Sarah S. Bawazir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarah S. Bawazir has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Ahsan Habib Khandoker
Department of Biomedical Engineering and Biotechnology Khalifa University Abu Dhabi United Arab Emirates
2 shared publications Cesare Stefanini
Khalifa University of Science and Technology
2 shared publications- Cesare Stefanini
Biomedical Engineering, Khalifa University, Abu Dhabi 127788, UAE
2 shared publications Aibobek Seitak
Department of Biomedical Engineering, Khalifa University, Abu Dhabi 127788, UAE
1 shared publication- Anna-Maria Pappa
Khalifa University of Science and Technology
1 shared publication Arianna Menciassi
The BioRobotics Institute of Scuola Superiore Sant’Anna
1 shared publication
Latest Publications
- Open Access
- 12 January 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (45) , 61435-61445
One-Pot Synthesis of a Robust Crosslinker-Free Thermo-Reversible Conducting Hydrogel Electrode for Epidermal Electronics
Traditional epidermal electrodes, typically made of silver/silver chloride (Ag/AgCl), have been widely used in various applications, including electrophysiological recordings and biosignal monitoring. However, they present limitations due to inherent material mismatches with the skin. This often results in high interface impedance, discomfort, and potential skin irritation, particularly during prolonged use or for individuals with sensitive skin. While various tissue-mimicking materials have been explored, their mechanical advantages often come at the expense of conductivity, resulting in low-quality recordings. We herein report the facile fabrication of conducting and stretchable hydrogels using a "one-pot" method. This approach involves the synthesis of a natural hydrogel, termed Golde, composed of abundant and eco-friendly components, including gelatin, chitosan, and glycerol. To enhance the conductivity of the hydrogel, various conducting materials, such as poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS), thermally reduced graphene (TRG), and MXene, are introduced. The resulting conducting hydrogels exhibit remarkable robustness, do not require crosslinkers, and possess a unique thermo-reversible property, simplifying the fabrication process and ensuring enhanced long-term stability. Moreover, their fabrication is sustainable, as it employs environmentally friendly materials and processes while retaining their skin-friendly characteristics. The resulting hydrogel electrodes were tested for electrocardiogram (ECG) signal acquisition and outperformed commercial electrodes even when implemented in an all-flexible electrode setup simply using copper tape, owing to their inherent adhesiveness.
- 12 January 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (45) , 61435-61445
Open AccessOne-Pot Synthesis of a Robust Crosslinker-Free Thermo-Reversible Conducting Hydrogel Electrode for Epidermal Electronics
Traditional epidermal electrodes, typically made of silver/silver chloride (Ag/AgCl), have been widely used in various applications, including electrophysiological recordings and biosignal monitoring. However, they present limitations due to inherent material mismatches with the skin. This often results in high interface impedance, discomfort, and potential skin irritation, particularly during prolonged use or for individuals with sensitive skin. While various tissue-mimicking materials have been explored, their mechanical advantages often come at the expense of conductivity, resulting in low-quality recordings. We herein report the facile fabrication of conducting and stretchable hydrogels using a "one-pot" method. This approach involves the synthesis of a natural hydrogel, termed Golde, composed of abundant and eco-friendly components, including gelatin, chitosan, and glycerol. To enhance the conductivity of the hydrogel, various conducting materials, such as poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS), thermally reduced graphene (TRG), and MXene, are introduced. The resulting conducting hydrogels exhibit remarkable robustness, do not require crosslinkers, and possess a unique thermo-reversible property, simplifying the fabrication process and ensuring enhanced long-term stability. Moreover, their fabrication is sustainable, as it employs environmentally friendly materials and processes while retaining their skin-friendly characteristics. The resulting hydrogel electrodes were tested for electrocardiogram (ECG) signal acquisition and outperformed commercial electrodes even when implemented in an all-flexible electrode setup simply using copper tape, owing to their inherent adhesiveness.
