Kyu Tae Hwang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kyu Tae Hwang has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Incheol Kook
Department of Orthopedic Surgery, Cheongju TOP Hospital, 1 Gyoseo-ro, Sangdang-gu, Cheongju 28546, Republic of Korea
7 shared publications Incheol Kook
Department of Orthopedic Surgery, Nowon Eulji Medical Center, Seoul, Republic of Korea
4 shared publicationsKi-Chul Park
Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea
4 shared publications- Ki-Chul Park
Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
4 shared publications Jin Kyu Lee
Department of Orthopaedic Surgery, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, Republic of Korea
3 shared publications- Chang-Nam Kang
Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul, Korea
2 shared publications
Latest Publications
- Open Access
- 19 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6405
Characteristics of the Extent and Onset of Osteonecrosis of the Femoral Head After Femoral Neck System (FNS) Fixation: A Minimum Two-Year Follow-Up Comparative Study with Cannulated Screws
Background/Objectives: This study aimed to compare the incidence, extent, and time to diagnosis of osteonecrosis of the femoral head (ONFH) between Femoral Neck System (FNS) and multiple cannulated screw (CS) fixation in patients with femoral neck fractures (FNFs) at a minimum follow-up of 24 months, as well as to identify factors associated with ONFH after FNS fixation. Methods: A retrospective cohort study was conducted at a single university hospital involving patients aged ≥18 years with isolated FNFs treated by closed reduction and internal fixation using either FNS or multiple CS. Reduction quality, fracture union, incidence and extent of ONFH (measured by Kerboul angle), and revision surgery due to ONFH or other causes were assessed as outcome measures. Logistic regression analyses were conducted to identify factors associated with ONFH after FNS fixation. Results: Eighty-seven patients were included, comprising 48 in the FNS group and 39 in the CS group. No significant differences were found between the groups in reduction quality, union rate, or time to union (p > 0.05 for all). The incidence of ONFH did not differ significantly between the FNS and CS groups (p = 0.314). However, the FNS group showed a significantly greater extent of ONFH (p = 0.031) and longer mean time to ONFH diagnosis (p = 0.001). No significant differences were observed in revision surgery rates due to ONFH (p = 1.000) or other causes (p = 0.624). Multivariate analysis identified fracture displacement (Garden classification stages III and IV) and poor reduction quality (“Broken S” by Lowell’s criteria) as significant predictors of ONFH after FNS fixation. Conclusions: ONFH following FNS fixation tended to exhibit a larger necrotic area and a delayed radiographic onset compared to CS fixation; however, the overall incidence and revision rates were comparable between implants. These differences may be due to initial fracture displacement and baseline severity, rather than the FNS implant itself. In the FNS group, the mean time to radiographic diagnosis of ONFH was 13.1 months, and initial fracture displacement and reduction quality were identified as risk factors for the development of ONFH following FNS fixation. Therefore, long-term and vigilant follow-up is essential after FNS fixation, particularly in patients with displaced fractures. Achieving optimal reduction quality and anatomical femoral neck alignment remains paramount to mitigating the risk of ONFH after FNS fixation.
