Mattia Busana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mattia Busana has a total of 222 co-authors. Here are the top co-authors by number of shared publications:
- Luciano Gattinoni
Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany
26 shared publications Federica Romitti
Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany
15 shared publicationsMichael Quintel
Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany
14 shared publicationsLorenzo Giosa
Centre for Human and Applied Physiological Sciences, King’s College London, London, United Kingdom
12 shared publicationsOnnen Moerer
Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany
11 shared publicationsJohn J. Marini
Department of Pulmonary and Critical Care Medicine, Regions Hospital, St. Paul, Minnesota
10 shared publications
Latest Publications
- 24 March 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 144 (6) , 1391-1399
Recirculation Quantified by Trans–Extracorporeal Membrane Oxygenation Thermodilution to Predict Mixed Venous Oxygenation during Veno-venous Extracorporeal Membrane Oxygenation: An In Vivo Porcine Study
Background: Recirculation is a major contributor to refractory hypoxemia during veno-venous extracorporeal membrane oxygenation (V-V ECMO), yet it remains difficult to measure at the bedside. In an animal study, the authors applied the trans–extracorporeal membrane oxygenation thermodilution (TET) to quantify the phenomenon, identify its determinants, and estimate the mixed venous oxygenation noninvasively. Methods: Eight pigs (65 ± 3 kg) were anesthetized and cannulated for femoral–jugular V-V ECMO. Acute respiratory distress syndrome was induced using oleic (n = 4) or hydrochloric acid (n = 4) targeting a Pa o 2 /inspired oxygen fraction of 150 mmHg. The experiment lasted 24 h, with serial measurements of blood gases, hemodynamics, and respiratory mechanics. TET was performed by injecting a bolus of cold saline downstream the membrane lung and by recording the resulting temperature changes in the drainage and return cannulas. Recirculation was calculated as the ratio of the areas under the temperature–time curves. The determinants of the recirculation were analyzed with mixed linear models, including a random intercept. The measured recirculation was incorporated in a series of mass transfer equations to estimate the mixed venous oxygen content and saturation. Results: Median recirculation was 7.4% [interquatile range, 1.1 to 22.0] and presented large intersubject variability. In 55% of measurements, recirculation was less than 10% (minimal recirculation). In the remaining measurements, the recirculation measured 27.4 [15.0 to 43.5; significant recirculation]. The ratio of extracorporeal blood flow to cardiac output measured 0.63 [0.55 to 0.72] and was the only physiologic factor correlated with recirculation (overall Pearson correlation coefficient, r = 0.67; in the significant recirculation, r = 0.81). The distance between the tip of the cannulas was, in our setup, nonsignificantly associated to the recirculation ( P = 0.74). An increased recirculation was modestly associated with a decreased mixed venous P o 2 ( r = –0.37). The noninvasive estimation of the mixed venous oxygenation was highly accurate ( r = 0.98, bias plus 0.48 ml/100 ml for the oxygen content; r = 0.98, bias plus 4% for saturation). Conclusions: TET is a promising technique to measure the recirculation during V-V ECMO. Increasing the blood flow does not always lead to an improvement in oxygenation given the tight relationship between ratio of extracorporeal blood flow to cardiac output and recirculation. The proposed numerical method allows the noninvasive estimation of the mixed venous oxygenation without the need of a pulmonary artery catheter.