- Open Access
Polypyrrole/Agarose Hydrogel-Based Bladder Volume Sensor with a Resistor Ladder Structure
Chronic monitoring of bladder activity and urine volume is essential for patients suffering from urinary dysfunctions. However, due to the anatomy and dynamics of the bladder, chronic and precise monitoring of bladder activity remains a challenge. Here, we propose a new sensing mechanism that measures the bladder volume using a resistive ladder network with contact switches. Instead of measuring the impedance between the electrode continuously, the proposed sensor provides a digitized output (‘on’ or ‘off’) when the bladder volume reaches a certain threshold value. We present simple proof-of-concept sensors which compare the discrete-mode operation to the continuous-mode operation. In addition, by using multiple pairs of this contact-mode switch in a resistor ladder structure, we demonstrate monitoring of the bladder volume in four discrete steps using an idealized balloon and an ex vivo pig’s bladder. We implemented the resistive ladder network using a conductive polypyrrole/agarose hydrogel composite which exhibits a Young’s modulus comparable to that of the bladder wall. Compared to the continuous-mode operation, the proposed sensing mechanism is less susceptible to drift due to material degradation and environmental factors.
Open AccessPolypyrrole/Agarose Hydrogel-Based Bladder Volume Sensor with a Resistor Ladder Structure
Chronic monitoring of bladder activity and urine volume is essential for patients suffering from urinary dysfunctions. However, due to the anatomy and dynamics of the bladder, chronic and precise monitoring of bladder activity remains a challenge. Here, we propose a new sensing mechanism that measures the bladder volume using a resistive ladder network with contact switches. Instead of measuring the impedance between the electrode continuously, the proposed sensor provides a digitized output (‘on’ or ‘off’) when the bladder volume reaches a certain threshold value. We present simple proof-of-concept sensors which compare the discrete-mode operation to the continuous-mode operation. In addition, by using multiple pairs of this contact-mode switch in a resistor ladder structure, we demonstrate monitoring of the bladder volume in four discrete steps using an idealized balloon and an ex vivo pig’s bladder. We implemented the resistive ladder network using a conductive polypyrrole/agarose hydrogel composite which exhibits a Young’s modulus comparable to that of the bladder wall. Compared to the continuous-mode operation, the proposed sensing mechanism is less susceptible to drift due to material degradation and environmental factors.
- Open Access
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 26167-26174
Multiple Access for Visible Light Communications: Research Challenges and Future Trends
The ever-increasing demand of mobile Internet and multimedia services poses unique and significant challenges for current and future generation wireless networks. These challenges are mainly related to the support of massive ubiquitous connectivity, low latency and highly efficient utilization of spectrum resources. Therefore, it is of a paramount importance to address them in the design and deployment of future wireless networks. To this end, the present article provides a comprehensive overview of multiple access schemes in the context of visible light communications (VLC). Specifically, we initially provide a thorough overview of frequency domain multiple access techniques for single and multi-carrier systems, which is then followed by an in depth discussion on the technical considerations of optical code division multiple access techniques and their adoption in indoor VLC applications. Furthermore, we address space division multiple access and, finally, we revisit and analyze a new promising technology, namely, nonorthogonal multiple access (NOMA). It is shown that NOMA exhibits significant benefits in VLC systems that can outperform conventional multiple access schemes, rendering it a particularly effective solution. Furthermore, it is demonstrated that it can coexist with the above optical multiple access schemes, which can maximize the performance and efficiency of future VLC systems. However, it is also shown that the potential of NOMA in VLC systems requires efficient addressing of a series of related challenges and constraints, such as fast and effective successive interference cancellation techniques, compensation and mitigation of LED non-linearity and imperfect and/or outdated channel state information.
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 26167-26174
Open AccessMultiple Access for Visible Light Communications: Research Challenges and Future Trends
The ever-increasing demand of mobile Internet and multimedia services poses unique and significant challenges for current and future generation wireless networks. These challenges are mainly related to the support of massive ubiquitous connectivity, low latency and highly efficient utilization of spectrum resources. Therefore, it is of a paramount importance to address them in the design and deployment of future wireless networks. To this end, the present article provides a comprehensive overview of multiple access schemes in the context of visible light communications (VLC). Specifically, we initially provide a thorough overview of frequency domain multiple access techniques for single and multi-carrier systems, which is then followed by an in depth discussion on the technical considerations of optical code division multiple access techniques and their adoption in indoor VLC applications. Furthermore, we address space division multiple access and, finally, we revisit and analyze a new promising technology, namely, nonorthogonal multiple access (NOMA). It is shown that NOMA exhibits significant benefits in VLC systems that can outperform conventional multiple access schemes, rendering it a particularly effective solution. Furthermore, it is demonstrated that it can coexist with the above optical multiple access schemes, which can maximize the performance and efficiency of future VLC systems. However, it is also shown that the potential of NOMA in VLC systems requires efficient addressing of a series of related challenges and constraints, such as fast and effective successive interference cancellation techniques, compensation and mitigation of LED non-linearity and imperfect and/or outdated channel state information.