- 19 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6405
Open AccessCharacteristics of the Extent and Onset of Osteonecrosis of the Femoral Head After Femoral Neck System (FNS) Fixation: A Minimum Two-Year Follow-Up Comparative Study with Cannulated Screws
Background/Objectives: This study aimed to compare the incidence, extent, and time to diagnosis of osteonecrosis of the femoral head (ONFH) between Femoral Neck System (FNS) and multiple cannulated screw (CS) fixation in patients with femoral neck fractures (FNFs) at a minimum follow-up of 24 months, as well as to identify factors associated with ONFH after FNS fixation. Methods: A retrospective cohort study was conducted at a single university hospital involving patients aged ≥18 years with isolated FNFs treated by closed reduction and internal fixation using either FNS or multiple CS. Reduction quality, fracture union, incidence and extent of ONFH (measured by Kerboul angle), and revision surgery due to ONFH or other causes were assessed as outcome measures. Logistic regression analyses were conducted to identify factors associated with ONFH after FNS fixation. Results: Eighty-seven patients were included, comprising 48 in the FNS group and 39 in the CS group. No significant differences were found between the groups in reduction quality, union rate, or time to union (p > 0.05 for all). The incidence of ONFH did not differ significantly between the FNS and CS groups (p = 0.314). However, the FNS group showed a significantly greater extent of ONFH (p = 0.031) and longer mean time to ONFH diagnosis (p = 0.001). No significant differences were observed in revision surgery rates due to ONFH (p = 1.000) or other causes (p = 0.624). Multivariate analysis identified fracture displacement (Garden classification stages III and IV) and poor reduction quality (“Broken S” by Lowell’s criteria) as significant predictors of ONFH after FNS fixation. Conclusions: ONFH following FNS fixation tended to exhibit a larger necrotic area and a delayed radiographic onset compared to CS fixation; however, the overall incidence and revision rates were comparable between implants. These differences may be due to initial fracture displacement and baseline severity, rather than the FNS implant itself. In the FNS group, the mean time to radiographic diagnosis of ONFH was 13.1 months, and initial fracture displacement and reduction quality were identified as risk factors for the development of ONFH following FNS fixation. Therefore, long-term and vigilant follow-up is essential after FNS fixation, particularly in patients with displaced fractures. Achieving optimal reduction quality and anatomical femoral neck alignment remains paramount to mitigating the risk of ONFH after FNS fixation.
- Open Access
Biomechanical Study of the Preventive Effect of Different Cephalomedullary Fixation Methods on the Occurrence of Femoral Neck Fractures in Osteoporotic Femurs
Background and Objectives: This study aimed to investigate the biomechanical properties of different cephalomedullary fixation methods for osteoporotic femurs using a synthetic bone model. Materials and Methods: Lateral impact tests and axial cyclic loading tests were performed, and each test was divided into three groups: group 1 with one reconstruction screw, group 2 with two reconstruction screws, and group 3 without cephalomedullary fixation. To simulate a healed femoral shaft fracture, no osteotomy was performed on the specimens. Results: Groups 1 and 2 had significantly higher mean stiffness, ultimate failure load, and energy to failure in the lateral impact test compared to the native synthetic femur (p < 0.001 for all), while group 3 had significantly lower values in all outcomes (p < 0.05 for all). Groups 1 and 2 showed significantly higher average number of cycles, total load to failure, and initial axial stiffness in the axial cyclic incremental loading test compared to the native synthetic femur (p < 0.001 for all), whereas group 3 showed a significantly lower mean number of cycles and total load to failure (p < 0.001 for all). Conclusions: Under the specific test conditions of this intact synthetic bone model, cephalomedullary fixation with one or two reconstruction screws demonstrated superior relative mechanical stability compared to standard interlocking nails. Using two reconstruction screws provided the greatest biomechanical resistance to failure. In cases where inserting two reconstruction screws is technically challenging or infeasible, a single reconstruction screw may offer an acceptable biomechanical alternative to help prevent peri-implant fractures in healed or prophylactic settings. Intramedullary nailing without cephalomedullary fixation exhibited the lowest mechanical performance, suggesting a potential biomechanical vulnerability to peri-implant fractures under these test conditions.
