Milton P. Macedo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Milton P. Macedo has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Manuel B. A. Correia
Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra, Portugal
15 shared publications - Alberto Blanco
Laboratory of Instrumentation and Experimental Particle Physics (LIP)
6 shared publications N. Carolino
Laboratorio de Instrumentacio e Fisica Exp. de Particulas, LIP, Coimbra
6 shared publications- Paulo Fonte
LIP -Laboratory of Instrumentation and Experimental Particle Physics Open Air Coimbra Portugal
6 shared publications - Ana Fernandes
Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
4 shared publications C. Gil
4 shared publications
Latest Publications
- Open Access
A Bimodal EMG/FMG System Using Machine Learning Techniques for Gesture Recognition Optimization
This study is part of a broader project, the Open Source Bionic Hand, which aims to develop and control, in real time, a low-cost 3D-printed bionic hand prototype using signals from the muscles of the forearm. This work is intended to implement a bimodal signal acquisition system, which uses EMG signals and Force Myography (FMG) in order to optimize the recognition of gesture intention and, consequently, the control of the bionic hand. The implementation of this bimodal EMG-FMG system will be described. It uses two different signals from BITalino EMG modules and Flexiforce™ sensors from Tekscan™. The dataset was built from thirty-six features extracted from each acquisition using two of each EMG and FMG sensors in extensor and flexor muscle groups simultaneously. The extraction of features is also depicted, as well as the subsequent use of these features to train and compare Machine Learning models in gesture recognition through MATLAB’s Classification Learner tool (v2.2.5 software). Preliminary results obtained from a dataset of three healthy volunteers show the effectiveness of this bimodal EMG/FMG system in the improvement of the efficacy on gesture recognition as it is shown, for example, for the Quadratic SVM classifier that raises from 75.00% with EMG signals to 87.96% using both signals.
Open AccessA Bimodal EMG/FMG System Using Machine Learning Techniques for Gesture Recognition Optimization
This study is part of a broader project, the Open Source Bionic Hand, which aims to develop and control, in real time, a low-cost 3D-printed bionic hand prototype using signals from the muscles of the forearm. This work is intended to implement a bimodal signal acquisition system, which uses EMG signals and Force Myography (FMG) in order to optimize the recognition of gesture intention and, consequently, the control of the bionic hand. The implementation of this bimodal EMG-FMG system will be described. It uses two different signals from BITalino EMG modules and Flexiforce™ sensors from Tekscan™. The dataset was built from thirty-six features extracted from each acquisition using two of each EMG and FMG sensors in extensor and flexor muscle groups simultaneously. The extraction of features is also depicted, as well as the subsequent use of these features to train and compare Machine Learning models in gesture recognition through MATLAB’s Classification Learner tool (v2.2.5 software). Preliminary results obtained from a dataset of three healthy volunteers show the effectiveness of this bimodal EMG/FMG system in the improvement of the efficacy on gesture recognition as it is shown, for example, for the Quadratic SVM classifier that raises from 75.00% with EMG signals to 87.96% using both signals.
- 16 March 2023
- Published by Springer Nature
- p. 26-39
A Low-Cost Open-Source Bionic Hand Controller: Preliminary Results and Perspectives
- 16 March 2023
- Published by Springer Nature
- p. 26-39
A Low-Cost Open-Source Bionic Hand Controller: Preliminary Results and Perspectives
- 14 December 2019
- Published by Springer Nature
- p. 3-14
Study of Mechanomyographic Alternatives to EMG Sensors for a Low-Cost Open Source Bionic Hand
- 14 December 2019
- Published by Springer Nature
- p. 3-14
Study of Mechanomyographic Alternatives to EMG Sensors for a Low-Cost Open Source Bionic Hand
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 3728-3731
A novel platform for distributed and remote real-time monitoring of animal model behavior in a bioterium
Animal models are an important resource in life sciences research; however, many of the procedures involving vivo models are complex and time consuming. A common problem while conducting experiments is observing the behavior of the models throughout their stay in the bioterium. Ideally, behavioral assessment should be frequent and rigorous, as a way of more accurately characterizing the animal model. However, to date, few suitable automated solutions can be found within the state-of-the-art. In this paper, we propose an autonomous platform for distributed behavioral data acquisition from individual animal habitats in bioteriums, with remote and online access to the data. This approach allows real-time observation of the status of the habitats, and retrieval of the logged data for post-processing. The work focuses on the use case of motion, temperature and water intake monitoring in small rodents, although the platform was designed to be general-purpose and extensible to other types of habitats and sensing configurations.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 3728-3731
A novel platform for distributed and remote real-time monitoring of animal model behavior in a bioterium
Animal models are an important resource in life sciences research; however, many of the procedures involving vivo models are complex and time consuming. A common problem while conducting experiments is observing the behavior of the models throughout their stay in the bioterium. Ideally, behavioral assessment should be frequent and rigorous, as a way of more accurately characterizing the animal model. However, to date, few suitable automated solutions can be found within the state-of-the-art. In this paper, we propose an autonomous platform for distributed behavioral data acquisition from individual animal habitats in bioteriums, with remote and online access to the data. This approach allows real-time observation of the status of the habitats, and retrieval of the logged data for post-processing. The work focuses on the use case of motion, temperature and water intake monitoring in small rodents, although the platform was designed to be general-purpose and extensible to other types of habitats and sensing configurations.
