Raul Carneiro Martins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Raul Carneiro Martins has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Cruz Serra
Instituto de Telecomunicações and Department of Electrical and Computer Engineering, Instituto Superior Técnico, Technical University of Lisbon, IST, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal
12 shared publications - Miguel Felizardo
Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10, Km 139.7, 2695-066 Loures, Portugal
12 shared publications - Jose Gonçalves Marques
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2695-066 Bobadela, Portugal
10 shared publications - Thomas A. Girard
University of Lisbon
10 shared publications - Ana Rita Ramos
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2695-066 Bobadela, Portugal
9 shared publications - T. Morlat
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2695-066 Bobadela, Portugal
8 shared publications
Latest Publications
- Open Access
- 4 February 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (1) , 151-163
Mineralization of Sialoliths Investigated by Ex Vivo and In Vivo X-ray Computed Tomography
The fraction of organic matter present affects the fragmentation behavior of sialoliths; thus, pretherapeutic information on the degree of mineralization is relevant for a correct selection of lithotripsy procedures. This work proposes a methodology for in vivo characterization of salivary calculi in the pretherapeutic context. Sialoliths were characterized in detail by X-ray computed microtomography (μCT) in combination with atomic emission spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Correlative analysis of the same specimens was performed by in vivo and ex vivo helical computed tomography (HCT) and ex vivo μCT. The mineral matter in the sialoliths consisted essentially of apatite (89 vol%) and whitlockite (11 vol%) with average density of 1.8 g/cm3. In hydrated conditions, the mineral mass prevailed with 53 ± 13 wt%, whereas the organic matter, with a density of 1.2 g/cm3, occupied 65 ± 10% of the sialoliths’ volume. A quantitative relation between sialoliths mineral density and X-ray attenuation is proposed for both HCT and μCT.
- 4 February 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (1) , 151-163
Open AccessMineralization of Sialoliths Investigated by Ex Vivo and In Vivo X-ray Computed Tomography
The fraction of organic matter present affects the fragmentation behavior of sialoliths; thus, pretherapeutic information on the degree of mineralization is relevant for a correct selection of lithotripsy procedures. This work proposes a methodology for in vivo characterization of salivary calculi in the pretherapeutic context. Sialoliths were characterized in detail by X-ray computed microtomography (μCT) in combination with atomic emission spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Correlative analysis of the same specimens was performed by in vivo and ex vivo helical computed tomography (HCT) and ex vivo μCT. The mineral matter in the sialoliths consisted essentially of apatite (89 vol%) and whitlockite (11 vol%) with average density of 1.8 g/cm3. In hydrated conditions, the mineral mass prevailed with 53 ± 13 wt%, whereas the organic matter, with a density of 1.2 g/cm3, occupied 65 ± 10% of the sialoliths’ volume. A quantitative relation between sialoliths mineral density and X-ray attenuation is proposed for both HCT and μCT.
- 1 June 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 115 (1) , 20-32
BIT: Biosignal Igniter Toolkit
- 1 June 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 115 (1) , 20-32
BIT: Biosignal Igniter Toolkit
- Open Access
- 6 September 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 459
Non-contact wearable single forearm cardiac biopotential acquisition device
- 6 September 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 459
Open AccessNon-contact wearable single forearm cardiac biopotential acquisition device
- 1 September 2013
- Published by Elsevier in Astroparticle Physics
- Vol. 49, 28-43
Fabrication and response of high concentration SIMPLE superheated droplet detectors with different liquids
- 1 September 2013
- Published by Elsevier in Astroparticle Physics
- Vol. 49, 28-43
Fabrication and response of high concentration SIMPLE superheated droplet detectors with different liquids
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 6239-6242
A new image reconstruction algorithm for real-time monitoring of conductivity and permeability changes in Magnetic Induction Tomography
A linear image reconstruction algorithm for solving the Magnetic Induction Tomography inverse problem is presented. It's an optimization process to determine a reconstruction matrix that does the best mapping between a set of training parameter vectors and their respective measurements dictated by a forward model. It allows the simultaneous 3D reconstructions of the electric conductivity, electric permittivity and magnetic permeability. The results were compared with the ones obtained from a single-step regularized Gauss-Newton method and a reduction of 15% in the image error was verified. The behavior of the developed algorithm in a simulated clinical environment was also assessed using a realistic bio-impedance model of the human head, derived from a high resolution magnetic resonance image.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 6239-6242
A new image reconstruction algorithm for real-time monitoring of conductivity and permeability changes in Magnetic Induction Tomography
A linear image reconstruction algorithm for solving the Magnetic Induction Tomography inverse problem is presented. It's an optimization process to determine a reconstruction matrix that does the best mapping between a set of training parameter vectors and their respective measurements dictated by a forward model. It allows the simultaneous 3D reconstructions of the electric conductivity, electric permittivity and magnetic permeability. The results were compared with the ones obtained from a single-step regularized Gauss-Newton method and a reduction of 15% in the image error was verified. The behavior of the developed algorithm in a simulated clinical environment was also assessed using a realistic bio-impedance model of the human head, derived from a high resolution magnetic resonance image.