Open AccessBiomechanical Study of the Preventive Effect of Different Cephalomedullary Fixation Methods on the Occurrence of Femoral Neck Fractures in Osteoporotic Femurs
Background and Objectives: This study aimed to investigate the biomechanical properties of different cephalomedullary fixation methods for osteoporotic femurs using a synthetic bone model. Materials and Methods: Lateral impact tests and axial cyclic loading tests were performed, and each test was divided into three groups: group 1 with one reconstruction screw, group 2 with two reconstruction screws, and group 3 without cephalomedullary fixation. To simulate a healed femoral shaft fracture, no osteotomy was performed on the specimens. Results: Groups 1 and 2 had significantly higher mean stiffness, ultimate failure load, and energy to failure in the lateral impact test compared to the native synthetic femur (p < 0.001 for all), while group 3 had significantly lower values in all outcomes (p < 0.05 for all). Groups 1 and 2 showed significantly higher average number of cycles, total load to failure, and initial axial stiffness in the axial cyclic incremental loading test compared to the native synthetic femur (p < 0.001 for all), whereas group 3 showed a significantly lower mean number of cycles and total load to failure (p < 0.001 for all). Conclusions: Under the specific test conditions of this intact synthetic bone model, cephalomedullary fixation with one or two reconstruction screws demonstrated superior relative mechanical stability compared to standard interlocking nails. Using two reconstruction screws provided the greatest biomechanical resistance to failure. In cases where inserting two reconstruction screws is technically challenging or infeasible, a single reconstruction screw may offer an acceptable biomechanical alternative to help prevent peri-implant fractures in healed or prophylactic settings. Intramedullary nailing without cephalomedullary fixation exhibited the lowest mechanical performance, suggesting a potential biomechanical vulnerability to peri-implant fractures under these test conditions.
- Open Access
Biomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail
Background and Objectives: This biomechanical study aimed to compare the fixation stability of proximal fragments and assess the mechanical properties in models of unstable basicervical intertrochanteric fractures. Materials and Methods: Thirty-six synthetic femur models were utilized. After cephalomedullary nail insertion, unstable basicervical intertrochanteric fractures were created using an engraving machine. Specimens were divided into three groups based on the femoral head fixation method: Group 1 (n = 12, single 100 mm lag screw); Group 2 (n = 12, lag screw + 75 mm anti-rotation screw); and Group 3 (n = 12, lag screw + 95 mm anti-rotation screw). The anti-rotation screws were full-threaded locking screws positioned just below the lag screw. After applying 10,000 vertical cyclic loads, stereophotogrammetry was used to evaluate the proximal fragment rotation in three planes (coronal, sagittal, and axial), and screw-tip displacement was measured radiographically. Vertical load was then applied at a 10 mm/min rate until structural failure. Results: Rotational change in the sagittal plane was least in Group 3 (Group 1 = 1.7 ± 1.3°, Group 2 = 1.0 ± 0.8°, Group 3 = 0.6 ± 0.6°, p = 0.038). Varus (coronal plane) and retroversion (axial plane) collapse did not differ significantly among the three groups. While cranial migration showed no difference, axial migration was the significantly lowest in Group 3 (Group 1 = 1.07 ± 0.62 mm, Group 2 = 0.60 ± 0.57 mm, Group 3 = 0.50 ± 0.43 mm, p = 0.040). Failure load was slightly higher in Groups 2 and 3 than in Group 1, but without statistical significance. No significant differences were observed between Group 2 and Group 3 in any biomechanical outcomes. Conclusions: The novel cephalomedullary nail with a long inferior anti-rotation screw significantly reduced rotational instability and axial migration compared to a single-lag screw. There was no significant difference in the rotational stability between the 75 mm and 95 mm anti-rotation screw groups. This novel nail demonstrates superior biomechanical properties in this experimental model and warrants clinical evaluation for treating unstable basicervical intertrochanteric fractures.