- 17 June 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 87970J-87970J-10
3D reconstruction methods using line-scanning microscopy with a linear sensor
- 17 June 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 87970J-87970J-10
3D reconstruction methods using line-scanning microscopy with a linear sensor
- 13 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8788, 87882H
Application of line-scanning microscopy using a linear sensor in semiconductor industry: shape and thickness measurements
This work aims at showing the applicability of a scanning-stage bench-microscope in bright-field reflection mode for wirebonding inspection of integrated circuits (IC) as well as quality assurance of tracks in printed circuit boards (PCB). The main issues of our laboratorial prototype arise from the use of a linear image sensor taking advantage of its geometry to achieve lower acquisition time in comparison to traditional (pinhole) confocal approach. The use of a slit-detector is normally related to resolution degradation for details parallel to sensor. But an improvement will surely arise using light distribution along line pixels of the sensor which establishes a great advantage in comparison to (pure) slit detectors. The versatility of this bench-microscope affords excellent means to develop and test algorithms. Those to improve lateral resolution isotropy as well as image visualization and 3D mesh reconstruction under different setups namely illumination modes. Based on the results of these tests tests both wide-field illumination and parallel slit illumination and detection configurations were used in these two applications. Results from IC wire-bonding show the ability of the system to extract 3D information. A comparison of auto-focus images and 3D profiles obtained using different 3D reconstruction algorithms as well as a method for the determination of the diameter of the bond wire are presented. Measurements of PCB track width and thickness were performed and the comparison of these results from both longitudinal and transverse tracks stress the limitations of a lower spatial sampling rate induced by the resolution of object stage positioners.
- 13 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8788, 87882H
Application of line-scanning microscopy using a linear sensor in semiconductor industry: shape and thickness measurements
This work aims at showing the applicability of a scanning-stage bench-microscope in bright-field reflection mode for wirebonding inspection of integrated circuits (IC) as well as quality assurance of tracks in printed circuit boards (PCB). The main issues of our laboratorial prototype arise from the use of a linear image sensor taking advantage of its geometry to achieve lower acquisition time in comparison to traditional (pinhole) confocal approach. The use of a slit-detector is normally related to resolution degradation for details parallel to sensor. But an improvement will surely arise using light distribution along line pixels of the sensor which establishes a great advantage in comparison to (pure) slit detectors. The versatility of this bench-microscope affords excellent means to develop and test algorithms. Those to improve lateral resolution isotropy as well as image visualization and 3D mesh reconstruction under different setups namely illumination modes. Based on the results of these tests tests both wide-field illumination and parallel slit illumination and detection configurations were used in these two applications. Results from IC wire-bonding show the ability of the system to extract 3D information. A comparison of auto-focus images and 3D profiles obtained using different 3D reconstruction algorithms as well as a method for the determination of the diameter of the bond wire are presented. Measurements of PCB track width and thickness were performed and the comparison of these results from both longitudinal and transverse tracks stress the limitations of a lower spatial sampling rate induced by the resolution of object stage positioners.