- 22 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (12) , 4707-4712
An Optimized Forward Problem Solver for the Complete Characterization of the Electromagnetic Properties of Biological Tissues in Magnetic Induction Tomography
A new method for solving the magnetic induction tomography forward problem is presented. It is based on the combination of an OcTree type multi-level adaptive orthogonal mesh generation algorithm with a conformal finite integration technique-like formulation. The results obtained were compared with both analytical solutions and the response from a previously validated method. The presented method was proven to be capable of dealing with both complex electrical conductivity and magnetic permeability, giving a response with a low relative error, even when fairly coarse grids are used, thus reducing the overall system size and consequently the time for the attainment of the solution. This method is shown to be sensitive enough to be useful for image reconstruction in biological applications, where very small conductivities and relative permeabilities are usually found.
- 22 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (12) , 4707-4712
An Optimized Forward Problem Solver for the Complete Characterization of the Electromagnetic Properties of Biological Tissues in Magnetic Induction Tomography
A new method for solving the magnetic induction tomography forward problem is presented. It is based on the combination of an OcTree type multi-level adaptive orthogonal mesh generation algorithm with a conformal finite integration technique-like formulation. The results obtained were compared with both analytical solutions and the response from a previously validated method. The presented method was proven to be capable of dealing with both complex electrical conductivity and magnetic permeability, giving a response with a low relative error, even when fairly coarse grids are used, thus reducing the overall system size and consequently the time for the attainment of the solution. This method is shown to be sensitive enough to be useful for image reconstruction in biological applications, where very small conductivities and relative permeabilities are usually found.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A differential high-resolution motorized multi-projection approach for an experimental Magnetic Induction Tomography prototype
In this paper, the first experimental results for a multi-projection differential coil Magnetic Induction Tomography system are presented. All current systems are static, allowing only the acquisition of a small number of fixed projections. The presented setup provides a much higher density of projection measurements which reduces the ill-posedness of the inverse problem. This is further enhanced through the use of a topview camera to detect the external frontiers of the object. The experimental setup is based on a previously presented design and consists of a geometrically centered excitation and four pairs of anti-series differential coils equally spaced at 45°. Simulation and experimental results for 3D phantom structures are shown.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A differential high-resolution motorized multi-projection approach for an experimental Magnetic Induction Tomography prototype
In this paper, the first experimental results for a multi-projection differential coil Magnetic Induction Tomography system are presented. All current systems are static, allowing only the acquisition of a small number of fixed projections. The presented setup provides a much higher density of projection measurements which reduces the ill-posedness of the inverse problem. This is further enhanced through the use of a topview camera to detect the external frontiers of the object. The experimental setup is based on a previously presented design and consists of a geometrically centered excitation and four pairs of anti-series differential coils equally spaced at 45°. Simulation and experimental results for 3D phantom structures are shown.
