Iwona Słonecka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Iwona Słonecka has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Wojciech Fornalski
Warsaw University of Technology
3 shared publications - Aneta Łukaszek-Chmielewskaa
Fire Univiersity
1 shared publication Barbara Szykuła-Piec
1 shared publicationJ. Krasowska
Faculty of Physics, Warsaw University of Technology, Warszawa, Poland
1 shared publicationK. Łukasik
Warsaw University of Technology
1 shared publication- Kamil Szewczak
Central Laboratory for Radiological Protection
1 shared publication
Latest Publications
- Open Access
- 16 April 2021
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 60 (2) , 257-265
Application of Bayesian statistics for radiation dose assessment in mixed beta-gamma fields
The present paper proposes a novel method, based on Bayesian statistics, as a new approach in the field of thermoluminescence dosimetry for the assessment of personal doses in mixed beta-gamma radiation fields. The method can be utilized in situations when the classical way of dose calculation is insufficient or impossible. The proposed method uses a prior function which can be assigned to the unknown parameter and the likelihood function obtained from an experiment, which together can be transformed into the posterior probability distribution of the sought parameter. Finally, the distribution is converted to the value of the dose. The proposed method is supported by analytical and Monte Carlo calculations, which confirmed the results obtained through the Bayesian approach.
- 16 April 2021
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 60 (2) , 257-265
Open AccessApplication of Bayesian statistics for radiation dose assessment in mixed beta-gamma fields
The present paper proposes a novel method, based on Bayesian statistics, as a new approach in the field of thermoluminescence dosimetry for the assessment of personal doses in mixed beta-gamma radiation fields. The method can be utilized in situations when the classical way of dose calculation is insufficient or impossible. The proposed method uses a prior function which can be assigned to the unknown parameter and the likelihood function obtained from an experiment, which together can be transformed into the posterior probability distribution of the sought parameter. Finally, the distribution is converted to the value of the dose. The proposed method is supported by analytical and Monte Carlo calculations, which confirmed the results obtained through the Bayesian approach.
- Open Access
- 1 January 2019
- Published by CNBOP-PIB Centrum Naukowo-Badawcze Ochrony Przeciwpozarowej in Safety and Fire Technology
- Vol. 54 (2) , 168-173
Short-Term Measurements of Radon Concentrations in Selected Residential Buildings
- 1 January 2019
- Published by CNBOP-PIB Centrum Naukowo-Badawcze Ochrony Przeciwpozarowej in Safety and Fire Technology
- Vol. 54 (2) , 168-173
Open AccessShort-Term Measurements of Radon Concentrations in Selected Residential Buildings
- Open Access
- 21 November 2018
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (1) , 49-57
Simplified Bayesian method: application in cytogenetic biological dosimetry of mixed n + γ radiation fields
This article describes the application of a simplified Bayesian method for estimation of doses from a mixed field using cytogenetic biological dosimetry, taking as an example neutron and gamma radiation emitted from the MARIA nuclear research reactor in Poland. The Bayesian approach is a good alternative to the commonly used iterative method, which allows separate dose estimation. In the present paper, a computer program, which uses the iterative and simplified Bayesian methods to calculate mixed radiation doses, is introduced.
- 21 November 2018
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (1) , 49-57
Open AccessSimplified Bayesian method: application in cytogenetic biological dosimetry of mixed n + γ radiation fields
This article describes the application of a simplified Bayesian method for estimation of doses from a mixed field using cytogenetic biological dosimetry, taking as an example neutron and gamma radiation emitted from the MARIA nuclear research reactor in Poland. The Bayesian approach is a good alternative to the commonly used iterative method, which allows separate dose estimation. In the present paper, a computer program, which uses the iterative and simplified Bayesian methods to calculate mixed radiation doses, is introduced.
- Open Access
- 4 June 2018
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 57 (3) , 195-203
Analytical and quasi-Bayesian methods as development of the iterative approach for mixed radiation biodosimetry
The present paper proposes two methods of calculating components of the dose absorbed by the human body after exposure to a mixed neutron and gamma radiation field. The article presents a novel approach to replace the common iterative method in its analytical form, thus reducing the calculation time. It also shows a possibility of estimating the neutron and gamma doses when their ratio in a mixed beam is not precisely known.
- 4 June 2018
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 57 (3) , 195-203
Open AccessAnalytical and quasi-Bayesian methods as development of the iterative approach for mixed radiation biodosimetry
The present paper proposes two methods of calculating components of the dose absorbed by the human body after exposure to a mixed neutron and gamma radiation field. The article presents a novel approach to replace the common iterative method in its analytical form, thus reducing the calculation time. It also shows a possibility of estimating the neutron and gamma doses when their ratio in a mixed beam is not precisely known.
- Open Access
- 1 January 2018
- Published by VM Media Group sp. z o.o in Nuclear Medicine Review
- Vol. 21 (1) , 37-41
Calibration factor fluctuation for radiological protection instruments used in Nuclear Medicine Departments - experience from CLOR
BACKGROUND: The calibration of the dosimetric instruments is a basis of safety of the people working with the ionization radiation. The necessity of calibration is especially important in the institutions where the open radioactive sources are used. The paper presents the abilities of CLOR's radiological protection instruments calibration facility and the important conclusions from calibrations results for group of instruments used in Nuclear Medicine Department in Poland. MATERIALS AND METHODS: The results for five types of instruments dedicated for dose rate as well as for contamination measurements were presented. Analyzes were based on the results presented at calibration certificated of chosen instruments. RESULTS: It has been shown that the calibration factor might fluctuate by 50% in period of one year for particular instrument as well as for more than 100% for two instruments of the same type. CONCLUSIONS: The presented results prove the importance of the calibration process and it is evidence that the calibration process of the radiation protection instruments should be performed periodically for the test of dose rate measurements as well as for contamination measurements abilities.
- 1 January 2018
- Published by VM Media Group sp. z o.o in Nuclear Medicine Review
- Vol. 21 (1) , 37-41
Open AccessCalibration factor fluctuation for radiological protection instruments used in Nuclear Medicine Departments - experience from CLOR
BACKGROUND: The calibration of the dosimetric instruments is a basis of safety of the people working with the ionization radiation. The necessity of calibration is especially important in the institutions where the open radioactive sources are used. The paper presents the abilities of CLOR's radiological protection instruments calibration facility and the important conclusions from calibrations results for group of instruments used in Nuclear Medicine Department in Poland. MATERIALS AND METHODS: The results for five types of instruments dedicated for dose rate as well as for contamination measurements were presented. Analyzes were based on the results presented at calibration certificated of chosen instruments. RESULTS: It has been shown that the calibration factor might fluctuate by 50% in period of one year for particular instrument as well as for more than 100% for two instruments of the same type. CONCLUSIONS: The presented results prove the importance of the calibration process and it is evidence that the calibration process of the radiation protection instruments should be performed periodically for the test of dose rate measurements as well as for contamination measurements abilities.