- 9 June 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8086, 80861
A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy
The aim of this work is to obtain improved sectioning ability in our slit-scanning microscope. The experimental setup is based on a linear sensor and different illumination modes were evaluated. MTF measurements from USAF target images showed the great benefit of using slit illumination in comparison to widefield. Experimental determination of Strehl ratios of 0.62 and 0.96 for wide-field and slit-illumination configurations, respectively, is depicted. Also MTF degradation with defocus is fairly established as stated by Strehl ratio decrease from 0.68 to 0.59 in 2 μm defocus using widefield configuration. Experimental measurement of axial response showed good accordance to numerically simulated curves modeled for the same parameters as the experimental setup. Linear sensor microscopy shows its advantage in comparison to simple slit microscopy particularly for slit illumination. Imaging for details running in sensor direction is accomplished for parallel illumination and detection slits as well as effective axial response for right-angled slits. These results indicate that linear sensor microscopy should be able to surpass lateral resolution asymmetry of slit microscopy. Preliminary results from tests to develop a reconstruction method that combine algorithms to improve lateral resolution isotropy of 2D images and those to build 3D images will be presented.© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 9 June 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8086, 80861
A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy
The aim of this work is to obtain improved sectioning ability in our slit-scanning microscope. The experimental setup is based on a linear sensor and different illumination modes were evaluated. MTF measurements from USAF target images showed the great benefit of using slit illumination in comparison to widefield. Experimental determination of Strehl ratios of 0.62 and 0.96 for wide-field and slit-illumination configurations, respectively, is depicted. Also MTF degradation with defocus is fairly established as stated by Strehl ratio decrease from 0.68 to 0.59 in 2 μm defocus using widefield configuration. Experimental measurement of axial response showed good accordance to numerically simulated curves modeled for the same parameters as the experimental setup. Linear sensor microscopy shows its advantage in comparison to simple slit microscopy particularly for slit illumination. Imaging for details running in sensor direction is accomplished for parallel illumination and detection slits as well as effective axial response for right-angled slits. These results indicate that linear sensor microscopy should be able to surpass lateral resolution asymmetry of slit microscopy. Preliminary results from tests to develop a reconstruction method that combine algorithms to improve lateral resolution isotropy of 2D images and those to build 3D images will be presented.© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 23 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8082, 808236
Shape and thickness measurements using a reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy
Linear sensor microscopy as a mode of slit microscopy is faster than confocal microscopy as it eliminates one lateral scanning but its lateral/axial resolution are lower. Regardless specific image formation characteristics dependent on illumination mode its circular symmetry is lost therefore lateral resolution anisotropy arises. The purpose of this work is to evaluate the application of a low-cost scanning-stage bench-microscope in brightfield reflection mode using a linear sensor for shape and thickness measurements. Firstly we describe overall system architecture emphasizing its effectiveness to easily accommodate different optical setups. In particular different configurations of scanning microscopes are briefly described and a comparison of its image formation characteristics is presented giving special attention to the effect of slit illumination/detection. Results of lateral resolution in both lateral orientations show slit illumination should be used. A reconstruction method used to build three-dimensional representations from images of 3D structures results in relief borders shapes equally defined independently of its orientation relative to sensor. Further results of its application for the measurement of height and thickness of PCB tracks show its inherent ability though a more robust reconstruction algorithm integrating data from light distribution in sensor is being developed to improve clearness and measurement accuracy.
- 23 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8082, 808236
Shape and thickness measurements using a reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy
Linear sensor microscopy as a mode of slit microscopy is faster than confocal microscopy as it eliminates one lateral scanning but its lateral/axial resolution are lower. Regardless specific image formation characteristics dependent on illumination mode its circular symmetry is lost therefore lateral resolution anisotropy arises. The purpose of this work is to evaluate the application of a low-cost scanning-stage bench-microscope in brightfield reflection mode using a linear sensor for shape and thickness measurements. Firstly we describe overall system architecture emphasizing its effectiveness to easily accommodate different optical setups. In particular different configurations of scanning microscopes are briefly described and a comparison of its image formation characteristics is presented giving special attention to the effect of slit illumination/detection. Results of lateral resolution in both lateral orientations show slit illumination should be used. A reconstruction method used to build three-dimensional representations from images of 3D structures results in relief borders shapes equally defined independently of its orientation relative to sensor. Further results of its application for the measurement of height and thickness of PCB tracks show its inherent ability though a more robust reconstruction algorithm integrating data from light distribution in sensor is being developed to improve clearness and measurement accuracy.
- 2 July 2009
- Published by SPIE-Intl Soc Optical Eng
- p. 73671F-73671F-8
Development and assessment of image reconstruction algorithms using a low-cost bench-microscope based on a linear CMOS image sensor
We aim at establishing a bench-microscope based on a linear sensor as a versatile research tool for the development and assessment of image reconstruction algorithms. Therefore we built a laboratory prototype of a scanning-stage bright-field microscope. It is epi-illuminated with a white-light source. The detector is a linear CMOS image sensor. A stand-alone sensor readout module has been developed and integrated in this low-cost bench-microscope. Through lateral scanning along one axis it acquires two-dimensional (2D) images of the specimen that suffer from substantial contributions from out-of-focus portions. This haze in the optical slices will be removed or significantly diminished using computational methods. As the output performance of these methods is extremely dependent on the imaging quality of the microscope prototype, two types of measurement to assess it are described. Axial discrimination will be evaluated along with the development of computational methods. Nevertheless a plane reflector was scanned along z-axis to measure intrinsic axial response of this microscope arrangement. Results of overall system resolution and contrast are presented. At last, preliminary results of three-dimensional (3D) image reconstruction using a simple algorithm to find the best-in-focus image through the determination of maximum intensity are presented. Raw bright-field images from wire bond of an integrated circuit (IC) were used.
