Ingmar Fleps
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ingmar Fleps has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Benedikt Helgason
Institute for Biomechanics, ETH-Zürich, Zürich, Switzerland
10 shared publicationsStephen J. Ferguson
The Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
9 shared publicationsPierre Guy
Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
6 shared publications- Halldor Palsson
Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, School of Engineering and Natural Sciences, University of Iceland, Reykjavik, Iceland
4 shared publications Peter A Cripton
Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
3 shared publicationsPeter A. Cripton
Orthopaedic and Injury Biomechanics Group, School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada
3 shared publications
Latest Publications
- 1 September 2022
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 20 (5) , 309-319
A Review of CT-Based Fracture Risk Assessment with Finite Element Modeling and Machine Learning
Purpose of Review We reviewed advances over the past 3 years in assessment of fracture risk based on CT scans, considering methods that use finite element models, machine learning, or a combination of both. Recent Findings Several studies have demonstrated that CT-based assessment of fracture risk, using finite element modeling or biomarkers derived from machine learning, is equivalent to currently used clinical tools. Phantomless calibration of CT scans for bone mineral density enables accurate measurements from routinely taken scans. This opportunistic use of CT scans for fracture risk assessment is facilitated by high-quality automated segmentation with deep learning, enabling workflows that do not require user intervention. Modeling of more realistic and diverse loading conditions, as well as improved modeling of fracture mechanisms, has shown promise to enhance our understanding of fracture processes and improve the assessment of fracture risk beyond the performance of current clinical tools. Summary CT-based screening for fracture risk is effective and, by analyzing scans that were taken for other indications, could be used to expand the pool of people screened, therefore improving fracture prevention. Finite element modeling and machine learning both provide valuable tools for fracture risk assessment. Future approaches should focus on including more loading-related aspects of fracture risk.
- 1 September 2022
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 20 (5) , 309-319
A Review of CT-Based Fracture Risk Assessment with Finite Element Modeling and Machine Learning
Purpose of Review We reviewed advances over the past 3 years in assessment of fracture risk based on CT scans, considering methods that use finite element models, machine learning, or a combination of both. Recent Findings Several studies have demonstrated that CT-based assessment of fracture risk, using finite element modeling or biomarkers derived from machine learning, is equivalent to currently used clinical tools. Phantomless calibration of CT scans for bone mineral density enables accurate measurements from routinely taken scans. This opportunistic use of CT scans for fracture risk assessment is facilitated by high-quality automated segmentation with deep learning, enabling workflows that do not require user intervention. Modeling of more realistic and diverse loading conditions, as well as improved modeling of fracture mechanisms, has shown promise to enhance our understanding of fracture processes and improve the assessment of fracture risk beyond the performance of current clinical tools. Summary CT-based screening for fracture risk is effective and, by analyzing scans that were taken for other indications, could be used to expand the pool of people screened, therefore improving fracture prevention. Finite element modeling and machine learning both provide valuable tools for fracture risk assessment. Future approaches should focus on including more loading-related aspects of fracture risk.
- 3 May 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 11 (2) , 253-265
Fast and robust femur segmentation from computed tomography images for patient-specific hip fracture risk screening
Osteoporosis is a common bone disease that increases the risk of bone fracture. Hip-fracture risk screening methods based on flnite element analysis depend on segmented computed tomography (CT) images; however, current femur segmentation methods require manual delineations of large data sets. Here we propose a deep neural network for fully automated, accurate, and fast segmentation of the proximal femur from CT. Evaluation on a set of 1147 proximal femurs with ground truth segmentations demonstrates that our method is apt for hip-fracture risk screening, bringing us one step closer to a clinically viable option for screening at-risk patients for hip-fracture susceptibility.
- 3 May 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 11 (2) , 253-265
Fast and robust femur segmentation from computed tomography images for patient-specific hip fracture risk screening
Osteoporosis is a common bone disease that increases the risk of bone fracture. Hip-fracture risk screening methods based on flnite element analysis depend on segmented computed tomography (CT) images; however, current femur segmentation methods require manual delineations of large data sets. Here we propose a deep neural network for fully automated, accurate, and fast segmentation of the proximal femur from CT. Evaluation on a set of 1147 proximal femurs with ground truth segmentations demonstrates that our method is apt for hip-fracture risk screening, bringing us one step closer to a clinically viable option for screening at-risk patients for hip-fracture susceptibility.
- Open Access
- 7 February 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (3) , 278-290
The Influence of Fall Direction and Hip Protector on Fracture Risk: FE Model Predictions Driven by Experimental Data
Hip fractures in older adults, which often lead to lasting impairments and an increased risk of mortality, are a major public health concern. Hip fracture risk is multi-factorial, affected by the risk of falling, the load acting on the femur, and the load the femur can withstand. This study investigates the influence of impact direction on hip fracture risk and hip protector efficacy. We simulated falls for 4 subjects, in 7 different impact directions (15° and 30° anterior, lateral, and 15°, 30°, 60°, and 90° posterior) at two different impact velocities (2.1 and 3.1 m/s), all with and without hip protector, using previously validated biofidelic finite element models. We found the highest number of fractures and highest fragility ratios in lateral and 15° posterior impacts. The hip protector attenuated femur forces by 23–49 % for slim subjects under impact directions that resulted in fractures (30° anterior to 30° posterior). The hip protector prevented all fractures (6/6) for 2.1 m/s impacts, but only 10% of fractures for 3.1 m/s impacts. Our results provide evidence that, regarding hip fracture risk, posterior-lateral impacts are as dangerous as lateral impacts, and they support the efficacy of soft-shell hip protectors for anterior- and posterior-lateral impacts.
