Kazuhisa Mitsuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kazuhisa Mitsuda has a total of 356 co-authors. Here are the top co-authors by number of shared publications:
- Noriko Y. Yamasaki
Institute of Space and Astronautical Science (ISAS)
31 shared publications - Ryuichi Fujimoto
Institute of Space and Astronautical Science (ISAS), Japan Aerospace Exploration Agency (JAXA)
13 shared publications Takaya Ohashi
Department of Physics, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji, Tokyo, Japan
12 shared publications- Yuichiro Ezoe
Department of Physics, Tokyo Metropolitan University
8 shared publications - Tasuku Hayashi
Rikkyo University Department of Physics 3-34-1 Nishi-Ikebukuro, Toshima-ku, Tokyo 171-8501
7 shared publications - Yoh Takei
Japan Aerospace Exploration Agency
7 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 1009 (2) , 233
Probing Axion–Photon Mixing with High-resolution X-Ray Spectroscopy
Axion-like particles (ALPs) provide a compelling avenue for exploring physics beyond the Standard Model. In astrophysical magnetized plasmas, an ALP–photon coupling g aγ induces energy-dependent oscillations in the photon survival probability that imprint modulations on emission spectra. X-ray observations of bright spectrally smooth sources can provide particularly sensitive probes of ultralight ALPs with masses m a ≲ 10 −11 eV due to long propagation distances, strong magnetic fields, and high photon statistics. We present a comprehensive forecast of ALP–photon conversion in three representative systems: (i) background active galactic nuclei (AGNs) observed through foreground intracluster magnetic fields, (ii) central AGNs within their host cluster halos, and (iii) Galactic X-ray binaries viewed through the Milky Way field. Using detailed simulations, we assess the prospective sensitivity of high-resolution X-ray missions including XRISM, Athena, and Arcus. For typical magnetic field configurations, a 320 ks XRISM observation or an 8 ks Athena observation of the Perseus Cluster AGN NGC 1275 can reach down to g aγ ∼ 5 × 10 −13 GeV −1 at m a ≲ 10 −12 eV, surpassing the current best limit. We quantify the impact of magnetic field modeling, photon statistics, and spectral binning strategies. Our results demonstrate the scientific potential of future X-ray observatories to probe photon–ALP coupling in previously inaccessible parameter space, offering a powerful window into physics beyond the Standard Model.
- 30 September 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 1009 (2) , 233
Open AccessProbing Axion–Photon Mixing with High-resolution X-Ray Spectroscopy
Axion-like particles (ALPs) provide a compelling avenue for exploring physics beyond the Standard Model. In astrophysical magnetized plasmas, an ALP–photon coupling g aγ induces energy-dependent oscillations in the photon survival probability that imprint modulations on emission spectra. X-ray observations of bright spectrally smooth sources can provide particularly sensitive probes of ultralight ALPs with masses m a ≲ 10 −11 eV due to long propagation distances, strong magnetic fields, and high photon statistics. We present a comprehensive forecast of ALP–photon conversion in three representative systems: (i) background active galactic nuclei (AGNs) observed through foreground intracluster magnetic fields, (ii) central AGNs within their host cluster halos, and (iii) Galactic X-ray binaries viewed through the Milky Way field. Using detailed simulations, we assess the prospective sensitivity of high-resolution X-ray missions including XRISM, Athena, and Arcus. For typical magnetic field configurations, a 320 ks XRISM observation or an 8 ks Athena observation of the Perseus Cluster AGN NGC 1275 can reach down to g aγ ∼ 5 × 10 −13 GeV −1 at m a ≲ 10 −12 eV, surpassing the current best limit. We quantify the impact of magnetic field modeling, photon statistics, and spectral binning strategies. Our results demonstrate the scientific potential of future X-ray observatories to probe photon–ALP coupling in previously inaccessible parameter space, offering a powerful window into physics beyond the Standard Model.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of TES Microcalorimeters With Serpentine Absorbers for Two-Dimensional Position Detection
