Karol Balog
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Karol Balog has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Jozef Martinka
Institute of Integrated Safety, Faculty of Materials Science and Technology in Trnava, Slovak University of Technology in Bratislava, 91724 Trnava, Slovakia
20 shared publications Tomáš Chrebet
Slovak University of Technology in Bratislava
10 shared publications- Peter Rantuch
Institute of Integrated Safety, Faculty of Materials Science and Technology in Trnava, Slovak University of Technology in Bratislava, 91724 Trnava, Slovakia
9 shared publications - Igor Wachter
Institute of Integrated Safety, Faculty of Materials Science and Technology in Trnava, Slovak University of Technology in Bratislava, 91724 Trnava, Slovakia
6 shared publications - Ivan Šimkovic
Institute of Chemistry, Slovak Academy of Sciences, 84538 Bratislava, Slovakia
6 shared publications Ivan Hrušovský
Faculty of Materials Science and Technology in Trnava, Slovak University of Technology in Bratislava, Trnava, Slovakia
5 shared publications
Latest Publications
- Open Access
A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables
Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length.
Open AccessA New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables
Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length.
- Open Access
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 87-95
Human Performance Tools Used as Incident Prevention Applied to a Construction Phase of a Nuclear Power Plant Mochovce
In order to manage the Construction Safety in a professional and due manner, it is of the key importance to have in place an Occupational Health and Safety Management System, consisting, similarly as a house project, of correct foundations as preparation, planning, procurement, properly set up rules and contractual relations, especially if a site of approx. 5,000 daily manpower is of a concern. Pillars of safe construction follow, i.e. education and training, inspections, communication and, last but not least, human behaviour. The purpose of the following article is to introduce the Human Behaviour Improvement Tools applied in the NPP Mochovce, completion process of Units 3&4, focusing on the implementation and the observance of the OH&S rules.
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 87-95
Open AccessHuman Performance Tools Used as Incident Prevention Applied to a Construction Phase of a Nuclear Power Plant Mochovce
In order to manage the Construction Safety in a professional and due manner, it is of the key importance to have in place an Occupational Health and Safety Management System, consisting, similarly as a house project, of correct foundations as preparation, planning, procurement, properly set up rules and contractual relations, especially if a site of approx. 5,000 daily manpower is of a concern. Pillars of safe construction follow, i.e. education and training, inspections, communication and, last but not least, human behaviour. The purpose of the following article is to introduce the Human Behaviour Improvement Tools applied in the NPP Mochovce, completion process of Units 3&4, focusing on the implementation and the observance of the OH&S rules.
- Open Access
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 29-39
Heat of Combustion as the Key Fire Characteristics of Electrical Cables
This scientific study deals with investigation of the heat of combustion and effective heat of combustion of selected electrical cables. Two different electrical cables for rated voltage of 0.6/1 kV were investigated. Both cables were power three-core with cross-section area of each core of 1.5 mm 2 . The cores of both cables were made of a bar cooper wire. Insulations of conductors of both cables were made of silane cross-linked polyethylene without any inorganic filler, while the bedding and outer sheath were made of polyethylene-based copolymer (the beddings were filled with two fillers - aluminium hydroxide and calcium carbonate, while the outer sheath were filled only with aluminium hydroxide). Reaction to fire class of both cables was B2 ca , s1, d0, a1. The main difference in the investigated cables was that the core of one of them was wrapped in a glass mica tape (this cable showed circuit integrity maintenance under fire conditions during 180 minutes). The heat of combustion and effective heat of combustion were determined by the oxygen bomb calorimeter according to the ISO 1716:2018 standard. The highest effective heat of combustion showed the insulation of wires (for both cables 42.47 ± 0.03 MJ/kg), lower value showed outer sheath (interval form13.61 to 15.26 MJ/kg) and the lowest value was determined for bedding (interval from 4.69 to 6.39 MJ/kg). The effective heath of combustion per unit of length of both investigated cables lies in the interval from 1.37 to 1.38 MJ/m. Therefore, there is no significant difference in effective heats of combustion of the electrical cables investigated.
