Fabian MülLer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fabian MülLer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Boris Eduardovich Malyugin
The Jules Stein Eye Institute, University of California at Los Angeles, 200 Stein Plaza, Los Angeles, CA 90095, USA
2 shared publications - A. V. Golovin
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow , Russian Federation
1 shared publication Bernau Werner
Ziemer Ophthalmic Systems, Port, Switzerland; and
1 shared publicationChristoph Schwab
1 shared publication- Farhad Hafezi
ELZA Institute, Zurich, Switzerland
1 shared publication Gerasimov Maksim
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia
1 shared publication
Latest Publications
- Open Access
- 31 March 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (1) , 200-206
Femtolaser Assisted Surgery of the First Stage of Keratoprosthesis. Results of the First Clinical Cases
Purpose: to evaluate the anatomical and clinical results of using femtosecond laser for cutting out an intrastromal pocket in a vascular leucoma during the first stage of keratoprosthesis.Patients and methods. This article is a retrospective analysis of 3 patients who underwent the first stage of keratoprosthesis the implantation of a keratoprosthesis supporting plate into an intrastromal pocket formed using femtosecond laser in the thickness of a vascular leucoma. After applanation of the laser handle to the patient’s cornea and previously known data on the thickness of the cornea, the intrastromal pocket was positioned at a depth of 2/3 of the vascular leucoma, then the femtosecond laser was activated and the intrastromal pocket was formed. After the laser work was completed, the intrastromal pocket was revised and the supporting plate was implanted.Results. When biomicroscopy and optical coherence tomography data measured the thickness of the cornea in the area above and below the supporting plate of the keratoprosthesis in the long-term postoperative period at a period of 6 months, in all three cases, we observe the stable position of keratoprosthesis supporting plate without any signs of protrusion and displacement. This fact made it possible to successfully perform the second stage of keratoprosthesis — installation of an optical cylinder.Conclusions. The use of a femtosecond laser at the first stage of keratoprosthesis is a possible, safe and faster method in keratoprosthetics of vascular leucoma in patients whom optical corneal transplantation or limbal stem cell transplantation are not indicated. This technology makes it possible to form an intrastromal pocket uniformly in the thickness of the vascular leucoma of the patient’s cornea without the need for transplantation of the keratoprosthetic complex, reducing the risks of protrusion of the keratoprosthetic supporting plate in the long-term postoperative period, which ultimately allows achieving a high functional result. In addition, the use of a femtosecond laser at the first stage of keratoprosthesis reduces the overall operation time and makes this technology available for widespread use in the clinic.
- 31 March 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (1) , 200-206
Open AccessFemtolaser Assisted Surgery of the First Stage of Keratoprosthesis. Results of the First Clinical Cases
Purpose: to evaluate the anatomical and clinical results of using femtosecond laser for cutting out an intrastromal pocket in a vascular leucoma during the first stage of keratoprosthesis.Patients and methods. This article is a retrospective analysis of 3 patients who underwent the first stage of keratoprosthesis the implantation of a keratoprosthesis supporting plate into an intrastromal pocket formed using femtosecond laser in the thickness of a vascular leucoma. After applanation of the laser handle to the patient’s cornea and previously known data on the thickness of the cornea, the intrastromal pocket was positioned at a depth of 2/3 of the vascular leucoma, then the femtosecond laser was activated and the intrastromal pocket was formed. After the laser work was completed, the intrastromal pocket was revised and the supporting plate was implanted.Results. When biomicroscopy and optical coherence tomography data measured the thickness of the cornea in the area above and below the supporting plate of the keratoprosthesis in the long-term postoperative period at a period of 6 months, in all three cases, we observe the stable position of keratoprosthesis supporting plate without any signs of protrusion and displacement. This fact made it possible to successfully perform the second stage of keratoprosthesis — installation of an optical cylinder.Conclusions. The use of a femtosecond laser at the first stage of keratoprosthesis is a possible, safe and faster method in keratoprosthetics of vascular leucoma in patients whom optical corneal transplantation or limbal stem cell transplantation are not indicated. This technology makes it possible to form an intrastromal pocket uniformly in the thickness of the vascular leucoma of the patient’s cornea without the need for transplantation of the keratoprosthetic complex, reducing the risks of protrusion of the keratoprosthetic supporting plate in the long-term postoperative period, which ultimately allows achieving a high functional result. In addition, the use of a femtosecond laser at the first stage of keratoprosthesis reduces the overall operation time and makes this technology available for widespread use in the clinic.