Open AccessBiomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail
Background and Objectives: This biomechanical study aimed to compare the fixation stability of proximal fragments and assess the mechanical properties in models of unstable basicervical intertrochanteric fractures. Materials and Methods: Thirty-six synthetic femur models were utilized. After cephalomedullary nail insertion, unstable basicervical intertrochanteric fractures were created using an engraving machine. Specimens were divided into three groups based on the femoral head fixation method: Group 1 (n = 12, single 100 mm lag screw); Group 2 (n = 12, lag screw + 75 mm anti-rotation screw); and Group 3 (n = 12, lag screw + 95 mm anti-rotation screw). The anti-rotation screws were full-threaded locking screws positioned just below the lag screw. After applying 10,000 vertical cyclic loads, stereophotogrammetry was used to evaluate the proximal fragment rotation in three planes (coronal, sagittal, and axial), and screw-tip displacement was measured radiographically. Vertical load was then applied at a 10 mm/min rate until structural failure. Results: Rotational change in the sagittal plane was least in Group 3 (Group 1 = 1.7 ± 1.3°, Group 2 = 1.0 ± 0.8°, Group 3 = 0.6 ± 0.6°, p = 0.038). Varus (coronal plane) and retroversion (axial plane) collapse did not differ significantly among the three groups. While cranial migration showed no difference, axial migration was the significantly lowest in Group 3 (Group 1 = 1.07 ± 0.62 mm, Group 2 = 0.60 ± 0.57 mm, Group 3 = 0.50 ± 0.43 mm, p = 0.040). Failure load was slightly higher in Groups 2 and 3 than in Group 1, but without statistical significance. No significant differences were observed between Group 2 and Group 3 in any biomechanical outcomes. Conclusions: The novel cephalomedullary nail with a long inferior anti-rotation screw significantly reduced rotational instability and axial migration compared to a single-lag screw. There was no significant difference in the rotational stability between the 75 mm and 95 mm anti-rotation screw groups. This novel nail demonstrates superior biomechanical properties in this experimental model and warrants clinical evaluation for treating unstable basicervical intertrochanteric fractures.
- Open Access
- 2 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
The impact of medial-first dual plating for reduction of distal femoral fractures: a retrospective comparative cohort study
In dual-plate fixation of distal femoral fractures (DFF), reducing the relatively spared medial side first and using this metaphyseal-medial condylar segment as a template to reduce the lateral side may effectively facilitate reduction. This study evaluated the effectiveness of the medial-first dual-plate fixation in DFF. A retrospective study was conducted on 77 patients who underwent open reduction and internal fixation (ORIF) for DFF at a single institution between April 2012 and 2021. The patients were divided into a group in which medial-side ORIF was first performed followed by a lateral-ORIF (group M) and a lateral-ORIF only performed (group L). The demographic data, fracture classification, clinical outcomes, including operative time, estimated blood loss, complications, patient satisfaction, and pain level, and radiographic outcomes of the two groups were compared. There was no difference in the demographics or fracture classification between group M (n = 27) and group L (n = 50). The operative time was similar in the two groups. Group M had a significantly smaller articular gap, better union rate, shorter time to union, and stronger maintenance of coronal and sagittal alignment (P < 0.05). There were no significant differences in estimated blood loss, complications, reoperation rate, patient satisfaction, or pain level between the two groups. Medial-first dual-plate fixation showed better radiographic and comparable clinical results compared to lateral single-plate fixation in treating DFF. Medial-first dual-plate fixation facilitates the reduction and is believed to increase the reduction quality.
- 2 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessThe impact of medial-first dual plating for reduction of distal femoral fractures: a retrospective comparative cohort study
In dual-plate fixation of distal femoral fractures (DFF), reducing the relatively spared medial side first and using this metaphyseal-medial condylar segment as a template to reduce the lateral side may effectively facilitate reduction. This study evaluated the effectiveness of the medial-first dual-plate fixation in DFF. A retrospective study was conducted on 77 patients who underwent open reduction and internal fixation (ORIF) for DFF at a single institution between April 2012 and 2021. The patients were divided into a group in which medial-side ORIF was first performed followed by a lateral-ORIF (group M) and a lateral-ORIF only performed (group L). The demographic data, fracture classification, clinical outcomes, including operative time, estimated blood loss, complications, patient satisfaction, and pain level, and radiographic outcomes of the two groups were compared. There was no difference in the demographics or fracture classification between group M (n = 27) and group L (n = 50). The operative time was similar in the two groups. Group M had a significantly smaller articular gap, better union rate, shorter time to union, and stronger maintenance of coronal and sagittal alignment (P < 0.05). There were no significant differences in estimated blood loss, complications, reoperation rate, patient satisfaction, or pain level between the two groups. Medial-first dual-plate fixation showed better radiographic and comparable clinical results compared to lateral single-plate fixation in treating DFF. Medial-first dual-plate fixation facilitates the reduction and is believed to increase the reduction quality.