- 24 March 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 144 (6) , 1391-1399
Recirculation Quantified by Trans–Extracorporeal Membrane Oxygenation Thermodilution to Predict Mixed Venous Oxygenation during Veno-venous Extracorporeal Membrane Oxygenation: An In Vivo Porcine Study
Background: Recirculation is a major contributor to refractory hypoxemia during veno-venous extracorporeal membrane oxygenation (V-V ECMO), yet it remains difficult to measure at the bedside. In an animal study, the authors applied the trans–extracorporeal membrane oxygenation thermodilution (TET) to quantify the phenomenon, identify its determinants, and estimate the mixed venous oxygenation noninvasively. Methods: Eight pigs (65 ± 3 kg) were anesthetized and cannulated for femoral–jugular V-V ECMO. Acute respiratory distress syndrome was induced using oleic (n = 4) or hydrochloric acid (n = 4) targeting a Pa o 2 /inspired oxygen fraction of 150 mmHg. The experiment lasted 24 h, with serial measurements of blood gases, hemodynamics, and respiratory mechanics. TET was performed by injecting a bolus of cold saline downstream the membrane lung and by recording the resulting temperature changes in the drainage and return cannulas. Recirculation was calculated as the ratio of the areas under the temperature–time curves. The determinants of the recirculation were analyzed with mixed linear models, including a random intercept. The measured recirculation was incorporated in a series of mass transfer equations to estimate the mixed venous oxygen content and saturation. Results: Median recirculation was 7.4% [interquatile range, 1.1 to 22.0] and presented large intersubject variability. In 55% of measurements, recirculation was less than 10% (minimal recirculation). In the remaining measurements, the recirculation measured 27.4 [15.0 to 43.5; significant recirculation]. The ratio of extracorporeal blood flow to cardiac output measured 0.63 [0.55 to 0.72] and was the only physiologic factor correlated with recirculation (overall Pearson correlation coefficient, r = 0.67; in the significant recirculation, r = 0.81). The distance between the tip of the cannulas was, in our setup, nonsignificantly associated to the recirculation ( P = 0.74). An increased recirculation was modestly associated with a decreased mixed venous P o 2 ( r = –0.37). The noninvasive estimation of the mixed venous oxygenation was highly accurate ( r = 0.98, bias plus 0.48 ml/100 ml for the oxygen content; r = 0.98, bias plus 4% for saturation). Conclusions: TET is a promising technique to measure the recirculation during V-V ECMO. Increasing the blood flow does not always lead to an improvement in oxygenation given the tight relationship between ratio of extracorporeal blood flow to cardiac output and recirculation. The proposed numerical method allows the noninvasive estimation of the mixed venous oxygenation without the need of a pulmonary artery catheter.
- Open Access
- 20 January 2026
- Published by Springer Nature in Critical Care
- Vol. 30 (1)
Lung recruitability determines the impact of PEEP on mechanical power in ARDS
Mechanical power increases with positive end-expiratory pressure (PEEP). However, its injurious potential may depend on the available lung gas volume, whic
- 20 January 2026
- Published by Springer Nature in Critical Care
- Vol. 30 (1)
Open AccessLung recruitability determines the impact of PEEP on mechanical power in ARDS
Mechanical power increases with positive end-expiratory pressure (PEEP). However, its injurious potential may depend on the available lung gas volume, whic
- 1 March 2025
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 211 (3) , 331-338
Impact of Fluid Balance on the Development of Lung Injury
Rationale: The pathophysiological relationship among fluid administration, fluid balance, and mechanical ventilation in the development of lung injury is unclear. Objectives: To quantify the relative contributions of mechanical power and fluid balance in the development of lung injury. Methods: Thirty-nine healthy female pigs, divided into four groups, were ventilated for 48 hours with high (∼18 J/min) or low (∼6 J/min) mechanical power and high (∼4 L) or low (∼1 L) targeted fluid balance. Measurements and Main Results: We measured physiological variables (e.g., end-expiratory lung gas volume, respiratory system mechanics, gas exchange, hemodynamics) and pathological variables (i.e., lung weight, wet-to-dry ratio, and histology score of lung injury). End-expiratory lung gas volume, respiratory system elastance, strain, and oxygenation significantly worsened in the two groups assigned to receive high fluid balance, irrespective of the mechanical power received. All four groups had similar lung weights (i.e., lung edema), lung wet-to-dry ratios, and pathological variables. Animals with higher fluid balance developed more ascites, which was associated with a decrease in end-expiratory lung gas volume. Conclusions: Our study did not detect a significant difference in lung injury between high and low mechanical power. Some damage is directly attributable to mechanical power, while additional injury appears to result indirectly from high fluid balance, which reduces end-expiratory lung gas volume, with ascites playing an important role in this process.
