Vera Aleksandrovna Khokhlova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vera Aleksandrovna Khokhlova has a total of 213 co-authors. Here are the top co-authors by number of shared publications:
- Oleg A. Sapozhnikov
Applied Physics Laboratory, University of Washington, Seattle, WA, USA
41 shared publications - Michael R. Bailey
Department of Urology, University of Washington, Seattle, Washington
27 shared publications - Tatiana D. Khokhlova
Department of Medicine, Division of Gastroenterology, University of Washington, Seattle, WA, USA
25 shared publications - Petr V. Yuldashev
Faculty of Physics, Moscow State University, Moscow, Russia
24 shared publications Lawrence A. Crum
Ctr. for Industrial and Medical Ultrasound, Appl. Phys. Lab., Univ. of Washington, Seattle, WA
18 shared publications- Wayne Kreider
Applied Physics Laboratory, University of Washington, Seattle, WA, USA
18 shared publications
Latest Publications
- 22 October 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107876
Non-thermal ultrasound-guided fractionation of human leiomyosarcoma with boiling histotripsy: an ex vivo feasibility study
- 22 October 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107876
Non-thermal ultrasound-guided fractionation of human leiomyosarcoma with boiling histotripsy: an ex vivo feasibility study
- 1 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 837-846
Respiratory Motion Effects and Mitigation Strategies on Boiling Histotripsy in Porcine Liver and Kidney
Boiling histotripsy (BH) is a pulsed high-intensity focused ultrasound (HIFU)-based method of extracorporeal non-thermal tissue disintegration under real-time ultrasound (US) guidance. Respiratory motion in abdominal targets can affect BH precision and completeness. This study compares two motion mitigation strategies based on pulse/echo US motion tracking: robotic arm-based unidirectional motion compensation by HIFU transducer manipulation and BH pulse gating during expiratory pause. BH ablations were generated in liver and kidney of anesthetized pigs with 2-10ms pulses using 256-element 1.5-MHz HIFU array. A coaxial US imaging probe was used for targeting, tracking skin surface and monitoring real-time bubble activity. The axial (anterior-posterior, AP) displacement of the skin surface was found to be synchronous with liver and kidney motion in both cranio-caudal (CC) and AP directions. BH lesions were produced either with no motion mitigation, or with pulse gating, or with 1D motion compensation. Dimensions of completely fractionated and affected tissue areas were measured histologically. In liver, gating and motion compensation improved fractionation completeness within targeted volumes and reduced off-target tissue damage in AP direction vs no motion mitigation; only gating reduced off-target damage in CC direction. In kidney, gating improved BH completeness in both directions vs no mitigation, but did not affect off-target damage due to lower displacement amplitudes in kidney comparable with gating tolerance limits. In both liver and kidney, gating increased treatment time by 24%. These results suggest that BH pulse gating using US-based AP skin surface tracking is an adequate approach for treating organs with pronounced 3D respiratory motion.
- 1 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 837-846
Respiratory Motion Effects and Mitigation Strategies on Boiling Histotripsy in Porcine Liver and Kidney
Boiling histotripsy (BH) is a pulsed high-intensity focused ultrasound (HIFU)-based method of extracorporeal non-thermal tissue disintegration under real-time ultrasound (US) guidance. Respiratory motion in abdominal targets can affect BH precision and completeness. This study compares two motion mitigation strategies based on pulse/echo US motion tracking: robotic arm-based unidirectional motion compensation by HIFU transducer manipulation and BH pulse gating during expiratory pause. BH ablations were generated in liver and kidney of anesthetized pigs with 2-10ms pulses using 256-element 1.5-MHz HIFU array. A coaxial US imaging probe was used for targeting, tracking skin surface and monitoring real-time bubble activity. The axial (anterior-posterior, AP) displacement of the skin surface was found to be synchronous with liver and kidney motion in both cranio-caudal (CC) and AP directions. BH lesions were produced either with no motion mitigation, or with pulse gating, or with 1D motion compensation. Dimensions of completely fractionated and affected tissue areas were measured histologically. In liver, gating and motion compensation improved fractionation completeness within targeted volumes and reduced off-target tissue damage in AP direction vs no motion mitigation; only gating reduced off-target damage in CC direction. In kidney, gating improved BH completeness in both directions vs no mitigation, but did not affect off-target damage due to lower displacement amplitudes in kidney comparable with gating tolerance limits. In both liver and kidney, gating increased treatment time by 24%. These results suggest that BH pulse gating using US-based AP skin surface tracking is an adequate approach for treating organs with pronounced 3D respiratory motion.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 564-580
xDDx: A Numerical Toolbox for Ultrasound Transducer Characterization and Design With Acoustic Holography
Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( $10^{{10}}$ – $10^{{11}}$ operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s–3 min for GPUs and 1.6 s–57 min for CPUs.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 564-580
xDDx: A Numerical Toolbox for Ultrasound Transducer Characterization and Design With Acoustic Holography
Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( $10^{{10}}$ – $10^{{11}}$ operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s–3 min for GPUs and 1.6 s–57 min for CPUs.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 596-606
Dynamic Mode Decomposition for Transient Cavitation Bubbles Imaging in Pulsed High-Intensity Focused Ultrasound Therapy
Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated to tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and optimized for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filters - singular value decomposition (SVD) and infinite impulse response (IIR) highpass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 596-606
Dynamic Mode Decomposition for Transient Cavitation Bubbles Imaging in Pulsed High-Intensity Focused Ultrasound Therapy
Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated to tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and optimized for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filters - singular value decomposition (SVD) and infinite impulse response (IIR) highpass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression.