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 194-203
Does Hip Abduction during Intramedullary Nail Fixation Help Correct Residual Varus Alignment in Subtrochanteric Fractures? A Retrospective Cohort Study
Kook I, et al. Clin Orthop Surg. 2025 Apr;17(2):194-203. https://doi.org/10.4055/cios24271
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 194-203
Open AccessDoes Hip Abduction during Intramedullary Nail Fixation Help Correct Residual Varus Alignment in Subtrochanteric Fractures? A Retrospective Cohort Study
Kook I, et al. Clin Orthop Surg. 2025 Apr;17(2):194-203. https://doi.org/10.4055/cios24271
- 4 April 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 372-378
Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study
- 4 April 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 372-378
Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study
- Open Access
- 13 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
A retrospective cohort study of autogenous iliac strut bone grafting in large bone defects of the lower extremity
Autogenous iliac bone graft (AIBG) is the treatment of choice for managing bone defects, and favorable results have been reported for bone defects < 5 cm in length. In large bone defects ≥ 5 cm, it is difficult to obtain good results with simple bone grafting, and other management options have drawbacks, such as long immobilization periods and high complication rates. We hypothesized that AIBG in the strut form might show favorable results in large bone defects with minimal complications. This study aimed to investigate the outcomes of strut-type AIBG and evaluate its effectiveness compared to cancellous AIBG. This retrospective study included 50 patients who underwent AIBG for bone defects at a single institution between March 2011 and April 2020. We performed corticocancellous AIBG in a strut form to manage bone defects ≥ 5 cm in the lower extremities. The strut bone was harvested along the iliac crest and grafted slightly longer than the bone defect to apply a sufficient compressive force. Demographic information and radiographic and clinical results of patients who underwent strut AIBG (Group S) were analyzed. The outcomes of union, time to union, complications, and reoperation were compared with those of patients who underwent cancellous AIBG (Group C). The study population comprised 37 men (74%) and 13 women (26%), with a mean age of 50.0 (range: 19–78). The average follow-up period was 25.6 months (12–104 months). Group S included 16 patients with a mean bone defect length of 6.8 ± 1.2 cm. In Group S, union was achieved in all patients, with an average time to union of 6.7 months. Complications occurred in four cases, all related to wound problems. Group C comprised d 34 patients with a mean defect length of 2.8 ± 1.1 cm. Complications occurred in five patients in Group C, including four soft tissue problems and one implant failure. When comparing the outcomes of Groups S and C, no significant differences were observed. AIBG is an effective and safe technique for managing bone defects. Strut AIBG can be used effectively for bone defects ≥ 5 cm in the lower extremities.
