Richard H. Maurer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard H. Maurer has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
J. O. Goldsten
Space Sector The Johns Hopkins University Applied Physics Laboratory Laurel MD USA
3 shared publicationsD. R. Roth
The Johns Hopkins Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, Maryland 20723-6099
2 shared publicationsJ. D. Kinnison
The Johns Hopkins Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, Maryland 20723-6099
2 shared publicationsR. Fainchtein
The Johns Hopkins Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, Maryland 20723-6099
2 shared publicationsA. K. Thompson
1 shared publicationC.J. Zeitlin
1 shared publication
Latest Publications
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (12) , 2408-2416
An Algorithmic Approach to Observed Single Event Effects in Van Allen Probes Solid State Recorders
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (12) , 2408-2416
An Algorithmic Approach to Observed Single Event Effects in Van Allen Probes Solid State Recorders
- Open Access
- 12 October 2018
- Published by American Geophysical Union (AGU) in Space Weather
- Vol. 16 (10) , 1561-1569
Five‐Year Results From the Engineering Radiation Monitor and Solar Cell Monitor on the VanAllen Probes Mission
The Engineering Radiation Monitor measures dose, dose rate, and charging currents on the Van Allen Probes mission to study the dynamics of Earth's Van Allen radiation belts. Over 5 years, results from this monitor show a variation in dose rates with time, a correlation between the dosimeter and charging current data, and a comparison of cumulative dose to prelaunch modeling. Solar cell degradation monitor patches track the decrease in solar array output as displacement damage accumulates. The Solar Cell Monitor shows ~33% cumulative degradation in maximum power after 5.1 years of the mission. The desire to extend the mission to ~2,500 days from 800 days created increased requirements for the ionizing radiation hardness of spacecraft and science instrument electronics. We describe the investigations that insured compliance with these enhanced requirements.
- 12 October 2018
- Published by American Geophysical Union (AGU) in Space Weather
- Vol. 16 (10) , 1561-1569
Open AccessFive‐Year Results From the Engineering Radiation Monitor and Solar Cell Monitor on the VanAllen Probes Mission
The Engineering Radiation Monitor measures dose, dose rate, and charging currents on the Van Allen Probes mission to study the dynamics of Earth's Van Allen radiation belts. Over 5 years, results from this monitor show a variation in dose rates with time, a correlation between the dosimeter and charging current data, and a comparison of cumulative dose to prelaunch modeling. Solar cell degradation monitor patches track the decrease in solar array output as displacement damage accumulates. The Solar Cell Monitor shows ~33% cumulative degradation in maximum power after 5.1 years of the mission. The desire to extend the mission to ~2,500 days from 800 days created increased requirements for the ionizing radiation hardness of spacecraft and science instrument electronics. We describe the investigations that insured compliance with these enhanced requirements.
- 20 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (11) , 2782-2793
Radiation-Induced Single-Event Effects on the Van Allen Probes Spacecraft
Electronic devices on the Van Allen Probes mission have experienced more than a thousand single-event effects (SEE) during the 4.5 years of transit through the inner and outer earth trapped radiation belts. The majority of these SEE have been due to trapped protons determined by the orbit timing and the dose rate response of the engineering radiation monitor. Fault tolerant systems engineering and spacecraft operation have enabled a successful mission to date without a safe mode or spacecraft emergency.
- 20 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (11) , 2782-2793
Radiation-Induced Single-Event Effects on the Van Allen Probes Spacecraft
Electronic devices on the Van Allen Probes mission have experienced more than a thousand single-event effects (SEE) during the 4.5 years of transit through the inner and outer earth trapped radiation belts. The majority of these SEE have been due to trapped protons determined by the orbit timing and the dose rate response of the engineering radiation monitor. Fault tolerant systems engineering and spacecraft operation have enabled a successful mission to date without a safe mode or spacecraft emergency.
- 21 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 428-432
Compact Combined Ion and Neutron Spectrometer (CINS) for Space Application
We are developing a combined ion and neutron spectrometer (CINS) for space applications inside interplanetary transport vehicles and on planetary surfaces. Our concept for a charged particle telescope includes thick silicon detectors and both thin and thick scintillators. The neutron spectrometer has been under development since 1997 with versions being flown on aircraft and balloon flights. We present 1) charge and energy spectra for the thick silicon detectors from heavy ion experiments; 2) typical neutron prompt and delayed pulse height spectra from neutron accelerator beam experiments; and 3) simulations from modeling of the compact charged particle telescope showing ion species identification and energy deposition spectra.
- 21 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 428-432
Compact Combined Ion and Neutron Spectrometer (CINS) for Space Application
We are developing a combined ion and neutron spectrometer (CINS) for space applications inside interplanetary transport vehicles and on planetary surfaces. Our concept for a charged particle telescope includes thick silicon detectors and both thin and thick scintillators. The neutron spectrometer has been under development since 1997 with versions being flown on aircraft and balloon flights. We present 1) charge and energy spectra for the thick silicon detectors from heavy ion experiments; 2) typical neutron prompt and delayed pulse height spectra from neutron accelerator beam experiments; and 3) simulations from modeling of the compact charged particle telescope showing ion species identification and energy deposition spectra.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 116 (1-4) , 125-130
Neutron production from 200–500 MeV proton interaction with spacecraft materials
We report on detailed energy spectra of neutron production >14 MeV from collisions of 200–500 MeV protons with combinations of aluminium, graphite and polyethylene. Comparisons of normalised neutron spectra are made with respect to incident proton energy, angle of neutron production and material. In general, carbon (graphite) or polyethylene (by itself or in combination with aluminium) reduce secondary neutron production >14 MeV relative to the production from interactions in aluminium.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 116 (1-4) , 125-130
Neutron production from 200–500 MeV proton interaction with spacecraft materials
We report on detailed energy spectra of neutron production >14 MeV from collisions of 200–500 MeV protons with combinations of aluminium, graphite and polyethylene. Comparisons of normalised neutron spectra are made with respect to incident proton energy, angle of neutron production and material. In general, carbon (graphite) or polyethylene (by itself or in combination with aluminium) reduce secondary neutron production >14 MeV relative to the production from interactions in aluminium.
- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 504 (1) , 312-317
Portable real time neutron spectrometry II
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 504 (1) , 312-317
Portable real time neutron spectrometry II
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
- 1 January 1999
- Published by AIP Publishing
- p. 415-419
Portable real time neutron spectrometry
We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.
- 1 January 1999
- Published by AIP Publishing
- p. 415-419
Portable real time neutron spectrometry
We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.