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 29-39
Open AccessHeat of Combustion as the Key Fire Characteristics of Electrical Cables
This scientific study deals with investigation of the heat of combustion and effective heat of combustion of selected electrical cables. Two different electrical cables for rated voltage of 0.6/1 kV were investigated. Both cables were power three-core with cross-section area of each core of 1.5 mm 2 . The cores of both cables were made of a bar cooper wire. Insulations of conductors of both cables were made of silane cross-linked polyethylene without any inorganic filler, while the bedding and outer sheath were made of polyethylene-based copolymer (the beddings were filled with two fillers - aluminium hydroxide and calcium carbonate, while the outer sheath were filled only with aluminium hydroxide). Reaction to fire class of both cables was B2 ca , s1, d0, a1. The main difference in the investigated cables was that the core of one of them was wrapped in a glass mica tape (this cable showed circuit integrity maintenance under fire conditions during 180 minutes). The heat of combustion and effective heat of combustion were determined by the oxygen bomb calorimeter according to the ISO 1716:2018 standard. The highest effective heat of combustion showed the insulation of wires (for both cables 42.47 ± 0.03 MJ/kg), lower value showed outer sheath (interval form13.61 to 15.26 MJ/kg) and the lowest value was determined for bedding (interval from 4.69 to 6.39 MJ/kg). The effective heath of combustion per unit of length of both investigated cables lies in the interval from 1.37 to 1.38 MJ/m. Therefore, there is no significant difference in effective heats of combustion of the electrical cables investigated.
- Open Access
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 41-47
Impact of Selected Electrical Cables Slope on Flame Out Time and Flame Spread
The aim of the research described in this paper was to study the impact of the electrical cables slope on the flame out time and the flame spread rate. Measured cables were thermally loaded by methanol flame (diameter of the container was 106 mm) at seven different slopes with respect to the horizontal plane (the slopes were 0° – horizontal orientation, 15°, 30°, 45°, 60°, 75° and 90° - vertical orientation). The first tested electrical cable was a copper three-core power one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 1.5 mm 2 ). The second tested electrical cable was a copper two-core signal one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 0.5 mm 2 ). The first electrical cable did not show reaction to fire class. The reaction to fire class of the second tested cable was B2 ca , s1, d1, a1. The obtained results proved that slope had virtually no impact on the flame out time and the flame spread over the tested cable surface (tested cables of all slopes stopped burning after 1 to 5 seconds after methanol flame burned out). Likewise, the flame spread was only negligibly beyond the border of flame action for each cable slope.
- 1 June 2019
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 27 (44) , 41-47
Open AccessImpact of Selected Electrical Cables Slope on Flame Out Time and Flame Spread
The aim of the research described in this paper was to study the impact of the electrical cables slope on the flame out time and the flame spread rate. Measured cables were thermally loaded by methanol flame (diameter of the container was 106 mm) at seven different slopes with respect to the horizontal plane (the slopes were 0° – horizontal orientation, 15°, 30°, 45°, 60°, 75° and 90° - vertical orientation). The first tested electrical cable was a copper three-core power one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 1.5 mm 2 ). The second tested electrical cable was a copper two-core signal one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 0.5 mm 2 ). The first electrical cable did not show reaction to fire class. The reaction to fire class of the second tested cable was B2 ca , s1, d1, a1. The obtained results proved that slope had virtually no impact on the flame out time and the flame spread over the tested cable surface (tested cables of all slopes stopped burning after 1 to 5 seconds after methanol flame burned out). Likewise, the flame spread was only negligibly beyond the border of flame action for each cable slope.
- 25 March 2019
- Published by Taylor & Francis
- p. 229-234
Influence of fissures in timber on the charring rate
The charring depth, rate and residual cross-section have a significant influence on the mechanical resistance of timber members in fire. In case of various dimensions of fissures, it is possible that as the cross-section reduces to the residual one, the mechanical resistance will be reduced as well. In the absence of rules that allows incorporating the influence of fissures on the charring rate, this paper is focused on the numerical analysis and experimental measurements of selected dimensions and number of fissures. In terms of results, the smaller fissures can be neglected, whilst the bigger fissures should be taken into account by means of increased value of the charring rate, or by advanced calculations.
- 25 March 2019
- Published by Taylor & Francis
- p. 229-234
Influence of fissures in timber on the charring rate
The charring depth, rate and residual cross-section have a significant influence on the mechanical resistance of timber members in fire. In case of various dimensions of fissures, it is possible that as the cross-section reduces to the residual one, the mechanical resistance will be reduced as well. In the absence of rules that allows incorporating the influence of fissures on the charring rate, this paper is focused on the numerical analysis and experimental measurements of selected dimensions and number of fissures. In terms of results, the smaller fissures can be neglected, whilst the bigger fissures should be taken into account by means of increased value of the charring rate, or by advanced calculations.
- Open Access
- 1 June 2018
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 26 (42) , 21-27
Fire Risk of Halogen-Free Electrical Cable
This paper deals with the fire risk of a selected halogen-free electrical cable. The research was objected to a three-core power electric cable for a fixed installation CHKE J3x1.5 (cross section of each copper core was 1.5 mm 2 ) with a declared class of reaction to fire B2 ca , s1, d1, a1. The electrical cable was manufactured and supplied by VUKI, a. s., Slovakia. The fire risk of the electric cable was evaluated based on the heat release rate, total heat release, smoke release rate, total smoke release and effective heat of combustion. These parameters were measured using a cone calorimeter at 50 kW m −2 (specimens and cone emitter were placed horizontally during the test). The measured electrical cable showed a maximum heat release rate of nearly 150 kW m −2 , a maximum average heat emission rate of almost 100 kW m −2 , a total heat release of almost 130 MJ m −2 , a maximum smoke release rate of almost 2.5 s −1 , a total smoke release of more than 800 m 2 m −2 , an effective heat of combustion (cable as a whole) of nearly 9 MJ kg −1 and an effective heat of emission (polymeric parts of the cable) of 26.5 MJ kg −1 .