- 13 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessA retrospective cohort study of autogenous iliac strut bone grafting in large bone defects of the lower extremity
Autogenous iliac bone graft (AIBG) is the treatment of choice for managing bone defects, and favorable results have been reported for bone defects < 5 cm in length. In large bone defects ≥ 5 cm, it is difficult to obtain good results with simple bone grafting, and other management options have drawbacks, such as long immobilization periods and high complication rates. We hypothesized that AIBG in the strut form might show favorable results in large bone defects with minimal complications. This study aimed to investigate the outcomes of strut-type AIBG and evaluate its effectiveness compared to cancellous AIBG. This retrospective study included 50 patients who underwent AIBG for bone defects at a single institution between March 2011 and April 2020. We performed corticocancellous AIBG in a strut form to manage bone defects ≥ 5 cm in the lower extremities. The strut bone was harvested along the iliac crest and grafted slightly longer than the bone defect to apply a sufficient compressive force. Demographic information and radiographic and clinical results of patients who underwent strut AIBG (Group S) were analyzed. The outcomes of union, time to union, complications, and reoperation were compared with those of patients who underwent cancellous AIBG (Group C). The study population comprised 37 men (74%) and 13 women (26%), with a mean age of 50.0 (range: 19–78). The average follow-up period was 25.6 months (12–104 months). Group S included 16 patients with a mean bone defect length of 6.8 ± 1.2 cm. In Group S, union was achieved in all patients, with an average time to union of 6.7 months. Complications occurred in four cases, all related to wound problems. Group C comprised d 34 patients with a mean defect length of 2.8 ± 1.1 cm. Complications occurred in five patients in Group C, including four soft tissue problems and one implant failure. When comparing the outcomes of Groups S and C, no significant differences were observed. AIBG is an effective and safe technique for managing bone defects. Strut AIBG can be used effectively for bone defects ≥ 5 cm in the lower extremities.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (3) , 160-167
Efficacy of Minimally Invasive Reduction With Cerclage Fixation in Spiral or Oblique Subtrochanteric Femoral Fractures: A Retrospective Cohort Study Comparing Cables and Wires
OBJECTIVES: To compare the outcomes of a minimally invasive reduction (MIR) technique using a cable and wire in spiral or oblique subtrochanteric femoral fractures (SFFs). METHODS: Design: Retrospective cohort study. Setting: Two University Hospitals. Patient Selection Criteria: Skeletally mature patients with spiral or oblique SFFs (OTA/AO 32A1 and 32A2) treated with intramedullary nailing and MIR with a cerclage wire passer using either a single-loop cable or cerclage wire or MIR without cable or wire between May 2016 and November 2021 were included. Outcome Measures and Comparisons: Coronal and sagittal interfragmentary gap, neck–shaft angle, coronal and sagittal angulation, fracture union, time to union, and Radiographic Union Score for Hip (RUSH) at 6 months post operation were compared. RESULTS: A total of 46 patients were included, with 16 each in the cable and wire groups and 14 in the non-wiring group. There were no differences in demographics (P > 0.05), fracture classification (P = 0.710), or operative data (P > 0.05) between the three groups. The cable group showed significantly better coronal (P = 0.003) and sagittal (P = 0.003) interfragmentary gap, shorter union time (P < 0.001), and higher 6-month RUSH score (P < 0.001) among the three groups. There were no significant differences in outcome measures between the wire and non-wiring groups (all P > 0.05). No mechanical complications or reoperations were observed in all three groups. CONCLUSIONS: Minimally invasive reduction using a cable is more effective than wire or non-wiring reduction to improve reduction quality and promote bone union in the SFFs. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (3) , 160-167
Efficacy of Minimally Invasive Reduction With Cerclage Fixation in Spiral or Oblique Subtrochanteric Femoral Fractures: A Retrospective Cohort Study Comparing Cables and Wires