This study focuses on the development of TES (Transition Edge Sensor) microcalorimeters for gamma-ray detection. We developed a position-sensitive TES (PoST) based on our single-pixel TES, constructed from a titanium-gold (Ti/Au) bilayer. The PoST consists of a TES coupled with elongated absorbers to enable position sensitivity. Lead was chosen as the absorber material due to its high stopping power for high-energy gamma rays. However, the thermal contraction mismatch between lead and the TES substrate posed a risk of damage during cooling. To address this issue, we developed a method utilizing serpentine-shaped absorbers, which enables two-dimensional position detection while maintaining the same number of wires as a conventional one-dimensional PoST. The feasibility of this approach was demonstrated with two types of prototype absorbers, and the experimental results are presented below.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of TES Microcalorimeters With Serpentine Absorbers for Two-Dimensional Position Detection
This study focuses on the development of TES (Transition Edge Sensor) microcalorimeters for gamma-ray detection. We developed a position-sensitive TES (PoST) based on our single-pixel TES, constructed from a titanium-gold (Ti/Au) bilayer. The PoST consists of a TES coupled with elongated absorbers to enable position sensitivity. Lead was chosen as the absorber material due to its high stopping power for high-energy gamma rays. However, the thermal contraction mismatch between lead and the TES substrate posed a risk of damage during cooling. To address this issue, we developed a method utilizing serpentine-shaped absorbers, which enables two-dimensional position detection while maintaining the same number of wires as a conventional one-dimensional PoST. The feasibility of this approach was demonstrated with two types of prototype absorbers, and the experimental results are presented below.
- 19 December 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Space Physics
- Vol. 128 (12)
Geocoronal Solar Wind Charge Exchange Process Associated With the 2006‐December‐13 Coronal Mass Ejection Event
We report the discovery of a geocoronal solar wind charge exchange (SWCX) event corresponding to the well‐known 2006 December 13th coronal mass ejection (CME) event. Strong evidence for the charge exchange origin of this transient diffuse emission is provided by prominent non‐thermal emission lines at energies of O7+, Ne9+, Mg11+, Si12+, Si13+. Especially, a 0.53 keV emission line that most likely arises from the N5+ 1s15p1 → 1s2 transition is detected. Previously, the forecastability of SWCX occurrence with proton flares has been disputed. In this particular event, we found that the SWCX signal coincided with the arrival of the magnetic cloud inside CME, triggered with a time delay after the proton flux fluctuation as the CME shock front passed through the Earth. Moreover, a spacecraft orbital modulation in SWCX light curve suggests that the emission arises close to the Earth. The line of sight was found to always pass through the northern magnetospheric cusp. The SWCX intensity was high when the line of sight passed the dusk side of the cusp, suggesting an azimuthal anisotropy in the flow of solar‐wind ions inside the cusp. An axisymmetric SWCX emission model is found to underestimate the observed peak intensity by a factor of about 50. We suggest this discrepancy is related to the azimuthal anisotropy of the solar‐wind flow in the cusp.
- 19 December 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Space Physics
- Vol. 128 (12)
Geocoronal Solar Wind Charge Exchange Process Associated With the 2006‐December‐13 Coronal Mass Ejection Event
We report the discovery of a geocoronal solar wind charge exchange (SWCX) event corresponding to the well‐known 2006 December 13th coronal mass ejection (CME) event. Strong evidence for the charge exchange origin of this transient diffuse emission is provided by prominent non‐thermal emission lines at energies of O7+, Ne9+, Mg11+, Si12+, Si13+. Especially, a 0.53 keV emission line that most likely arises from the N5+ 1s15p1 → 1s2 transition is detected. Previously, the forecastability of SWCX occurrence with proton flares has been disputed. In this particular event, we found that the SWCX signal coincided with the arrival of the magnetic cloud inside CME, triggered with a time delay after the proton flux fluctuation as the CME shock front passed through the Earth. Moreover, a spacecraft orbital modulation in SWCX light curve suggests that the emission arises close to the Earth. The line of sight was found to always pass through the northern magnetospheric cusp. The SWCX intensity was high when the line of sight passed the dusk side of the cusp, suggesting an azimuthal anisotropy in the flow of solar‐wind ions inside the cusp. An axisymmetric SWCX emission model is found to underestimate the observed peak intensity by a factor of about 50. We suggest this discrepancy is related to the azimuthal anisotropy of the solar‐wind flow in the cusp.