- 14 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 21 (6) , 3004-3016
An Alternating Direction Algorithm for Total Variation Reconstruction of Distributed Parameters
Augmented Lagrangian variational formulations and alternating optimization have been adopted to solve distributed parameter estimation problems. The alternating direction method of multipliers (ADMM) is one of such formulations/optimization methods. Very recently, the number of applications of the ADMM, or variants of it, to solve inverse problems in image and signal processing has increased at an exponential rate. The reason for this interest is that ADMM decomposes a difficult optimization problem into a sequence of much simpler problems. In this paper, we use the ADMM to reconstruct piecewise-smooth distributed parameters of elliptical partial differential equations from noisy and linear (blurred) observations of the underlying field. The distributed parameters are estimated by solving an inverse problem with total variation (TV) regularization. The proposed instance of the ADMM solves, in each iteration, an and a decoupled optimization problems. An operator splitting is used to simplify the treatment of the TV regularizer, avoiding its smooth approximation and yielding a simple yet effective ADMM reconstruction method compared with previously proposed approaches. The competitiveness of the proposed method, with respect to the state-of-the-art, is illustrated in simulated 1-D and 2-D elliptical equation problems, which are representative of many real applications.
- 14 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 21 (6) , 3004-3016
An Alternating Direction Algorithm for Total Variation Reconstruction of Distributed Parameters
Augmented Lagrangian variational formulations and alternating optimization have been adopted to solve distributed parameter estimation problems. The alternating direction method of multipliers (ADMM) is one of such formulations/optimization methods. Very recently, the number of applications of the ADMM, or variants of it, to solve inverse problems in image and signal processing has increased at an exponential rate. The reason for this interest is that ADMM decomposes a difficult optimization problem into a sequence of much simpler problems. In this paper, we use the ADMM to reconstruct piecewise-smooth distributed parameters of elliptical partial differential equations from noisy and linear (blurred) observations of the underlying field. The distributed parameters are estimated by solving an inverse problem with total variation (TV) regularization. The proposed instance of the ADMM solves, in each iteration, an and a decoupled optimization problems. An operator splitting is used to simplify the treatment of the TV regularizer, avoiding its smooth approximation and yielding a simple yet effective ADMM reconstruction method compared with previously proposed approaches. The competitiveness of the proposed method, with respect to the state-of-the-art, is illustrated in simulated 1-D and 2-D elliptical equation problems, which are representative of many real applications.
- 1 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A modified Hilbert-Huang algorithm to the assessment of heart rate variability
Heart rate variability is a classical method to quantify the autonomic outflow to the cardiovascular system. The current methods in frequency and time-frequency domains have shown some limitations in resolution. In this paper, we propose a modified Hilbert-Huang algorithm to the assessment of autonomic activity in heart rate signals. These approaches are evaluated while analyzing both simulated signals and experimental data from tachograms associated with cardiac autonomic blockade of patients with paroxysmal atrial fibrillation.
- 1 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A modified Hilbert-Huang algorithm to the assessment of heart rate variability
Heart rate variability is a classical method to quantify the autonomic outflow to the cardiovascular system. The current methods in frequency and time-frequency domains have shown some limitations in resolution. In this paper, we propose a modified Hilbert-Huang algorithm to the assessment of autonomic activity in heart rate signals. These approaches are evaluated while analyzing both simulated signals and experimental data from tachograms associated with cardiac autonomic blockade of patients with paroxysmal atrial fibrillation.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 503-506
High-performance groundless EEG/ECG capacitive electrodes
An improved non-contact and groundless EEG/ECG biopotential acquisition system is presented. The system consists in a set of capacitive electrodes and a feedback electronic circuit that provides a way to build an appropriate electronic common, quashing the need for a ground electrode. The circuit also implements a dynamic interference rejection using feedback to control the amount of probed noise that is subtracted. This allows for the capability to provide direct interference canceling, mitigating the mains noise, both 50 Hz/60 Hz and harmonics. We further delve into the design of the electrodes and its impact on the sensitivity, spatial selectivity and distance attenuation.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 503-506
High-performance groundless EEG/ECG capacitive electrodes
An improved non-contact and groundless EEG/ECG biopotential acquisition system is presented. The system consists in a set of capacitive electrodes and a feedback electronic circuit that provides a way to build an appropriate electronic common, quashing the need for a ground electrode. The circuit also implements a dynamic interference rejection using feedback to control the amount of probed noise that is subtracted. This allows for the capability to provide direct interference canceling, mitigating the mains noise, both 50 Hz/60 Hz and harmonics. We further delve into the design of the electrodes and its impact on the sensitivity, spatial selectivity and distance attenuation.