OBJECTIVES: To compare the outcomes of a minimally invasive reduction (MIR) technique using a cable and wire in spiral or oblique subtrochanteric femoral fractures (SFFs). METHODS: Design: Retrospective cohort study. Setting: Two University Hospitals. Patient Selection Criteria: Skeletally mature patients with spiral or oblique SFFs (OTA/AO 32A1 and 32A2) treated with intramedullary nailing and MIR with a cerclage wire passer using either a single-loop cable or cerclage wire or MIR without cable or wire between May 2016 and November 2021 were included. Outcome Measures and Comparisons: Coronal and sagittal interfragmentary gap, neck–shaft angle, coronal and sagittal angulation, fracture union, time to union, and Radiographic Union Score for Hip (RUSH) at 6 months post operation were compared. RESULTS: A total of 46 patients were included, with 16 each in the cable and wire groups and 14 in the non-wiring group. There were no differences in demographics (P > 0.05), fracture classification (P = 0.710), or operative data (P > 0.05) between the three groups. The cable group showed significantly better coronal (P = 0.003) and sagittal (P = 0.003) interfragmentary gap, shorter union time (P < 0.001), and higher 6-month RUSH score (P < 0.001) among the three groups. There were no significant differences in outcome measures between the wire and non-wiring groups (all P > 0.05). No mechanical complications or reoperations were observed in all three groups. CONCLUSIONS: Minimally invasive reduction using a cable is more effective than wire or non-wiring reduction to improve reduction quality and promote bone union in the SFFs. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 January 2024
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 16 (2) , 184-193
Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study
Chung H, et al. Clin Orthop Surg. 2024 Apr;16(2):184-193. https://doi.org/10.4055/cios23190
- 1 January 2024
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 16 (2) , 184-193
Open AccessComparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study
Chung H, et al. Clin Orthop Surg. 2024 Apr;16(2):184-193. https://doi.org/10.4055/cios23190
- Open Access
- 28 June 2023
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 50 (05) , 523-528
Reconstruction of a Severe Open Tibiofibular Fracture using an Ipsilateral Vascularized Fractured Fibula with a Thoracodorsal Artery Perforator Free Flap
The Gustilo IIIB tibiofibular fractures often result in long bone loss and extensive soft tissue defects. Reconstruction of these complex wounds is very challenging, especially when it includes long bone grafts, because the donor site is limited. We describe our experience using a set of chimeric ipsilateral vascularized fibula grafts with a thoracodorsal artery perforator free flap to reconstruct the traumatic tibia defects. A 66-year-old male suffered a severe comminuted tibia fracture and segmented fibula fracture with large soft tissue defects as a result of a traffic accident. He also had an open calcaneal fracture with soft tissue defects on the ipsilateral side. All the main vessels of the lower extremity were intact, and the cortical bone defect of the tibia was almost as large as the fractured fibula segment. We used an ipsilateral vascularized fibula graft to reconstruct the tibia and a thoracodorsal artery perforator flap to resurface the soft tissue, using the distal ends of peroneal vessels as named into sequential chimeric flaps. After 3 weeks, the calcaneal defect was reconstructed with second thoracodorsal artery perforator free flap. Reconstruction was successful and allowed rapid rehabilitation because of reduced donor site morbidity.
- 28 June 2023
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 50 (05) , 523-528
Open AccessReconstruction of a Severe Open Tibiofibular Fracture using an Ipsilateral Vascularized Fractured Fibula with a Thoracodorsal Artery Perforator Free Flap
The Gustilo IIIB tibiofibular fractures often result in long bone loss and extensive soft tissue defects. Reconstruction of these complex wounds is very challenging, especially when it includes long bone grafts, because the donor site is limited. We describe our experience using a set of chimeric ipsilateral vascularized fibula grafts with a thoracodorsal artery perforator free flap to reconstruct the traumatic tibia defects. A 66-year-old male suffered a severe comminuted tibia fracture and segmented fibula fracture with large soft tissue defects as a result of a traffic accident. He also had an open calcaneal fracture with soft tissue defects on the ipsilateral side. All the main vessels of the lower extremity were intact, and the cortical bone defect of the tibia was almost as large as the fractured fibula segment. We used an ipsilateral vascularized fibula graft to reconstruct the tibia and a thoracodorsal artery perforator flap to resurface the soft tissue, using the distal ends of peroneal vessels as named into sequential chimeric flaps. After 3 weeks, the calcaneal defect was reconstructed with second thoracodorsal artery perforator free flap. Reconstruction was successful and allowed rapid rehabilitation because of reduced donor site morbidity.