György Czél
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
György Czél has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Peter Kaali
Nynas AB, Oljeraffinaderiet
4 shared publicationsDane Momcilovic
2 shared publications- Sigbritt Karlsson
Department of Fibre and Polymer Technology, School of Chemical Science and Engineering, KTH – Royal Institute of Technology, Teknikringen 56-58, SE-10044 Stockholm, Sweden
2 shared publications A. Kelemen
Miskolc University
1 shared publicationAgneta Markström
Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, National Respiratory Centre, Stockholm SE-18 288, Sweden
1 shared publicationD. Solyom
Regional University Knowledge Center
1 shared publication
Latest Publications
- 1 February 2015
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 812, 83-88
Degradation Behaviour of Zeolite Filled Polyurethanes under In Vitro Aging Process
In this study the degradation and ion/zeolite release processes of in vitro aged zeolite loaded polyurethane composites were evaluated. Two in vitro artificial aging solutions were used; artificial lysosomal fluid (ALF) and Gamble ́s solution and the total exposure time was 12 weeks. Periodically, SEM micrographs were taken of the surface of polyester type polyurethane-zeolite composites. After exposure to ALF solution the samples showed round holes and a rougher surface in general over time. Micrographs of the samples immersed in Gamble’s solution exhibited different signs of degradation with damage features on the surfaces, understood as black holes and a rougher surface pattern. In addition varying amount of salt was also observed on the surfaces that might influence the ion/zeolite release. Furthermore, the zeolite filler caused remarkable changes in mechanical properties after the aging process, which could not be discerned.
- 1 February 2015
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 812, 83-88
Degradation Behaviour of Zeolite Filled Polyurethanes under In Vitro Aging Process
In this study the degradation and ion/zeolite release processes of in vitro aged zeolite loaded polyurethane composites were evaluated. Two in vitro artificial aging solutions were used; artificial lysosomal fluid (ALF) and Gamble ́s solution and the total exposure time was 12 weeks. Periodically, SEM micrographs were taken of the surface of polyester type polyurethane-zeolite composites. After exposure to ALF solution the samples showed round holes and a rougher surface in general over time. Micrographs of the samples immersed in Gamble’s solution exhibited different signs of degradation with damage features on the surfaces, understood as black holes and a rougher surface pattern. In addition varying amount of salt was also observed on the surfaces that might influence the ion/zeolite release. Furthermore, the zeolite filler caused remarkable changes in mechanical properties after the aging process, which could not be discerned.
- 26 March 2013
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 752, 268-274
Modelling of Ion Distribution in Single, Binary and Ternary Ion Exchanged Zeolite Used for Biomedical Applications
Based on the previously published sodium and Ag, Cu, Zn ion-exchange and re-excange experiments we took an attempt to modeling its structure. We also took in account the ion release experimental results and the rigorous survey of the literature data when we positioned the ions in zeolite crystal structure. Therefore the current study aimed to modeling the ion distribution of single, binary and ternary ion-exchanged zeolite systems used for antimicrobial purposes, where the variation of silver, copper and zinc is incorporated into the zeolite structure. The tool of modelling was “CrystalMaker6” developed by CrystalMaker Software Ltd.
- 26 March 2013
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 752, 268-274
Modelling of Ion Distribution in Single, Binary and Ternary Ion Exchanged Zeolite Used for Biomedical Applications
Based on the previously published sodium and Ag, Cu, Zn ion-exchange and re-excange experiments we took an attempt to modeling its structure. We also took in account the ion release experimental results and the rigorous survey of the literature data when we positioned the ions in zeolite crystal structure. Therefore the current study aimed to modeling the ion distribution of single, binary and ternary ion-exchanged zeolite systems used for antimicrobial purposes, where the variation of silver, copper and zinc is incorporated into the zeolite structure. The tool of modelling was “CrystalMaker6” developed by CrystalMaker Software Ltd.
- 12 November 2012
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 729, 234-239
Single, Binary and Ternary Ion Exchanged Zeolite as an Effective Bioactive Filler for Biomedical Polymer Composites
The preparation and modelling of single, binary and ternary ion exchanged zeolites that express antimicrobial efficiency is discussed. As experimental material A type zeolite was used and different variations of Ag, Cu and Zn ions were incorporated into the crystal structure. Antimicrobial efficiency is based on the ion concentration and ion release of the zeolite, therefore the maximum cation-exchange capacities (CEC) were determined for each of the single ions. After the determination of CEC the preparation of binary and ternary ion-exchanged zeolite samples were prepared by the mixture of silver, copper and zinc nitrate solutions and the composition of the samples was determined by atomic absorption spectroscopy (AAS). To verify the bioactive effect, the minimum inhibitory concentration (MIC) of single, binary and ternary ion-exchanged zeolite A was determined for bacteria strains.