- 2 July 2009
- Published by SPIE-Intl Soc Optical Eng
- p. 73671F-73671F-8
Development and assessment of image reconstruction algorithms using a low-cost bench-microscope based on a linear CMOS image sensor
We aim at establishing a bench-microscope based on a linear sensor as a versatile research tool for the development and assessment of image reconstruction algorithms. Therefore we built a laboratory prototype of a scanning-stage bright-field microscope. It is epi-illuminated with a white-light source. The detector is a linear CMOS image sensor. A stand-alone sensor readout module has been developed and integrated in this low-cost bench-microscope. Through lateral scanning along one axis it acquires two-dimensional (2D) images of the specimen that suffer from substantial contributions from out-of-focus portions. This haze in the optical slices will be removed or significantly diminished using computational methods. As the output performance of these methods is extremely dependent on the imaging quality of the microscope prototype, two types of measurement to assess it are described. Axial discrimination will be evaluated along with the development of computational methods. Nevertheless a plane reflector was scanned along z-axis to measure intrinsic axial response of this microscope arrangement. Results of overall system resolution and contrast are presented. At last, preliminary results of three-dimensional (3D) image reconstruction using a simple algorithm to find the best-in-focus image through the determination of maximum intensity are presented. Raw bright-field images from wire bond of an integrated circuit (IC) were used.
- 18 June 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6617, 66170A
Modeling of image formation of a low-cost white-light bench microscope with a linear CMOS image sensor: its application in metrology
Three-dimensional (3D) microscopy techniques are essentially imaging methods but owing to its ability to get depth information they are widely used in optical metrology. Although the fact that there are numerous examples of applications of confocal microscopy for metrology systems those 3D techniques that more recently came up are very sparse in this field despite its similar optical sectioning ability. In particular there is no report in literature to our knowledge of metrology systems taking advantage of the low-cost, versatility and easy integration of CMOS linear image sensors. We have developed a bench-microscope prototype using LIS-1024 linear sensor (Panavision ©) and have built a model of microscope image formation using Matlab ((Mathworks ©) that is currently being tested in order to optimize sensor performance. The prototype comprises commercial and low-cost mechanical and optical components and a developed sensor readout board based on PIC16F876 microcontroller (Microchip Inc.) allowing its integration in the optical setup. This stage-scanning microscope builds the image through the movement of the specimen in one lateral, in opposition to confocal microscopy that demands scanning in both lateral directions, and in axial direction. Both the actuators control for positioning the object stage and the sensor readout for image acquisition are commanded from a Matlab application in a PC. This paper aims at showing the effectiveness of this model of image formation for the application of this low-cost prototype using a linear sensor also in metrology field. Results will be presented from tests that are being carried out with micromachined components.
- 18 June 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6617, 66170A
Modeling of image formation of a low-cost white-light bench microscope with a linear CMOS image sensor: its application in metrology
Three-dimensional (3D) microscopy techniques are essentially imaging methods but owing to its ability to get depth information they are widely used in optical metrology. Although the fact that there are numerous examples of applications of confocal microscopy for metrology systems those 3D techniques that more recently came up are very sparse in this field despite its similar optical sectioning ability. In particular there is no report in literature to our knowledge of metrology systems taking advantage of the low-cost, versatility and easy integration of CMOS linear image sensors. We have developed a bench-microscope prototype using LIS-1024 linear sensor (Panavision ©) and have built a model of microscope image formation using Matlab ((Mathworks ©) that is currently being tested in order to optimize sensor performance. The prototype comprises commercial and low-cost mechanical and optical components and a developed sensor readout board based on PIC16F876 microcontroller (Microchip Inc.) allowing its integration in the optical setup. This stage-scanning microscope builds the image through the movement of the specimen in one lateral, in opposition to confocal microscopy that demands scanning in both lateral directions, and in axial direction. Both the actuators control for positioning the object stage and the sensor readout for image acquisition are commanded from a Matlab application in a PC. This paper aims at showing the effectiveness of this model of image formation for the application of this low-cost prototype using a linear sensor also in metrology field. Results will be presented from tests that are being carried out with micromachined components.