LFLuis M. P. Fernandes

Luis M. P. Fernandes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luis M. P. Fernandes has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radon-induced backgrounds in the NEXT-100 experiment

    by C. Cortes-Parra, P. Novella, G. Martínez-Lema, H. Almazán, V. Álvarez, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, et al.

    A bstract: The NEXT-100 detector at the LSC aims at the first competitive search for the 0 νββ decay using a high-pressure 136 Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal 222 Rn activity is found to be (0.95 ± 0.04(stat) ± 0.09(sys)) Bq/m 3 , while no traces of 220 Rn have been observed. Most of the 222 Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced 214 Bi of (0.97 ± 0.05(stat) ± 0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0 νββ region of interest is evaluated as (7.3 ± 1.5(stat) ± 0.8(sys)) × 10 − 4 counts/(keV · kg · yr) after selection of the fully contained events. This background index is reduced to ∼ 4 × 10 − 5 counts/(keV · kg · yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

  • Open Access

    First results of the NEXT-100 detector using 83mKr decays

    by G. Martínez-Lema, C. Hervés Carrete, S. Torelli, M. Cid Laso, P. Vázquez Cabaleiro, B. Palmeiro, J. A. Hernando Morata, J. J. Gómez-Cadenas, C. Adams, H. Almazán, et al.

    The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ 136 X e using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ E - 1 / 2 extrapolation to $$Q_{\beta \beta }$$ Q β β yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

  • Open Access

    A large area gas proportional scintillation counter with a ring-shaped anode for x- and gamma-ray spectroscopy

    by P.A.O.C. Silva, L.M.P. Fernandes, J.M.F. dos Santos, C.M.B. Monteiro

    Gas Proportional Scintillation Counters (GPSCs) are noble gas detectors in which the primary ionization charge generated by radiation interactions is amplified via electroluminescence (EL) in the gas. Under an external electric field, the primary ionization electrons drift into a region where the field exceeds the gas scintillation threshold. Compared to charge amplification via electron avalanches, EL amplification provides higher gain with improved signal-to-noise ratio, no space charge effects, and better immunity to radiofrequency noise and electrical discharges. GPSCs have been used in applications such as x-ray fluorescence analysis and x- and γ-ray astrophysics. Their high resistance to radiation damage, wide operational temperature range, simple yet flexible design, and large detection area capability are notable advantages. However, the solid angle subtended by the photosensor varies with the EL emission position, causing the detected signal to depend on the radiation interaction location. This limits the size of the detector's radiation window relative to the photosensor. To overcome these limitations, we recently proposed a novel and simple GPSC design that ensures a constant solid angle across the scintillation region. In this configuration, a single annular anode electrode, centered on the photosensor axis, defines a localized scintillation region near its surface. As a result, the entire region maintains a fixed solid angle with respect to the photosensor, making the EL signal independent of the interaction position. This design enables a large window-to-photosensor size ratio while maintaining uniform response. Previously, we developed a comprehensive simulation tool incorporating radiation absorption, electron drift, EL emission and light detection, which was validated against an annular-anode GPSC prototype. In this work, we use this simulation tool to explore the optimal geometrical parameters of the annular anode GPSC, aiming to balance energy resolution and the different parameters, mamely the detector window-to-photosensor radius ratio.

  • Top Cited Papers
    Open Access

    The NEXT-100 Detector

    by C. Adams, H. Almazán, V. Álvarez, A. I. Aranburu, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C. D. R. Azevedo, et al.

    The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ ≤ 1 % FWHM at the $$Q_{\beta \beta }$$ Q β β value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ ∼ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ 74 V cm - 1 and $$118\hbox { V cm}^{-1}$$ 118 V cm - 1 , respectively. Alpha decays from the $$^{222}$$ 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.


  • Barium ion sensing with IPG K + molecular probes

    by R. L. Miller, N. Byrnes, C. G. Cameron, A. J. Carlson, E. Dey, R. Madigan, J. Medina, S. Melancon, K. E. Navarro, F. W. Foss, et al.

