SSSusana Santo

Susana Santo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Susana Santo has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines

    by Susana Santo, Diogo Ayres‐De‐Campos, Cristina Costa‐Santos, William Schnettler, Austin Ugwumadu, Luís M. Da Graça, the FM‐Compare Collaboration

    Introduction: One of the limitations reported with cardiotocography is the modest interobserver agreement observed in tracing interpretation. This study compared agreement, reliability and accuracy of cardiotocography interpretation using the International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines.Material and methods: A total of 151 tracings were evaluated by 27 clinicians from three centers where International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines were routinely used. Interobserver agreement was evaluated using the proportions of agreement and reliability with the κ statistic. The accuracy of tracings classified as “pathological/category III” was assessed for prediction of newborn acidemia. For all measures, 95% confidence interval were calculated.Results: Cardiotocography classifications were more distributed with International Federation of Gynecology and Obstetrics (9, 52, 39%) and National Institute for Health and Care Excellence (30, 33, 37%) than with American College of Obstetrics and Gynecology (13, 81, 6%). The category with the highest agreement was American College of Obstetrics and Gynecology category II (proportions of agreement = 0.73, 95% confidence interval 0.70–76), and the ones with the lowest agreement were American College of Obstetrics and Gynecology categories I and III. Reliability was significantly higher with International Federation of Gynecology and Obstetrics (κ = 0.37, 95% confidence interval 0.31–0.43), and National Institute for Health and Care Excellence (κ = 0.33, 95% confidence interval 0.28–0.39) than with American College of Obstetrics and Gynecology (κ = 0.15, 95% confidence interval 0.10–0.21); however, all represent only slight/fair reliability. International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence showed a trend towards higher sensitivities in prediction of newborn acidemia (89 and 97%, respectively) than American College of Obstetrics and Gynecology (32%), but the latter achieved a significantly higher specificity (95%).Conclusions: With American College of Obstetrics and Gynecology guidelines there is high agreement in category II, low reliability, low sensitivity and high specificity in prediction of acidemia. With International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence guidelines there is higher reliability, a trend towards higher sensitivity, and lower specificity in prediction of acidemia.


  • Fetal bronchopulmonary malformations

    by Carla Nunes, Isabel Pereira, Cláudia Araújo, Susana Ferreira Santo, Rui Marques Carvalho, Antonieta Melo, Luís Mendes Graça

    Fetal body tumors are rare, but the ability to diagnose them has improved over recent years. Most masses discovered in the chest results from fetal bronchopulmonary malformations, such as congenital cystic adenomatoid malformation and bronchopulmonary sequestration. Congenital cystic adenomatoid malformation and bronchopulmonary sequestration have a reported incidence of 50% and 33% of all prenatally diagnosed lung lesions, respectively. Retrospective analysis of the congenital cystic adenomatoid malformation and bronchopulmonary sequestration cases diagnosed or surveilled at our department, between January 2003 and March 2013. Prenatal examination, evolution, management and patient outcome were analyzed. A total of 918 fetal malformations were diagnosed at our hospital, 17 of them representing fetal bronchopulmonary malformations. The majority were diagnosed during the second trimester and stabilized or regressed during the third trimester of pregnancy. The pregnancies and deliveries had no other relevant findings or complications, except in three cases. Nine children required surgery. All of the children are healthy and have a normal development, with regular surveillance by the pediatricians. The majority of these fetal lung masses are isolated findings that partially regress during intrauterine life. With adequate postnatal surveillance and eventual surgery the prognosis is good.


  • Top Cited Papers

    Counseling in fetal medicine: agenesis of the corpus callosum

    by S. Santo, F. D'ANtonio, T. Homfray, P. Rich, G. Pilu, A. Bhide, B. Thilaganathan, A. T. Papageorghiou