- 1 March 2025
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 211 (3) , 331-338
Impact of Fluid Balance on the Development of Lung Injury
Rationale: The pathophysiological relationship among fluid administration, fluid balance, and mechanical ventilation in the development of lung injury is unclear. Objectives: To quantify the relative contributions of mechanical power and fluid balance in the development of lung injury. Methods: Thirty-nine healthy female pigs, divided into four groups, were ventilated for 48 hours with high (∼18 J/min) or low (∼6 J/min) mechanical power and high (∼4 L) or low (∼1 L) targeted fluid balance. Measurements and Main Results: We measured physiological variables (e.g., end-expiratory lung gas volume, respiratory system mechanics, gas exchange, hemodynamics) and pathological variables (i.e., lung weight, wet-to-dry ratio, and histology score of lung injury). End-expiratory lung gas volume, respiratory system elastance, strain, and oxygenation significantly worsened in the two groups assigned to receive high fluid balance, irrespective of the mechanical power received. All four groups had similar lung weights (i.e., lung edema), lung wet-to-dry ratios, and pathological variables. Animals with higher fluid balance developed more ascites, which was associated with a decrease in end-expiratory lung gas volume. Conclusions: Our study did not detect a significant difference in lung injury between high and low mechanical power. Some damage is directly attributable to mechanical power, while additional injury appears to result indirectly from high fluid balance, which reduces end-expiratory lung gas volume, with ascites playing an important role in this process.
- Open Access
- 23 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7084
Does the Intensity of Therapy Correspond to the Severity of Acute Respiratory Distress Syndrome (ARDS)?
Objectives: The intensity of respiratory treatment in acute respiratory distress syndrome (ARDS) is traditionally adjusted based on oxygenation severity, as defined by the mild, moderate, and severe Berlin classifications. However, ventilator-induced lung injury (VILI) is primarily determined by ventilator settings, namely tidal volume, respiratory rate, and positive end-expiratory pressure (PEEP). All these variables, along with respiratory elastance, are included in the concept of mechanical power. The aim of this study is to investigate whether applied mechanical power is proportional to oxygenation severity. Methods: We analyzed 291 ARDS patients (71 mild, 155 moderate, and 65 severe). We defined low, middle, and high mechanical power by dividing the entire population into tertiles with a similar number of patients. In each oxygenation class, we measured computed tomography (CT) anatomy, gas exchange, respiratory mechanics, mechanical power, and mortality rate. Results: ARDS severity was proportional to lung anatomy impairment, as defined by quantitative CT scans (i.e., lung volume and well-aerated tissue decreased across the ARDS classes, while respiratory elastance increased, as did mortality). Mechanical power, however, was similarly distributed across the severity classes, as the decrease in tidal volume in severe ARDS was offset by an increase in respiratory rate. Within each ARDS class, mortality increased from low to high mechanical power (roughly 1% for each J/min increase). Conclusions: Both lung severity and mechanical power independently impact mortality rates. It is tempting to speculate that ARDS severity primarily reflects the natural course of the disease, while mechanical power primarily reflects the risk of VILI.
- 23 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7084
Open AccessDoes the Intensity of Therapy Correspond to the Severity of Acute Respiratory Distress Syndrome (ARDS)?
Objectives: The intensity of respiratory treatment in acute respiratory distress syndrome (ARDS) is traditionally adjusted based on oxygenation severity, as defined by the mild, moderate, and severe Berlin classifications. However, ventilator-induced lung injury (VILI) is primarily determined by ventilator settings, namely tidal volume, respiratory rate, and positive end-expiratory pressure (PEEP). All these variables, along with respiratory elastance, are included in the concept of mechanical power. The aim of this study is to investigate whether applied mechanical power is proportional to oxygenation severity. Methods: We analyzed 291 ARDS patients (71 mild, 155 moderate, and 65 severe). We defined low, middle, and high mechanical power by dividing the entire population into tertiles with a similar number of patients. In each oxygenation class, we measured computed tomography (CT) anatomy, gas exchange, respiratory mechanics, mechanical power, and mortality rate. Results: ARDS severity was proportional to lung anatomy impairment, as defined by quantitative CT scans (i.e., lung volume and well-aerated tissue decreased across the ARDS classes, while respiratory elastance increased, as did mortality). Mechanical power, however, was similarly distributed across the severity classes, as the decrease in tidal volume in severe ARDS was offset by an increase in respiratory rate. Within each ARDS class, mortality increased from low to high mechanical power (roughly 1% for each J/min increase). Conclusions: Both lung severity and mechanical power independently impact mortality rates. It is tempting to speculate that ARDS severity primarily reflects the natural course of the disease, while mechanical power primarily reflects the risk of VILI.