- 1 July 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 9 (03) , 034006-15
GEOspace X-ray imager (GEO-X)
GEOspace X-ray imager (GEO-X) is a small satellite mission aiming at visualization of the Earth’s magnetosphere by X-rays and revealing dynamic couplings between solar wind and the magnetosphere. In-situ spacecraft have revealed various phenomena in the magnetosphere. X-ray astronomy satellite observations recently discovered soft X-ray emissions originating from the magnetosphere. We are developing GEO-X by integrating innovative technologies of a wide field of view (FOV) X-ray instrument and a small satellite for deep space exploration. The satellite combines a Cubesat and a hybrid kick motor, which can produce a large delta v to increase the altitude of the orbit to about 30 to 60 RE from a relatively low-altitude (e.g., geo transfer orbit) piggyback launch. GEO-X carries a wide FOV (5 × 5 deg) and a good spatial resolution (10 arcmin) X-ray (0.3 to 2 keV) imaging spectrometer using a micro-machined X-ray telescope and a CMOS detector system combined with an optical blocking filter. We aim to launch the satellite around the solar maximum of solar cycle 25.
- 1 July 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 9 (03) , 034006-15
GEOspace X-ray imager (GEO-X)
GEOspace X-ray imager (GEO-X) is a small satellite mission aiming at visualization of the Earth’s magnetosphere by X-rays and revealing dynamic couplings between solar wind and the magnetosphere. In-situ spacecraft have revealed various phenomena in the magnetosphere. X-ray astronomy satellite observations recently discovered soft X-ray emissions originating from the magnetosphere. We are developing GEO-X by integrating innovative technologies of a wide field of view (FOV) X-ray instrument and a small satellite for deep space exploration. The satellite combines a Cubesat and a hybrid kick motor, which can produce a large delta v to increase the altitude of the orbit to about 30 to 60 RE from a relatively low-altitude (e.g., geo transfer orbit) piggyback launch. GEO-X carries a wide FOV (5 × 5 deg) and a good spatial resolution (10 arcmin) X-ray (0.3 to 2 keV) imaging spectrometer using a micro-machined X-ray telescope and a CMOS detector system combined with an optical blocking filter. We aim to launch the satellite around the solar maximum of solar cycle 25.
- 8 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Fabrication of a 64-Pixel TES Microcalorimeter Array With Iron Absorbers Uniquely Designed for 14.4-keV Solar Axion Search
If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a $^{57}$ Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed into photons by a $^{57}$ Fe absorber, a transition edge sensor (TES) X-ray microcalorimeter should be able to detect them efficiently. We have designed and fabricated a dedicated 64-pixel TES array with iron absorbers for the solar axion search. In order to decrease the effect of iron magnetization on spectroscopic performance, the iron absorber is placed next to the TES while maintaining a certain distance. A gold thermal transfer strap connects them. We have accomplished the electroplating of gold straps with high thermal conductivity. The residual resistivity ratio (RRR) was over 23, more than eight times higher than a previous evaporated strap. In addition, we successfully electroplated pure-iron films of more than a few micrometers in thickness for absorbers and a fabricated 64-pixel TES calorimeter structure.
- 8 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Fabrication of a 64-Pixel TES Microcalorimeter Array With Iron Absorbers Uniquely Designed for 14.4-keV Solar Axion Search
If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a $^{57}$ Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed into photons by a $^{57}$ Fe absorber, a transition edge sensor (TES) X-ray microcalorimeter should be able to detect them efficiently. We have designed and fabricated a dedicated 64-pixel TES array with iron absorbers for the solar axion search. In order to decrease the effect of iron magnetization on spectroscopic performance, the iron absorber is placed next to the TES while maintaining a certain distance. A gold thermal transfer strap connects them. We have accomplished the electroplating of gold straps with high thermal conductivity. The residual resistivity ratio (RRR) was over 23, more than eight times higher than a previous evaporated strap. In addition, we successfully electroplated pure-iron films of more than a few micrometers in thickness for absorbers and a fabricated 64-pixel TES calorimeter structure.