- 1 March 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (3) , 360-367
Femtosecond Laser-Assisted Graft Preparation and Implantation of Corneal Allogeneic Intrastromal Ring Segments for Corneal Ectasia: 1-Year Results
Purpose: To evaluate the outcomes of patients treated with corneal allogeneic intrastromal ring segments cut with femtosecond laser (Femto-CAIRS) without concomitant corneal crosslinking. Methods: Patients with keratoconus treated with Femto-CAIRS at the American University of Beirut Medical Center were included (May 2022–January 2023). A proprietary software program was developed on the femtosecond laser to cut allogeneic segments. Visual, refractive, tomographic, aberrometric, and epithelial data by anterior segment optical coherence tomography were measured at baseline and 1, 3, 6, and 12 months postoperatively. Results: 20 eyes of 15 patients were included and followed up for 12 months. The manifest refraction spherical equivalent and cylinder improved from −6.79 ± 4.9 diopter (D) and −4.25 ± 1.8 D to −1.88 ± 2.9 D (P < 0.001) and −2.64 ± 1.4 D (P = 0.01) 12 months postoperatively, respectively. 75% of eyes gained 3 or more corrected distance visual acuity lines, most of which (65%) gained 4 lines or more 12 months postoperatively. The maximum keratometry and vertical coma decreased by 5.2 D (P < 0.001) and 1 μm (P = 0.001), respectively, 3 months postoperatively and remained stable until 12 months. The largest anterior stromal elevation over the central 5-mm diameter decreased from 36.0 ± 18.2 μm preoperatively to 19.9 ± 9.25 μm at 1 week postoperatively (P < 0.001) and remained relatively stable. Epithelial thickness over the cone increased relative to baseline starting 1 month postoperatively and becoming stable after 6 months while the mean epithelial thickness central to the ring peaked at 1 month after which it decreased to reach a plateau at 6 months. Conclusions: The Femto-CAIRS procedure improves visual and tomographic parameters and allows repeatable and safe results with the possibility of customization for individualized management.
- 1 March 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (3) , 360-367
Femtosecond Laser-Assisted Graft Preparation and Implantation of Corneal Allogeneic Intrastromal Ring Segments for Corneal Ectasia: 1-Year Results
Purpose: To evaluate the outcomes of patients treated with corneal allogeneic intrastromal ring segments cut with femtosecond laser (Femto-CAIRS) without concomitant corneal crosslinking. Methods: Patients with keratoconus treated with Femto-CAIRS at the American University of Beirut Medical Center were included (May 2022–January 2023). A proprietary software program was developed on the femtosecond laser to cut allogeneic segments. Visual, refractive, tomographic, aberrometric, and epithelial data by anterior segment optical coherence tomography were measured at baseline and 1, 3, 6, and 12 months postoperatively. Results: 20 eyes of 15 patients were included and followed up for 12 months. The manifest refraction spherical equivalent and cylinder improved from −6.79 ± 4.9 diopter (D) and −4.25 ± 1.8 D to −1.88 ± 2.9 D (P < 0.001) and −2.64 ± 1.4 D (P = 0.01) 12 months postoperatively, respectively. 75% of eyes gained 3 or more corrected distance visual acuity lines, most of which (65%) gained 4 lines or more 12 months postoperatively. The maximum keratometry and vertical coma decreased by 5.2 D (P < 0.001) and 1 μm (P = 0.001), respectively, 3 months postoperatively and remained stable until 12 months. The largest anterior stromal elevation over the central 5-mm diameter decreased from 36.0 ± 18.2 μm preoperatively to 19.9 ± 9.25 μm at 1 week postoperatively (P < 0.001) and remained relatively stable. Epithelial thickness over the cone increased relative to baseline starting 1 month postoperatively and becoming stable after 6 months while the mean epithelial thickness central to the ring peaked at 1 month after which it decreased to reach a plateau at 6 months. Conclusions: The Femto-CAIRS procedure improves visual and tomographic parameters and allows repeatable and safe results with the possibility of customization for individualized management.