- 15 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (12) , 1510-1513
Electrical Impedance Tomography: A Monitoring Tool for Ventilation-induced Lung Injury
- 15 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (12) , 1510-1513
Electrical Impedance Tomography: A Monitoring Tool for Ventilation-induced Lung Injury
- Open Access
- 1 April 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 136 (4) , 966-976
Quantifying pH-induced changes in plasma strong ion difference during experimental acidosis: clinical implications for base excess interpretation
This paper challenges the assumed equivalence between changes in plasma strong ion difference (SID) and whole blood base excess (BE) during in vitro acidosis. We highlight that redistribution of strong ions, in the form of albumin ionic-binding and transerythrocyte shifts, alters SID without affecting BE. We demonstrate that these expected SID alterations are predictable from albumin and hemoglobin’s charges, or from the noncarbonic whole blood buffer value, allowing a better interpretation of SID and BE during in vitro acidosis.
- 1 April 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 136 (4) , 966-976
Open AccessQuantifying pH-induced changes in plasma strong ion difference during experimental acidosis: clinical implications for base excess interpretation
This paper challenges the assumed equivalence between changes in plasma strong ion difference (SID) and whole blood base excess (BE) during in vitro acidosis. We highlight that redistribution of strong ions, in the form of albumin ionic-binding and transerythrocyte shifts, alters SID without affecting BE. We demonstrate that these expected SID alterations are predictable from albumin and hemoglobin’s charges, or from the noncarbonic whole blood buffer value, allowing a better interpretation of SID and BE during in vitro acidosis.
- 1 September 2023
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 140 (2) , 251-260
Causes of Hypoxemia in COVID-19 Acute Respiratory Distress Syndrome: A Combined Multiple Inert Gas Elimination Technique and Dual-energy Computed Tomography Study
Background: Despite the fervent scientific effort, a state-of-the art assessment of the different causes of hypoxemia (shunt, ventilation–perfusion mismatch, and diffusion limitation) in COVID-19 acute respiratory distress syndrome (ARDS) is currently lacking. In this study, the authors hypothesized a multifactorial genesis of hypoxemia and aimed to measure the relative contribution of each of the different mechanism and their relationship with the distribution of tissue and blood within the lung. Methods: In this cross-sectional study, the authors prospectively enrolled 10 patients with COVID-19 ARDS who had been intubated for less than 7 days. The multiple inert gas elimination technique (MIGET) and a dual-energy computed tomography (DECT) were performed and quantitatively analyzed for both tissue and blood volume. Variables related to the respiratory mechanics and invasive hemodynamics (PiCCO [Getinge, Sweden]) were also recorded. Results: The sample (51 ± 15 yr; Pao 2/Fio 2, 172 ± 86 mmHg) had a mortality of 50%. The MIGET showed a shunt of 25 ± 16% and a dead space of 53 ± 11%. Ventilation and perfusion were mismatched (LogSD, Q, 0.86 ± 0.33). Unexpectedly, evidence of diffusion limitation or postpulmonary shunting was also found. In the well aerated regions, the blood volume was in excess compared to the tissue, while the opposite happened in the atelectasis. Shunt was proportional to the blood volume of the atelectasis (R2 = 0.70, P = 0.003). mismatch was correlated with the blood volume of the poorly aerated tissue (R2 = 0.54, P = 0.016). The overperfusion coefficient was related to Pao 2/Fio 2 (R2 = 0.66, P = 0.002), excess tissue mass (R2 = 0.84, P < 0.001), and Etco 2/Paco 2 (R2 = 0.63, P = 0.004). Conclusions: These data support the hypothesis of a highly multifactorial genesis of hypoxemia. Moreover, recent evidence from post-mortem studies (i.e., opening of intrapulmonary bronchopulmonary anastomosis) may explain the findings regarding the postpulmonary shunting. The hyperperfusion might be related to the disease severity.