- 12 November 2012
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 729, 234-239
Single, Binary and Ternary Ion Exchanged Zeolite as an Effective Bioactive Filler for Biomedical Polymer Composites
The preparation and modelling of single, binary and ternary ion exchanged zeolites that express antimicrobial efficiency is discussed. As experimental material A type zeolite was used and different variations of Ag, Cu and Zn ions were incorporated into the crystal structure. Antimicrobial efficiency is based on the ion concentration and ion release of the zeolite, therefore the maximum cation-exchange capacities (CEC) were determined for each of the single ions. After the determination of CEC the preparation of binary and ternary ion-exchanged zeolite samples were prepared by the mixture of silver, copper and zinc nitrate solutions and the composition of the samples was determined by atomic absorption spectroscopy (AAS). To verify the bioactive effect, the minimum inhibitory concentration (MIC) of single, binary and ternary ion-exchanged zeolite A was determined for bacteria strains.
- 1 September 2010
- Published by Elsevier in Polymer Degradation and Stability
- Vol. 95 (9) , 1456-1465
Antimicrobial properties of Ag+ loaded zeolite polyester polyurethane and silicone rubber and long-term properties after exposure to in-vitro ageing
- 1 September 2010
- Published by Elsevier in Polymer Degradation and Stability
- Vol. 95 (9) , 1456-1465
Antimicrobial properties of Ag+ loaded zeolite polyester polyurethane and silicone rubber and long-term properties after exposure to in-vitro ageing
- 1 September 2010
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 659, 135-140
Flame Retardant Polyethylene Terephthalate Fibers Added with Melamine Based FR Additive
Polyethylene terephtalate (PET) was modified with a melamine derivative additive in order to obtain flame resistance of fiber products. The effect of flame retardant (FR) agent was determined by measuring rheological and combustion properties of PET linear polyester. The solubility of additive was investigated using a torque-rheometer. In course of the rheological investigation, the rate of solution was determined. The effect of FR additive on the melt rheology could well be traced by using a torque-rheometer and its evaluation method. After preparation of polyethylene terephtalat and melamine mixture melt, fibers were made by coextrusion centrifugal apparatus. The flame retardancy of fibers were determined by standard combustion tests. These tests were performed in order to determine the oxygen index of fiber products. It was proven that a favourable degree of combustibility of PET can be obtained under the influece of adding melamine-derivative additive.
- 1 September 2010
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 659, 135-140
Flame Retardant Polyethylene Terephthalate Fibers Added with Melamine Based FR Additive
Polyethylene terephtalate (PET) was modified with a melamine derivative additive in order to obtain flame resistance of fiber products. The effect of flame retardant (FR) agent was determined by measuring rheological and combustion properties of PET linear polyester. The solubility of additive was investigated using a torque-rheometer. In course of the rheological investigation, the rate of solution was determined. The effect of FR additive on the melt rheology could well be traced by using a torque-rheometer and its evaluation method. After preparation of polyethylene terephtalat and melamine mixture melt, fibers were made by coextrusion centrifugal apparatus. The flame retardancy of fibers were determined by standard combustion tests. These tests were performed in order to determine the oxygen index of fiber products. It was proven that a favourable degree of combustibility of PET can be obtained under the influece of adding melamine-derivative additive.