    In this Review, we aim to provide up‐to‐date and evidence‐based answers to common questions regarding the diagnosis and prognosis of prenatally detected agenesis of the corpus callosum (ACC). A systematic literature search was performed to identify all reports of ACC and reference lists of articles were identified. ACC involves partial or complete absence of the main commissural pathway that connects the two cerebral hemispheres, and can be isolated (with no other abnormalities) or complex (coexisting with other abnormalities). It is a rare finding and the prevalence is difficult to estimate because of selection bias in reported series. The corpus callosum (CC) can be assessed on ultrasound by direct visualization, but indirect features, such as ventriculomegaly, absence of the cavum septi pellucidi or widening of interhemispheric fissure, are often the reason for detection in a screening population. Careful imaging in a center with a high level of expertise is required to make a full assessment and to exclude coexisting abnormalities, which occur in about 46% of fetuses. When available, magnetic resonance imaging appears to be an important adjunct as it allows direct visualization. It can reduce false‐positive rates on ultrasound and can confirm ACC, it can assess whether this is complete or partial and it can help in detecting coexisting brain abnormalities not seen on ultrasound. The overall rate of chromosomal abnormality in fetuses with ACC is 18%, but this high rate includes both isolated and complex ACC; more recent studies suggest that chromosomal abnormalities are rare in isolated cases. Nevertheless, postnatal follow‐up studies suggest that about 15% of cases thought to be isolated prenatally were found to have associated abnormalities after birth. Neurodevelopmental outcome in isolated ACC was recently reported in a systematic review and suggested normal outcome in about 65–75% of cases. Findings need to be considered in light of the several limitations of existing studies, in terms of study design, selection bias, varying definitions and imaging protocols, ascertainment bias and lack of control groups. These uncertainties mean that antenatal counseling is difficult and further large prospective studies are needed.


  • Human factors affecting the interpretation of fetal heart rate tracings

    by Susana Santo, Diogo Ayres-De-Campos

    Human factors can have an important impact on cardiotocography (CTG) interpretation and management decisions, and therefore may directly affect obstetrical outcomes. It has been well demonstrated that there is wide observer disagreement over CTG interpretation, particularly in the evaluation of variability, decelerations, and overall tracing classification. The reasons behind this are still incompletely understood, but poor reproducibility can have a profound impact on the technology's accuracy and on its efficacy. Some scientific societies have recently revised their guidelines for CTG interpretation, but no up-to-date universally accepted recommendation exists. In spite of some approximation between the major guideline sets, important differences still exist between them, and they remain complex and prone to memory decay. Regular training in CTG interpretation appears to result in increased knowledge, better observer agreement, and improved quality of care. Computer analysis has also been developed, but remains heavily dependent on staff to confirm interpretation and to decide clinical management. An international consensus, comprising simpler and more objective interpretation guidelines, together with regular staff training, and improved decision support systems seem to be the way forward for this technology.


  • Maternal and neonatal immediate effects of sequential delivery

    by Sónia Barata, Edite Cardoso, Susana Ferreira Santo, Nuno Clode, Luis Mendes Graça

    Objective: To evaluate the immediate maternal and neonatal outcomes associated with sequential instrumental delivery (vaccum plus forceps) compared with the use of one instrument only (forceps or vaccum). Study design: A longitudinal observational study was carried out, including all instrumental deliveries performed in term singleton pregnancies, in vertex presentation, at station level 0 or +1. According to the type of the instruments, the deliveries were divided in three groups: the vaccum group, the forceps group and the sequential group. Immediate maternal and neonatal outcomes were evaluated. Results: A total of 275 instrumental deliveries were performed: 126 (45.5%) vaccum assisted deliveries, 62 (22.6%) forceps assisted deliveries and 87 (31.6%) sequential deliveries. Regarding maternal morbidity, there was a significant difference between the three groups (p < 0.001), with a higher rate of complications in the sequential group. The type of instrument was the only factor associated with significant maternal morbidity. The rate of immediate neonatal morbidity was 4.4% and there was no significant association with the instrument type or with other identifiable factors. Conclusion: Sequential delivery is associated with a higher maternal morbidity and it seems not to increase neonatal morbidity.