- 1 September 2023
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 140 (2) , 251-260
Causes of Hypoxemia in COVID-19 Acute Respiratory Distress Syndrome: A Combined Multiple Inert Gas Elimination Technique and Dual-energy Computed Tomography Study
Background: Despite the fervent scientific effort, a state-of-the art assessment of the different causes of hypoxemia (shunt, ventilation–perfusion mismatch, and diffusion limitation) in COVID-19 acute respiratory distress syndrome (ARDS) is currently lacking. In this study, the authors hypothesized a multifactorial genesis of hypoxemia and aimed to measure the relative contribution of each of the different mechanism and their relationship with the distribution of tissue and blood within the lung. Methods: In this cross-sectional study, the authors prospectively enrolled 10 patients with COVID-19 ARDS who had been intubated for less than 7 days. The multiple inert gas elimination technique (MIGET) and a dual-energy computed tomography (DECT) were performed and quantitatively analyzed for both tissue and blood volume. Variables related to the respiratory mechanics and invasive hemodynamics (PiCCO [Getinge, Sweden]) were also recorded. Results: The sample (51 ± 15 yr; Pao 2/Fio 2, 172 ± 86 mmHg) had a mortality of 50%. The MIGET showed a shunt of 25 ± 16% and a dead space of 53 ± 11%. Ventilation and perfusion were mismatched (LogSD, Q, 0.86 ± 0.33). Unexpectedly, evidence of diffusion limitation or postpulmonary shunting was also found. In the well aerated regions, the blood volume was in excess compared to the tissue, while the opposite happened in the atelectasis. Shunt was proportional to the blood volume of the atelectasis (R2 = 0.70, P = 0.003). mismatch was correlated with the blood volume of the poorly aerated tissue (R2 = 0.54, P = 0.016). The overperfusion coefficient was related to Pao 2/Fio 2 (R2 = 0.66, P = 0.002), excess tissue mass (R2 = 0.84, P < 0.001), and Etco 2/Paco 2 (R2 = 0.63, P = 0.004). Conclusions: These data support the hypothesis of a highly multifactorial genesis of hypoxemia. Moreover, recent evidence from post-mortem studies (i.e., opening of intrapulmonary bronchopulmonary anastomosis) may explain the findings regarding the postpulmonary shunting. The hyperperfusion might be related to the disease severity.
- Open Access
- 1 August 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 135 (2) , 334-342
Gas volume corrections in intensive care unit: needed or pointless?
The conditions of temperature, pressure, and saturation in which respiratory gas volumes are expressed [standard temperature and pressure, dry (STPD), ambient temperature and pressure, saturated (ATPS), or body temperature and pressure, saturated (BTPS)] are physiologically relevant, but often ignored or unknown in clinical practice. In this study, we aimed to investigate whether and at which extent the gas volume corrections, either in natural or artificial lung, may alter key respiratory and metabolic variables and the possible clinical consequences. We primarily referred to the effects of gas volume corrections on three physiological variables: physiological dead space, venous admixture, and total CO2 production (V(over dot)CO2) during extracorporeal support. We used three physiological models in which calculations of these variables have been performed with and without correction of gas volumes, both in a theoretical model and in 448 patients. The lack of gas volume correction leads to an error in the computation of physiological dead space fraction between 0.05 and 0.15, both in the theoretical model and in the patient population. The venous admixture was minimally affected by the absence of correction (0.01-0.04 error). During extracorporeal support, if the V(over dot)CO2 of natural and membrane lung is expressed in different conditions, potentially large errors (0%-18.4%) may occur in the computation of total V(over dot)CO2 (V(over dot)CO2tot = V(over dot)CO2ML + V(over dot)CO2NL). This may lead to inappropriate settings of mechanical ventilation with higher plateau pressure. As the dead space and the CO2 sharing between natural and artificial lung are relevant both as prognostic index and as a guide for appropriate mechanical ventilation, their inappropriate computation may lead to erroneous categorization of the patients and inappropriate mechanical treatment. NEW & NOTEWORTHY Gas volume conditions are often ignored or unknown in the clinical practice. However, they could have relevance for the calculation of some key variables in ICU setting. This study shows that gas volume corrections are mostly relevant when assessing CO2 clearance, both in mechanical ventilation and during extracorporeal support, whereas irrelevant for oxygenation assessment of patients. Knowing when the appropriate corrections are needed allows to better understand patients' clinical conditions and to tailor the treatment.