- 31 December 2017
- Published by Springer Nature
- p. 203-208
A Bionic Sphincter for Stress Urinary Incontinence: Design and Preliminary Experiments
- 31 December 2017
- Published by Springer Nature
- p. 203-208
A Bionic Sphincter for Stress Urinary Incontinence: Design and Preliminary Experiments
- 11 October 2017
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 45 (12) , 2717-2732
Implantable Systems for Stress Urinary Incontinence
Stress urinary incontinence (SUI), the involuntary urine leakage due to failure of the urethral closure mechanism, is a global health challenge with substantial human suffering and socioeconomic costs. Approximately 167 million male and female patients are predicted to suffer from SUI in 2018, worldwide. A wide range of surgical interventions are available for the treatment of SUI. Severe cases, however, usually require the implantation of artificial urinary sphincter devices. This review comparatively presents and analyzes the working principles, as well as the challenges, associated with the current implantable SUI systems in clinical use. These include slings, urethral bulking agents, artificial urinary sphincters, and adjustable continence devices. It further reports on recent research progress and state-of-the-art in the field of SUI implants, including an original approach proposed by the authors with a pressure feedback sensory mechanism. The new emerging field of artificial muscle devices, including electroactive polymers, provides a promising innovative solution for replacing the weakened urethral sphincter in SUI patients.
- 11 October 2017
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 45 (12) , 2717-2732
Implantable Systems for Stress Urinary Incontinence
Stress urinary incontinence (SUI), the involuntary urine leakage due to failure of the urethral closure mechanism, is a global health challenge with substantial human suffering and socioeconomic costs. Approximately 167 million male and female patients are predicted to suffer from SUI in 2018, worldwide. A wide range of surgical interventions are available for the treatment of SUI. Severe cases, however, usually require the implantation of artificial urinary sphincter devices. This review comparatively presents and analyzes the working principles, as well as the challenges, associated with the current implantable SUI systems in clinical use. These include slings, urethral bulking agents, artificial urinary sphincters, and adjustable continence devices. It further reports on recent research progress and state-of-the-art in the field of SUI implants, including an original approach proposed by the authors with a pressure feedback sensory mechanism. The new emerging field of artificial muscle devices, including electroactive polymers, provides a promising innovative solution for replacing the weakened urethral sphincter in SUI patients.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 1732-1735
Implantable bladder volume sensor based on resistor ladder network composed of conductive hydrogel composite
An accurate bladder volume monitoring system is a critical component in diagnosis and treatment of urological disorders. Here, we report an implantable bladder volume sensor with a multi-level resistor ladder which estimates the bladder volume through discrete resistance values. Discretization allows the sensor output to be resilient to the long-term drift, hysteresis, and degradation of the sensor materials. Our sensor is composed of biocompatible polypyrrole/agarose hydrogel composite. Because Young's modulus of this composite is comparable to that of the bladder wall, the effect of mechanical loading of the sensor on the bladder movement is minimized which allows more accurate volume monitoring. We also demonstrate the patterning and molding capability of this material by fabrication various structures. Lastly, we successfully demonstrate the functionality of the multi-level resistor ladder sensor as a bladder volume sensor by attaching the sensor on the pig's bladder and observing the impedance change of the sensor.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 1732-1735
Implantable bladder volume sensor based on resistor ladder network composed of conductive hydrogel composite
An accurate bladder volume monitoring system is a critical component in diagnosis and treatment of urological disorders. Here, we report an implantable bladder volume sensor with a multi-level resistor ladder which estimates the bladder volume through discrete resistance values. Discretization allows the sensor output to be resilient to the long-term drift, hysteresis, and degradation of the sensor materials. Our sensor is composed of biocompatible polypyrrole/agarose hydrogel composite. Because Young's modulus of this composite is comparable to that of the bladder wall, the effect of mechanical loading of the sensor on the bladder movement is minimized which allows more accurate volume monitoring. We also demonstrate the patterning and molding capability of this material by fabrication various structures. Lastly, we successfully demonstrate the functionality of the multi-level resistor ladder sensor as a bladder volume sensor by attaching the sensor on the pig's bladder and observing the impedance change of the sensor.