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3) , 1682-1693
Fully nonlinear three-dimensional modeling of parametric interactions in the field of a dual-frequency acoustic array
An algorithm is developed for fully nonlinear three-dimensional (3D) simulation of a difference-frequency acoustic beam resulting from the interaction of two high-intensity pump waves. Simulations are performed in the frequency domain based on the Khokhlov–Zabolotskaya–Kuznetsov equation. A spectrum filtering method is used to enable accurate solutions for the difference-frequency fields in strongly nonlinear beams and with a high downshift frequency ratio using only dozens of spectral components retained in the algorithm. As an example, the dual-frequency operation of an underwater multi-element ellipsoidal array is considered, and numerical solutions describing parametric interactions in the array field are analyzed. It is shown that difference-frequency beams are more symmetric in transverse directions compared with the pump beams. The most efficient parametric generation of difference-frequency beams corresponded to close and beyond shock-forming conditions. Axial pressure amplitude of the difference frequency was shown to grow first quadratically with the source pressure following the quasi-linear solution and then linearly once shocks start to develop. The percentage of the total power converted to the difference frequency from pump waves increased at high power outputs without saturation. Up to twofold increase in directivity angles of difference-frequency beams under shock-forming conditions was observed compared with quasi-linear conditions.
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3) , 1682-1693
Fully nonlinear three-dimensional modeling of parametric interactions in the field of a dual-frequency acoustic array
An algorithm is developed for fully nonlinear three-dimensional (3D) simulation of a difference-frequency acoustic beam resulting from the interaction of two high-intensity pump waves. Simulations are performed in the frequency domain based on the Khokhlov–Zabolotskaya–Kuznetsov equation. A spectrum filtering method is used to enable accurate solutions for the difference-frequency fields in strongly nonlinear beams and with a high downshift frequency ratio using only dozens of spectral components retained in the algorithm. As an example, the dual-frequency operation of an underwater multi-element ellipsoidal array is considered, and numerical solutions describing parametric interactions in the array field are analyzed. It is shown that difference-frequency beams are more symmetric in transverse directions compared with the pump beams. The most efficient parametric generation of difference-frequency beams corresponded to close and beyond shock-forming conditions. Axial pressure amplitude of the difference frequency was shown to grow first quadratically with the source pressure following the quasi-linear solution and then linearly once shocks start to develop. The percentage of the total power converted to the difference frequency from pump waves increased at high power outputs without saturation. Up to twofold increase in directivity angles of difference-frequency beams under shock-forming conditions was observed compared with quasi-linear conditions.