- 1 August 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 135 (2) , 334-342
Open AccessGas volume corrections in intensive care unit: needed or pointless?
The conditions of temperature, pressure, and saturation in which respiratory gas volumes are expressed [standard temperature and pressure, dry (STPD), ambient temperature and pressure, saturated (ATPS), or body temperature and pressure, saturated (BTPS)] are physiologically relevant, but often ignored or unknown in clinical practice. In this study, we aimed to investigate whether and at which extent the gas volume corrections, either in natural or artificial lung, may alter key respiratory and metabolic variables and the possible clinical consequences. We primarily referred to the effects of gas volume corrections on three physiological variables: physiological dead space, venous admixture, and total CO2 production (V(over dot)CO2) during extracorporeal support. We used three physiological models in which calculations of these variables have been performed with and without correction of gas volumes, both in a theoretical model and in 448 patients. The lack of gas volume correction leads to an error in the computation of physiological dead space fraction between 0.05 and 0.15, both in the theoretical model and in the patient population. The venous admixture was minimally affected by the absence of correction (0.01-0.04 error). During extracorporeal support, if the V(over dot)CO2 of natural and membrane lung is expressed in different conditions, potentially large errors (0%-18.4%) may occur in the computation of total V(over dot)CO2 (V(over dot)CO2tot = V(over dot)CO2ML + V(over dot)CO2NL). This may lead to inappropriate settings of mechanical ventilation with higher plateau pressure. As the dead space and the CO2 sharing between natural and artificial lung are relevant both as prognostic index and as a guide for appropriate mechanical ventilation, their inappropriate computation may lead to erroneous categorization of the patients and inappropriate mechanical treatment. NEW & NOTEWORTHY Gas volume conditions are often ignored or unknown in the clinical practice. However, they could have relevance for the calculation of some key variables in ICU setting. This study shows that gas volume corrections are mostly relevant when assessing CO2 clearance, both in mechanical ventilation and during extracorporeal support, whereas irrelevant for oxygenation assessment of patients. Knowing when the appropriate corrections are needed allows to better understand patients' clinical conditions and to tailor the treatment.