    IPG K + chemosensors are effective for Ba 2+ detection in aqueous solution and low-background single-ion fluorescence microscopy.


  • Open Access

    Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation

    by NEXT Collaboration, I. Parmaksiz, K. Mistry, E. Church, C. Adams, J. Asaadi, J. Baeza-Rubio, K. Bailey, N. Byrnes, B. J. P. Jones, et al.

    We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ 58.47 ± 0.02 and $$181.39\pm {0.28}$$ 181.39 ± 0.28 times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .


  • Open Access

    Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

    by M. Martínez-Vara, K. Mistry, F. Pompa, B. J. P. Jones, J. Martín-Albo, M. Sorel, C. Adams, H. Almazán, V. Álvarez, B. Aparicio, et al.

    A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ cos θ ¯ and $$ \overline{T_1} $$ T 1 ¯ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.


  • Top Cited Papers

    The helion charge radius from laser spectroscopy of muonic helium-3 ions

    by Karsten Schuhmann, Luis M. P. Fernandes, François Nez, Marwan Abdou Ahmed, Fernando D. Amaro, Pedro Amaro, François Biraben, Tzu-Ling Chen, Daniel S. Covita, Andreas J. Dax, et al.

    Hydrogen-like light muonic ions, in which one negative muon replaces all of the electrons, are extremely sensitive probes of nuclear structure. Using pulsed laser spectroscopy, we have measured three 2 S -2 P transitions in the muonic helium-3 (μ 3 He + ) ion, an ion formed by a negative muon and bare helium-3 nucleus. This allowed us to extract the Lamb shift, the 2 P fine structure splitting, and the 2 S -hyperfine splitting in μ 3 He + . Comparing these measurements with theory, we determined the root-mean-square charge radius of the helion ( 3 He nucleus) to be r h = 1.97007(94) fm, in good agreement with the value from elastic electron scattering but a factor 15 more accurate. Our results represent benchmarks for few-nucleon theories and open the way for precision quantum electrodynamics tests in He atoms and ions.


  • Open Access

    Solid angle compensation in gas proportional scintillation counters using an annular anode with azimuthal geometry

    by P.A.O.C. Silva, L.M.P. Fernandes, J.M.F. dos Santos, C.M.B. Monteiro

    A new, simple and robust design for a gas proportional scintillation counter (GPSC) is studied. One sole electrode, the anode, is used to define the electric field in the drift and scintillation regions of the detector volume. The anode has an annular shape aligned with the photosensor axis. Such design allows to keep constant the solid angle subtended by the photosensor relative to the different positions of the scintillation region. Having an oblong anode with a 10 cm inner diameter and a 5 cm photomultiplier tube placed 5 cm below the anode, an energy resolution of 12.0 % FWHM has been achieved for a 10 kV anode bias, the maximum voltage that could be applied to the anode in the present prototype. According to simulations, energy resolutions of ~10 % can be achieved for anode voltages of ~13 kV, a value comparable to the 9–10 % achieved in GPSC using solid angle variation compensation. Independently of having a constant solid angle, the absolute value of the solid angle must be considered, a lower number of EL photons detected at the photosensor due to a reduced solid angle may contribute to the GPSC energy resolution degradation. In addition, non-uniformities present in the photosensor or in the GPSC must be taken into account, since they will contribute to a dependence of the pulse amplitude on the radiation interaction position despite the constant solid angle subtended by the photosensor relative to the scintillation region.


  • Open Access

    Publisher Correction: Measuring the α-particle charge radius with muonic helium-4 ions

    by Julian J. Krauth, Karsten Schuhmann, Marwan Abdou Ahmed, Fernando D. Amaro, Pedro Amaro, François Biraben, Tzu-Ling Chen, Daniel S. Covita, Andreas J. Dax, Marc Diepold, et al.

    A Correction to this paper has been published: https://doi.org/10.1038/s41586-021-03360-2.