- Open Access
Dynamic Mode Decomposition for Transient Cavitation Bubbles Imaging in Pulsed High Intensity Focused Ultrasound Therapy
Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated to tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and optimized for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filters - singular value decomposition (SVD) and infinite impulse response (IIR) highpass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression. Abstract Figure:
Open AccessDynamic Mode Decomposition for Transient Cavitation Bubbles Imaging in Pulsed High Intensity Focused Ultrasound Therapy
Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated to tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and optimized for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filters - singular value decomposition (SVD) and infinite impulse response (IIR) highpass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression. Abstract Figure:
- Open Access
- 1 February 2024
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 70 (1) , 165-174
Electronic Focus Steering Capabilities of a Diagnostic-Type Linear Ultrasound Array Designed for High Power Therapy and Its Visualization
The focus steering capabilities of a 1 MHz linear phased array transducer (64 rectangular elements, 14.8 × 51.2 mm aperture) intended for drug delivery applications in abdominal organs were assessed and compared with its design-stage computer model. Acoustic fields generated by the transducer and predicted by the models of an ideal array with uniformly vibrating elements and either a plane or a cylindrically focused surface were simulated using the Rayleigh integral and angular spectrum methods. The boundary conditions for the transducer were reconstructed from acoustic holography measurements performed for selected focusing configurations of the array and also synthesized from holography data measured for each of its individual elements. It was shown that the transducer field with electronic focus steering can be accurately synthesized based on the holography data of its elements, which significantly simplified acoustic field characterization. Variability of the power and directivity patterns of the array elements were analyzed. A twofold smaller range of electronic steering in the transverse direction for the transducer compared to its computer model is discussed.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 70 (1) , 165-174
Open AccessElectronic Focus Steering Capabilities of a Diagnostic-Type Linear Ultrasound Array Designed for High Power Therapy and Its Visualization
The focus steering capabilities of a 1 MHz linear phased array transducer (64 rectangular elements, 14.8 × 51.2 mm aperture) intended for drug delivery applications in abdominal organs were assessed and compared with its design-stage computer model. Acoustic fields generated by the transducer and predicted by the models of an ideal array with uniformly vibrating elements and either a plane or a cylindrically focused surface were simulated using the Rayleigh integral and angular spectrum methods. The boundary conditions for the transducer were reconstructed from acoustic holography measurements performed for selected focusing configurations of the array and also synthesized from holography data measured for each of its individual elements. It was shown that the transducer field with electronic focus steering can be accurately synthesized based on the holography data of its elements, which significantly simplified acoustic field characterization. Variability of the power and directivity patterns of the array elements were analyzed. A twofold smaller range of electronic steering in the transverse direction for the transducer compared to its computer model is discussed.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 341-353
Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 341-353
Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
- 20 December 2023
- Published by Elsevier in Ultrasonics
- Vol. 138, 107225
Histology-based quantification of boiling histotripsy outcomes via ResNet-18 network: Towards mechanical dose metrics
- 20 December 2023
- Published by Elsevier in Ultrasonics
- Vol. 138, 107225
Histology-based quantification of boiling histotripsy outcomes via ResNet-18 network: Towards mechanical dose metrics
- Open Access
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A278
Mechanical disintegration of benign and malignant tumors in ex vivo human prostate tissues using boiling histotripsy
The feasibility of boiling histotripsy (BH) to mechanically liquefy ex vivo human prostate tissue with benign hyperplasia (BPH) and adenocarcinoma (PCa) was assessed. Volumetric BH lesions were generated in fresh tissue samples under B-mode guidance using a 1.5-MHz focused transducer, 10- and 1-ms pulses with 1% duty cycle. Prior to BH exposures, the samples were analyzed using shear wave elastography (SWE) to determine whether their mechanical properties were clinically representative. Completeness and efficiency of ablation for BH lesions were evaluated grossly, histologically, and using B-mode ultrasound. The SWE measured Young’s modulus of the samples was shown to be within the typical range observed clinically. During the exposures, BH-induced hyperechogenic bubbles were visible using B-mode, and post-treatment hypoechoic regions indicated successful tissue fractionation. Gross analysis of the exposed samples with BPH revealed ablation of the targeted tissue inside stiff BPH nodules. The sonications using 1-ms pulses (with 150 pulses-per-focus) were twofold faster comparing to 10-ms (with 30 pulses-per-focus). Histological analysis revealed liquefied lesions containing homogenized cell debris in all BPH samples. A pilot experiment of human PCa tumor fractionation into subcellular fragments was confirmed histologically. [Work supported by R01CA258581, R01DK119310, and RSF 20-12-00145.]
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A278
Open AccessMechanical disintegration of benign and malignant tumors in ex vivo human prostate tissues using boiling histotripsy
The feasibility of boiling histotripsy (BH) to mechanically liquefy ex vivo human prostate tissue with benign hyperplasia (BPH) and adenocarcinoma (PCa) was assessed. Volumetric BH lesions were generated in fresh tissue samples under B-mode guidance using a 1.5-MHz focused transducer, 10- and 1-ms pulses with 1% duty cycle. Prior to BH exposures, the samples were analyzed using shear wave elastography (SWE) to determine whether their mechanical properties were clinically representative. Completeness and efficiency of ablation for BH lesions were evaluated grossly, histologically, and using B-mode ultrasound. The SWE measured Young’s modulus of the samples was shown to be within the typical range observed clinically. During the exposures, BH-induced hyperechogenic bubbles were visible using B-mode, and post-treatment hypoechoic regions indicated successful tissue fractionation. Gross analysis of the exposed samples with BPH revealed ablation of the targeted tissue inside stiff BPH nodules. The sonications using 1-ms pulses (with 150 pulses-per-focus) were twofold faster comparing to 10-ms (with 30 pulses-per-focus). Histological analysis revealed liquefied lesions containing homogenized cell debris in all BPH samples. A pilot experiment of human PCa tumor fractionation into subcellular fragments was confirmed histologically. [Work supported by R01CA258581, R01DK119310, and RSF 20-12-00145.]