  • Open Access

    Prenatal diagnosis of non‐immune hydrops fetalis: what do we tell the parents?

    by Susana Santo, Sahar Mansour, Basky Thilaganathan, Tessa Homfray, Aris Papageorghiou, Sandra Calvert, Amar Bhide

    Objective: The aim of this study is to outline the aetiology and outcome of a series of fetuses with non‐immune hydrops (NIH), detected prenatally. The findings are compared with a comprehensive review of recent reports.Methods: This is a retrospective study reviewing all pregnancies complicated by NIH in the fetus and continued after 20 weeks of pregnancy over a period of 10 years. Outcome was obtained from postmortem reports, discharge summaries, communication with the clinicians or information from the parents. A literature search was also performed to identify all reports on NIH in the last 10 years.Results: Seventy‐one fetuses affected by NIH were included in this study. The aetiology of the NIH was identified prenatally in 40 cases. The most common causes of NIH were thoracic disorders, infections and cardiovascular disorders. Forty‐four of the 71 (62%) fetuses were live‐born. There were 10 neonatal deaths. Of the remaining 34 babies, 17 infants survived without morbidity.Conclusion: The survival rate of NIH is at least 48% in this study. Prenatal identification of the cause is possible in 56% of cases. The risk of neurodevelopmental delay in those that survive is 3 of 28 (11%). Copyright © 2011 John Wiley & Sons, Ltd.


  • Open Access

    Sensitivity of higher, lower and mean second‐trimester uterine artery Doppler resistance indices in screening for pre‐eclampsia

    by R. Napolitano, S. Santo, R. D'SOuza, A. Bhide, B. Thilaganathan

    Objectives: First‐trimester Doppler studies have reported that the lower uterine artery (UtA) resistance index (RI) is better for the prediction of pre‐eclampsia (PE) than is either the mean or higher indices. The aim of this study was to determine if this relationship is true in the second trimester.Methods: This was a retrospective study of 24 859 singleton pregnancies. During the study period second‐trimester UtA Doppler assessment was routinely available to all nulliparous women and to parous women at increased risk of PE. UtA‐RI was obtained at the time of the anomaly scan. Receiver–operating characteristics curves for the lower, mean and higher UtA‐RI for the prediction of PE were calculated.Results: There were 1037 cases of PE. There were significant associations between UtA‐RI and PE, the association being stronger for early and preterm than late or term PE. There was no significant difference in the strength of the association between lower, mean and higher RI with PE at any gestation.Conclusion: Performance of UtA‐RI in predicting PE is no different for the lower, higher or mean RI of the two UtAs. The most likely explanation for the discrepancy with first‐trimester studies is that the placental‐side effect on Doppler indices may change with advancing gestational age and progressive trophoblast development and invasion. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.


  • Labor Induction with 25-μg Misoprostol Vaginal Capsules

    by Susana Santo, Regina Lourenço, Mónica Centeno, Luísa Pargana, Nuno Clode, Helena Ferreira, Luís M. da Graça

    Aim: To evaluate the success rate and the safety profile of labor induction with a new misoprostol formulation – vaginal capsules of 25 μg of misoprostol. Methods: Labor induction was performed in 250 singleton term pregnancies; 149 (59.6%) were nulliparous. Vaginal capsules of 25 μg of misoprostol were placed in the posterior vaginal fornix every 6 h. Success rate, contractility and fetal heart rate abnormalities and fetal outcomes were evaluated. Results: The success rate of labor induction was 97.6%. The average number of vaginal administrations was 1.5. The mean interval between induction and active labor was 10 h and 20 min and the average length of labor was 15 h and 35 min. The cesarean section rate was 18.8%. There were 15 cases of tachysystole, 3 cases of hypertonus and 1 case of hyperstimulation syndrome. There were no adverse neonatal outcomes. Conclusions: This study allowed to conclude that labor induction with vaginal capsules of 25 μg of misoprostol is associated with an excellent success rate and safety profile.


  • Prenatal ultrasonographic diagnosis of abdominal cystic lymphangioma: A case report

    by Susana Santo, João Paulo Marques, Patrizia Veca, Antonieta Melo, Luís Mendes da Graça

    Abdominal lymphangioma is a rare tumor of the lymphatic vessels. A case of an abdominal cystic lymphangioma identified at 22 weeks of gestation is reported. Ultrasonographic monitoring showed a progressive increase of mass size during the gestation. Pregnancy was terminated at 38 weeks and the newborn was submitted to a laparotomy with resection of all cystic structures. At the present time the infant is three years old and is doing well.