- Open Access
- 1 April 2022
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 929 (2) , 128
Spatial Power Spectral Analysis of the Suzaku X-Ray Background
Power spectra of spatial fluctuations of X-ray emission may impose constraints on the origins of the emission independent of that from the energy spectra. We generated spatial power spectrum densities (PSDs) of blank X-ray skies observed with the Suzaku X-ray observatory utilizing the modified Δ-variance method. Using the total measured count rate as the diagnostic tool, we found that a model consisting of the sum of two components, one for the unresolved faint point sources and one for the uniform flat-field emission, can represent well the observed PSD in three different energy bands (0.2–0.5, 0.5–2, and 2–10 keV); only an upper limit is obtained for the latter component in 2–10 keV. X-ray counting rates corresponding to the best-fit PSD model functions and diffuse emission fractions were estimated, and we confirmed that the sum of the counting rates of two model components is consistent with those actually observed with the detector for all energy bands. The ratio of the flat-field counting rate to the total in 0.5–2 keV, however, is significantly larger than the diffuse emission fraction estimated from the model fits of energy spectra. We discussed that this discrepancy can be reconciled by systematic effects in the PSD and energy spectrum analyses. The present study demonstrates that the spatial power spectrum analysis is powerful in constraining the origins of the X-ray emission.
- 1 April 2022
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 929 (2) , 128
Open AccessSpatial Power Spectral Analysis of the Suzaku X-Ray Background
Power spectra of spatial fluctuations of X-ray emission may impose constraints on the origins of the emission independent of that from the energy spectra. We generated spatial power spectrum densities (PSDs) of blank X-ray skies observed with the Suzaku X-ray observatory utilizing the modified Δ-variance method. Using the total measured count rate as the diagnostic tool, we found that a model consisting of the sum of two components, one for the unresolved faint point sources and one for the uniform flat-field emission, can represent well the observed PSD in three different energy bands (0.2–0.5, 0.5–2, and 2–10 keV); only an upper limit is obtained for the latter component in 2–10 keV. X-ray counting rates corresponding to the best-fit PSD model functions and diffuse emission fractions were estimated, and we confirmed that the sum of the counting rates of two model components is consistent with those actually observed with the detector for all energy bands. The ratio of the flat-field counting rate to the total in 0.5–2 keV, however, is significantly larger than the diffuse emission fraction estimated from the model fits of energy spectra. We discussed that this discrepancy can be reconciled by systematic effects in the PSD and energy spectrum analyses. The present study demonstrates that the spatial power spectrum analysis is powerful in constraining the origins of the X-ray emission.
- Open Access
Spatial Power Spectral Analysis of the Suzaku X-ray Background
Power spectra of spatial fluctuations of X-ray emission may impose constraints on the origins of the emission independent of that from the energy spectra. We generated spatial power spectrum densities (PSD) of blank X-ray skies observed with Suzaku X-ray observatory utilizing the modified $\Delta$-variance method. Using the total measured count rate as the diagnostic tool, we found that a model consisting of the sum of two components, one for the unresolved faint point sources and one for the uniform flat-field emission, can well represent the observed PSD in three different energy bands (0.2-0.5 keV, 0.5-2 keV, and 2-10 keV); only an upper limit is obtained for the latter component in 2-10 keV. X-ray counting rates corresponding to the best-fit PSD model functions and diffuse emission fractions were estimated, and we confirmed that the sum of the counting rates of two model components is consistent with those actually observed with the detector for all energy bands. The ratio of the flat-field counting rate to the total in 0.5-2 keV, however, is significantly larger than the diffuse emission fraction estimated from the model fits of energy spectra. We discussed that this discrepancy can be reconciled by systematic effects in the PSD and energy spectrum analyses. The present study demonstrates that the spatial power spectrum is powerful in constraining the origins of the X-ray emission.