- 27 August 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (2) , 262-270
Femtosecond Laser–Assisted Autologous Glueless Simple Limbal Epithelial Transplantation in Unilateral Limbal Stem Cell Deficiency: 12-Month Outcome of the First Clinical Cases
Purpose: Surgical treatment of unilateral limbal stem cell deficiency (LSCD) is based on limbal stem cell transplantation. Glueless simple limbal epithelial transplantation (G-SLET) technique implements several limbal micrografts harvested from the healthy eye of the same patient into the peripheral corneal tunnels without the use of fibrin glue and human amniotic membrane. Methods: A novel customized algorithm and software for a low-energy femtosecond laser (FSL) were developed and tested using 5 pairs of isolated porcine eyes. FSL-assisted G-SLET modification was assessed in 3 clinical cases of unilateral LSCD caused by chemical burns. Corneal epithelization efficacy, best-corrected visual acuity, corneal epithelial mapping, central corneal thickness, and impression cytology with immunohistochemical examination were evaluated. All patients were followed up for 12 months postoperatively. Results: The FSL set for 100% energy and the pattern of 8 nonpenetrating vertical cuts with oblique tunnel portions having variable incision depths and diameter of 8.5 mm and higher were selected for further clinical evaluation. Clinically, stable corneal epithelialization was achieved 2 to 3 weeks after intervention. At the 6-month follow-up, all patients had a healthy corneal epithelium with limbal micrografts visible inside the corneal tunnels. Best-corrected visual acuity markedly improved in 2 cases, but not in the third case with severe corneal stromal scarring. In addition, all patients noted a full-scale reduction in subjective complaints and substantial improvement in their quality of life. Conclusions: The FSL-assisted G-SLET is a new technique for autologous limbal stem cell transplantation in patients with unilateral LSCD. It allows the standardization of corneal tunnel localization and dimensions, thereby increasing the safety of the surgical procedure.
- 27 August 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (2) , 262-270
Femtosecond Laser–Assisted Autologous Glueless Simple Limbal Epithelial Transplantation in Unilateral Limbal Stem Cell Deficiency: 12-Month Outcome of the First Clinical Cases
Purpose: Surgical treatment of unilateral limbal stem cell deficiency (LSCD) is based on limbal stem cell transplantation. Glueless simple limbal epithelial transplantation (G-SLET) technique implements several limbal micrografts harvested from the healthy eye of the same patient into the peripheral corneal tunnels without the use of fibrin glue and human amniotic membrane. Methods: A novel customized algorithm and software for a low-energy femtosecond laser (FSL) were developed and tested using 5 pairs of isolated porcine eyes. FSL-assisted G-SLET modification was assessed in 3 clinical cases of unilateral LSCD caused by chemical burns. Corneal epithelization efficacy, best-corrected visual acuity, corneal epithelial mapping, central corneal thickness, and impression cytology with immunohistochemical examination were evaluated. All patients were followed up for 12 months postoperatively. Results: The FSL set for 100% energy and the pattern of 8 nonpenetrating vertical cuts with oblique tunnel portions having variable incision depths and diameter of 8.5 mm and higher were selected for further clinical evaluation. Clinically, stable corneal epithelialization was achieved 2 to 3 weeks after intervention. At the 6-month follow-up, all patients had a healthy corneal epithelium with limbal micrografts visible inside the corneal tunnels. Best-corrected visual acuity markedly improved in 2 cases, but not in the third case with severe corneal stromal scarring. In addition, all patients noted a full-scale reduction in subjective complaints and substantial improvement in their quality of life. Conclusions: The FSL-assisted G-SLET is a new technique for autologous limbal stem cell transplantation in patients with unilateral LSCD. It allows the standardization of corneal tunnel localization and dimensions, thereby increasing the safety of the surgical procedure.
- 1 August 2015
- Published by Elsevier in Journal of Computational and Applied Mathematics
- Vol. 283, 163-181
Finite Elements with mesh refinement for wave equations in polygons
- 1 August 2015
- Published by Elsevier in Journal of Computational and Applied Mathematics
- Vol. 283, 163-181
Finite Elements with mesh refinement for wave equations in polygons