- 7 February 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (3) , 278-290
Open AccessThe Influence of Fall Direction and Hip Protector on Fracture Risk: FE Model Predictions Driven by Experimental Data
Hip fractures in older adults, which often lead to lasting impairments and an increased risk of mortality, are a major public health concern. Hip fracture risk is multi-factorial, affected by the risk of falling, the load acting on the femur, and the load the femur can withstand. This study investigates the influence of impact direction on hip fracture risk and hip protector efficacy. We simulated falls for 4 subjects, in 7 different impact directions (15° and 30° anterior, lateral, and 15°, 30°, 60°, and 90° posterior) at two different impact velocities (2.1 and 3.1 m/s), all with and without hip protector, using previously validated biofidelic finite element models. We found the highest number of fractures and highest fragility ratios in lateral and 15° posterior impacts. The hip protector attenuated femur forces by 23–49 % for slim subjects under impact directions that resulted in fractures (30° anterior to 30° posterior). The hip protector prevented all fractures (6/6) for 2.1 m/s impacts, but only 10% of fractures for 3.1 m/s impacts. Our results provide evidence that, regarding hip fracture risk, posterior-lateral impacts are as dangerous as lateral impacts, and they support the efficacy of soft-shell hip protectors for anterior- and posterior-lateral impacts.
- Open Access
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 104957
Prophylactic augmentation implants in the proximal femur for hip fracture prevention: An in silico investigation of simulated sideways fall impacts
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 104957
Open AccessProphylactic augmentation implants in the proximal femur for hip fracture prevention: An in silico investigation of simulated sideways fall impacts
- Open Access
- 1 December 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 112, 104085
Implicit and explicit finite element models predict the mechanical response of calcium phosphate-titanium cranial implants
- 1 December 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 112, 104085
Open AccessImplicit and explicit finite element models predict the mechanical response of calcium phosphate-titanium cranial implants
- Open Access
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103866
Empirical relationships between bone density and ultimate strength: A literature review
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103866
Open AccessEmpirical relationships between bone density and ultimate strength: A literature review
- 4 June 2019
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 34 (10) , 1837-1850
Explicit Finite Element Models Accurately Predict Subject-Specific and Velocity-Dependent Kinetics of Sideways Fall Impact
The majority of hip fractures in the elderly are the result of a fall from standing or from a lower height. Current injury models focus mostly on femur strength while neglecting subject‐specific loading. This article presents an injury modelling strategy for hip fractures related to sideways falls that takes subject‐specific impact loading into account. Finite element models (FEMs) of the human body were used to predict the experienced load and the femoral strength in a single model. We validated these models for their predicted peak force, effective pelvic stiffness, and fracture status against matching ex vivo sideways fall impacts (N=11) with a trochanter velocity of 3.1 m/s. Furthermore, they were compared to sideways impacts of volunteers with lower impact velocities that were previously conducted by another group. Good agreement was found between the ex vivo experiments and the FEMs with respect to peak force (RMSE=10.7 %, R2=0.85) and effective pelvic stiffness (R2=0.92, RMSE=12.9 %). The FEMs were predictive for the fracture status of ten out of elven specimens. Compared to the volunteer experiments from low height, the FEMs overestimated the peak force by 25% for low BMI subjects and 8% for high BMI subjects. The effective pelvic stiffness values that were derived from the FEMs were comparable to those derived from impacts with volunteers. The force attenuation from the impact surface to the femur ranged between 27‐54% and was highly dependent on soft tissue thickness (R2=0.86). The energy balance in the FEMS showed that at the time of peak force 79 – 93 % of the total energy is either kinetic or was transformed to soft tissue deformation. The presented FEMs allow for direct discrimination between fracture and non‐fracture outcome for sideways falls and bridge the gap between impact testing with volunteers and impact conditions representative of real life falls.
- 4 June 2019
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 34 (10) , 1837-1850
Explicit Finite Element Models Accurately Predict Subject-Specific and Velocity-Dependent Kinetics of Sideways Fall Impact
The majority of hip fractures in the elderly are the result of a fall from standing or from a lower height. Current injury models focus mostly on femur strength while neglecting subject‐specific loading. This article presents an injury modelling strategy for hip fractures related to sideways falls that takes subject‐specific impact loading into account. Finite element models (FEMs) of the human body were used to predict the experienced load and the femoral strength in a single model. We validated these models for their predicted peak force, effective pelvic stiffness, and fracture status against matching ex vivo sideways fall impacts (N=11) with a trochanter velocity of 3.1 m/s. Furthermore, they were compared to sideways impacts of volunteers with lower impact velocities that were previously conducted by another group. Good agreement was found between the ex vivo experiments and the FEMs with respect to peak force (RMSE=10.7 %, R2=0.85) and effective pelvic stiffness (R2=0.92, RMSE=12.9 %). The FEMs were predictive for the fracture status of ten out of elven specimens. Compared to the volunteer experiments from low height, the FEMs overestimated the peak force by 25% for low BMI subjects and 8% for high BMI subjects. The effective pelvic stiffness values that were derived from the FEMs were comparable to those derived from impacts with volunteers. The force attenuation from the impact surface to the femur ranged between 27‐54% and was highly dependent on soft tissue thickness (R2=0.86). The energy balance in the FEMS showed that at the time of peak force 79 – 93 % of the total energy is either kinetic or was transformed to soft tissue deformation. The presented FEMs allow for direct discrimination between fracture and non‐fracture outcome for sideways falls and bridge the gap between impact testing with volunteers and impact conditions representative of real life falls.