- Open Access
- 1 May 2023
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 207 (9) , 1183-1193
High- versus Low-Flow Extracorporeal Respiratory Support in Experimental Hypoxemic Acute Lung Injury
Rationale: In the EOLIA (ECMO to Rescue Lung Injury in Severe ARDS) trial, oxygenation was similar between intervention and conventional groups, whereas V˙ e was reduced in the intervention group. Comparable reductions in ventilation intensity are theoretically possible with low-flow extracorporeal CO2 removal (ECCO2R), provided oxygenation remains acceptable. Objectives: To compare the effects of ECCO2R and extracorporeal membrane oxygenation (ECMO) on gas exchange, respiratory mechanics, and hemodynamics in animal models of pulmonary (intratracheal hydrochloric acid) and extrapulmonary (intravenous oleic acid) lung injury. Methods: Twenty-four pigs with moderate to severe hypoxemia (PaO2:Fi O2 ≤ 150 mm Hg) were randomized to ECMO (blood flow 50–60 ml/kg/min), ECCO2R (0.4 L/min), or mechanical ventilation alone. Measurements and Main Results: V ˙ o 2, V˙ co 2, gas exchange, hemodynamics, and respiratory mechanics were measured and are presented as 24-hour averages. Oleic acid versus hydrochloric acid showed higher extravascular lung water (1,424 ± 419 vs. 574 ± 195 ml; P < 0.001), worse oxygenation (PaO2:Fi O2 = 125 ± 14 vs. 151 ± 11 mm Hg; P < 0.001), but better respiratory mechanics (plateau pressure 27 ± 4 vs. 30 ± 3 cm H2O; P = 0.017). Both models led to acute severe pulmonary hypertension. In both models, ECMO (3.7 ± 0.5 L/min), compared with ECCO2R (0.4 L/min), increased mixed venous oxygen saturation and oxygenation, and improved hemodynamics (cardiac output = 6.0 ± 1.4 vs. 5.2 ± 1.4 L/min; P = 0.003). V˙ o 2 and V˙ co 2, irrespective of lung injury model, were lower during ECMO, resulting in lower PaCO2 and V˙ e but worse respiratory elastance compared with ECCO2R (64 ± 27 vs. 40 ± 8 cm H2O/L; P < 0.001). Conclusions: ECMO was associated with better oxygenation, lower V˙ o 2, and better hemodynamics. ECCO2R may offer a potential alternative to ECMO, but there are concerns regarding its effects on hemodynamics and pulmonary hypertension.
- 1 May 2023
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 207 (9) , 1183-1193
Open AccessHigh- versus Low-Flow Extracorporeal Respiratory Support in Experimental Hypoxemic Acute Lung Injury
Rationale: In the EOLIA (ECMO to Rescue Lung Injury in Severe ARDS) trial, oxygenation was similar between intervention and conventional groups, whereas V˙ e was reduced in the intervention group. Comparable reductions in ventilation intensity are theoretically possible with low-flow extracorporeal CO2 removal (ECCO2R), provided oxygenation remains acceptable. Objectives: To compare the effects of ECCO2R and extracorporeal membrane oxygenation (ECMO) on gas exchange, respiratory mechanics, and hemodynamics in animal models of pulmonary (intratracheal hydrochloric acid) and extrapulmonary (intravenous oleic acid) lung injury. Methods: Twenty-four pigs with moderate to severe hypoxemia (PaO2:Fi O2 ≤ 150 mm Hg) were randomized to ECMO (blood flow 50–60 ml/kg/min), ECCO2R (0.4 L/min), or mechanical ventilation alone. Measurements and Main Results: V ˙ o 2, V˙ co 2, gas exchange, hemodynamics, and respiratory mechanics were measured and are presented as 24-hour averages. Oleic acid versus hydrochloric acid showed higher extravascular lung water (1,424 ± 419 vs. 574 ± 195 ml; P < 0.001), worse oxygenation (PaO2:Fi O2 = 125 ± 14 vs. 151 ± 11 mm Hg; P < 0.001), but better respiratory mechanics (plateau pressure 27 ± 4 vs. 30 ± 3 cm H2O; P = 0.017). Both models led to acute severe pulmonary hypertension. In both models, ECMO (3.7 ± 0.5 L/min), compared with ECCO2R (0.4 L/min), increased mixed venous oxygen saturation and oxygenation, and improved hemodynamics (cardiac output = 6.0 ± 1.4 vs. 5.2 ± 1.4 L/min; P = 0.003). V˙ o 2 and V˙ co 2, irrespective of lung injury model, were lower during ECMO, resulting in lower PaCO2 and V˙ e but worse respiratory elastance compared with ECCO2R (64 ± 27 vs. 40 ± 8 cm H2O/L; P < 0.001). Conclusions: ECMO was associated with better oxygenation, lower V˙ o 2, and better hemodynamics. ECCO2R may offer a potential alternative to ECMO, but there are concerns regarding its effects on hemodynamics and pulmonary hypertension.
- 2 December 2022
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 130 (3) , 360-367
Ventilatory ratio, dead space, and venous admixture in patients with acute respiratory distress syndrome
- 2 December 2022
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 130 (3) , 360-367
Ventilatory ratio, dead space, and venous admixture in patients with acute respiratory distress syndrome