- 1 June 2018
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 26 (42) , 21-27
Open AccessFire Risk of Halogen-Free Electrical Cable
This paper deals with the fire risk of a selected halogen-free electrical cable. The research was objected to a three-core power electric cable for a fixed installation CHKE J3x1.5 (cross section of each copper core was 1.5 mm 2 ) with a declared class of reaction to fire B2 ca , s1, d1, a1. The electrical cable was manufactured and supplied by VUKI, a. s., Slovakia. The fire risk of the electric cable was evaluated based on the heat release rate, total heat release, smoke release rate, total smoke release and effective heat of combustion. These parameters were measured using a cone calorimeter at 50 kW m −2 (specimens and cone emitter were placed horizontally during the test). The measured electrical cable showed a maximum heat release rate of nearly 150 kW m −2 , a maximum average heat emission rate of almost 100 kW m −2 , a total heat release of almost 130 MJ m −2 , a maximum smoke release rate of almost 2.5 s −1 , a total smoke release of more than 800 m 2 m −2 , an effective heat of combustion (cable as a whole) of nearly 9 MJ kg −1 and an effective heat of emission (polymeric parts of the cable) of 26.5 MJ kg −1 .
- Open Access
- 20 November 2017
- Published by STEF92 Technology
- Vol. 17
KEY PROPERTIES OF COMBUSTION PRODUCTS AND THEIR APPLICATION IN FIRE SAFETY ENGINEERING
- 20 November 2017
- Published by STEF92 Technology
- Vol. 17
Open AccessKEY PROPERTIES OF COMBUSTION PRODUCTS AND THEIR APPLICATION IN FIRE SAFETY ENGINEERING
- Open Access
- 20 November 2017
- Published by STEF92 Technology
- Vol. 17
DETETMINATION OF THE HEAT GENERATION OF WOOD PELLETS DURING FLAME AND FLAMELESS COMBUSTION
- 20 November 2017
- Published by STEF92 Technology
- Vol. 17
Open AccessDETETMINATION OF THE HEAT GENERATION OF WOOD PELLETS DURING FLAME AND FLAMELESS COMBUSTION
- 30 August 2017
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 131 (2) , 899-906
Calorific value and fire risk of selected fast-growing wood species
- 30 August 2017
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 131 (2) , 899-906
Calorific value and fire risk of selected fast-growing wood species
- Open Access
- 1 June 2017
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 25 (40) , 9-16
Determination of the Explosion Characteristics of Wheat Flour
The article deals with the measurement of explosion characteristics of wheat flour. The measurements were carried out according to STN EN 14034-1+A1:2011 Determination of explosion characteristics of dust clouds. Part 1: Determination of the maximum explosion pressure p max of dust clouds, the maximum rate of explosion pressure rise according to STN EN 14034-2+A1:2012 Determination of explosion characteristics of dust clouds - Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt) max of dust clouds and LEL according to STN EN 14034-3+A1:2011 Determination of explosion characteristics of dust clouds: Determination of the lower explosion limit LEL of dust clouds. The testing of explosions of wheat flour dust clouds showed that the maximum value of the pressure was reached at the concentrations of 600 g/m 3 and its value is 8.32 bar/s. The fastest increase of pressure was observed at the concentration of 750 g/m 3 and its value was 54.2 bar/s.
- 1 June 2017
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 25 (40) , 9-16
Open AccessDetermination of the Explosion Characteristics of Wheat Flour
The article deals with the measurement of explosion characteristics of wheat flour. The measurements were carried out according to STN EN 14034-1+A1:2011 Determination of explosion characteristics of dust clouds. Part 1: Determination of the maximum explosion pressure p max of dust clouds, the maximum rate of explosion pressure rise according to STN EN 14034-2+A1:2012 Determination of explosion characteristics of dust clouds - Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt) max of dust clouds and LEL according to STN EN 14034-3+A1:2011 Determination of explosion characteristics of dust clouds: Determination of the lower explosion limit LEL of dust clouds. The testing of explosions of wheat flour dust clouds showed that the maximum value of the pressure was reached at the concentrations of 600 g/m 3 and its value is 8.32 bar/s. The fastest increase of pressure was observed at the concentration of 750 g/m 3 and its value was 54.2 bar/s.