher than 99% in both 0.1 THz-3.0 THz region and in visible laser wavelengths range, which allows for an absolute measurement of THz radiation power and traceability to the International System of Units (SI). The uncertainty budget of CW THz power measurement with this radiometer is discussed, and the measurement results agreed excellently in the first international THz power comparison. Due to its high sensitivity and flat spectral responsivity, a pulse THz radiation from a THz time-domain spectrometer (THz-TDS) was absolutely measured with this radiometer.
- 26 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (4) , 1-6
Traceable Measurements of CW and Pulse Terahertz Power With Terahertz Radiometer
We report on traceable measurements of continues wave (CW) and pulse terahertz (THz) power with a THz radiometer. A sensitive THz radiometer with a broad bandwidth, high absorbance coating as absorber was fabricated. The absorber has an absorbance of higher than 99% in both 0.1 THz-3.0 THz region and in visible laser wavelengths range, which allows for an absolute measurement of THz radiation power and traceability to the International System of Units (SI). The uncertainty budget of CW THz power measurement with this radiometer is discussed, and the measurement results agreed excellently in the first international THz power comparison. Due to its high sensitivity and flat spectral responsivity, a pulse THz radiation from a THz time-domain spectrometer (THz-TDS) was absolutely measured with this radiometer.
- 9 December 2013
- Published by IOP Publishing in Metrologia
- Vol. 51 (1) , 18-24
On-line calibration for linear time-base error correction of terahertz spectrometers with echo pulses
We use a terahertz echo pulse as a transfer standard to correct linear time-base errors of a terahertz spectrometer. With this calibration technique, the linear error of the translate stage is corrected and the spectral repeatability of the spectrometer is improved. This calibration technique is able to correct each ‘shot’ of the terahertz pulse and can realize on-line calibration of the terahertz spectrum. The average of multiple measurements of carbon monoxide gas absorption lines was corrected and the deviation was reduced by a factor of 2.5 using this technique. This on-line calibration technique needs no additional optical components and causes no performance degradation of the terahertz spectrometer. It provides a simple and alternative method to the conventional interferometric technique and allows for accurate measurement of spectral properties of specimens in the terahertz region.
- 9 December 2013
- Published by IOP Publishing in Metrologia
- Vol. 51 (1) , 18-24
On-line calibration for linear time-base error correction of terahertz spectrometers with echo pulses
We use a terahertz echo pulse as a transfer standard to correct linear time-base errors of a terahertz spectrometer. With this calibration technique, the linear error of the translate stage is corrected and the spectral repeatability of the spectrometer is improved. This calibration technique is able to correct each ‘shot’ of the terahertz pulse and can realize on-line calibration of the terahertz spectrum. The average of multiple measurements of carbon monoxide gas absorption lines was corrected and the deviation was reduced by a factor of 2.5 using this technique. This on-line calibration technique needs no additional optical components and causes no performance degradation of the terahertz spectrometer. It provides a simple and alternative method to the conventional interferometric technique and allows for accurate measurement of spectral properties of specimens in the terahertz region.
- 1 March 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (5) , 5737-5742
Broadband high-absorbance coating for terahertz radiometry
We report a simple, broadband and high-absorbance coating for terahertz radiometry. The spectral properties of this coating in THz region were characterized with a home-made terahertz time-domain spectrometer. The measured spectral reflectance is less than 0.3% ranging from 0.2 THz to 0.5 THz and less than 0.1% ranging from 0.5 THz to 2.0 THz. We assembled a terahertz radiometer with this coating as absorber, and discussed its heat transfer in comparison with that of a carbon nanotube array radiometer. This coating is highly absorptive both in terahertz region and in visible light; therefore, the responsivity of this radiometer is easily traceable to National Laser Power Standards. This coating is easily fabricated. It is useful in traceability of terahertz sources and detectors to the SI units.
- 1 March 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (5) , 5737-5742
Broadband high-absorbance coating for terahertz radiometry
We report a simple, broadband and high-absorbance coating for terahertz radiometry. The spectral properties of this coating in THz region were characterized with a home-made terahertz time-domain spectrometer. The measured spectral reflectance is less than 0.3% ranging from 0.2 THz to 0.5 THz and less than 0.1% ranging from 0.5 THz to 2.0 THz. We assembled a terahertz radiometer with this coating as absorber, and discussed its heat transfer in comparison with that of a carbon nanotube array radiometer. This coating is highly absorptive both in terahertz region and in visible light; therefore, the responsivity of this radiometer is easily traceable to National Laser Power Standards. This coating is easily fabricated. It is useful in traceability of terahertz sources and detectors to the SI units.
- Open Access
- 16 May 2012
- Published by IntechOpen
Measurement of Ultrashort Optical Pulses
Open access peer-reviewed chapter
- 16 May 2012
- Published by IntechOpen
Open AccessMeasurement of Ultrashort Optical Pulses
Open access peer-reviewed chapter
- 1 November 2009
- Published by Springer Nature in Applied Physics B
- Vol. 98 (2-3) , 347-351
Shape selection of wavelets for accurate chromatic dispersion measurement of white-light spectral interferograms
- 1 November 2009
- Published by Springer Nature in Applied Physics B
- Vol. 98 (2-3) , 347-351
Shape selection of wavelets for accurate chromatic dispersion measurement of white-light spectral interferograms