Open AccessSpatial Power Spectral Analysis of the Suzaku X-ray Background
Power spectra of spatial fluctuations of X-ray emission may impose constraints on the origins of the emission independent of that from the energy spectra. We generated spatial power spectrum densities (PSD) of blank X-ray skies observed with Suzaku X-ray observatory utilizing the modified $\Delta$-variance method. Using the total measured count rate as the diagnostic tool, we found that a model consisting of the sum of two components, one for the unresolved faint point sources and one for the uniform flat-field emission, can well represent the observed PSD in three different energy bands (0.2-0.5 keV, 0.5-2 keV, and 2-10 keV); only an upper limit is obtained for the latter component in 2-10 keV. X-ray counting rates corresponding to the best-fit PSD model functions and diffuse emission fractions were estimated, and we confirmed that the sum of the counting rates of two model components is consistent with those actually observed with the detector for all energy bands. The ratio of the flat-field counting rate to the total in 0.5-2 keV, however, is significantly larger than the diffuse emission fraction estimated from the model fits of energy spectra. We discussed that this discrepancy can be reconciled by systematic effects in the PSD and energy spectrum analyses. The present study demonstrates that the spatial power spectrum is powerful in constraining the origins of the X-ray emission.
- 19 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Transition Edge Sensor Microcalorimeter With Bismuth Absorber for Gamma-Ray Measurement
We developed a transition edge sensor (TES) microcalorimeter to measure high-energy gamma-rays in the range of up to several MeV. We performed gamma-ray irradiation experiments using this TES microcalorimeter fabricated with a cubic bismuth cut out (1 × 1 × 0.7 mm). As a result, we successfully achieved an energy resolution of 0.92 keV for 662-keV gamma rays ( 137 Cs) and 0.97 keV for 1332-keV gamma rays ( 60 Co). In addition, we investigated methods to reduce low-frequency noise based on the results obtained by comparing the count rates of pulses with different decay time.
- 19 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Transition Edge Sensor Microcalorimeter With Bismuth Absorber for Gamma-Ray Measurement
We developed a transition edge sensor (TES) microcalorimeter to measure high-energy gamma-rays in the range of up to several MeV. We performed gamma-ray irradiation experiments using this TES microcalorimeter fabricated with a cubic bismuth cut out (1 × 1 × 0.7 mm). As a result, we successfully achieved an energy resolution of 0.92 keV for 662-keV gamma rays ( 137 Cs) and 0.97 keV for 1332-keV gamma rays ( 60 Co). In addition, we investigated methods to reduce low-frequency noise based on the results obtained by comparing the count rates of pulses with different decay time.
- 4 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Development of Gamma-Ray Position-Sensitive Transition-Edge-Sensor Microcalorimeters
Position-sensitive transition-edge sensor (TES) microcalorimeters (PoSTs) were developed to detect gamma rays up to a few MeV. Each gamma-ray PoST comprised a 0.5 mm × 0.5 mm × 19 mm lead absorber with a TES on each end and worked as a 1D imaging spectrometer. Only one TES worked at low temperature and its results are reported herein. We irradiated the PoST device with gamma rays from a Cs-137 source, and the resultant pulses showed strong correlations between the pulse height and the rise time. To determine effective pixels, we separately divided the photopeak and lead-K escape peak pulses into 19 groups after sorting them by their rise times. From the pulse shape distributions, we concluded that the TES was sensitive to the gamma-ray interaction position as long as it was not located too far away from the TES, and that it was probably possible to determine the interaction positions of the entire absorber, if both TESs were working. The PoST device was then modeled and the average pulses of the 19 effective pixels were compared to those of numerical simulations, where the rise time distributions of the actual pulses and simulated pulses were in good agreement.
- 4 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Development of Gamma-Ray Position-Sensitive Transition-Edge-Sensor Microcalorimeters
Position-sensitive transition-edge sensor (TES) microcalorimeters (PoSTs) were developed to detect gamma rays up to a few MeV. Each gamma-ray PoST comprised a 0.5 mm × 0.5 mm × 19 mm lead absorber with a TES on each end and worked as a 1D imaging spectrometer. Only one TES worked at low temperature and its results are reported herein. We irradiated the PoST device with gamma rays from a Cs-137 source, and the resultant pulses showed strong correlations between the pulse height and the rise time. To determine effective pixels, we separately divided the photopeak and lead-K escape peak pulses into 19 groups after sorting them by their rise times. From the pulse shape distributions, we concluded that the TES was sensitive to the gamma-ray interaction position as long as it was not located too far away from the TES, and that it was probably possible to determine the interaction positions of the entire absorber, if both TESs were working. The PoST device was then modeled and the average pulses of the 19 effective pixels were compared to those of numerical simulations, where the rise time distributions of the actual pulses and simulated pulses were in good agreement.
- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.