- 10 September 2009
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 115 (2) , 802-810
Degradation of biomedical polydimethylsiloxanes during exposure to in vivo biofilm environment monitored by FE‐SEM, ATR‐FTIR, and MALDI‐TOF MS
Polymers used for biomedical purposes in medical devices are usually requested to be inert to degradation. This article describes that slow irreversible changes were observed in silicone surfaces exposed to in vivo biofilms even if silicone, in general, is supposed to have excellent long‐term properties. Tracheostomy tubes made of silicone rubber were exposed to in vivo biofilm environments in clinical tests for periods of 1, 3, and 6 months. The chemical degradation was monitored by MALDI‐TOF MS, ATR‐FTIR, and FE‐SEM. In addition, the physical changes were monitored by contact angle and hardness measurements. Cyclic polydimethylsiloxane (PDMS) was detected on the surfaces of new (unaged) silicones. On the surfaces of the in vivo samples new compounds, presumably linear methyl‐hydroxyl‐terminated PDMS, were detected in addition to cyclic PDMS. These compounds may be formed as a result of the hydrolysis of linear dimethyl terminated PDMS, which is also present in the silicone rubber. ATR‐FTIR spectroscopy confirmed that hydrolysis had indeed occurred during the in vivo exposure, since SiOH groups were detected. Furthermore, significant changes in the topography were detected by FE‐SEM, indicating the initiation of degradation. No significant changes in the contact angle of the in vivo used samples were observed, but this information may be shielded by the fact that biofilm may remain on the surface, despite the thorough cleaning before the analysis. It is also possible that the surface hydrophobicity was recovered by the diffusion of linear low‐molecular‐weight compounds from the bulk. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2010
- 10 September 2009
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 115 (2) , 802-810
Degradation of biomedical polydimethylsiloxanes during exposure to in vivo biofilm environment monitored by FE‐SEM, ATR‐FTIR, and MALDI‐TOF MS
Polymers used for biomedical purposes in medical devices are usually requested to be inert to degradation. This article describes that slow irreversible changes were observed in silicone surfaces exposed to in vivo biofilms even if silicone, in general, is supposed to have excellent long‐term properties. Tracheostomy tubes made of silicone rubber were exposed to in vivo biofilm environments in clinical tests for periods of 1, 3, and 6 months. The chemical degradation was monitored by MALDI‐TOF MS, ATR‐FTIR, and FE‐SEM. In addition, the physical changes were monitored by contact angle and hardness measurements. Cyclic polydimethylsiloxane (PDMS) was detected on the surfaces of new (unaged) silicones. On the surfaces of the in vivo samples new compounds, presumably linear methyl‐hydroxyl‐terminated PDMS, were detected in addition to cyclic PDMS. These compounds may be formed as a result of the hydrolysis of linear dimethyl terminated PDMS, which is also present in the silicone rubber. ATR‐FTIR spectroscopy confirmed that hydrolysis had indeed occurred during the in vivo exposure, since SiOH groups were detected. Furthermore, significant changes in the topography were detected by FE‐SEM, indicating the initiation of degradation. No significant changes in the contact angle of the in vivo used samples were observed, but this information may be shielded by the fact that biofilm may remain on the surface, despite the thorough cleaning before the analysis. It is also possible that the surface hydrophobicity was recovered by the diffusion of linear low‐molecular‐weight compounds from the bulk. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2010
- 1 February 2007
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 537-538, 137-144
MAgPP an Effective Coupling Agent in Rice Husk Flour Filled Polypropylene Composites
Different properties (tensile strength, elongation, modulus, impact strength) of rice husk (RH) reinforced polypropylene (PP) coupled by Maleic-Anhydride grafted Polypropylene (MAgPP) have been investigated. MAgPP is an effective coupling agent, not only in cellulosic-fibre filled polyolefine composites, but in rice husk flour filled polypropylene composite systems as well. It gives a utilizable construction polymer matrix composite (PMC) material even at a 40 wt.% RH filling degree. The strength and modulus increases by adding the rice husk but the elongation decreases in a non-monotonic way. Micrographs shows weak coupling in between RH and PP without MAgPP.
- 1 February 2007
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 537-538, 137-144
MAgPP an Effective Coupling Agent in Rice Husk Flour Filled Polypropylene Composites
Different properties (tensile strength, elongation, modulus, impact strength) of rice husk (RH) reinforced polypropylene (PP) coupled by Maleic-Anhydride grafted Polypropylene (MAgPP) have been investigated. MAgPP is an effective coupling agent, not only in cellulosic-fibre filled polyolefine composites, but in rice husk flour filled polypropylene composite systems as well. It gives a utilizable construction polymer matrix composite (PMC) material even at a 40 wt.% RH filling degree. The strength and modulus increases by adding the rice husk but the elongation decreases in a non-monotonic way. Micrographs shows weak coupling in between RH and PP without MAgPP.
- 1 January 2005
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 473-474, 441-446
Acetabular Cup Deformation and Strength Improvement by Physical Crosslinking
- 1 January 2005
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 473-474, 441-446
Acetabular Cup Deformation and Strength Improvement by Physical Crosslinking
- 1 January 2003
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 414-415, 9-14
Pulsed Laser Deposition of Bioglass Coatings on Dental Implants
- 1 January 2003
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 414-415, 9-14
Pulsed Laser Deposition of Bioglass Coatings on Dental Implants
- 1 June 1996
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 215-216, 331-338
Gravity Influenced Convection in Al-Ni Melt
- 1 June 1996
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 215-216, 331-338
Gravity Influenced Convection in Al-Ni Melt